The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.

Slides:



Advertisements
Similar presentations
New QC Procedure for Eichrom Resins: Why We’re Changing Joel Williamson, Jill Bernstein, Dan McAlister and Phil Horwitz Eichrom Technologies, Inc.
Advertisements

O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Using Eichrom Resins to Simplify the Analyses for Gallium Content and Atom Percent Fission.
Analysis of Actinide Elements from Large Environmental Samples
Buffer Capacity Lab.
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
Created with MindGenius Business 2005® LC Detection Systems (1) Generally the most expensive part of the instrument Depends on analyte properties, and.
A2 Physics - L.O. Jones 2007 – Information gathered from Wikipedia Critical Mass.
Development of a Novel Molecular Recognition Probe for the Detection of Phosphite in Natural Waters Alex Carlton 1,3, John A. Moss 2, Marc M. Baum 2, and.
1 WORKER SAFETY AND HEALTH PRACTICES AT GASEOUS DIFFUSION PLANTS IN THE DOE COMPLEX: RESULTS OF HISTORICAL INVESTIGATION ( ) Ronald Stolberg Office.
BACKGROUND: An American Chrome Plating Company (name withheld by request) performs chrome plating on work rolls which are used in the steel and aluminum.
Umair Saleem Methods in protein chemistry Hydrophobic interaction chromatography.
Rapid Actinide Analysis for Large Soil Samples
ACADs (08-006) Covered Keywords analytical balance, conductivity bridge with flow cell, inductively coupled plasma analyzer, in-line sodium monitor, ion.
ION EXCHANGE CHROMATOGRAPHY PREPARED BY- MD.MARUF HASSAN.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Analysis of Actinide Elements from Large Samples Henrieta Dulaiova Guebuem Kim Bill Burnett Florida State University and E. Philip Horwitz PG Research.
Atomic Emission Spectroscopy
D. P. DiPrete, C. C. DiPrete, and R. A. Sigg
Technical Updates on UTEVA, TEVA and TRU Resins
Quiz Time 05:00 04:0003:0002:0001:3001:0000:4500:3000:1500:00.
Lead Content in Toys Katrina Nowak Chemistry 4101 Fall 2008.
Rapid Separation Methods for Bioassay Samples S. L. Maxwell, III and D. J. Fauth Westinghouse Savannah River Site.
Detection of Copper in Wastewater Seth Holm Chem4101 December 2009.
Radionuclide Generators
Year 12 Chemistry.  An analytical technique is a method that is used to determine the presence and concentration of a chemical compound or chemical element.
T’Keyah Driskell & Lyric Williams
BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.
BIOCYANIDE DEMONSTRATION PROJECT Activity III ; Project 5.
Chapter 2: The Chemistry of Life Section 1: The Nature of Matter
Biochemical Oxygen Demand
The Determination of 226 Ra in Water Samples Anil H. Thakkar Eichrom Technologies, Inc. eichrom TECHNOLOGIES INC.
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Nuclear Energy. The Fuel: Uranium Present nuclear power plants consume U- 235 as fuel Uranium has 92 protons Two isotopes are important. U-235 has an.
Chapter 19 Acids, Bases, and Salts 19.3 Strengths of Acids and Bases
Application of a beryllium specific resin at the Y-12 National Security Complex YGG Darrin K. Mann, D.H. “Bo” Bowman, Thomas J. Oatts, and Vicki.
Determination of Sr-89/Sr-90 in primary cooling water
Significance Caffeine and ibuprofen may negatively affect plant growth.  Caffeine and ibuprofen generally exist at concentrations below 1 ppm in surface.
Analysis of Actinide Elements from Large Samples Henrieta Dulaiova Guebuem Kim Bill Burnett Florida State University and E. Philip Horwitz PG Research.
Radioactive Materials Analytical Laboratory Eichrom Technologies Inc. User Group Meeting May 2001 J.M. Giaquinto, L.D. Bible, D.C. Glasgow, J.M. Keller.
Ion exchange chromatography
Simplicity is the key Continuous purification of monoclonal antibodies L. Landric-Burtin Head of Downstream Processing Development, France Integrated Continuous.
00J ppt Rapid Extraction Methods for the Process Laboratory S. L. Maxwell, III V. D. Jones S. T. Nichols J. Satkowski M. A. Bernard Westinghouse.
General Engineering Laboratories Use of Eichrom Resins for Bioassay Pa-231 Bob Timm - GEL Tim Chandler - GEL Bill Burnett - FSU Mike Schultz - PerkinElmer.
Destructive Analyses Techniques for Safeguards Mary L. Adamic June 30, 2009 INL/CON
The Determination of 226Ra in Water Samples
Application of Method 1668A to the Analysis of Dioxin-Like PCBs and Total PCBs in Human Tissue and Environmental Samples Coreen Hamilton, Todd Fisher,
 Biomolecules are purified using purification techniques that separate according to differences in specific properties.
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
The Determination of Be in an Enriched Uranium Matrix YGG Darrin K. Mann, D.H. “Bo” Bowman, Thomas J. Oatts, and Vicki F. Belt Analytical Chemistry.
AFFINITY CHROMATOGRAPHY Presented By: Salma Al-Salman
Th, Pu & U Separation Using TEVA and UTEVA Resin
Prentice Hall © 2003Chapter 17 Chapter 17 Additional Aspects of Aqueous Equilibria.
Is There a Link Between Epizootic Lobster Shell Disease and Contaminants? Lawrence A. LeBlanc 1, L. Brian Perkins, and Deanna Prince 1 1 School of Marine.
New Extraction Chromatographic Resins or New Tools for the Tool Box E. Philip Horwitz and Daniel R. McAlister PG Research Foundation, Inc South Cass.
Aqueous Equilibria By: Chris Via. Common-Ion Effect C.I.E.- the dissociation of a weak electrolyte by adding to the solution a strong electrolyte that.
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
Rapid actinide measurements in environmental samples Dr Phil Warwick Geosciences Advisory Unit Southampton Oceanography Centre.
One-Column Separation and Analysis of Isotopic Am and Pu in Soil Samples Nidal M. Jadalla, Eberline Services, Albuquerque, NM Anil Thakkar, Eichrom Technologies,
Chapter 1: The Nature of Analytical Chemistry
Chromatography PlanarColumn Paper TLC (Thin layer chromatography)
An Improved Method for Determination of Ra-228 * Jamie Christoff & Bill Burnett Department of Oceanography Florida State University “The Double-Pass Approach”
Fundamentals of Analytical Chemistry Eighth Edition.
Anil H.Thakkar Eichrom Industries, Inc.. Darien, IL
The Determination of 226Ra in Water Samples
Automatic analysis of biological images
Technical Updates on TRU and TEVA Resins
National Air and Radiation Environmental Lab
Radiochemical Methods
Inductively Coupled Plasma
Presentation transcript:

The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister and E. Philip Horwitz PG Research Foundation, Inc S Cass Avenue, Suite 109 Darien, IL 60561

Acknowledgement Darrin K. Mann Analytical Chemistry Organization Y-12 National Security Complex P.O. Box 2009, MS 8189 Oak Ridge, TN

Outline Background Be  Why it’s important/a problem Current Method  How it can be improved Single column purification to remove all ICP-AES interfering elements Guard column options to increase capacity of method for U(VI) (Key) Method is pH sensitive  Easy colorimetric method to monitor Simple, fast, and reliable More detail in paper prepared for Talanta (copies available)

Beryllium Uses and Properties Lighter than Aluminum, Stiffer than Steel High heat adsorption Metal, alloys, salts and oxides used in a wide variety of industries Neutron moderators or reflectors in nuclear reactors Nuclear weapons components

Problems Associated with Beryllium Physical Problems (Expensive, Brittle) Health Hazard Chronic Beryllium Disease (CBD) No know cure (can only be treated) Produces scarring of lung tissue Chronic (average year latency period) 2-5% of population acutely sensitive Over 100 current and former DOE employees have CBD

Beryllium Monitoring Controlled by US Dept of Energy CBD Prevention Program (10CFR part 850) Requires monitoring of air and surfaces to determine Be risk Y-12 analyzed nearly 40,000 samples for Be in % more samples expected to be analyzed in 2004 Current method uses ICP-OES or GFAA on microwave digested samples sensitive to certain interferences

Problems with Current Method Interfering elements in the OES spectrum of Beryllium Beryllium lines very intense  method is very sensitive for the determination of beryllium Interfering lines from other elements could lead to false positives. Positive determination of beryllium leads to shut down of operation until cleanup.

Problems with Current Method Currently Interfering lines are corrected using inter element correction (IEC) Uranium is particularly spectrally rich Spectrum shifts depending on the degree of enrichment of the Uranium Method for removing OES interfering elements from samples desired Uranium in particular Several EXC Resins evaluated for their ability to purify Be samples

Uptake of Selected Elements on Dipex Resin Be retained at low acid and stripped at high acid Most interferences strongly retained over entire range Cr weakly retained over entire range Single column should purify Be from all interferences Uranium very strongly retained

Uptake of Selected Elements on Dipex Resin

Proposed Method for Beryllium Purification Prepare samples as before (Digest with H 2 SO 4 /H 2 O 2, dilute with HNO 3 ) Neutralize samples to pH 1-2 with sodium aceate Buffers to maximum pH of 4.5 Monitor pH with methyl violet or crystal violet pH Range over which separation is effective

Elution of Be and Selected Elements on Dipex Resin

Effect of Large Quantities of Uranium Uranium uptake on Dipex Resin is very high Large amounts of Uranium could consume resin capacity and reduce Beryllium yields. 50 mg of U reduces Beryllium yield to ~60%. 100 mg of U reduces Beryllium yield to 29% and leads to U in Beryllium fraction

Effect of Large Quantities of Uranium An LN2 Resin guard column effectively separates U from Be LN2 resin contains a substituted phosphonic acid

Effect of Large Quantities of Uranium Coupling an LN2 Resin guard column increases Uranium capacity without decreasing Beryllium yields or changing chemistry. Over 100 mg of Uranium does not decrease Beryllium yield or produce Uranium in Beryllium fraction. GC attached through load, rinse and strip

Effect of Large Quantities of Uranium An LN3 Resin guard column also removes U from Be and retains Be less than LN2. LN3 resin contains a substituted phosphinic acid

Effect of Large Quantities of Uranium Coupling an LN3 Resin guard column increases Uranium capacity without decreasing Beryllium yields or changing chemistry. Over 100 mg of Uranium does not decrease Beryllium yield or produce Uranium in Beryllium fraction. GC can be removed following rinse

Effect of Large Quantities of Uranium LN2 and LN3 Resins effectively increase the capacity for Uranium With LN2, the GC remains connected through the load, rinse and strip With LN3, the GC can be removed following the rinse

Conclusions Efficient, Reliable method for purifying Be from all ICP-AES spectral interfering elements has been found using a single column Method is compatible with current monitoring and sample digestion methods Method is robust and performs over a wide pH range pH can be monitored with indicator to ensure optimal performance Inserting a LN2 or LN3 Resin guard column increases U capacity without changing the chemistry or significantly decreasing Be yields. Dipex Resin currently available from Eichrom as Beryllium Resin