A Study of Time over Threshold (TOT) Technique for Plastic Scintillator Counter 高能物理研究所 吴金杰.

Slides:



Advertisements
Similar presentations
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Advertisements

1 MRPC detector as polarimeter for dEDM Characteristic of detector Time Resolution Electronics Possible R&D Plans D. Babusci, A. Ferrari, P. Levi Sandri,
Frank Geurts Rice University.  Time-of-Flight in STAR ◦ start & stop detectors in Run 9  Time-of-Flight Calibration ◦ upVPD ◦ Barrel TOF ◦ preliminary.
Figure 5. Histogram of the decay constant. Black curves: raw histograms; Blue curve: Gaussian fit to the histogram from the 20GS/s waveform; Red curve:
CHL -2 Level 1 Trigger System Fully Pipelined Custom ElectronicsDigitization Drift Chamber Pre-amp The GlueX experiment will utilize fully pipelined front.
Status of MRPC-TOF Wang Yi Department of Engineering Physics Tsinghua University, Beijing, China 1.
Track Fitting and Comparator Results Emu UC Davis Feb. 26, 2005 Yangheng Zheng University of California, Los Angeles  Motivation & Introduction.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
TOF Front End electronics
June/5/20081 Electronics development for fast-timing PET detectors: The multi-threshold discriminator Time of Flight PET system Contents 1. Introduction.
VELO Testbeam 2006 Tracking and Triggering Jianchun (JC) Wang Syracuse University VELO Testbeam and Software Review 09/05/2005 List of tasks 1)L0 trigger.
Patrick Spradlin, SCIPP trip to LLU, May 2, 2001 Detector Characteristics.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
RPC (Resistive Plate Chamber)
Study of 58Ni excited states by (p, p’) inelastic scattering
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Updates on GEMs characterization with APV electronics K. Gnanvo, N. Liyanage, K. Saenboonruang.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
1 TRD-prototype test at KEK-FTBL 11/29/07~12/6 Univ. of Tsukuba Hiroki Yokoyama The TRD prototype is borrowed from GSI group (thanks Anton).
Malte Hildebrandt, PSIMEG - Review Meeting / 1   e  Drift Chambers Charge Division Test Chamber Testsetup for Cosmics Chamber Construction.
NA62 Gigatracker Working Group Meeting 23 March 2010 Massimiliano Fiorini CERN.
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
1 Data Acquisition What choices need to be made?.
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
1 Geant4 Simulation :MCP PET 4’’(102mm) Scintillator ( LSO) 4’’(102mm) 10mm Glass( Borosilicate) PhotocathodeI(Carbon) Space(Vacuum) MCP(Alumina) Space(Vacumm)
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
长读出条 MRPC 性能研究 孙勇杰 Key Laboratory of Technology of Particle Detection and Electronics, USTC-IHEP, CAS Center of Particle Physics and Technology, USTC.
Takeshi Fujiwara, Hiroyuki Takahashi, Kaoru Fujita, Naoko Iyomoto Department of Nuclear Engineering and Management, The University of Tokyo, JAPAN Study.
Status of the ETL 9125FLB Photomultiplier Tubes Steve Bache UNC-Wilmington.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
LC Power Distribution & Pulsing Workshop, May 2011 Super-ALTRO Demonstrator Test Results LC Power Distribution & Pulsing Workshop, May nd November.
Performances of the KM2A prototype array J.Liu for the LHAASO Collaboration Institute of High Energy Physics, CAS 32nd International Cosmic Ray Conference,
SPring-8 レーザー電子光 ビームラインでの タギング検出器の性能評価 核物理研究センター 三部 勉 LEPS collaboration 日本物理学会 近畿大学 1.レーザー電子光 2.タギング検出器 3.実験セットアップ 4.エネルギー分解能 5.検出効率とバックグラウンドレート.
CBM-TOF-FEE Jochen Frühauf, GSI Picosecond-TDC-Meeting.
MuTr Chamber properties K.Shoji Kyoto Univ.. Measurement of MuTr raw signal Use oscilloscope & LabView Read 1 strip HV 1850V Gas mixture Ar:CO 2 :CF 4.
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
Siena, May A.Tonazzo –Performance of ATLAS MDT chambers /1 Performance of BIL tracking chambers for the ATLAS muon spectrometer A.Baroncelli,
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
ESS Detector Group Seminar Edoardo Rossi 14th August 2015
SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Study of scintillator detectors time resolution with different SiPM readout on T10 test beam.
RIGEL: an Rpc-like sIgnals GEnerator for Laboratory testing N.Montes P.Amado, P.Fonte, J.A.Garzón, A.Gil University of Santiago de Compostela -Spain- labCAF.
XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Aging test of high rate MRPC Wang Yi Department of Engineering.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
2013 核电子学 ASIC 技术研讨会, 2013/10/14 基于电流模的 MRPC 探测器读出 ASIC 研究 报告人:周新 指导老师:邓智.
Proposal for the after-pulse effect suppression  Observation of pulses and after-pulses  Shape measurement  Algorithm  Results  Efficiencies for after-pulse.
Status of BESIII and upgrade of BESIII
FSC status and plans Pavel Semenov IHEP, Protvino
Jinfan Chang Experimental Physics Center , IHEP Feb 18 , 2011
Alternative FEE electronics for FIT.
L. Ratti, M. Manghisoni Università degli Studi di Pavia INFN Pavia
Ioannis Manthos Laboratory of Nuclear & Particle Physics
Dr. Mikhail Runtso, Mr. Pavel Naumov,
Setup for measurements with SCT128 in Ljubljana: SCTA128VG chip
Spherical Measuring Device of Secondary Electron Emission Coefficient Based on Pulsed Electron Beam Kaile Wen Shulin Liu Baojun Yan Yuzhen Yang Yang.
LNF - Beam Test Facility Sept. 29 – Oct. 04
Conceptual design of TOF and beam test results
MRPC -High Time Resolution Detector R&D at USTC CHINA Chen, Hongfang 2001/Oct. Oct.2001, Beijing MRPC,USTC.
Performance of a Multigap RPC prototype for the LHCb Muon System
Deng Ziyan Jan 10-12, 2006 BESIII Collaboration Meeting
CLAS12 Timing Calibration
X. Zhu1, 3, Z. Deng1, 3, A. Lan2, X. Sun2, Y. Liu1, 3, Y. Shao2
BESIII EMC electronics
On behalf of CEPC calorimeter working group
A Multi-Threshold Method for TOF-PET Signal Processing
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
md-NUV PET project meeting
PID detector on BESIII Nov 27th, 2007 Yuekun Heng IHEP
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

