1 First observations on CsI -coated ThGEM in Trieste presented by Gabriele Giacomini phone meeting 06/08/2008.

Slides:



Advertisements
Similar presentations
An introduction to Ultraviolet/Visible Absorption Spectroscopy
Advertisements

General Characteristics of Gas Detectors
The Refractive Index of a Solid An unusual application of spectroscopy.
INFN Trieste, October 2008 Summary of measurements on: CsI coated ThGEM triple CERN.
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
1 First observations on CsI -coated ThGEM in Trieste presented by Gabriele Giacomini phone meeting 06/08/2008.
Micro MEsh GASeous Detectors (MicroMegas)
Gas Detector Developments Jin Li. Liquid Xenon case Liquid Xenon can be considered as a gaseous xenon of 520 atm. K.Masuda, S. Takasu, T.Doke et al. (Doke.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
S. Bricola, A. Menegolli, M. Prata, M.C. Prata, G.L. Raselli, M. Rossella, C. Vignoli INFN and University of Pavia - Via Bassi, 6 – Pavia – Italy.
1 Gas processes in OTP straw  Questions: HV limit SQS mode Gas gain ??? Location- O:\Data\Osotr1\Presentation3.ppt and O:\Data\Osotr1\chargestudy.ps V.
Prototype TPC Tests C. Lu 12/9/98 V = 0. Gas gain test for the low pressure chamber The chamber is constructed with the following parameters: D anode.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
Characterization of CF 4 primary scintillation Andrey Morozov.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Threshold ionization mass spectroscopy of radicals in RF silane discharge Peter Horvath 5/19/2004 Progress of experiments.
C.Shalem et al, IEEE 2004, Rome, October 18 R. Chechik et al. ________________RICH2004_____________ Playa del Carmen, Mexico 1 Thick GEM-like multipliers:
Cube Measurements Tent Crew. Scintillation BNL 241 Am Semi- collimated  Spectralon Diffuse UV Reflector SBD  -Trigger Scint. Light Poisson.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
1 Fulvio TESSAROTTO CERN, 23/04/ Contribution from Trieste UPDATE ON TRIESTE LAB. ACTIVITY The set-up to measure currents THGEM prototypes from ELTOS.
HPD Performance in the RICH Detectors of the LHCb Young Min Kim University of Edinburgh IoP HEPP Conference – April
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
1 Thomas K Hemmick May 17 th, The Gas Electron Multiplier: GEM Thomas K. Hemmick Stony Brook University.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Gas measurements and CsI photocathode studies at WIS Ilia Ravinovich November 2002 Weizmann Institute.
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
1 NA58 RICH Test Beam T10 sept.2014 Fulvio Tessarotto – Stefano Levorato Partecipants: Alessandria, Aveiro, Budapest, Calcutta, Freiburg, Liberec, Prague,
DEVELOPMENT OF A THGEM-BASED PHOTON DETECTOR FOR CHERENKOV IMAGING APPLICATIONS Silvia Dalla Torre INFN - Trieste On behalf of an Alessandria-CERN-Freiburg-Liberec-Prague-Torino-TriesteCollaboration.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Improvement of Infrared Lights Sensitivity on PZT EMITER Daisuke Takamuro, Hidekuni Takao, Kazuaki Sawada and Makoto Ishida.
1 IBF in aligned, misaligned and FLOWER THGEMs The IBF problem Standard THGEM configuration COBRA and extra electrode Misaligned holes FLOWER THGEM solution.
What we did up to now: Summary of the measurements performed up to now with the gas setup built for the THGEMs coated with the CsI. Photocurrent measurements.
1 Fulvio TESSAROTTO GDD meeting, CERN, 01/10/2008 Trieste THGEM news First indications from electrostatic simulation exercise Goals of the simulation Parameters.
12/12/09 MPGD 神戸大学 1 Yusuke Komatsu A B. Azmoun B, C. Woody B, K. Ozawa A University of Tokyo A,Brook Haven National Lab. B.
HBD Gas and QE Monitoring Craig Woody BNL HBD Working Group Meeting October 19, 2005.
GEM basic test and R&D plan Takuya Yamamoto ( Saga Univ. )
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
Please read Chapter 4 in Archer Textbook
1 Fulvio TESSAROTTO CERN, 20/03/ GDD Meeting - Contribution from Trieste FIRST LOOK AT THGEM IN TRIESTE LAB. The set-up to measure currents THGEM.
Ageing of large CsI photocathodes exposed to ionizing radiation in a gaseous RICH detector A. Braem, G. De Cataldo, A. Di Mauro, A. Franco, A. Gallas Torreira,
Itzhak Tserruya, BNL, May13, HBD R&D Update: Demonstration of Hadron Blindness A. Kozlov, I. Ravinovich, L. Shekhtman and I. Tserruya Weizmann Institute,
HBD Status for Run 10 C.Woody For the HBD Group Collaboration Meeting January 15, 2010.
Future Possibilities for Measuring Low Mass Lepton Pairs in Christine Aidala for the Collaboration Quark Matter 2002, Nantes.
Collection of Photoelectrons from a CsI Photocathode in Triple GEM Detectors Craig Woody Brookhaven National Lab B.Azmoun 1, A Caccavano 1, Z.Citron 2,
Collection of Photoelectrons from a CsI Photocathode in Triple GEM Detectors C. Woody B.Azmuon 1, A Caccavano 1, Z.Citron 2, M.Durham 2, T.Hemmick 2, J.Kamin.
Recent progress in large THGEM production On behalf of Trieste group and Rui de Oliveira (CERN) S. Levorato RD51 mini week1.
Real-time Ellipsometry on Cesium-Telluride Photocathode Formation
Quality-evaluation of Cesium Iodide photocathodes for the ALICE/High Momentum Particle Identification detector by means of a VUV-Scanner system Herbert.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
1 Fulvio TESSAROTTO GDD meeting, CERN, 01/10/2008 Trieste THGEM news New THGEM test in the COMPASS hall New THGEM test in the COMPASS hall Preparation.
Single GEM Measurement Matteo Alfonsi,Gabriele Croci and Bat-El Pinchasik June 25 th 2008 GDD Meeting 1.
Update on THGEM project for RICH application Elena Rocco University of Eastern Piedmont & INFN Torino On behalf of an Alessandria-CERN-Freiburg-Liberec-
BASIC SOLAR CELL TESTING Basic Structure of a Solar Cell.
1 HMPID Project Assembly & Tests of CsI QE monitors: VUV-scanner and ASSET Milestone: December 2002.
R&D on Hadron Blind detector, recent results Issues addressed: - gain limits in CF 4 with heavily ionizing particles - operation.
Mg Films Grown by Pulsed Laser Deposition as Photocathodes: QE and surface adsorbates L. Cultrera INFN – National Laboratories of Frascati.
Liquid Argon Purity Monitor Testing Bonnie Weiberg TRAC Program Summer, 2015 ICARUS clone made at FNAL (S. Pordes - FNAL May 13th 2006)
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
R&D activities on a double phase pure Argon THGEM-TPC A. Badertscher, A. Curioni, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, P. Otiougova, F. Resnati,
THGEM short results collection
Quality Control Chamber Production
standard THGEM versus FLOWER
THGEM: Introduction to discussion on UV-detector parameters for RICH
Same geometry, but different size of the rim
THGEM report – january, 22nd 2009
Detective Quantum Efficiency Preliminary Design Review
First observations on CsI-coated ThGEM in Trieste - ADDENDUM -
When this happens... We see this... 12/6/2018 Steve Wotton.
SPECTROPHOTOMETRY Applied Chemistry.
Presentation transcript:

1 First observations on CsI -coated ThGEM in Trieste presented by Gabriele Giacomini phone meeting 06/08/2008

2 In these preliminary measurements we used a deuterium lamp (AVALIGHT- DHS produced by AVANTES) to extract electrons from a CsI layer, coating the “top” surface of the ThGEM (type “C4”). This irradiation produces a DC current, which is measured by picoammeters ( Keithley and home-made). The amount of irradiation is not accurately known (since the lamp is not perfectly calibrated), then information about the gain cannot be extracted from these measurements. Irradiation level is chosen to avoid a fast ageing of the CsI layer, known to lose its quantum efficiency after a collected charge of ~ mC/cm 2.

3 ThGEM characteristics: ThGEM type C4: Size = 3 X 3 cm 2 Rim = 100  m Pitch = 0.8 mm thickness = 0.4 mm Top coated by CsI acting as photocathode (over 5  m of Ni and 0.02  m of Au) ( good quantum efficiency for  < 200 nm) CsI is damaged by moisture exposure, then the right procedure is to always keep the CsI layer under vacuum or clean atmosphere (~ < 20 ppm H 2 0 and O 2 ). In our case, only after CsI deposition (at CERN) the ThGEM has been put under a vacuum container, then suffering a short exposure. During the mounting operations, the unavoidable air exposure has been minimized by flushing N 2 over the CsI, besides keeping the whole duration as short as possible (< 10’). The CsI layer survived showing, as test # zero, sensitivity to environment solar UV and blindness to halogen lamp. CsI quantum efficiency  nm  (From L. Molnar – RICH 2007 Trieste)

4 Ar/CO 2 (70/30) In (N 2 while idle) Ar/CO 2 out (N 2 while idle) PicoAmmeter KEITHLEY HV in Cathode wires (almost invisible) THGEM top, coated with CsI High quality quartz window (HERAUS Suprasil II) The chamber

5 The set-up AVALIGHT-DHS Deuterium lamp The anode pads are covered by an Aluminum box, a BNC carries out the signal/current Optic fiber and its holder. The beam out of the fiber diverges and irradiates the whole quartz window.

