Fire Safety By Alicia Civile and Alexandra Fernandez.

Slides:



Advertisements
Similar presentations
NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
Advertisements

2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
OSHA Office of Training and Education
7 | Means of Egress (Life Safety Code)
General Requirements Number of exits must be adequate Usually at least 2 exits must be available for evacuation More than 2 exits are required if the.
Fire-Resistive Construction (2nd part)
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Summary of NFPA 101 Interior Finish Requirements
Fire Safety By Alicia Civile and Alexandra Fernandez ASSIGNMENT 5.
Emergency Action Plans
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Building CODES Arch 3011 Design Studio 1 Prof. Sargent Architecture Southern Polytechnic State University.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
of NFPA 101 Life Safety Code Administration Definitions General
ACCESSIBILITY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME ttl-Architects LLC 28.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Subpart E Means of Egress.
Coverage and definitions. (a) Every employer is covered
Smoke Control Fire-Rated Stairwells Fireproofing of Structural Components Egress Lighting Fire-Resistive Construction Elements Fire and Smoke Dampers Emergency.
Won’t count Won’t count Another quiz, in two weeks Another quiz, in two weeks The Quiz.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
Emergency Action Plans
EGRESS AND FIRE PROTECTION
If you hear the fire alarm sound, evacuate immediately! Check door for signs of fire Close doors behind you to prevent fire & smoke spread Keep storage.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Building Codes and Interior Design
Means of Egress and Fire Protection
NO EXIT (adapted from OSHA Office of Training and Education)
1/05 Means of Egress WAC School Safety Training.
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Safety Training Presentation
Means of Egress Chapter 4.
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
CLIC CES Meeting 14 jan 2009 A resume table for fire safety in LHC, and a possible scheme for other machine – part 1 CERN –SC Fabio Corsanego.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
ID 308 Construction + Materials IV: Construction Documents Prof. Brody Endicott College Systems Coordination.
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Exit Routes and Fire Protection
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
Fire-Resistant Materials & Assemblies Part 2 Chapter 5.
Area of Refuge It’s the Law!
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Means of Egress and Fire Protection
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Fire Safety By Alicia Civile and Alexandra Fernandez ASSIGNMENT 4.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Means of Egress Don Ebert- Risk Manager (509)
Mayor’s Office on Disability City and County of San Francisco Discussion of Common Design and Construction Errors.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Means of Egress and Fire Protection
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
SUBJECT :. BUILDING CONSTRUCTION TOPICS:. PASSIVE FIRE PROTECTION. IN
Safety and Prevention of Typical Fire Plan
Table of Contents for Subpart E Coverage and Definitions
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Emergency Evacuations: Multi-Level Apartments
29 CFR NFPA Life Safety Code
Presentation transcript:

Fire Safety By Alicia Civile and Alexandra Fernandez

Fire Safety Design & Objectives When a building is designed to resist the start and spread of a fire, designers protect not only the building itself and its contents, but more important the lives of people who occupy the building. To react safely to a fire emergency, a building occupant needs early warning, the means to extinguish a small fire, and at least two ways out of the building. Once a fire has started, people may only have a few minutes to get out safely. As a result, people may panic, but they need to get to a door immediately. The design of the building may help, or it may lead to a dead end, trapping them inside.

Fire Safety Design & Objectives Fire Safety Objectives T he most common fire safety objectives, in order of importance, are: 1. protection of life 2. protection of property 3. continuity of operation

Fire Safety Overview Fire Safety Provisions Alarms Barriers Dampers Fire Rated Doors Evacuation Plans Extinguishers / Extinguishing Systems

Fire Safety Overview Fire Safety Organizations NFPA National Fire Protection Association OSHA Occupational Safety and Health Administration ADAAG Americans with Disabilities Act Accessibility Guidelines USFA United States Fire Administration UL Underwriters Laboratories Fig. 1

Fire Safety Codes NFPA Codes NFPA101: Life Safety Code NFPA 70: National Electrical Code NFPA 72: National Fire Alarm Code NFPA 80: Standard for Fire Doors and Windows

