Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.

Slides:



Advertisements
Similar presentations
High Resolution Hadron Calorimetry with Dual Readout Adam Para, Fermilab Trends in Photon Detectors, Trieste, June 3, 2008.
Advertisements

Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Jin Huang Los Alamos National Lab.  Cited from March collaboration Meeting EC group Internal Communication Jin Huang 2 Preshower ID power drop significantly.
SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
Could CKOV1 become RICH? 1. Characteristics of Cherenkov light at low momenta (180 < p < 280 MeV/c) 2. Layout and characterization of the neutron beam.
How to Build a Neutrino Oscillations Detector - Why MINOS is like it is! Alfons Weber March 2005.
Doug Michael Jan. 12, First goal is to be ready to select an optimal technology in ~one year. –Demonstrate that fundamental technologies are ready.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Study of a Compensating Calorimeter for a e + e - Linear Collider at Very High Energy 30 Aprile 2007 Vito Di Benedetto.
C.Woody BNL sPHENIX EMCAL Conceptual Design sPHENIX Design Study Meeting September 7, 2011.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
Adam Para, Fermilab, April 26, Total Absorption Dual Readout Calorimetry R&D Fermilab, Caltech, University of Iowa, Argonne National Laboratory,
Cost of a Large Solid Scintillator Detector Jeff Nelson Fermilab.
Technology Choices for the sPHENIX Calorimeter Systems C.Woody For the PHENIX Collaboration CALOR12 Santa Fe, NM June 5, 2012.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Planar Dual Readout Calorimetry Studies Progress Report G. Mavromanoulakis, A. Para, N. Saoulidou, H. Wenzel, Shin-Shan Yu,Fermilab Tianchi Zhao, University.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
E.Kistenev Large area Electromagnetic Calorimeter for ALICE What EMC can bring to ALICE Physics and engineering constrains One particular implementation.
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
15-16 Oct 2005 Alice-USA meetingAleksei Pavlinov GEANT EMCAL geometry for ALICE current status Aleksei Pavlinov WSU.
Cherenkov Counters for SoLID Z.-E. Meziani on behalf of Simona Malace & Haiyan Gao (Duke University) Eric Fuchey (Temple University) SoLID Dry Run Review,
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
Scintillator ECAL for ILC for Calorimeter Review DESY May2007 Tohru Takeshita (CALICE-Shinshu) Idea implementation current status future mile stones.
STUDY OF ULTRAREAR DECAYS K 0 → π 0 νν(bar) (Search of K 0 → π 0 νν(bar) decay at IHEP, project KLOD ) V.N. Bolotov on behalf of the collaboration JINR,
Review of GlueX FCAL Design Richard Jones, University of Connecticut GlueX collaboration meetingSept , Newport News as presented by Scott Teige,
Hadron Calorimeter HCAL-J GEp Electron Calorimeter BigCal Hadron Calorimeter 1 G. Franklin, Carnegie Mellon University 10/13/2011.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
13 July 2005 ACFA8 Gamma Finding procedure for Realistic PFA T.Fujikawa(Tohoku Univ.), M-C. Chang(Tohoku Univ.), K.Fujii(KEK), A.Miyamoto(KEK), S.Yamashita(ICEPP),
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
4th Concept Pixel Vertex (PX) 20-micron pixels (like Fermilab/SiD thin pixel) TPC (like GLD or LDC) with “gaseous club sandwich” Triple-readout fiber calorimeter:
Rare decay Opportunities at U-70 Accelerator (IHEP, Protvino) Experiment KLOD Joint Project : IHEP,Protvino JINR,Dubna INR, Moscow, RAS.
first results from EMCal test beam
CaTS and Dual Readout. CaTS – Calorimeter and Tracker Simulation Describe detector in gdml file (xml like) Define.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
SPHENIX EMCAL R&D Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
Adam Para, Fermilab, February 16, Who Cares? What is the Problem? 2 Dual Readout Total Absorption calorimeter has very good energy resolution.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
1/28 VISITS TO COMPASS / NA58 Seminar for guides 9 March 2005 Susanne Koblitz Gerhard Mallot.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
DEVELOPMENT OF THE POLYSTYRENE SCINTILLATOR TECHNOLOGY AND PARTICLE DETECTORS ON THEIR BASES VLADIMIR RYKALIN IHEP, PROTVINO INSTR-14, NOVOSIBIRSK, 24.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
COMPASS calorimeters S. Platchkov IRFU, CEA-Saclay GDR, 8-9 avril 2008
Where are we? What do we want to do next? Some thoughts
superB Detector Workshop I University of Perugia and INFN
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Jin Huang Los Alamos National Lab
SCINTILLATING DIGITAL HADRON CALORIMETER
Dual-Readout Calorimeter: DREAM
High Energy Neutrino Detectors Day 2
Dual readout calorimeter for CepC
LC Calorimeter Testbeam Requirements
Presentation transcript:

Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006

Why Test Calorimeter??? It is not yet proven, but it is quite plausible that a dual readout calorimeter may offer very good energy resolution for jets  simulation and analysis It is plausible that high enough light collection efficiency can be attained for Lead Glass + fiber, or Lead Glass + APD configuration  optical test laboratory It is plausible that cheap enough Lead Glass (or other Cherenkov radiator) can be produced  vendors contacts It is plausible that a realistic mechanical design of a large hermetic calorimeter can be produced  engineering studies We need to demonstrate the energy resolution, linearity and e/  response in the test beam

How Big a Test Calorimeter? Hadron calorimeters are large (m 3 ), hence expensive. Can’t afford to be bigger than necessary. (if we build it) we want to demonstrate good energy resolution ~(20-30)%/sqrt(E), that is ~2-3% energy resolution at 100 GeV. If the calorimeter is not long/wide enough there will be some energy leakage from the calorimeter and its fluctuations will contribute to the energy resolution. Need containment ~98% or better.

How Long a Calorimeter Need m long lead glass Blue = Cherenkov Red = ionization

How Wide a Calorimeter? Need ~ 1m wide test module Red = ionization Blue = Cherenkov

Available Building Blocks E70 experiment (Lederman, upsilon): SF5 lead glass blocks 6”x6”x16” 6” is far too thick. Optimal absorber thickness needs study (sampling fluctuations): 3” (thick)? 2”(thin)? Options 3 m = 120”: 40 thick planes 60 thin planes 7 x 6” = 105 cm wide 32”+12” = 110 cm tall 18 ‘pixels’ per plane Fundamental unit: lead glass + scintillator plate Transverse segmentation: Common LG and scintillator Is 6”x16” sufficient?

Readout? Assume: LG block and the scintillator plates are read out via a single waveshifting fiber (light collection efficiency and uniformity to be demonstrated) Channel count: 18 x 2 x 40 (60) = 1440 (2160) Assume Hamamatsu 5800-M64 phototube (?)  need 25(35) tubes Electronics? DAQ?

Cutting the Lead Glass Blocks Cut along the long axis: Diamond band saw Water-jet (with abrasives) Initial vendor contacts: promising Surface quality: do cut surfaces need to be polished (manpower = cost) Need to find out what the surface quality is Need to find out what is the acceptable surface quality