Page 1 PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Overview of SPIRE Photometer Pipeline Kevin Xu NHSC/IPAC on behalf of the SPIRE.

Slides:



Advertisements
Similar presentations
HAWCPol / SuperHAWC Software & Operations J. Dotson July 28, 2007.
Advertisements

Bruno Altieri September # 1 PACS photometer pipeline overview Bruno Altieri (ESA/HSC)
Pipeline calibrations of ACS data Max Mutchler Hubble Space Telescope Calibration Workshop October 2005.
ASI Review Padova ICC Contribution 1 WP3000 : Padova ICC Contribution Mattia Vaccari & Giulia Rodighiero & Gabriele Mainetti Department of Astronomy -
- page 1 July NHSC Mini-workshop PACS NASA Herschel Science Center PACS Photometer AORs How to Prepare an Observation with HSpot: 2 Science Use.
- page 1 NHSC PACS Web Tutorial PACS-401 NHSC/PACS Web Tutorials Running PACS Photometer pipelines PACS-401.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 SPIRE Photometer Data Reprocessing Bernhard Schulz (NHSC/IPAC) on.
PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 SPIRE Day team, goals, schedule, logistics Bernhard Schulz NHSC/IPAC.
PACS NHSC SPIRE Point Source Spectroscopy Webinar 21 March 2012 David Shupe, Bernhard Schulz, Kevin Xu on behalf of the SPIRE ICC Extracting Photometry.
PACS Page 1 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf.
SPIRE Consortium Meeting La Palma, Oct. 1 – SPIRE FTS Pipeline Trevor Fulton Blue Sky Spectroscopy, Lethbridge, Canada.
PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Photometer Extended Source Photometry Bernhard Schulz NHSC/IPAC on behalf of the SPIRE.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-202 (for Hipe 9.0) Level 0 to Level 2 processing: From raw data to calibrated.
Consortium Meeting La Palma October PV-Phase & Calibration Plans Sarah Leeks 1 SPIRE Consortium Meeting La Palma, Oct. 1 – PV Phase and.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The SPIRE Photometer and its Observing Modes Bernhard Schulz (NHSC/IPAC)
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-202 (for Hipe 8.0) Level 0 to Level 2 processing: From raw data to calibrated.
- page 1 NHSC – DP workshop – Feb – N. Billot PACS PACS Photometer Standard Pipeline Level 0 to Level 1 processing: From raw to calibrated data cubes.
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 SPIRE AOTs, Products and Quick Look Tools Bernhard Schulz NHSC/IPAC on behalf of the.
- page 1 NHSC – DP workshop – Feb – N. Billot PACS PACS Photometer Standard Pipeline Level 1 to Level 2 processing: How to make a map for point source.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 Roberta Paladini NHSC/IPAC Photometry Guidelines for PACS data.
PACS Hitchhiker’s Guider to Herschel Archive Workshop – Pasadena 6 th – 10 th Oct 2014 SPIRE Photometer Data Products Kevin Xu NHSC/IPAC on behalf of the.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 Roberta Paladini NHSC/IPAC PACS photometer maps: several flavors.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The PACS Photometer: Overview and Products Roberta Paladini NHSC/IPAC.
PACS Hitchhiker’s Guide to the Herschel Science Archive Pasadena, 6 th -10 th October 2014 Tuesday Introduction Agenda & Goals David Shupe User Support.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-402 (for Hipe 12.0) Level 1 to Level 2 processing: The JScanam pipeline Prepared.
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 Measuring Photometry from SPIRE Observations Presenter: David Shupe (NHSC/IPAC) on.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-201 (for Hipe 12.0) Level 1* to Level 2 processing: The High-Pass Filter pipeline.
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 The SPIRE Destriper Bernhard Schulz NHSC/IPAC on behalf of the SPIRE ICC 1.
Page 1 PACS NHSC Webinar: New SPIRE Features in HIPE 10 6 th March 2013, Pasadena What’s New in SPIRE Photometer Pipeline in HIPE 10 Kevin Xu NHSC/IPAC.
PACS page 1 NHSC Open Time Cycle 1 Observation Planning Workshop 3 rd - 4 th Jun 2010 – Bernhard Schulz SPIRE Overview Bernhard Schulz, Nanyao Lu, Kevin.
PACS Page 1 NHSC Workshop on HSA Data Oct 6-10, 2014 SPIRE Spectrometer Data Reduction: Special Cases Nanyao Lu NHSC/IPAC (On behalf of the SPIRE ICC,
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 SPIRE Broad-Band Photometry Extraction Bernhard Schulz (NHSC/IPAC)
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The PACS Spectrometer: Overview and Products Roberta Paladini NHSC/IPAC.
Page 1 PACS NHSC Webinar: New SPIRE Features in HIPE th Nov 2012, Pasadena Update on SPIRE Photometer Pipeline Kevin Xu NHSC/IPAC on behalf of the.