Evacuation Egress ComponentDescriptionComment Exit access a clearly outlined pathway to exit Must remain clear of smoke; minimum clear wheelchair access of 32” Vertical Egress smoke proof towers, exterior and interior stairs and ramps Does not include elevators Horizontal Egress Doors leading directly outside, two hour fire rated enclosed hallways Special horizontal exits: internal firewalls with two fire doors swinging in opposite directions Exit Discharge Area outside exits leading to public way Exit discharge provisions rarely affect interior projects Binggeli Table 15-3 CODE PROVISIONS FOR EVACUATION OF LOW RISE BUILDINGS p331 Code Provisions for Low Rise Building Evacuation

Evacuation Escape Routes Stairs + Corridors: slow fire and guide occupants out of building Exits Objectives Offer more than one route out limit distance to exit

Evacuation Areas of Refuge Provides a safe place for those in need of assistance to await help. Should be free of smoke, gas, heat, and fire ADAAG titled areas of rescue assistance Horizontal Exit Does not lead to building exterior Leads to safety in separate part of building or adjoining building on same level

Evacuation Vertical Openings The vertical opening enclosures serve to delay the spread of fire and are vital in preventing the rapid flow of smoke, death-dealing gases, and superheated air throughout the building Stairs, elevators, ductwork, electrical wiring, piping chases Required to be enclosed with fire-rated walls Must include self closing fire rated doors on each floor

Evacuation Vertical Openings May include exterior exits that allow smoke & fire to escape outside Also, interior openings allow the smoke to rise away from occupants

Evacuation Outdoor Exit Routes Outdoor exit routes are permitted but must meet the minimum height and width requirement for indoor exit routes and must: Have guardrails to protect unenclosed sides if a fall hazard exists be reasonably straight and have smooth, solid, substantially level walkways Not have a dead-end longer than 20 feet

Evacuation Emergency Exits and Signage Exit or directional signs must be at: Exit doors Corridor intersections Exit stairways or ramps Interior and exterior exits must be marked exit signs must always be illuminated Exterior exit doors must open out

Evacuation Emergency Exits and Signage Exterior exit doors must have panic hardware Landings and stairs must have hand rails Exit routes must be adequately lighted Floor surfaces must be clear of all hazardous items that

Evacuation Fire Doors Fire doors include push bars, hinges, closing devices, latches Required in educational facilities Objective: Stall the spread of fire to allow for evacuation ADA requirement: push force required to open door must not exceed five pounds

Evacuation Corridors and Paths of Egress Exit route ceilings must be at least 7’6” high Exit access must be at least 28” wide at all points Placing equipment in corridors is not feasible Exit route doors must be unlocked from the inside

Materials Construction Materials Exit must be separated by fire resistant materials Construction materials which separate the exit from other parts of the workplace must have one-hour fire resistance-rating if the exit connects three or fewer stories Materials must be chosen according to their performance in standard test methods Objective: contain fire retain structural integrity

Fire Dampers + Draft Stops + Firestops Fire Dampers Part of HVAC ductwork Stops ductwork airflow during emergencies Controls smoke, heat, and fire from passing through ductwork Fire damper must be included when duct perforates fire rated assembly

Fire Dampers + Draft Stops + Firestops Draft Stops Bingelli states that they are “required in combustible construction to close off large, concealed spaces” Create independent spaces and prevent airflow Firestops Bingelli states they “restrict the passage of smoke, heat, and flames in concealed spaces” Protect pipes and wires which pass through walls

Compartmentation and Fire Barriers Compartmentation “Prevents the spread of fire, smoke, and heat beyond a restricted area of the building.” Preserves building and inhabitants Fire Barriers Fire rated structural elements Wall, ceiling, or floor systems Prevent the spread of fire and heat

Compartmentation and Fire Barriers Firewalls Stop the spread of fire from building to building or building sections 3-5 hour rating

Smoke Detection + Extinguishing Fire Alarm Systems Automatic fire alarm systems are regulatory in educational institutions Manual pull stations should additionally be present in case fire is noticed prior to system detection Smoke Detectors Prevent death from smoke and poisonous gas inhalation

Smoke Detection + Extinguishing Sprinkler Systems Require water supply and standby power NFPA 13: Standard for the Installation of Sprinkler Systems Send out water and sound alarm upon start of use Fire Extinguishers Stop small fires at their source Must be within 75’ of occupant

Works Cited Binggeli, Corky. (2009). Building systems for interior designers. Wiley. Fig1. [Untitled photograph of NFPA logo]. Retrieved September 1, 2010, from: