Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.

Slides:



Advertisements
Similar presentations
THE EXTERNAL HAZARD.
Advertisements

Radiation Safety Program Annual Refresher Training
Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
WORKING WITH X-RAYS Dr D E Dugdale October 2012 KEELE UNIVERSITY.
Radiation Protection Course
Liquid Scintillation Counter And Contamination Monitoring Training Presented by: Ali Shoushtarian Office of Risk Management October 2009.
Geiger-Muller detector and Ionization chamber
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (1/2) 3.Collider Experiments.
Radiation Safety Course Radiation Monitoring Heath de la Giroday Dispensing Chemist Radiation Safety Officer.
Detecting and Measuring Ionizing Radiation -2
4/2003 Rev 2 II.3.6 – slide 1 of 18 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 6Photographic.
Radiation Detection & Measurements - 1
Radiation Detectors / Particle Detectors
Scintillators. When radiation interacts with certain types of materials, it produces flashes of light (scintillation) Materials that respond this way.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Nuclear Physics: Radiation, Radioactivity & its Applications.
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Main detector types Scintillation Detector Spectrum.
Measurement and Detection of Ionizing Radiation
Instruments for Radiation Detection and Measurement
Intervention for Chronic and Emergency Exposure Situations Basic Concepts of Emergency Preparedness Personal Protective Equipment, Devices and Procedures.
2: Radiation Measurements
Radiation Detection and Measurement II IRAD 2731.
4/2003 Rev 2 II.3.1 – slide 1 of 30 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 1Ionization Chambers.
. 2 RCRS provides: Pick-up and delivery of meters Required 9-month calibration Preventive maintenance and repairs Shipping for extensive repairs RCRS.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Principles of Radiation Detection
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
DETECTION AND MEASUREMENT OF RADIOACTIVITY 1 NANIK DWI NURHAYATI,S.SI,M.SI.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Type of Material: Instrumentation Review
Dosimetry Sanja Dolanski Babić March, Ultrasound interaction with tissue.
CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
FISICA AMBIENTALE 1 Radioattività: misure 2 Lezioni Marie Curie.
FISICA AMBIENTALE 1 Radioattività: misure 1 Lezioni Marie Curie.
Half-life It's impossible to predict when a specific atom is going to decay, but you can predict the number of atoms that will decay in a certain time.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
ELECTRONIC PROPERTIES OF MATTER - Semi-conductors and the p-n junction -
3/2003 Rev 1 II.3.4 & 13-15a – slide 1 of 31 Part IIQuantities and Measurements Module 3Principles of Radiation Detection and Measurement Session 4,Liquid.
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
Radiation detection and measurement
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Session II.3.7 Part II Quantities and Measurements
Optoelectronics.
Detection of Radiation Contents: Geiger tubes Photo-Multiplier tubes Cloud Chambers Solid State devices.
3/2003 Rev 1 II.3.7 – slide 1 of 40 Session II.3.7 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities.
3/2003 Rev 1 II.3.5 – slide 1 of 23 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.3.5 Part IIQuantities.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
Topic 6 : Atomic and Nuclear Physics.
Ch 36 Radiation Protection Design
PAN-2013: Radiation detectors
CLRS 321 Nuclear Medicine Physics & Instrumentation I
First FRCR Examination in Clinical Radiology Diagnostic Radiology & Radionuclide Radiology (4b) Patient Dosimetry John Saunderson Radiation Protection.
Radioactivity – Outcomes
HEALTH PHYSICS INSTRUMENTATION
1 Principles of Radiation Detection Operational Radiological Safety Course U.S. Army Chemical Biological Radiological & Nuclear School Edwin R. Bradley.
Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Semiconductor Detectors
Radioactivity B. Sc. -III Feb Dr. Wagh G. S. M. Sc. M. Phil. Ph
Detecting Ionising Radiation
Film badge: Measure and record radiation exposure due to gamma rays, X-rays, and Beta particles. Permanent record Cheaper Energy dependence Fading film.
Film badge: Measure and record radiation exposure due to gamma rays, X-rays, and Beta particles. Permanent record Cheaper Energy dependence Fading film.
Film badge: Measure and record radiation exposure due to gamma rays, X-rays, and Beta particles. Permanent record Cheaper Energy dependence Fading film.
 To provide an overview of external and internal dosimeters used for accupationl radiation protection 
 To provide an overview of external and internal dosimeters used for accupationl radiation protection 
Presentation transcript:

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Interaction with Matter and X-rays interact with matter in 2 major ways: Ionisation: removal of an electron from an atom leaving an ion. Excitation: addition of energy to the atom, giving an excited state. We can take advantage of these properties to devise a range of detectors. In general detectors utilise one of the following principles: Ionisation in gases Ionisation in solids/liquids Changes in chemical systems

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Ionisation in Gases: The Ion Chamber

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation battery Low voltage (30 – 100 V) Air filled vented to atmosphere Radiation entering produces ion pair Ion pair drift to respective electrodes Produces very small current A Tissue equivalent (Z=7.5) Flat response to gamma energies Advantages: Used as a doserate monitor Can measure gamma > 12 keV and beta > 70 keV (with cf applied) Detects neutrons (~ 8% efficiency)