PVPhotFlux PACS Photometer photometric calibration MPIA PACS Commissioning and PV Phase Plan Review 21 st – 22 nd January 2009, MPE Garching Markus Nielbock.
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 HIPE Introduction and Setup for SPIRE David Shupe, NHSC/IPAC on behalf of the SPIRE.
- page 1 NHSC – DP workshop – Feb – N. Billot PACS Deglitching PACS Photometer Data Presentation based on tutorial PACS-402.
NHSC SPIRE Data School – Pasadena 28 th - 30 th June 2010 PACS page 1 SPIRE Imaging Fourier Transform Spectrometer (FTS) Pipeline Data Processing Nanyao.
Page 1 PACS NHSC Webinar: What’s New in HIPE 13 for SPIRE 19 th May 2015, Pasadena What’s New in HIPE 13 General Topics Bernhard Schulz (NHSC/IPAC) on.
CEA DSM Dapnia SAp Flux calibration of the Photometer Koryo Okumura, Marc Sauvage, Nicolas Billot, Bertrand Morin DSM/DAPNIA/Sap.
Data Processing Workshop NHSC, Pasadena, CA 02 – 04 February 2011 Stephan Ott VG #1 PACS Overview and new developments in.
NHSC Data Processing Workshop – Pasadena 25 8h 30 th June 2010 PACS page 1 Workshop Slides NHSC-SPIRE Team NHSC Data Processing Workshop Pasadena
Page 1 NHSC PACS Web Tutorial Babar Ali PACS 401 PACS photometer map-making with MADmap PACS-401 for HIPE 11 user release Version Babar Ali (NHSC)
NHSC PACS PACS Photometry and Errors Estimate Roberta Paladini (NSHC/Caltech) R. Paladini NHSC Archive Data Processing Workshop – August 26 th – 30 th.
PACS Photometer Standard Pipeline Level 0 to Level 1 processing From raw to calibrated data cubes B. Altieri (ESA/HSC), N.Billot (IPAC/NHSC) ESAC March.
PACS NHSC Data Processing Workshop Aug 26-30, 2013 Page 1 SPIRE Spectrometer Data: Calibration Updates, User Data Reprocessing, and Other Issues Nanyao.
Page 1 PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Issues with Photometer Data & How to Resolve them with HIPE Tools Kevin Xu.
PACS Page 1 NHSC Data Processing Workshop – Pasadena Aug 26-30, 2013 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf.
Page 1 NHSC PACS Web Tutorial PACS 301 nhsc.ipac.caltech.edu/helpdesk NHSC/PACS Web Tutorials Running the PACS Spectrometer pipeline for CHOP/NOD Mode.
NHSC Data Processing Workshop Aug 26-30, 2013 PACS Page 1 SPIRE Spectrometer Data Processing (The Pipeline) Nanyao Lu NHSC/IPAC (on behalf of the SPIRE.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-402 (for Hipe 13.0) Level 1 to Level 2.5 processing: The JScanam pipeline Prepared.
PACS page 1 NHSC SPIRE Data Processing Webinars 8 th Feb 2012 PACS page 1 Overview of SPIRE Photometer Pipeline C. Kevin Xu (NHSC/IPAC)
PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Preparing HIPE for SPIRE work David Shupe, NHSC/IPAC on behalf of the SPIRE ICC.
PACS ICC Readiness Review MPE, July 3/ Extended-DP 1/13 E. Sturm: Extended-DP Eckhard Sturm.
PACS page 1 NHSC SPIRE Data Processing Webinars 7 th March 2012 PACS page 1 SPIRE Photometer Map Making C. Kevin Xu (NHSC/IPAC)
New SPIRE features in HIPE 9.1 NHSC; Nov 28, 2012 PACS Page 1 What’s New in HIPE 9.1 ( SPIRE FTS) Nanyao Lu NHSC/IPAC (on behalf of the SPIRE ICC)
PACS Page 1 NHSC Workshop on HSA Data Oct 6-10, 2014 SPIRE Spectrometer: Pipeline Calibration Nanyao Lu NHSC/IPAC (on behalf of the SPIRE ICC, HSC & NHSC)
All-sky source search Aim: Look for a fast method to find sources over the whole sky Selection criteria Algorithms Iteration Simulations Energy information.
1 NHSC PACS NHSC/PACS Web Tutorials Running PACS photometer pipelines PACS-403 (for Hipe 13.0) Level 1 to Level 2.5 processing: The Unimap pipeline Prepared.
Page 1 PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 Reprocessing Scan Maps Kevin Xu NHSC/IPAC on behalf of the SPIRE ICC.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th – 10 th Oct 2014 Overview of SPIRE Photometer Data Reduction Pipeline Kevin Xu NHSC/IPAC.
Markus Nielbock (MPIA) – PACS Photometer Flux Calibration Herschel Calibration Workshop PACS Photometer Flux Calibration: Update Markus Nielbock (MPIA.
Markus Nielbock (MPIA) – PACS Photometer Flux Calibration EPOS Meeting PACS Photometer Flux Calibration Current Plans Markus Nielbock MPIA, 22 th February.
Markus Nielbock (MPIA) – PACS Point Source AOT Pipeline Herschel Science Demonstration Phase Data Processing Workshop PACS Point Source AOT Pipeline Tutorial.
SPIRE Flux Calibration: Implementation
The SPIRE Point Source Catalog (SPSC) Status
Herschel Calibration Workshop
PACS ICC Meeting #41 PACS Photometer
Overview and new developments in Herschel Data Processing
What’s New in HIPE 10.0 (SPIRE FTS)
Presentation transcript:

page 1 PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Overview of SPIRE Photometer Pipeline Kevin Xu NHSC/IPAC on behalf of the SPIRE ICC

PACS page 2 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 The Goal Show how SPIRE Photometer pipeline works (functionalities of major modules). Reference: “SPIRE Data Reduction Guide” in HIPE (under “Help”) or in:

PACS page 3 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug ’5’ Pipeline & Data Products Level 2.5 Data Product Level 3 Data Product Maps Maps of combined parallel observations with cross-scans Maps of overlap observations belonging to the same proposal New in HIPE 11 (only in archive data from HSA) Scan Map Pipe- line (for small- map, large-map, & SPIRE/PACS parallel modes). (in HIPE)

PACS page 4 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart A “reversed sequence” relative to the chain of data acquisition Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching

PACS page 5 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition significant for very bright sources

PACS page 6 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching flag thermistors affected by “signal jumps” A “reversed sequence” relative to the chain of data acquisition

PACS page 7 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition detect & remove glitches shared by multiple detectors

PACS page 8 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition Single detector deglitcher Alternative: σ-κ deglitcher

PACS page 9 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition FFT based (run after deglitch to avoid ringing)

PACS page 10 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition Include: (1) Non-linearity correction (2) Volt to Jy/beam conversion

PACS page 11 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching Remove 1/f noise due to T-drift A “reversed sequence” relative to the chain of data acquisition

PACS page 12 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching Remove 1/f noise due to T-drift A “reversed sequence” relative to the chain of data acquisition flag thermistors affected by “signal jumps” Exclude flagged thermistors

PACS page 13 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching FFT based A “reversed sequence” relative to the chain of data acquisition

PACS page 14 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Map Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition telescope pointing & orientation SPIRE detectors positions

PACS page 15 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Scan Pipeline Flow Chart Level 0.5 Products Photometer Detector Timeline Remove electrical crosstalk Electric crosstalk matrix Concurrent deglitcher Wavelet deglitcher Thermistor Jump detector Correct for electrical filter Convert to flux density Temperature drift correction Temperature derivatives LPF parameters Conversion table Correlation parameters First level deglitching A “reversed sequence” relative to the chain of data acquisition Destriper + NaiveMapper

PACS page 16 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Destriper: Offsets Removal Destriper: remove the relative offsets of timelines of individual bolometers by minimizing the dispersions in overlap sky pixels (using the Naïve-Mapper iteratively).

PACS page 17 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 SPIRE Naïve Mapper signal samplings Sky pixel Two options: (1) No weighting (pipeline default): Flux of a sky pixel is the simple average of all signal samplings (by all bolometers) in the pixel: f3f3 f1f1 f2f2 f4f4 f5f5 (2) Inverse variance (of instrument noise) weighted: Flux of a sky pixel is the inverse variance weighted mean of all signal samplings in the pixel, the variance is calculated using the white noise of the bolometer with which a given sampling is taken:,

PACS page 18 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Details on Level 2 Products Generation point source maps (PLW, PMW, PSW) extended emission maps sso maps (only for solar system objects) only for sso: change to extended emission calibraiton

PACS page 19 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Status of SPIRE Photometer Pipeline in HIPE 11.0 General assessment Overall, It works very well. In most cases, data from HSA are already of science quality! The official calibration accuracy is ±6% (4% from model, 2% RMS). An example (on the right): The image from HSA looks good. SPIRE 3-color map of NGC 5315 (a planetary nebula) (Public data taken from HSA)

PACS page 20 NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Summary SPIRE Photometer Scan Map Pipeline handles data in the following observational modes: Small Map, Large Lap, SPIRE/PACS Parallel Mode. Corrections for instrumental effects (between Level 0.5 and Level 1 products) follow a “reversed sequence” relative to the chain of data acquisition. The map-making (between Level 1 and Level 2 products) is carried out using a Destriper-NaiveMapper combination. The current pipeline (HIPE ) does a good job (“science ready”) in general. In subsequent talks, we will discuss how to use the “user pipelines” (HIPE scripts) and other tools in HIPE to resolve data problems caused by known issues.