Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.

Slides:



Advertisements
Similar presentations
High Resolution Hadron Calorimetry with Dual Readout Adam Para, Fermilab Trends in Photon Detectors, Trieste, June 3, 2008.
Advertisements

SBS Hadron and Electron Calorimeters Mark Jones 1 TexPoint fonts used in EMF. Read the TexPoint manual before you delete this box.: AAA A.
LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Jin Huang Los Alamos National Lab.  Cited from March collaboration Meeting EC group Internal Communication Jin Huang 2 Preshower ID power drop significantly.
Adil Khan Kyungpook National university Korea-Japan Joint ScECAL Group Meeting kobe University Japan 3 rd September 2010.
SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
Could CKOV1 become RICH? 1. Characteristics of Cherenkov light at low momenta (180 < p < 280 MeV/c) 2. Layout and characterization of the neutron beam.
How to Build a Neutrino Oscillations Detector - Why MINOS is like it is! Alfons Weber March 2005.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
 Improve lepton-photon-hadron separation in the FMS to do  Some examples  J/Ψ physics in pAu and pp at forward rapidities  current status from chris.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
Adam Para, Fermilab, April 26, Total Absorption Dual Readout Calorimetry R&D Fermilab, Caltech, University of Iowa, Argonne National Laboratory,
Cost of a Large Solid Scintillator Detector Jeff Nelson Fermilab.
Study of response uniformity of LHCb ECAL Mikhail Prokudin, ITEP.
LCG Meeting, May 14th 2003 V. Daniel Elvira1 G4 (OSCAR_1_4_0) Validation of CMS HCal V. Daniel Elvira Fermilab.
ALCPG October 25 th 2007 Hans Wenzel Calorimetry in slic How-to Motivation for dual readout Calorimeter What are our requirements Why did we choose SLIC.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Planar Dual Readout Calorimetry Studies Progress Report G. Mavromanoulakis, A. Para, N. Saoulidou, H. Wenzel, Shin-Shan Yu,Fermilab Tianchi Zhao, University.
Implementing a dual readout calorimeter in SLIC and testing Geant4 Physics Hans Wenzel Fermilab Friday, 2 nd October 2009 ALCPG 2009.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
CALORIMETER system for the CBM detector Ivan Korolko (ITEP Moscow) CBM Collaboration meeting, October 2004.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
15-16 Oct 2005 Alice-USA meetingAleksei Pavlinov GEANT EMCAL geometry for ALICE current status Aleksei Pavlinov WSU.
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
STUDY OF ULTRAREAR DECAYS K 0 → π 0 νν(bar) (Search of K 0 → π 0 νν(bar) decay at IHEP, project KLOD ) V.N. Bolotov on behalf of the collaboration JINR,
Hadron Calorimeter HCAL-J GEp Electron Calorimeter BigCal Hadron Calorimeter 1 G. Franklin, Carnegie Mellon University 10/13/2011.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
Muon/Special Detector Studies Update St. Malo Muon ID - Single muons, single pion rejection. TESLA TDR (M. Piccolo) 2. Muon ID events:  ID efficiency,
13 July 2005 ACFA8 Gamma Finding procedure for Realistic PFA T.Fujikawa(Tohoku Univ.), M-C. Chang(Tohoku Univ.), K.Fujii(KEK), A.Miyamoto(KEK), S.Yamashita(ICEPP),
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
Rare decay Opportunities at U-70 Accelerator (IHEP, Protvino) Experiment KLOD Joint Project : IHEP,Protvino JINR,Dubna INR, Moscow, RAS.
CaTS and Dual Readout. CaTS – Calorimeter and Tracker Simulation Describe detector in gdml file (xml like) Define.
Quartz Plates R&D Status By F. Duru, S. Ayan, U. Akgun, J. Olson, Y. Onel The University Of Iowa V.Podrasky, C. Sanzeni, D.R.Winn Fairfield University.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
SPHENIX EMCAL R&D Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
Adam Para, Fermilab, February 16, Who Cares? What is the Problem? 2 Dual Readout Total Absorption calorimeter has very good energy resolution.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
18 Sep 2008Paul Dauncey 1 DECAL: Motivation Hence, number of charged particles is an intrinsically better measure than the energy deposited Clearest with.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
DEVELOPMENT OF THE POLYSTYRENE SCINTILLATOR TECHNOLOGY AND PARTICLE DETECTORS ON THEIR BASES VLADIMIR RYKALIN IHEP, PROTVINO INSTR-14, NOVOSIBIRSK, 24.
SuperB workshop SLAC, October 6, Outline Present Design Some thoughts about tile production Updated cost estimate Light yield studies of 3 mm thick.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
A possible BGO Setup for the 2008 Beam Test Campaign
COMPASS calorimeters S. Platchkov IRFU, CEA-Saclay GDR, 8-9 avril 2008
Where are we? What do we want to do next? Some thoughts
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Dual-Readout Calorimeter: DREAM
LCD-ALCPG Presentation at the ALCPG-SLAC Meeting
High Energy Neutrino Detectors Day 2
Dual readout calorimeter for CepC
LC Calorimeter Testbeam Requirements
Presentation transcript:

Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006

Definitions Construct a sampling calorimeter from alternating layers of ‘absorber’, thickness t abs and ‘active’ material, thickness t act. Both active and absorber are made of the same material (lead glass) Sampling fraction SF = t act /(t abs + t act ) represents the fraction of the total energy deposition (on average) deposited in the active layers. Estimate of the total energy deposition from the corrected observed energy in the active layers has an additional contribution due to ‘sampling fluctuations’: fluctuations of the sharing of total energy between the absorber and active layers 20 GeV pion beam t abs t act

Fluctuations of the energy deposition in the active layer – Sampling Fluctuations

Sampling Fluctuations Contribution to Energy Resolution

Fluctuations of the energy deposition in the Cherenkov radiator – Sampling Fluctuations

Energy Resolution

Corrected response

Response and Resolution as a Function of Sampling Fraction Corrected response is not a simple function of the sampling fraction, when active layer is small Physics?? GEANT4 feature? Sampling fraction represent a significant contribution to the energy resolution when the cherenkov radiator thickness is ‘large’ (>2.5 cm or so)

Response and Resolution as a Function of the Active Layer Thickness Corrected response problem at small active layer thickness seems to be related to the absolute thickness of the active layer and not to the sampling fraction

How Big a Test Calorimeter? Hadron calorimeters are large (m 3 ), hence expensive. Can’t afford to be bigger than necessary. (if we build it) we want to demonstrate good energy resolution ~(20-30)%/sqrt(E), that is ~2-3% energy resolution at 100 GeV. If the calorimeter is not long/wide enough there will be some energy leakage from the calorimeter and its fluctuations will contribute to the energy resolution. Need containment ~98% or better.

How Long a Calorimeter Need m long lead glass Blue = Cherenkov Red = ionization

How Wide a Calorimeter? Need ~ 1m wide test module Red = ionization Blue = Cherenkov

Available Building Blocks E70 experiment (Lederman, upsilon): SF5 lead glass blocks 6”x6”x16” 6” is far too thick. Optimal absorber thickness needs study (sampling fluctuations): 3” (thick)? 2”(thin)? Options 3 m = 120”: 40 thick planes 60 thin planes 7 x 6” = 105 cm wide 32”+12” = 110 cm tall 18 ‘pixels’ per plane Fundamental unit: lead glass + scintillator plate Transverse segmentation: Common LG and scintillator Is 6”x16” sufficient?

Readout? Assume: LG block and the scintillator plates are read out via a single waveshifting fiber (light collection efficiency and uniformity to be demonstrated) Channel count: 18 x 2 x 40 (60) = 1440 (2160) Assume Hamamatsu 5800-M64 phototube (?)  need 25(35) tubes Electronics? DAQ?

Cutting the Lead Glass Blocks Cut along the long axis: Diamond band saw Water-jet (with abrasives) Initial vendor contacts: promising Surface quality: do cut surfaces need to be polished (manpower = cost) Need to find out what the surface quality is Need to find out what is the acceptable surface quality