Improving the object depth localization in fluorescence diffuse optical tomography in an axial outward imaging geometry using a geometric sensitivity difference.

Slides:



Advertisements
Similar presentations
Capacitive Micromotor
Advertisements

Object Specific Compressed Sensing by minimizing a weighted L2-norm A. Mahalanobis.
Temporal-Spectral Imaging of Functional States Randall L. Barbour NIRx Medical Technologies LLC SUNY Downstate Medical Center 4 th NIH Optical Imaging.
Evaluation of Reconstruction Techniques
1 Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University.
Optical properties of parietal peritoneum in the spectral range nm Marina D. Kozintseva 1, Alexey N. Bashkatov 1, Elina A. Genina 1, Vyacheslav.
P. Venkataraman Mechanical Engineering P. Venkataraman Rochester Institute of Technology DETC2013 – 12269: Continuous Solution for Boundary Value Problems.
Electrical Resistance Tomography Quak Foo Lee Department of Chemical and Biological Engineering The University of British Columbia.
Trans-rectal near-infrared optical tomography reconstruction of a regressing experimental tumor in a canine prostate by using the prostate shape profile.
WARSAW UNIVERSITY OF TECHNOLOGY INSTITUTE OF HEAT ENGINEERING DIVISION OF AEROENGINES 3-D ELECTRICAL CAPACITANCE TOMOGRAPHY FOR FLAME VISUALIZATION Piotr.
Daria K. Tuchina, Alexey N. Bashkatov, Elina A. Genina, Vyacheslav I. Kochubey, Valery V. Tuchin Department of Optics and Biophotonics of Saratov State.
Boundary Element Method (BEM) Zoran Ilievski Wednesday 28 th June, 2006 HG 6.96 (TU/e)
Topics in Medical Physics Xiaoming Zheng, PhD. School of Dentistry and Health Sciences December 2009, Chengdu.
NUMERICAL INVESTIGATION OF WAVE EFFECTS IN HIGH-FREQUENCY CAPACITIVELY COUPLED PLASMAS* Yang Yang and Mark J. Kushner Department of Electrical and Computer.
Fluorescence Diffuse Optical Tomography (FDOT) Our group presented three-dimensional (3D) in vivo images of human breast cancer based on fluorescence diffuse.
Relevance Feedback based on Parameter Estimation of Target Distribution K. C. Sia and Irwin King Department of Computer Science & Engineering The Chinese.
PIERS, Hawaii, Oct Second Generation Microwave Imaging System: Phantom and Early Clinical Experience Paul M. Meaney, Dun Li, Qianqian Fang, Sarah.
Interaction of X-rays with Matter and Imaging
MCE 561 Computational Methods in Solid Mechanics
Introduction to Longitudinal Phase Space Tomography Duncan Scott.
Forward and Inverse Electrocardiographic Calculations On a Multi-Dipole Model of Human Cardiac Electrophysiology Craig Bates Thesis Advisor: Dr. George.
1 Numerical Shape Optimisation in Blow Moulding Hans Groot.
Travel-time Tomography For High Contrast Media based on Sparse Data Yenting Lin Signal and Image Processing Institute Department of Electrical Engineering.
Adjoint Method and Multiple-Frequency Reconstruction Qianqian Fang Thayer School of Engineering Dartmouth College Hanover, NH Thanks to Paul Meaney,
1 Numerical Shape Optimisation in Blow Moulding Hans Groot.
A study of relations between activity centers of the climatic system and high-risk regions Vladimir Penenko & Elena Tsvetova.
Proof of concept studies for surface-based mechanical property reconstruction 1. University of Canterbury, Christchurch, NZ 2. Eastman Kodak Company, Rochester,
So Far……  Clustering basics, necessity for clustering, Usage in various fields : engineering and industrial fields  Properties : hierarchical, flat,
Analysis and Design of Multi-Wave Dilectrometer (MWD) for Characterization of Planetary Subsurface Using Finite Element Method Manohar D. Deshpande and.
Advisor : Cheng-Hsin Chuang Advisee : Kai-Chieh Chang Department of Mechanical Engineering & Institute of Nanotechnology, Southern Taiwan University of.
MULTI-DISCIPLINARY INVERSE DESIGN George S. Dulikravich Dept. of Mechanical and Aerospace Eng. The University of Texas at Arlington
