PACS Page 1 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf.

Slides:



Advertisements
Similar presentations
Deconvolution Workshop – MPIfR, Bonn, D 2008 Dec 8 - page 1 HIFI Standing Waves Adwin Boogert, NHSC/IPAC, Pasadena, CA, USA.
Advertisements

1 Lites FPP-SP Initial Reduct SOT #17 Meeting, NAOJ, April Solar-B FPP Initial Data Reduction for the FPP Spectro- Polarimeter October, 2004 Bruce.
FMOS Observations and Data 14 January 2004 FMOS Science Workshop.
Bruno Altieri September # 1 PACS photometer pipeline overview Bruno Altieri (ESA/HSC)
→ Herschel data for absolute beginners Herschel Science Centre (ESAC)
- page 1 NHSC PACS Web Tutorial PACS-401 NHSC/PACS Web Tutorials Running PACS Photometer pipelines PACS-401.
HIFI Tutorial 3: Getting some basic science out A.P.Marston ESAC 27 June 2013.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 SPIRE Photometer Data Reprocessing Bernhard Schulz (NHSC/IPAC) on.
PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 SPIRE Day team, goals, schedule, logistics Bernhard Schulz NHSC/IPAC.
PACS NHSC SPIRE Point Source Spectroscopy Webinar 21 March 2012 David Shupe, Bernhard Schulz, Kevin Xu on behalf of the SPIRE ICC Extracting Photometry.
SPIRE Consortium Meeting La Palma, Oct. 1 – SPIRE FTS Pipeline Trevor Fulton Blue Sky Spectroscopy, Lethbridge, Canada.
PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Photometer Extended Source Photometry Bernhard Schulz NHSC/IPAC on behalf of the SPIRE.
Page 1 PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Overview of SPIRE Photometer Pipeline Kevin Xu NHSC/IPAC on behalf of the SPIRE.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The SPIRE Photometer and its Observing Modes Bernhard Schulz (NHSC/IPAC)
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 SPIRE AOTs, Products and Quick Look Tools Bernhard Schulz NHSC/IPAC on behalf of the.
PACS Spectrometer Spatial Calibration plan in PV phase A.Contursi D. Lutz and U. Klaas.
- page 1 NHSC – DP workshop – Feb – N. Billot PACS PACS Photometer Standard Pipeline Level 1 to Level 2 processing: How to make a map for point source.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 Roberta Paladini NHSC/IPAC Photometry Guidelines for PACS data.
PACS Hitchhiker’s Guider to Herschel Archive Workshop – Pasadena 6 th – 10 th Oct 2014 SPIRE Photometer Data Products Kevin Xu NHSC/IPAC on behalf of the.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 Roberta Paladini NHSC/IPAC PACS photometer maps: several flavors.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The PACS Photometer: Overview and Products Roberta Paladini NHSC/IPAC.
Herschel Open Time Cycle 1 DP workshop ESAC, March page 1 Pat Morris, NHSC HIFI Mapping Processing in HIPE.
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 Measuring Photometry from SPIRE Observations Presenter: David Shupe (NHSC/IPAC) on.
- page 1 NHSC PACS Web Tutorial PACS-302 NHSC/PACS Web Tutorials Running PACS spectrometer pipelines PACS-302.
NHSC PACS NHSC Herschel Data Processing Workshop Steve Lord August Intro to HIPE PACS Spectroscopy: Getting Fluxes and Maps.
Imaging Molecular Gas in a Nearby Starburst Galaxy NGC 3256, a nearby luminous infrared galaxy, as imaged by the SMA. (Left) Integrated CO(2-1) intensity.
PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 The SPIRE Destriper Bernhard Schulz NHSC/IPAC on behalf of the SPIRE ICC 1.
Spectroscopy with PACS M82 PACS line imaging from the SHINING team (Contursi et al First Results workshop talk) Phil Appleton and Dario Fadda for.
Page 1 PACS NHSC Webinar: New SPIRE Features in HIPE 10 6 th March 2013, Pasadena What’s New in SPIRE Photometer Pipeline in HIPE 10 Kevin Xu NHSC/IPAC.
Analysing SPIRE FTS spectra 1 Day 4: SPIRE Rosalind Hopwood.
PACS page 1 NHSC Open Time Cycle 1 Observation Planning Workshop 3 rd - 4 th Jun 2010 – Bernhard Schulz SPIRE Overview Bernhard Schulz, Nanyao Lu, Kevin.
NHSC HIFI DP workshop Caltech, 7-9 February page 1 Steve Lord Conversions of Intensity Scales and Frequency Units.
PACS Page 1 NHSC Workshop on HSA Data Oct 6-10, 2014 SPIRE Spectrometer Data Reduction: Special Cases Nanyao Lu NHSC/IPAC (On behalf of the SPIRE ICC,
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 SPIRE Broad-Band Photometry Extraction Bernhard Schulz (NHSC/IPAC)
