VCI - V. Conti February,19-24 2007 1 A TIME OF FLIGHT DETECTOR FOR THERMAL NEUTRONS FROM RADIOTHERAPY LINACS V. Conti, G.Bartesaghi, D.Bolognini, M.Prest,

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
Study of plastic scintillators for fast neutron measurements
Ion Beam Analysis techniques:
Radiation Detectors / Particle Detectors
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
Neutral Particles. Neutrons Neutrons are like neutral protons. –Mass is 1% larger –Interacts strongly Neutral charge complicates detection Neutron lifetime.
Nuclear Physics: Radiation, Radioactivity & its Applications.
Tumour Therapy with Particle Beams Claus Grupen University of Siegen, Germany [physics/ ] Phy 224B Chapter 20: Applications of Nuclear Physics 24.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Luminosity Monitors MICE Video Conference 7 May 2009 Paul Soler.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Photon and Energy Fluence
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Introduction to Nuclear Medicine
A (Quick) Survey of (Some) Medical Accelerators Dr. Todd Satogata Brookhaven National Laboratory SUNY Stony Brook PHY 684 – September 5, 2007  The NASA.
High spatial resolution measurement of depth-of-interaction of a PET LSO crystal Aliz Simon a László Balkay b, István Chalupa b, Gábor Kalinka a, András.
PAMELA Contact Author: CONFORM is an RCUK-funded Basic Technology Programme Charged Particle Therapy Treating cancer with protons and light ions Ken Peach,
INTRODUCTION : Imaging antiprotons INTRODUCTION : Imaging antiprotons First results of real time imaging of the high energy gamma rays coming from antiproton.
Integrated Science Chapter 25 Notes
Chapter 21: Nuclear Chemistry The study of nuclear reactions with an emphasis on their uses in chemistry and their effects on biological systems.
Fundamentals of Radiation
Chapter 31 Nuclear Energy; Effects and Uses of Radiation.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Tools for Nuclear & Particle Physics Experimental Background.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.
Nuclear Forensics: Neutron Activation & Radiography
Response of the sensors to different doses from tests in Israel Radiotherapy is used as a treatment in around 50% of cancer cases in the UK. Predominantly,
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
Page  1 A new method to measure 10 B uptake in lung adenocarcinoma in hospital BNCT D. Bolognini, E.M. Donegani, A. Mattera, M. Prest, S. Hasan E. Capelli,
Cancer Therapy and Imaging Cancer Therapy and Imaging Rob Edgecock STFC Rutherford Appleton Laboratory.
Topic 2 Atomic Theory SL+HL. Topic 2.1 The atom Position ChargeRelative Mass Proton; p + Nucleus 1+ 1 Neutron; n Nucleus 0 1 Electron; e - Cloud/orbitals.
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Advanced semiconductor detectors of neutrons
Systematic studies of neutrons produced in the Pb/U assembly irradiated by relativistic protons and deuterons. Vladimír Wagner Nuclear physics institute.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Experimental Studies of Spatial Distributions of Neutrons Produced by Set-ups with Thick Lead Target Irradiated by Relativistic Protons Vladimír Wagner.
10.1 Radioactivity Understand Radioactivity and distinguish between the types of decay.
Determining Radiation Intensity
M Asnal *, T Liamsuwan 2 and T Onjun 1 1 Sirindhorn International Institute of Technology, Thammasat University 2 Nuclear Research and Development Division,
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler.
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
Photoneutron Distributions around 18 MV X-ray Radiotherapy Accelerators using Nuclear Track Detectors Fazal-ur-Rehman, H. Al-Ghamdi, M. I. Al-Jarallah.
Development of Cryogenic Moderators Using a Small Proton Accelerator Yoshiaki Kiyanagi*, Fujio Hiraga, Takashi Kamiyama, Akira Homma, Fumiyuki Fujita and.
Course : Inorganic Pharmacy II Course code: PHR 107 Course Teacher : Zara Sheikh Radioactivity and Radiopharmaceuticals.
BNCT, a binary radiotherapy at cellular level
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Boron Neutron Capture Therapy: tecnica e sorgenti
Solar gamma-ray and neutron registration capabilities of the GRIS instrument onboard the International Space Station Yu. A. Trofimov, Yu. D. Kotov, V.
Fast neutron flux measurement in CJPL
Project Structure Advanced Neutron Spectrometer on the International Space Station (ANS-ISS) Mark Christl NASA/MSFC Oct 23, 2015 Honolulu, HI 1 1.
Triple GEM detectors : measurements of stray neutron.
Very High Energy Electron for Radiotherapy Studies
Diagnostics of FRIBs beam transport line
for collaboration “Energy plus transmutation”
Neutronics Studies for the Nab Experiment
Neutron Detection with MoNA LISA
1. Introduction Secondary Heavy charged particle (fragment) production
Performed experiments Nuclotron – set up ENERGY PLUS TRANSMUTATION
Computed Tomography (C.T)
Presentation transcript:

VCI - V. Conti February, A TIME OF FLIGHT DETECTOR FOR THERMAL NEUTRONS FROM RADIOTHERAPY LINACS V. Conti, G.Bartesaghi, D.Bolognini, M.Prest, S.Scazzi, P.Cappelletti, M.Frigerio, S.Gelosa, A.Monti, A.Ostinelli, G.Giannini, E.Vallazza, A.Mozzanica

VCI - V. Conti February, OUTLINE The Boron Neutron Capture Therapy and its future in a hospital environment A novel TOF detector : description and comparison with standard neutron detectors Spectra and flux measurements with a Clinac 2100 Simulation developments and comparison with data Conclusion

VCI - V. Conti February, RADIOTHERAPY The radiotherapy goal local control of the primary tumour Ideal situation : a large amount of energy deposited in the tumour volume and none in the surrounding healthy tissue Radiotherapy beams Electrons for superficial or semideep cancers Photons are useful to treat deep-seated tumours that is tumours located several cm below the skin surface DEPTH IN WATER (cm)

VCI - V. Conti February, Although the percentage of survival is increased in the years, some tumours have a very low five-year survival probability

VCI - V. Conti February, For localized tumours Hadron therapy BRAGG PEAK Hadron radiation : Negative pions, protons and light ions (e.g. helium, carbon, neon, silicon and argon nuclei) The dose increases with penetration depth from a low dose at the entrance to a sharp maximum at the end of the particle range Depth in water (cm)

VCI - V. Conti February, PROTON X-RAYS HADRON THERAPY ADVANTAGE but this treatment cannot be used for some kinds of tumour like Extended tumours (liver, stomach or lung) Radio-resistant ones (melanoma) Tumours surrounded by vital organs (brain)

VCI - V. Conti February, The BNCT : Boron Neutron Capture therapy The BCNT is an oncology radiotherapy treatment that exploits the capture of thermal neutrons by 10 B and the following emission of an α particle and a nucleus of 7 Li Four years after the discovery of neutrons in 1932 by Chadwick, Locker introduced the concept of BNCT

VCI - V. Conti February, specific drugs (BSH or BPA) are being developed for this purpose boron is delivered mainly in the tumoral cells Irradiating tumor cells with a thermal neutron beam thus producing heavy charged particles releasing their whole energy in the cell High damage only in the target cells healthy celltumor cell 10 B

VCI - V. Conti February, The BNCT requires: a high thermal neutron flux (> 5x10 8 n cm -2 s -1 ) with a low energy neutron spectrum (neutron energy < 10 keV) Up to now such a beam is produced only in nuclear reactors a reactor would be too expensive and too dangerous to be put inside a hospital to develop a neutron source that can be used inside a hospital for BNCT treatments PHONES PROJECT AN IDEA

VCI - V. Conti February, PhoNeS (PHOton NEutron Source) The aim of the PhoNeS project is to provide a competitive thermal neutron source using clinac radiotherapy Linacs, maximizing with a dedicated photo-neutron converter the neutrons produced by Giant Dipole Resonance (GDR) by a high energy photon beam (> 8 MeV) photo-neutron converter ( PhoNeS ) Accelerator head ( Clinac 1800, 2100 )

VCI - V. Conti February, high energy photons hit a high Z target fast neutrons are produced by GDR neutrons are slowed down by a moderating material neutron capture inside the device should be kept low with as low as possible gamma field To obtain a Photon Neutron Source useful for medical purposes the following requirements have to be fulfilled: a thermal neutron flux greater than 10 8 n cm -2 s -1 a fast neutron and gamma dose per thermal neutron lower than 2x Sv cm 2 n -1 Giant Dipole Resonance

VCI - V. Conti February, Different prototypes and simulation have been developed to optimize the following parameters: Photoconverter lead thickness Moderator shape and thickness Box of moderator material (D 2 O)

VCI - V. Conti February, MCNP-4B GN code Simulation WITH and WITHOUT PhoNeS prototype without PhoNeS with PhoNeS 34 % slow 76 % slow

VCI - V. Conti February, In this framework a development of neutron detection methods to evaluate neutron and gamma doses is of primary importance COMMERCIAL NEUTRON DETECTORS: TLD passive detector, it integrates the flux in a certain energy range over the whole measurement duration not real time, it needs a long calibration procedure, an annhealing cycle before the use and after the readout also sensitive to photons high dynamic range BUBBLE DOSIMETERS integrated measurement over time and energy not real time; they can be used only with low doses; the counting of the bubbles can introduce large systematic errors poor spatial resolution

VCI - V. Conti February, BF 3 COUNTERS real time readout not tissue equivalent geometry constraints MATERIAL ACTIVATION integrated measurement over time and energy a Ge or NaI detector nearby is needed Usually one sample per time. Almost real time

VCI - V. Conti February, BEAM TIME STRUCTURE Electrons (as well as secondary photons) are emitted in a 3-5 µs wide bunch at a Hz repetition rate (dose rate dependent) It means up to tens ms “empty” time between two following bunches In this time interval there are no more electrons or photons in the environment, only thermal neutrons survive a eV neutron has a speed of 2.2 mm/µs

VCI - V. Conti February, We are developing a real time neutron detector made of a scintillator coupled to a dedicated readout electronics Plastic scintillators are low cost and flexible detectors, historically used for fast neutrons but can be employed also for slow ones in this particular configuration of the beam For slow neutrons we can take advantage of the neutron capture by the hydrogen nuclei detecting the 2.2 MeV γ emitted in the reaction n + H D + γ ( 2.2 MeV)

VCI - V. Conti February, THE FIRST DETECTOR A polystyrene plastic scintillator 2x2x1 cm 3 Two P30CW5 photomultipliers by Electron Tubes with integrated high voltage power supply facing the two opposite sides of the scintillator to avoid dark counts and improve reliability The detector assembly

VCI - V. Conti February, Signals on the oscilloscope Our detection system should be able to return the number of captured neutrons and their arrival time The read out electronics The signals from the scintillator are digitized by a NIM discriminator, threshold 30 mV The coincidence between the two PMs is shifted to LVDS and then sent to sampler sampling the discriminated signal with a 12.5MHz clock

VCI - V. Conti February, This is an output example: each “1” corresponds to an impinging neutron For each experimental condition several bunches have been collected, obtaining a time arrival profile

VCI - V. Conti February, WE HAVE TWO GOALS: TO MEASURE The neutron number The neutron energy spectrum

VCI - V. Conti February, The comparison between the Al sample activation and the real time detector measurements in the scan along a diagonal from the accelerator head Measurement setup in S.Anna Hospital (Como, Italy)

VCI - V. Conti February, This detector can be used to measure the energy spectrum The TOF spectrum has been fitted with a double exponential and the result is : Two different slopes: 135 µs ms These constants represent the contribution of a slower and a faster part of the neutron spectrum. is it true?

VCI - V. Conti February, Scan of PMMA Accelerator head rotated of 90° detector PMMA layer the slow constant from the accelerator head material (lead) the fast constant from a plastic material in the room

VCI - V. Conti February, The fast component is affected by the PMMA, since The slow component doesn’t feel the effect of PMMA Ratio fast/slow More PMMA=more thermalization From the TOF of each point ….

VCI - V. Conti February, THE SECOND PROTOTYPE using a boron loaded plastic scintillator to evaluate an α and 7 Li contributions BC-454(Bicron) a boron loaded plastic scintillator diameter = 2 cm thickness=0.5cm P30CW5 photomultiplier by Electron Tubes The assembled detector

VCI - V. Conti February, Comparison of the scintillator data with the activation method and the simulation data DETECTOR DOSIMETER It counts the photons produced by the neutrons in the scintillator plus in all surrounding materials

VCI - V. Conti February, the neutron energy spectrum is extracted from the simulation TOF The TOF simulation comparison with data This is a very important result for a BNCT treatment you need the information on the spectrum

VCI - V. Conti February, CONCLUSION BNCT in hospitals? … a dream becoming reality … A real time detector made of standard plastic scintillator that is both a relative DOSIMETER and a SPECTROMETER Can be used as a dosimeter at reactors? Flux measurement = real time equivalent of attenuation Boron doped scintillating fibers or very thin scintillators that will allow to disentangle the contribution due to the photons produced by neutron capture in the surrounding materials. OUTLOOKS Absolute dose computation both with Linac and reactors Fiber system development Measurements with Phones with different Linacs

VCI - V. Conti February, A TIME OF FLIGHT DETECTOR FOR THERMAL NEUTRONS FROM RADIOTHERAPY LINACS V. Conti, G.Bartesaghi, D.Bolognini, M.Prest, S.Scazzi, P.Cappelletti, M.Frigerio, S.Gelosa, A.Monti, A.Ostinelli, G.Giannini, E.Vallazza, A.Mozzanica