Christopher Mitchell The Cooper Union Fluorescent Microscopy, Eigenobjects, and the Cellular Density Project Christopher Mitchell The Cooper Union Stevens.
Akram Bitar and Larry Manevitz Department of Computer Science
Li HAN and Neal H. Clinthorne University of Michigan, Ann Arbor, MI, USA Performance comparison and system modeling of a Compton medical imaging system.
Extension of the BLT Equation to Incorporate Electromagnetic Field Propagation Fredrick M. Tesche Chalmers M. Butler Holcombe Department of Electrical.
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
Flowing Matter – COST Action MP1305, , Sofia NUMERICAL ANALYSIS OF THE STENOSIS EFFECTS ON THE BLOOD FLOW IN THE COMMON CAROTID ARTERY BIFURCATION.
We have recently implemented a microwave imaging algorithm which incorporated scalar 3D wave propagation while reconstructing a 2D dielectric property.
Introduction In positron emission tomography (PET), each line of response (LOR) has a different sensitivity due to the scanner's geometry and detector.
Imaging HIFU Lesions Using Ultrasound Andrew Draudt and Robin Cleveland Department of Aerospace and Mechanical Engineering, Boston University, Boston,
Ultrasound Computed Tomography 何祚明 陳彥甫 2002/06/12.
Anne-Sophie MONTCUQUET 1,2, Lionel HERVE 1, Jean-Marc DINTEN 1, Jérôme I. MARS 2 1 LETI / LISA – CEA, Minatec, 17 rue des Martyrs, Grenoble Cedex.
Laboratory for Product and Process Design Computer Assisted Design of Transport Processes in the Human Brain Laboratory for Product and Process Design,
Ultrasound Computed Tomography
Motivation The knowledge of tissue optical properties is necessary for the development of the novel optical technologies of photodynamic and photothermal.
HIGH FREQUENCY CAPACITIVELY COUPLED PLASMAS: IMPLICIT ELECTRON MOMENTUM TRANSPORT WITH A FULL-WAVE MAXWELL SOLVER* Yang Yang a) and Mark J. Kushner b)
Date of download: 6/20/2016 Copyright © 2016 SPIE. All rights reserved. CT-analog pharmacokinetic DFT: (a) sketch of phantom and the configuration of the.
MCS overview in radiation therapy
Date of download: 6/29/2016 Copyright © 2016 SPIE. All rights reserved. The schematic of the rotational probe in noncontact diffuse correlation tomography.
Date of download: 6/29/2016 Copyright © 2016 SPIE. All rights reserved. Potential imaging modes. (a) Each detector in a focal plane array measures the.
Rutherford Appleton Laboratory Requirements Consolidation of the Near-Infrared Channel of the GMES-Sentinel-5 UVNS Instrument: FP, 25 April 2014, ESTEC.
Date of download: 9/17/2016 Copyright © 2016 SPIE. All rights reserved. Experimental layout. (a) Schematic of phantom showing the cross-sectional and overhead.
Finite Element Modelling of the dipole source in EEG
MAN-522 Computer Vision Spring
Tomography for Intraoperative Evaluation of Breast Tumor Margins:
From: Automated voxel classification used with atlas-guided diffuse optical tomography for assessment of functional brain networks in young and older adults.
“ROSATOM” STATE CORPORATION ROSATOM
Excitation based cone-beam X-ray luminescence tomography of nanophosphors with different concentrations Peng Gao*, Huangsheng Pu*, Junyan Rong, Wenli Zhang,
APPLICATION OF COHESIVE ELEMENT TO BIMATERIAL INTERFACE
Tianshuai Liu1, Junyan Rong1, Peng Gao1, Hongbing Lu1
Requirements Consolidation of the Near-Infrared Channel of the GMES-Sentinel-5 UVNS Instrument: FP, 25 April 2014, ESTEC Height-resolved aerosol R.Siddans.
Sahar Sargheini, Alberto Paganini, Ralf Hiptmair, Christian Hafner
OPTICAL MONITORING OF PHOTOSENSITIZER DIFFUSION INTO TISSUE
The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection.
COLOR MAPPING OF ONE SPECIFIC VELOCITY OF A FLOW WITH COMPLEX GEOMETRY USING OPTICAL COHERENCE TOMOGRAPHY Potlov A.Yu, Frolov S.V., Proskurin S.G. Biomedical.
Mont-Carlo simulation of OCT structural images of subcutaneous
Volume 96, Issue 6, Pages (March 2009)
Vysakh Vasudevan*, N. Sujatha
Rajdeep Ojha1, Vimal Chander1, Devakumar2
Akram Bitar and Larry Manevitz Department of Computer Science
Presentation transcript:

Improving the object depth localization in fluorescence diffuse optical tomography in an axial outward imaging geometry using a geometric sensitivity difference method. Krishna Teja Tokala, 1 Daqing Piao, 1 Gary Xu, 2 1 School of Electrical and Computer Science Engineering, Oklahoma State University Department of Radiology, Medical School, University of Michigan, Ann Arbor, 48109

 Motivation  Improve decision making in prostate biopsy.  Principle Demonstration  FDOT in an axial outward imaging geometry.  Analytical Representation  The modification and enhancement.  Performance, Challenges and Future work  Simulation Results

 The prostate cancer is considered to be the most vexing problem in USA. 11% of the deaths caused by cancer are due to prostate cancer

 Zinc secretion from prostate cells is 10 times more than any soft tissue in the body.  Adenocarcinoma cells taken from prostate tumors have lost their ability to amass zinc.  Occurrence of this change is early in prostate malignancy.  Use of Zinc specific fluorophore.  Hence, we have a negative contrast target to be reconstructed and resolve the issues of depth localization while using FDOT. Ref: V. Zaichick, T. Sviridova, and S. Zaichick, "Zinc concentration in human prostatic fluid: Normal, chronic prostatitis, adenoma and cancer," International Urology and Nephrology 28, (1996).

Principle Demonstration Fluorescence Diffused Optical Tomography (FDOT) The FDOT technique we are using is governed by 2 coupled equations. 1 st equation is related to the excitation phase. 2 nd equation is related to the emission phase. Source Term Fluorescence absorption Quantum Yield Excitation Phase Emission Phase

Conventional Reconstruction  Depth Localization problem. Set Image Reconstructed Image

 The new reconstruction method involves pairing of the source- detectors. Set Image Ref: Guan Xu,Daqing Piao, "A Geometric- Differential-Sensitivity Based Algorithm Improves Object-Depth Localization for Diffuse Optical Tomography circular array Outward-Imaging,“ 40(1) Med. Phys January2013

Conventional MethodGSD Method The objective function to be minimized during the FDOT reconstruction using GSD is given by: [Diff] matrix performing the forward-pairing differentiation of the native sensitivity values is called the GSD operation matrix. GSD : “ Geometry Sensitivity Difference“ method Objective Function Change of optical properties

 The change in the optical properties of the medium at each iteration is : Conventional Method GSD Method Note that at each iteration the matrix is bigger compared to the conventional reconstruction and hence the computational time increases.

 So for a conventional reconstruction the Jacobian matrix at each iteration for a source- detector pair is given by i ={1,2,3…16} j = {1,2,3,…16} and <> = {1,2,3,….N} N is the number of nodes.  For the GSD method that we are implementing we perform the modification on this Jacobian matrix by forward pairing of the source or the detector measurements Conventional MethodGSD Method New Jacobian

 The Jacobian w.r.t the where m=1:16 Conventional MethodGSD Method Conventional Jacobian (J): Jacobian now is w.r.t the relative sensitivity difference of This is the [Diff] matrix.J

 The comparison of GSD to the conventional reconstruction method is well known.  We need to compare this GSD method with another methods which have active compensation of the depth variation of the update function.  In our study we compare the GSD method with DCA method which modifies the Jacobian by a weighting scheme. Ref: H. Niu, F. Tian, Z.-J. Lin, and H. Liu, “Development of a compensation algorithm for accurate depth localization in diffuse optical tomography," Opt. Lett. 35, (2010).

 The change in the optical properties at each iteration is given by: Where, Here M is the weighting matrix given by: GSD MethodDCA Method DCA: “Depth Compensation Algorithm” method

(g) Depth Sensitivity of the three methods. (d) Conventional Mesh (f) Sensitivity Difference (e) DCA weighting Mesh (b) (c) Fig (a)-(c) shows how the methods were implemented. (d)-(f) shows the 2-D sensitivity mapping (g) shows the 1-D depth sensitivity plot of the 3 methods.

 Circular Array of outward imaging geometry.  Inner radius of 10mm and outer radius of 50mm.  A FEM mesh with 7708 nodes and elements.  32 evenly distributed channels i.e 16 sources and 16 detectors.

 The sensitivity distributions, forward and inverse computations were realized based on NIRFAST with 16 source detector pairs on the inner boundary geometry.  Simulation studies were done on a single anomaly positive and negative contrast at 3 different depths and the 1-D reconstruction profile was extracted. The figure shows the fem modeled outward imaging geometry for 3 depth positions we are simulating. o1 denotes the tissue region and o2 represents the anomaly.

(A) Single positive target anomaly  The contrast of the anomaly is 3 times the background  The anomaly at three depths was considered, 15.5mm, 20mm, 25mm from the center of the geometry was considered.

(B) Single negative target anomaly  The contrast of the anomaly is 1/3 times the background  The anomaly at three depths was considered, 15.5mm, 20mm, 25mm from the center of the geometry was considered.

(A) Single positive target anomaly Anomaly position at 15.5mm from the center Conventional DCA GSD 1 dimension sensitivity profile

Anomaly position at 20mm from the center Conventional DCA GSD 1 dimension sensitivity profile

Anomaly position at 25mm from the center Conventional DCA GSD 1 dimension sensitivity profile

(B) Negative target single anomaly Anomaly position at 15.5mm from the center Conventional DCA GSD 1 dimension sensitivity profile

Anomaly position at 20mm from the center Conventional DCA GSD 1 dimension sensitivity profile

Conventional DCA GSD Anomaly position at 25mm from the center 1 dimension sensitivity profile

 The single anomaly target at different depths for both positive and negative contrast targets have clearly shows GSD outworks both the conventional and the DCA reconstruction methods.  Currently we are working on the dual anomaly targets at different azimuthal positions and at different depths. This work was supported by DoD Prostate Cancer Research Program through a grant #W81XWH