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Disadvantages: Low currents = expensive electronics Very slow response times Susceptible to high humidity or moisture Susceptible to air pressure changes Contamination by radioactive gases

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation The Geiger – Muller Tube

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Operation similar to ion chamber – gas ionisation Major Differences – Low pressure gas ~ Atm High voltage across electrodes > 500 V HV causes avalanche / cascade effect

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Advantages Higher currents = cheaper electronics required Easily replaceable tubes Audible and visible outputs Not susceptible to atmospheric changes – humidity etc Sensitive – best used as a contamination monitor Disadvantages Cannot be used as a doserate monitor Requires quenching to stop runaway cascade fragile end windows No energy discrimination

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Ionisation in solids/liquids Work on the principle of fluorescence (scintillation) Efficiency depends on electron density Sodium Iodide (NaI) has high electron density Liquid scintillation counters – use a solvent/fluor combination Semiconductor detectors

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Valence Band Conduction Band Single atoms or molecules display energy levels When these come together to form a solid the discrete levels become energy bands Top 2 bands are the Valence and Conduction Valence band is nearly full, conduction nearly empty Forbidden region has no electrons in pure crystal Size (in eV) of FR depends on type of solid Impurities or dopants introduce electron traps Excitation leaves the valence band with a hole Conduction electron drops down to the valence band emitting a photon of light Introduction of dopants increases the efficiency Forbidden gap electron trap

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Sodium Iodide: Used for gamma and X-rays Type 41 (gamma) energies > 25 keV Type 42b (x-rays) energies 5 – 60 keV

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Liquid scintillation counter: Sample (e.g. swab) dissolved in fluor/solvent cocktail Light flashes from excited fluor molecules detected by two pm tubes in a coincidence circuit Generally used for beta emitters

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Liquid Scintillation Counter - Advantages: Will detect tritium High efficiencies (30 – 100%) Can use biodegradable solvents Can count large batches of samples Generally very accurate Disadvantages: Bulky equipment – not portable Expensive Quenching Regular calibration required No in-situ counting

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Semiconductor Detectors Two main types Silicon or Germanium Generally used for gamma/X-rays Reverse biased diodes – typically p-i-n junctions Valence Band Conduction Band + - Typical reverse bias voltage of > 1000V Electrons excited from VB to CB are swept up by electric field - a current pulse Pulse size is prop. to energy of the radiation Detector/MCA combination = spectrometer

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Semiconductor Detectors: Advantages – Very high electron densities Very sensitive Electron/hole energy low (2.9 eV for germanium) Pulse height proportional to energy of radiation Spectrometer + isotope library = analysis of unknown sources! Disadvantages – Very expensive! – both crystals and electronics Require cooling (Ge to liquid nitrogen temperatures) Require long setup times Generally not portable – swab samples

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Demonstration

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Personal Monitoring Thermoluminescence Detectors – TLD Optically Stimulated Luminescence – OSL Film badges Personal Radiation Detectors - PRD

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Thermoluminescence Detector Valence Band Conduction Band Forbidden gap electron trap Similar mechanism to scintillation detector Use LiF or CaF crystals Impurities are introduced to form meta stable electron traps in the gap region Electrons will stay trapped until heated to 200 o C After heating electrons drop back to valence band emitting a flash of light – pm detector Dose received given by the glow curve Heating also zeros the TLD – reusable More expensive than other personal devices Accuracy is poor for low doses (+/- 15%) Memory effects

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Film Badge Dosimeters Photographic emulsion of silver halide deposited onto a plastic sheet When exposed to radiation the film will blacken (developed) Density of blackened area gives a measure of the dose received Combination of emulsions can increase the measurable dose range A set of filters used to discriminate between types of radiation Usually 4/5 filters – OW, Cu, Sn/Pb, Al, Plastic etc

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Film Badge Dosimeters Advantages – Cheap Permanent record Sensitive to low energy gammas - < 20 keV Discrimination Disadvantages – Messy developing chemicals Not as accurate as other techniques Degradation of film Only by used once

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Optically Stimulated Luminescence (OSL) Al 2 O 3 is the scintillation crystal Instead of heat a laser is used to stimulate the luminescence Luminescence is proportion to exposure Filters used for type discrimination Imaging filter used to determine static or dynamic exposure Photon sensitivity is 5 keV – 40 MeV Beta sensitivity is 150 keV – 10 MeV Exposure range 10 μSv to 10 Sv

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation OSL – Advantages Can be re-measured, allows archiving More accurate than TLD Large exposure range Long shelf life Disadvantages – More expensive 2 month wearing period

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Personal Radiation Detectors (PRD) Small portable devices designed to give an instant reading Generally use GM tube or solid state (silicon) Can set an alarm level Are not very accurate Can be expensive

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Suitability Tritium- only practical means is a wipe test - use swab which is soluble in scintillant - assume 10% pickup - swab area of 100 cm 2 - measure in a LSC ~ 30 – 60% efficient - LSC must be calibrated

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Suitability – beta emitters C 14, S 35, P 32, P 33 etc- portable GM mini monitor - use shielding to determine relative energy - also LSC for accurate results

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Suitability – X-ray / gamma emitters I 125, Cr 51, Na 22 etc – scintillation monitor