6 Top: CsI coated Bottom Anode pads Quartz window Cathode wires 10 M  1 M  - HV Beam out from optic fiber signal/current gas in gas out 7 mm 0.4 mm 5 mm Just a sketch … h e-e-

7 Photoelectrons collected by cathode (grounded by Keithley picoammeter) and  V = -100 V, so electrons drift only towards cathode wires. anode  GND Scan in V top (then in E drift), keeping fixed  V 1000 V  ~ 1kV/cm Ar/CO 2 1 atm The collection efficiency is a monotonic function of the “Drift” Electric Field There are several effects: e - extraction efficiency from CsI depends on drift/diffusion inside CsI itself Potential barrier between CsI and “vacuum” depends on the Fields higher fields decrease the detrimental effect of electron backscattering on gas atoms/ molecules, accounting for a charge loosing Some gain at the cathode wires? Measurement of the photocurrent (no gain on THGEM) collection efficiency

8 Very rough estimation of the # of photons A current of 10 pA  ~10 8 e - /s, supposing 1/10th is extracted  10 9 /s e - produced The q.e. of CsI is very small at these wavelength (> 200 nm) - and it is wavelength dependent. So, let’s say we have /s photons impinging the CsI layer… With a spectrophotometer (AVAspec - AVANTES) we acquire the irradiance spectra of the Halogen and deuterium lamps. The light of the halogen photogenerates a DC current in a photodiode: knowing the light absorption in silicon, we are able to state – in first approximation - the number of photons emitted by the halogen lamp. Comparing the spectra, we should know the photons emitted by the deuterium lamp (1.5e13 for <300nm). We don’t like the shoulder on the left of the Deuterium spectrum: maybe it’s an artifact of the spectrophotometer making this measurement useless and wrong… An independent way to estimate the number of photons: ?

9  V scan (gain from ThGEM) In this set-up: Electrons collected by anode E drift (fixed) = 0 V/cm (but we measured I anode to be insensitive to E drift ) E induction (fixed) = 4000 V/cm Scan in  V, until multiplication occurs The graph shows three regions:  V < 250 : partial collection of electrons inside the holes 250 V <  V < 1000 V : enhanced collection inside holes but gain still ~ 1  V > 1000 V : multiplication (we gain a factor 2 every 80 V) In the last points the currents are huge (and time dependent) so we don’t stay for long times. - In this range, environment light too provides high current The currents reported are read immediately after the opening of the shutter, the currents then decrease with time, due to the well known polarization effects.

10 Wavelength response To study the response of CsI to a specific wavelength, we filtered the D2 light source with several narrow bandpass filters (450, 390, 340, 289, 239 nm). We measure again the anode current and we operate the THGEM while it multiplies:  V > 1000V The beam spot irradiates the filter, while the environment light is blocked by the black paper sheet, covering the quartz window. The chamber is blind at 450, 390 and 340 nm (as expected from CsI) but shows significant sensitivity at 289 and, more, at 239 nm.

11 Induction scan  V = 1550 V Keeping fix the  V (the gain), we are interested to the ratio : I anode / I total e.g., to decide the voltages in order to get: a good signal from the anode a trigger from the bottom. This ratio is a monotonic function of the induction field and saturates at quite high induction fields.

12  V scan - II With the 240 nm filter, we do again the  V scan – for two different V induction – reading the currents from anode, bottom, top and drift. V drift = 3000 VV drift = 4000 V I drift is ~ 0, altough E drift has a sign for which the cathode competes with the holes in collecting the electrons (V drift is constant). (E induction =4kV/cm) (E induction =6kV/cm) Increasing the gain, more electrons to BOTTOM

13  V scan (V cathode = 3 kV & E induction = 4 kV/cm) Time development of the currents  V = 1600 V  V = 1500 V  V = 1550 V  V = 1650 V For  V < 1600 V, the currents decrease after their initial value (nothing new) but for  V > ~ 1600 V the currents increase. ???A positive feedback due to some kind of bombardment of the CsI layer???

14 V cathode = 3kV & E induction = 4 kV/cm  V = 1600 V  V = 1650 V  V = 1700 V Time development of the currents  V scan (V cathode = 3 kV & E induction = 4 kV/cm) It’s a huge effect

15  V = 1550 V  V = 1650 V  V = 1600 V Voltage change Time development of the currents  V scan - II (V cathode = 4 kV & E induction = 6 kV/cm) The currents increase again at  V = 1600 V, so it’s the  V and not E induction or E drift responsible for this effect