A Study of Time over Threshold (TOT) Technique for Plastic Scintillator Counter 高能物理研究所 吴金杰

Outline Introduction Research method-wave analysis Signal characteristics Relative charge resolution by TOT Summary

Introduction to TOT (1) TOT-­Time Over Threshold Pulse width TOT is somewhat dependent the charge Different threshold Advantage: One of alternatives to charge measurement Simplify the electronics Reduce the cost Time over threshold

Introduction to TOT (2) Apply in gas detectors Multi-gap Resistive Plate Chamber of ALICE and STAR: NINO-Correction of front edge time walk Drift Chamber of CLEO-III: Relative charge resolution: 10% TOT for Plastic scintillator counter? The correlation between TOT and Charge? Relative charge resolution? Relative Charge resolution of CLEO TOT versus measured time

Research method-wave analysis To be measure TOT, Amplitude, Charge How? Chip? Based on CAMAC system? Wave analysis Using high quality oscilloscope sample rate 20 GS/s TOF module Scintillator EJ200 +R5924 Experimental setup

Pedestal, Noise, Rise time The data within the first 250 ns are noise without any particle passing through the scintillator counter Noise: 2.0 mV Pedestal: 2.2 mV Rise time:4.2ns A wave shape of pulse The noise spectrum Spectrum of rise time Reference to the design BESIII TOF electronics

Amplitude, Charge Spectrum of amplitude Spectrum of charge Charge versus amplitude The charge is obtained from the time integral of the current pulse

Distribution of TOT The distribution of TOT when the threshold is set to 65 mV 15% of the most probable value of amplitude The distribution of TOT when the threshold is set to 195 mV 45% of the most probable value of amplitude The distribution of TOT with different threshold

TOT VS Charge--threshold 65mV The relative charge resolution versus charge TOT versus charge Linear correlation between TOT and charge Relative charge resolution can reach 7%-18% when the threshold is set to 65mV The relative error of Q by TOT can be obtained by formula

TOT VS Charge--threshold 195mV The relative charge resolution versus charge TOT versus charge The correlation between TOT and charge Relative charge resolution can reach 4%-7% when the threshold is set to 195mV

Summary  A Study of TOT technique for Scintillator counter firstly  Wave analysis  The Characteristics of TOF module Pedestal, Noise, Amplitude, Charge, Rise time  Relative charge resolution From 7% to 18% (Threshold is set to 65mv) From 4% to 7% ( Threshold is set to 195mv)

Thanks