Introduction to the methodology of EEG recording

Slides:



Advertisements
Similar presentations
Topic Nerves.
Advertisements

بنام خداوند عليم.
BIOPOTENTIAL AMPLIFIERS
Introduction to the methodology of EEG recording
7th Lecture Dimitar Stefanov. Recapping Three types electrodes are used for sensing of EMG signals: 1.indwelling (intramuscular) electrodes (single fiber.
MIAMI Research Group Electrical and Computer Eng. Dept. MIAMI Medical Instrument Analysis and Machine Intelligence
ECG Signal Processing Ojasvi Verma
Biofeedback Jennifer L. Doherty-Restrepo Entry-level Athletic Training Education Program PET 4995: Therapeutic Modalities.
ELECTROCARDIOGRAM (ECG)
Noise and Interference Reduction Joel Neher and Linshu Li.
The Electrical Nature of Nerves
What are we measuring with EEG and MEG James Kilner.
Artifact (artefact) reduction in EEG – and a bit of ERP basics CNC, 19 November 2014 Jakob Heinzle Translational Neuromodeling Unit.
Microelectronics System Design for Chronic Brain Implants ECEN 5007 S. Johnson, V. Ganesan
Homeostasis Homeo = similar, stasis = condition Defined as the ability to maintain a relatively stable internal environment The human body maintains hundreds.
Diagnostic electromagnetic equipment. Physical principles electrographic methods in the diagnosis of diseases.
Example Problem You are measuring the EEG of a patient and accidently choose two different types of electrodes for EEG lead. One of them has a source impedance.
Lecture II: Linear Applications of Opamp
Chapter 5: Signals and Noise
Nervous systems. Keywords (reading p ) Nervous system functions Structure of a neuron Sensory, motor, inter- neurons Membrane potential Sodium.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Closed and Open Electrical Fields
Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems Copyright © 2008–2013 National Academy Foundation. All rights reserved.
Biomedical Instrumentation
Biology 41.1 nervous System
Electromyography (EMG) Theory of Operation & Underlying Anatomical and Physiological Issues.
Biopotential Amplifier Speaker: Sun Shih-Yu 3/20, 2006.
EEG Biofeedback Device Ashley Anderson, Michelle Lorenz, Shikha, Ryan Thome, Chris Wegener Client: Dr. Daniel MullerAdvisor: John Webster.
The Nervous System OR… Why you are able to poke yourself in the eye.
Biomedical Electrodes, Sensors, and Transducers
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
Aga Khan University Hospital Karachi
What is EEG ? An electroencephalograph (EEG) is the recorded electrical activity generated by the brain. In general, EEG is obtained using electrodes placed.
ACTION POTENTIALS Chapter 11 Part 2 HONORS ANATOMY & PHYSIOLOGY.
8.2 Structures and Processes of the Nervous System
OUTLINE Introduction of BCI EEG signal SSVEP BCI System Application.
Grounding.
Chem. 133 – 2/11 Lecture. Announcements Lab today –Will cover 4 (of 8) set 2 labs (remainder covered on Tuesday) –Period 1 will extend one day Website/Homework.
Methods of Control Animals are very complex organisms with many cells to coordinate. This coordination and control is performed with 2 different systems.
Biomedical Instruments Design 475 BMIS. Medical Instrumentation Design of instrument must match Measurement needs (environmental conditions, safety, reliability,
Essentials of Electroencephalography Groundwork Jarrod Blinch May 17 th, 2011 Comprehensive presentation.
Electromyography E.M.G..
Biomedical Instruments Design
Patch Clamp Technique Basic Concepts What is this poster about? Bioelectrical signals are transient pulsations propagated throughout the membrane of living.
Electric Pressure Transducer
Physiologic signals Lecture (2).
Biomedical Instruments Design Biopotential Amplifiers
Three types electrodes are used for sensing of EMG signals:
Grounding.
Chapter 5: Signals and Noise
Experimental methods in nerve muscle physiology
Lecture 1 Technological Principles of Medical Instrumentation
Technological Principles of Medical Instrumentation
Physiologic signals Lecture 6.
ECG ECG is a test that displays the electrical activity of heart muscles over a period of time. Detected with the help of electrodes attached to the outer.
Chem. 133 – 2/9 Lecture.
Electromyography E.M.G..
EPS Sensors & Hand Tracking/Gesture Recognition
Electromyography E.M.G..
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Biopotential electrodes
Electrical Current and the Body
Electrodes: 3 types Types: Micro electrode Depth & needle electrodes
Biopotential electrodes
Biomedical Instruments Design Biopotential Amplifiers 1.
Nervous Tissue.
Synaptic Transmission and Integration
Biomedical Electronics & Bioinstrumentation
Presentation transcript:

Introduction to the methodology of EEG recording Friday October 20th 2006

Summary A. Generators and modulators of EEG signal B. Understanding instrumentation C. Main ethical issues D. Physiological and electronical sources of noise E. Constraints for experimental protocols in EEG F. Configuration of EEG recording system and selection of montage G. Management of connectics H. Paste-up and problem solving during the recording session I. Digitization J. Cleaning/decontamination  of sensitive equipment / equipment maintenance

A. Generators and modulators of EEG signal

Generators of EEG signal When reached by an input, the presynaptic neuron: Releases some neurotransmitter in the synaptic cleft The dendritic process of the post-synaptic neuron: shows a local change in its membrane’s permeability generates a primary (intracellular) current from the locus of the synapse to the soma Generates a secondary/return extracellular current to close the loop

Generators of EEG signal Cortical pyramidal neurons, arranged in layers The movement of the ions is creating an open field (no cancellation) When a local community of tens of thousands of neurons are activated simultaneously by some input, a signal can be detected as far as at the surface of the scalp This signal is EXTREMELY tiny, and requires many precautions when measured

Generators of EEG signal And the miracle occurs

Modulators Age Vigilance Body temperature Hormonal cycles (women) Children: Changes in frequency content due to the size of the loops in the anatomical networks Changes in the conduction time due to myelinization Change in the amplitude of the signal due to myelinization Adult Increased variability over 40 Vigilance Chronopsychology (more details next) Drugs Caffeine Body temperature Hormonal cycles (women) Laterality

Modulators Circadian rhythms Global power is maximal during the afternoon Theta power has two peaks at 4pm and midnight Induced alpha is maximal in the afternoon Beta is maximal between 5pm and 7pm The modulation is dependent on the location of the electrodes

B. Understanding instrumentation

Overview Junction skin-electrode Analog conduction Differential amplifiers ADC Integration of triggers Transfer to the CPU / storage

Transduction The living tissues contain free ions The wire is conveying electrons The transfer of the signal from one material to the other requires a chemical transformation Oxidation or reduction (AC)

Transduction Eg. Ag / AgCl electrode: REVERSIBLE OXIDATION REDUCTION If an electron moves from the wire to the electrode toward the conductive gel: It reacts with AgCl e- + AgCl -> Ag + Cl- Cl- becomes hydrated and enters the conductive paste REDUCTION If ion moves from the conductive gel to the electrode: It reacts with solid Ag Ag + Cl- -> e- + AgCl AgCl becomes insoluble one electron is liberated to the wire REVERSIBLE e- e-

Transduction Eg. Ag / AgCl electrode: The Ag/AgCl electrode is non-polarizable (or minimally polarizable) POLARIZATION The anion (Cation) is unable to move freely across the gel/electrode border The concentration of ions at the border is altered. Ions concentrate over the border with the electrode and create a steady potential (bi-layer, capacitance) This steady potential hampers the movement of the charges This is important since the biopotential we intend to measure is in the range of 1/1000 of the half-cell potential (local potential at the junction between the conductive paste and the electrode)

Analog conduction As soon as the potentials are digital, they are immune to noise (not to deletion) Between the cap and the ADC, the minuscule currents are traveling through the cables and in the amplifier. Contamination through movements of the cables Contamination by cross-talk inside the amplifier and at the multiplexer of the ADC

Differential amplification We amplified to push the deflection of the pens (mechanical) We amplify to bring the signal in the range of the ADC (usually 0-1 to 0-5 V) But more importantly, the purpose is differential amplification…

Differential amplification Principle of differential amplification: the CMR (Signal + noise) – (noise) Take a scalp electrode (say C3) and a fixed point (GND) Measure one potential difference Take a reference electrode (say MA1) and a fixed point Measure a second potential difference (Signal + noise) – (noise) = “a very clean” signal

Differential amplification The ability of the amplifier to reject the common mode noise is called the CMRR

Differential amplification Amplifier Input impedance Separate the differential input with a high resistance

Analog-to-Digital Conversion Sampling frequency: Nyquist and aliasing

Analog-to-Digital Conversion Sampling frequency ADC range Quantization

Acquisition and storage Data acquisition and storage Reasonable sampling rate Backup

Understanding instrumentation Quikcap Headbox Power unit System unit

C. Main ethical issues

Electrical safety Security for the subject and security for the equipment Faulty connections Additional devices (response pads, sensors) Ground loops Static discharges Chassis leakage EMI in crossing wires Isolation amplifiers (Neuroscan system) are regulated by IEC 601-1 specifications. Additional devices connected to Neuroscan have to be detailed in the application to the EEG committee Order to plug or unplug the components

Infection risk Most of the supplies, especially those in contact with the subject (eg. needles), are disposable Any supply in contact with the subject does not return to the main. eg. the gel is sampled in a cup. Do NEVER refill a syringe in the main container. Moderate skin preparation: a subject should never be bleeding as a result of skin preparation. Inspection for the presence of blood after experiment (to choose the decontamination procedure) Decontamination of non-disposable equipment Is regulated by [American Electroencephalographic Society. Report of the Committee on Infectious Diseases. J Clin Neurophysiol 1994;11:128-132.].

Infection risk Object & Classification Use of Item Decontamination required after cleaning Critical Enters vascular system or sterile body tissues Sterilization and holding in sterilized state. High level disinfection is not sufficient Semi-Critical Comes in contact with non-intact skin or intact mucous membranes High level disinfection (by heat or chemicals) Non-Critical Comes in contact with intact skin Intermediate or low level disinfection Spaulding's classification of devices/medical instruments

D. Physiological and electronical sources of noise

Interferences Physiological artifact Instrumental noise Ocular domain Muscular domain EKG Respiratory Movement EDR/sweating Subjects’ instruction and online monitoring Instrumental noise EMI : wireless or line noise (60 Hz) Sway of the cable Electrodes poorly attached (pop) Electrode noise Amplifier noise Flicker noise (DC recordings!) Amplifier blocking Shielding and guarding

Interferences Artifacts from the ocular domain

Interferences GOOD BAD With proper alignment of EOG electrodes, horizontal EOG do not pick up the signal from vertical eye movements GOOD BAD 1 s

Interferences 1 s Saccade / eye movements

Interferences Muscles

Interferences How life could be easy without muscles

Interferences (and with enough time to average thousands)

Interferences EKG

Interferences Respiratory

Interferences Movement

Interferences EDR/sweating

Interferences Physiological artifact Instrumental noise Ocular domain Muscular domain EKG Respiratory Movement EDR/sweating Subjects’ instruction and online monitoring Instrumental noise Flicker noise (DC recordings!) EMI : wireless or line noise electrode noise amplifier noise Sway of the cable Electrodes poorly attached (pop) Amplifier blocking Shielding and guarding

Interferences A cell phone

Interferences Poor contact / Electrode pop

Interferences 60 Hz

E. Constraints for experimental protocols in EEG

Protocols Paradigms Evoked response Steady-state paradigms A single source of variation between conditions “All other things being equal” A good Stimulation/recording coupling “time accuracy in analog and digital stimuli/triggers” Subject screening Day-before instruction Accepting or rejecting a volunteer artifacts instruction, task instructions, Online monitoring of data quality and management of breaks

F. Configuration of EEG recording system and selection of montage

Configuration Configuration of data recorder (scan-acquire mode) Sampling frequency DC/AC recording (DC and EDR resident on the skin; DC and choice of electrodes) Triggers Selection of montage Only referential recording Reference electrodes Ground electrode Ancillary recording (EOG, surface EMG, EKG)

Montage 10 percent

Montage equidistant (eg. EGI)

Montage 128 NSL

Montage reference Choice of the reference electrode Cephalic/non cephalic Well-attached Single electrode or pair of electrode Pair physically or digitally linked Position of the ground In midline for ERL Remontage

Next session: practical session G. Management of connectics H Next session: practical session G. Management of connectics H. Paste-up and problem solving during the recording session I. Digitization J. Cleaning/decontamination  of sensitive equipment / equipment maintenance

G. Management of connectics

Cables everywhere Main cables are present in continuous Cables being specific to an experiment are removed after each experiment

H. Paste-up and problem solving during the recording session

Transduction Practical recommendation: Do not mix electrodes’ metal Do not mix gels homogenous contact skin-gel-electrode

Am I sure that there’s no damage to the wires? Amplifier’s gain error Electrodes impedance Poor impedance Is the electrode’s surface clean (eg did I perforate a crust into the electrode’s hole while injecting conductive gel?). Did I rub enough the scalp? Did the subject come with inadequate hair condition? Is the electrode filled enough? Infinite impedance Am I sure that there’s no damage to the wires? Amplifier’s gain error Poor signal on some electrodes

I. Digitization

J. Cleaning/decontamination  of sensitive equipment / equipment maintenance

Cleaning

Cleaning Equipment maintenance Troubleshooting / identification of noise source / Problem report