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th - 10 th Oct 2014 The PACS Spectrometer: Overview and Products Roberta Paladini NHSC/IPAC.
Page 1 PACS NHSC Webinar: New SPIRE Features in HIPE th Nov 2012, Pasadena Update on SPIRE Photometer Pipeline Kevin Xu NHSC/IPAC on behalf of the.
PVPhotFlux PACS Photometer photometric calibration MPIA PACS Commissioning and PV Phase Plan Review 21 st – 22 nd January 2009, MPE Garching Markus Nielbock.
- page 1 NHSC – DP workshop – Feb – N. Billot PACS Deglitching PACS Photometer Data Presentation based on tutorial PACS-402.
NHSC SPIRE Data School – Pasadena 28 th - 30 th June 2010 PACS page 1 SPIRE Imaging Fourier Transform Spectrometer (FTS) Pipeline Data Processing Nanyao.
Page 1 PACS NHSC Webinar: What’s New in HIPE 13 for SPIRE 19 th May 2015, Pasadena What’s New in HIPE 13 General Topics Bernhard Schulz (NHSC/IPAC) on.
Overview, Spectrometer Products and Processing Philosophy Phil Appleton on Behalf of PACS Team PACS IFU Spectrometer.
NHSC Data Processing Workshop – Pasadena 25 8h 30 th June 2010 PACS page 1 Workshop Slides NHSC-SPIRE Team NHSC Data Processing Workshop Pasadena
Page 1 NHSC PACS Web Tutorial Babar Ali PACS 401 PACS photometer map-making with MADmap PACS-401 for HIPE 11 user release Version Babar Ali (NHSC)
NHSC PACS PACS Photometry and Errors Estimate Roberta Paladini (NSHC/Caltech) R. Paladini NHSC Archive Data Processing Workshop – August 26 th – 30 th.
PACS NHSC Data Processing Workshop Aug 26-30, 2013 Page 1 SPIRE Spectrometer Data: Calibration Updates, User Data Reprocessing, and Other Issues Nanyao.
Page 1 PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Issues with Photometer Data & How to Resolve them with HIPE Tools Kevin Xu.
PACS Page 1 NHSC Data Processing Workshop – Pasadena Aug 26-30, 2013 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf.
Page 1 NHSC PACS Web Tutorial PACS 301 nhsc.ipac.caltech.edu/helpdesk NHSC/PACS Web Tutorials Running the PACS Spectrometer pipeline for CHOP/NOD Mode.
NHSC Data Processing Workshop Aug 26-30, 2013 PACS Page 1 SPIRE Spectrometer Data Processing (The Pipeline) Nanyao Lu NHSC/IPAC (on behalf of the SPIRE.
PACS page 1 NHSC SPIRE Data Processing Webinars 8 th Feb 2012 PACS page 1 Overview of SPIRE Photometer Pipeline C. Kevin Xu (NHSC/IPAC)
PACS NHSC Data Processing Workshop – Pasadena 26 th - 30 th Aug 2013 Preparing HIPE for SPIRE work David Shupe, NHSC/IPAC on behalf of the SPIRE ICC.
THE ALMA ORION BAND 6 SCIENCE VERIFICATION DATA SPECTRAL LINE SURVEY - CONTENT AND DISCOVERY AVAILABLE FOR ALL SCIENCE Anthony J. Remijan ALMA Program.
PACS ICC Readiness Review MPE, July 3/ Extended-DP 1/13 E. Sturm: Extended-DP Eckhard Sturm.
- page 1 July NHSC Mini-workshop PACS NASA Herschel Science Center PACS Spectrometer AORs Phil Appleton 1Roberta Paladini.
PACS page 1 NHSC SPIRE Data Processing Webinars 7 th March 2012 PACS page 1 SPIRE Photometer Map Making C. Kevin Xu (NHSC/IPAC)
New SPIRE features in HIPE 9.1 NHSC; Nov 28, 2012 PACS Page 1 What’s New in HIPE 9.1 ( SPIRE FTS) Nanyao Lu NHSC/IPAC (on behalf of the SPIRE ICC)
PACS Page 1 NHSC Workshop on HSA Data Oct 6-10, 2014 SPIRE Spectrometer: Pipeline Calibration Nanyao Lu NHSC/IPAC (on behalf of the SPIRE ICC, HSC & NHSC)
NHSC HIFI DP workshop Caltech, 8-9 March page 1 Pat Morris, NHSC DP Webinar, 9 March 2012 HIFI Spectral Maps in HIPE.
- page 1 PACS Phil Appleton on behalf of the NHSC/HSC and the PACS ICC ; especially Bart Vandenbussche and Pierre Royer (KUL Belgium) Instrument Performance.
Page 1 PACS NHSC Data Processing Workshop – Pasadena 10 th - 14 th Sep 2012 Reprocessing Scan Maps Kevin Xu NHSC/IPAC on behalf of the SPIRE ICC.
PACS Hitchhiker’s Guide to Herschel Archive Workshop – Pasadena 6 th – 10 th Oct 2014 Overview of SPIRE Photometer Data Reduction Pipeline Kevin Xu NHSC/IPAC.
Markus Nielbock (MPIA) – PACS Photometer Flux Calibration Herschel Calibration Workshop PACS Photometer Flux Calibration: Update Markus Nielbock (MPIA.
Adwin Boogert, NHSC/IPAC, Pasadena, CA, USA
photometry and spectroscopy with PACS
JWST Pipeline Overview
COS FUV Flat Fields and Signal-to-Noise Characteristics
Observing and Data Reduction
SPIRE Spectrometer Data Reduction: Spectral Line Fitting
Overview and new developments in Herschel Data Processing
What’s New in HIPE 10.0 (SPIRE FTS)
Presentation transcript:

PACS Page 1 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 SPIRE Spectrometer Data Reduction: Mapping Observations Nanyao Lu NHSC/IPAC (On behalf of the SPIRE ICC) 1

PACS Page 2 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 Goals Overview of the SPIRE spectral mapping mode: AOR and the pipeline. SPIRE spectral cube visualization and analysis in HIPE (demo) –How to visualize the data? –How to extract a 1-d spectrum within an aperture? –How to generate a line intensity map? 2

PACS Page 3 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 SPIRE FTS Observing Modes 3 Spectral resolution: High Res: 1.2 GHz (0.04 cm -1) ; R= 1290 – 370; ΔV = 230 – 800 km/s; Medium: 7.2 GHz (0.24 cm -1); R = 210 – 60. Low: 25 GHz (0.83 cm -1 ); R = 62 – 18, Spatial sampling using an internal jiggle mirror (BSM): Sparse (1 BSM pointing; 2 beam spacing) Intermediate (4 BSM pointings; 1 beam spacing) Full (16 BSM pointings; 1/2 beam spacing) Telescope pointing: Single Pointing Raster (NxM) Any observation involving either BSM jiggling or telescope raster is defined as a mapping observation.

PACS Page 4 NHSC Data Processing Workshop – Pasadena Sept 10-14, BSM Jiggle Patterns

PACS Page 5 NHSC Data Processing Workshop – Pasadena Sept 10-14, Telescope Raster Maps SLW SSW A 3x3 telescope raster with BSM in intermediate spatial sampling

PACS Page 6 NHSC Data Processing Workshop – Pasadena Sept 10-14, Pipeline for Mapping Data Level-1 Spectra S(σ) Preprocess Cube Spatial Projection Level-2 Product: Spectral Cube A list of (ra, dec, spectrum) An algorithm to assign individual spectra to the adopted map pixels. The pipeline uses the Naïve algorithm. Regularly gridded spectral cube in units of W/(m 2 Hz sr). Collection of spectra per jiggle/raster position, in units of W/(m 2 Hz sr).

PACS Page 7 NHSC Data Processing Workshop – Pasadena Sept 10-14, The Naïve Projection in the Pipeline SSW: 2x2 raster with intermediate spatial sampling The average of spectral scans from the 3 independent pointings is taken to be the spectrum for this map pixel of 19”x19” (SSW).

PACS Page 8 NHSC Data Processing Workshop – Pasadena Sept 10-14, Coverage Map SSW coverage map in terms of spectral scans There could be holes, as a result of dead detectors. These map pixels have spectral values of NaN. Holes can be eliminated by making map pixel size larger.

PACS Page 9 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 Remarks By default, the outmost, vignetted detectors are not used in cube construction. Unlike photometer, there is only up to a few detectors within any map pixel. Thus, detector-to-detector calibration difference (i.e., flat fielding) is more important here. Residual telescope emission (of Jy as of HIPE 9.1) could be still present in the continuum of a spectral cube. It is still a work in progress as to how to properly measure the flux of an aperture- extracted spectrum for a discrete source (e.g., a small galaxy) in the map. –Surface brightness of a discrete source is always somewhat underestimated in a map. As a result, a flux extracted within a finite aperture needs a further aperture correction that depends on aperture size and the detailed (wavelength-dependent) beam profile. –For a point source in the map, its photometry is best done by going back to the appropriate Level-1 spectrum that centers on the target, and performing a point- source flux calibration. 9

PACS Page 10 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 Demo on Spectral Cube Analysis Tool Described in some detail in Herschel Data Analysis Guide, Chapter 6, that comes with your HIPE 9.1. It works on 3-d data cubes of data type “SpectralSimpleCube” or “SimpleCube.” What can you do with this tool? We demonstrate some of its capabilities: –Cube visualization and cropping. –Extract a 1-d spectrum of data type “Spectrum1d” from a spectral cube. The result can be, as you learnt in one of our previous webinars, analyzed using HIPE Spectrum Toolbox (e.g., to fit a spectral line). –Extract a 2-d spatial image of data type “SimpleImage” from a spectral cube. The result can be analyzed easily in HIPE or any existing tools outside HIPE. As an example, we will extract a CO line intensity map here. 10

PACS Page 11 NHSC Data Processing Workshop – Pasadena Sept 10-14, 2012 Demo on Spectral Cube Analysis Tool We use the following sample data: –OBSID = –NGC7023; HR, 2 repeats, full spatial sampling. 11