Supercritical Fluid Chromatography Introduction : Supercritical Fluid Chromatography (SFC) is a hybrid of gas and liquid chromatography that combines some.

Slides:



Advertisements
Similar presentations
Isofocusing Chromatography Prepared by- Shirin Akhter.
Advertisements

Introduction to Chromatography
Gas Chromatography Introduction 1.) Gas Chromatography
Gas Chromatography There an be many parts to a gas chromatography system but the basic components include: An injection system. A column (controllable.
Capillary Electrophoresis and Capillary Electrochromatography
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Supercritical Fluid Chromatography and Extraction
PRINCIPLE AND INSTRUMENTATION OF CAPILLARY ELECTROPHORESIS
SFC and SF Extraction Intermediate between HPLC and GC SF are substances above their critical pressure and temperature (critical point SFs has great solvating.
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Biochemical instrumental analysis-7 Dr. Maha Al-Sedik.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
Wilkes University -CHM 342 Electrochromatography - A Hybrid Separation Technique Gel Filtration Chromatography + Capillary Electrophoresis = Electrochromatography.
High Performance Liquid Chromatography
Chromatography Separates components in mixture: Based on - polarity
SUPER CRITICAL FLUID CHROMATOGRAPHY
Created with MindGenius Business 2005® Supercritical Fluid Chromatography Supercritical Fluid Chromatography Supercritical fluids Occur above a critical.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Chapter 33 Supercritical-Fluid Chromatography
Types of Liquid Chromatography I. Ion Exchange Chromatography A. Factors influencing retention B. Suppressed ion exchange II. Partitioning Chromatography.
Factors affecting electrophoresis The electric field ·       Voltage. If the separation of the electrodes is d (cm) and the potential difference.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
ERT106 BIOCHEMISTRY PROTEIN TECHNOLOGY By Pn Syazni Zainul kamal.
Supercritical Fluid Chromatography Introduction : Supercritical Fluid Chromatography (SFC) is a hybrid of gas and liquid chromatography that combines some.
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Chromatographic Methods & Capillary Electrophoresis
CHAPTER 21 SUPERCRITICAL-FLUID CHROMATOGRAPHY, CAPILLARY ELECTROPHORESIS, AND CAPILLARY ELECTROCHROMATOGRAPHY Introduction to Analytical Chemistry.
Introduction to Chromatography Definition Chromatography is a separation technique based on the different interactions of compounds with two phases, a.
Gel electrophoresis is a method for separation and analysis of macromolecules(DNA, RNA and proteins) and their fragments, based on their size and charge.
Capillary Electrophoresis (CE) PHAR Lecture Objectives By the end of the lecture, students should be able to: 1.Illustrate the CE instrumental.
Chapter 23 Chromatographic Methods & Capillary Electrophoresis.
Created with MindGenius Business 2005® Capillary Electrophoresis Capillary Electrophoresis Advantages Only needs nL sample High speed and resolution, virtually.
By- Bhavya, Harsh, Harshvardhan, Namrata, Ronit and Vidhatri
Chapter 29 Supercritical Fluid Chromatography and Extraction.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 23 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Biochemical instrumental analysis - 8 Dr. Maha Al-Sedik 2015 CLS 332.
Principles Separation is carried out by applying a high potential (10-30 kV) to a narrow (25-75 pm) fused silica capillary filled with a mobile phase.
19-1 Supercritical Fluid Chromatography Theory Instrumentation Properties of supercritical fluid §Critical temperature àAbove temperature liquid cannot.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Electrophoresis Dr. Nikhat Siddiqi.
CAPILLARY ELECTROPHORESIS Prepared by Dr: Sherif A.Abdel-Gawad.
General Tests for Chemistry 101
HPLC.
Electrophoresis Chapter 3-Lecture 7
Introduction to Instrumental Analysis - Chromatography
Chapter 34 Miscellaneous Separation Methods. 34 A Supercritical fluid separations Supercritical fluids are an important class of solvents that have unique.
Analytical biochemistry lab KAU-biochemistry dep. L. Nouf Alshareef
Welcome To my presentation.
Instrumental Analysis
Organic Analysis Basic concepts. Elements and Atoms Fundamental building block of all substances is the element. Fundamental building block of all substances.
Principles of chromatography
1 Principles of Chromatography Chap Analytical Separations and Chemical Problem Solving If you, a researcher of a food company are asked to find.
Chromatography.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Lecture 9 Introduction to Capillary Electrophoresis Lecture 9- PHCM662-SS2016 Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Capillary electrophoresis. Principle of electrophoresis Electrophoresis is the process of moving charged molecule in solution by applying an electric.
ELECTROPHORETIC METHODS
Amino Acids, Peptides, and Proteins
Lecture 2   ELECTROPHORESIS Electrophoresis is a separation technique that is based on the mobility of the ions in an electric field.. it is a Greek word.
Supercritical Fluid Chromatography and Extraction
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
Principle of separation of different components:
Capillary Electrophoresis and Capillary Electrochromatography
Presentation transcript:

Supercritical Fluid Chromatography Introduction : Supercritical Fluid Chromatography (SFC) is a hybrid of gas and liquid chromatography that combines some of the best features of both Supercritical Fluid exist at temperatures and pressures above its critical temperature and pressure and have densities, viscosities and other properties that are intermediates between those of the substance in its gaseous and liquid state. Gas (STP)Supercritical FluidLiquid Density (g/cm 3 )(0.6-2) x Diffusion coefficient (cm 2 /s)(1-4)x (0.2-2)x10 -5 Viscosity (g cm -1 s -1 )(1-3)x10 -4 (0.2-3)x10 -2 Critical temperature temperature above which a distinct liquid phase does not exist regardless of pressure

Important Properties of Supercritical fluids – remarkable ability to dissolve large, non-volatile molecules ‚ e.g., supercritical CO 2 can dissolve n-alkanes containing over 30 carbon atoms ‚ related to their high densities – dissolved analytes are easily recovered ‚ equilibrate with atmosphere at relatively low temperatures ‚ e.g., analyte in supercritical CO 2 can be recovered by reducing the pressure and allowing the CO 2 to evaporate – no need for organic solvents ‚ environmentally friendly – inexpensive, innocuous and non-toxic – higher diffusion coefficients and lower viscosities relative to liquids ‚ faster and higher resolution separations

Advantages of SFC compared to LC and GC: - SFC can separate compounds that are not conveniently handled by GC or LC. ‚ non-volatile or thermally labile and ‚ contain no functional group that makes possible detection in LC using spectroscopic or electrochemical techniques < up to 25% of all separation problems fall into this category < examples include: polymers, fossil fuels, pesticides, foods, drugs, etc. - Separations are faster then LC - Run at lower temperature than GC - Beneficial in industrial scale purification Faster elution Reduction in peak width (p3) Reduction in elution time (4x)

Instrumentation : Instrumentation for SFC is very similar to ordinary HPLC equipment since the temperature & pressure requirements for supercritical fluids fall within the standard operation Two Major Differences – thermostated column oven ‚ requires precise temperature control of mobile phase (typically supercritical CO 2 ) – restrictor or back-pressure device ‚ required to maintain desired pressure in column ‚ pressure change to convert from supercritical fluid to a gas for transfer to detector

Effects of Pressure : Pressure increases results in reduced elution time  - increase in density of mobile phase - effects retention or capacity factor (k’) - pressure changes  analogous to gradient elution in LC and GC

Example 15: What properties of a supercritical fluid are important in chromatography?

Introduction : Electrophoresis is a technique in which solutes are separated by their different rates of travel through an electric field. - commonly used in biological analysis, particularly in the separations of proteins, peptides and nucleic acids Similar to chromatography, both involve separation by different rates of travel through the system, but: electrophoresis  different rates of travel are produced by an electric field chromatography  different rates of travel due to chemical interactions between the solutes and a stationary or mobile phase Electrophoresis

Theory : The migration rate of solutes in an electric field will depend on the size and charge of the solute, as well as other factors Retention The degree of retention, or rate of travel, of a solute in an electrophoretic system is given by: v =  E where: E = electric field strength v = Velocity of the solute in the electric field  = Electrophoretic mobility of the solute The value of  is a constant for a given solute under a particular set of experimental conditions and depends on the following: ‚ ionic charge on the analyte ‚ inversely proportional to frictional retarding factors: - size of analyte - shape of analyte - viscosity of medium Note: charge-to-size ratio of analyte is an important factor in its mobility  small/high charged molecules migrate faster; large/low charged molecules migrate slower

Packed-bed (slab) system Capillary system Efficiency : Electrophoresis may be performed in an open-tubular system (capillary) or in a packed- bed (slab)

Joule Heating: – uneven heating in the system by the electric field ‚ causes different points in the system to have different temperatures ‚ non-uniform mixing of solute and solvent – gives rise to peak broadening in electrophoresis – decrease band-broadening caused by Joule heating: ‚ use of packed-bed systems (or stabilizers)  prevents mixing of solvent from different regions of the system ‚ use of more efficient cooling  prevents the formation of thermal gradients Result of Joule Heating

Zone Electrophoresis : Involves applying narrow bands of sample to the electrophoretic system - common type of electrophoresis - buffer composition is constant throughout system - solutes can be totally separated in a reasonable amount of time into separate “zones” based on mobility - zones are separated by regions of buffer Load samples into each well Apply voltage across gel Visualize bands with UV light

Packed-bed (slab): – much work in zone electrophoresis uses packed-bed instead of open tubular supports ‚ avoids band-broadening from Joule heating and unstable density gradients – packed beds “stabilize” solvent in the system ‚ prevents mixing between different regions – common supports: ‚ cellulose acetate, paper, agarose and polyacrylamide gels – band-broadening caused by diffusion around particles of the packed bed – porous matrix may also result in molecules being separated according to size in addition to electrophoretic mobility  SEC Zone Electrophoresis :

Capillary electrophoresis (CE): – another type of zone electrophoresis – use of narrow open tubular supports or capillaries ‚ typically  m I.D. – narrow bore capillaries allows efficient removal of Joule heat from the system ‚ decrease band-broadening ‚ allows stronger electric fields to be used < faster migration of solutes  decreasing analysis time – easy to automate – very small sample sizes (nl) – no particles  no multiple paths – many types of detectors can be used in capillary electrophoresis ‚ Fluorescence or UV/Vis absorbance are commonly used

Capillary electrophoresis (CE):

CE separation of DNA mixtures Because of the extreme efficiency and narrow peaks produced by CE, it is an area of intense research - especially in areas of biotechnology and biochemical separations - very small sample requirements: - useful in separating and studying the ionic solutes present in single cells - screening of large chemical libraries for drug discovery - genome sequencing

Electroosmotic flow – all solutes, regardless of charge, will migrate towards the negative electrode of the system - feature of capillary electrophoresis - produced by the presence of negative charge on the surface of the capillary ‚ negative charge is produced by ionization of silanol groups on the capillary’s surface ‚ occurs at pH > 4-5 ‚ net positive charge must exist in solution to counter negative charge of capillary’s surface ‚ net positive charge of solution causes net migration toward the negative electrode - ALL solutes eventually pass detector, regardless of charge

Electroosmotic flow – all solutes, regardless of charge, will migrate towards the negative electrode of the system - flow profile is flat  no peak broadening ‚ pressure-driven flow in LC causes parabolic profile caused by boundary effects and inertia Direction of Electroosmotic flow Direction & velocity due to potential Overall direction & velocity  (electrophoretic)  (electrophoretic) +  (electroosmotic) Anode (+) Cathode (-)

Isoelectric focusing – pH affects charge which affects migration HA  H + + A - K a = [H + ][A - ] / [HA] For a protein composed of amino acids   Low pH (acidic) High pH (basic) pI isoelectric point (pI) - pH at which net charge on molecule is zero If plate has pH gradient, protein migrates until local pH = pI

Example 16: Three large proteins are ionized at the pH at which a capillary electrophoresis separation is carried out. If the ions are designated A 2+, B + and C 3+, predict the order of the elution?