WATER  Water is most abundant, useful & misused one  It is universal solvent Uses :  Domestic purposes : Cooking, bathing, Drinking  Industries : Boilers,

Slides:



Advertisements
Similar presentations
Hard Water & Soft Water.
Advertisements

Water is one of the most important substances on the Earth from more than millions of years ago, taking up three quarters of the planet surface.
1st SEM Applied Chemistry
Water CHEMISTRY 2 Additional Science Chapter 8. The Importance of Water Water is essential to life on Earth Water is used widely as a solvent in industrial.
HARD WATER AND SOFT WATER
CE 547 Softening. What is Hardness Hardness is –the ability of the water to consume excessive amounts of soap before foaming –OR the ability of the water.
Chapter 19 - Neutralization
Determination of Water Hardness
Experiment 21 Determination of the hardness of water Purposes 1. To know the basic principle of complexometric titration. 2. Grasp the condition and the.
Hardness What’s in your pipes?. Hardness We experience “hardness” of water directly in several ways: 1. A “slimy” feel to our water when bathing. 2. Reduced.
Hardness CE Lab. Definition Hardness of water is a measure of its capacity to precipitate soap and is caused mainly by the presence of divalent.
WATER SOFTENING & ION EXCHANGE—ZEOLITE PROCESS
E NVIRONMENTAL E NGINEERING 441 Lecture 5: Water Treatment (2) Coagulation and flocculation Philadelphia University Faculty of Engineering Department of.
The Water By Dr. Rahul Shrivastava.
Applied Water and Spent water Manual Chapter 14
1 Solution Stoichiometry The concentration of a solution is the amount of solute present in a given quantity of solvent or solution. M = molarity = moles.
Unit 2 Stoichiometry – Volumetric analysis
 All salts are ionic compounds.  A salt is formed when a metallic ion or an ammonium ion (NH 4 + ) replaces one or more hydrogen ions of an acid. HClNaCl.
Acids, Alkalis and Indicators Prepared by Mdm RY Leow The Chinese High School.
Lipids.
Making Salts Soluble salt Insoluble salt Acid + excess insoluble solid
WATER The Universal Solvent Introduction.
Water and Solubility Write a definition for these words: Solute: Solvent: Solution: Atmospheric water vapour Run-off Transpiration Atmospheric water vapour.
Alkalinity, Hardness, & Lime/Soda Ash Softening
Hardness Objective n to understand the chemical basis of water hardness, how it originates, and ways it can affect water distribution systems. n to know.
Unit 9 Notes Acids, Bases, and Salts. Acids An acid is a substance that produces Hydrogen ion H + or hydronium H 3 O + in solution.
Water Treatment Sources of water
Acids and Bases. Solutions homogeneous mixtures in which one substance is dissolved into another the “solute” dissolves in the “solvent” example: Kool-Aid.
IV. Water Chemistry A. pH, hardness, and other ionic compounds and gases affecting water quality.
Water hardness & Special treatment. Water hardness & Special treatment.
Water Conditioning Process
Titration Titration is the quantitative measurement of an analyte (the substance whose quantity or concentration is to be determined) in solution by completely.
Water.
Chemical Synthesis Module C6. Chemical synthesis: chemical reactions and processes used to get a desired product using starting materials called reagents.
Phase Two Titration Year 10 EEI by Mr H Graham Volumetric analysis is; A type of chemical analysis which depends on the accurate measurement of solution.
Where does our drinking water come from? This means the water we drink has run through and across rocks.
iGCSE chemistry Section 4 lesson 1
Solvents and solutions. Pure water and impure water Pure water contains no other substances mixed with it (dissolved or not dissolved). Water from rivers,
CEE 160L – Introduction to Environmental Engineering and Science Lecture 9 Drinking Water.
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
Acid Reactions I Acids & Active Metals: Single replacement reactions Active metals (K, Na, Ca, Mg, Al, Zn, Fe, Sn) Produce H 2 Oxidation-reduction reactions.
Water and Humans go hand in hand!!!. Importance of Water to human life Next to oxygen, water is the most essential element to human life; the body usually.
Dr.Shuchita Agrawal BTIRT Sironja,Sagar(MP)
UNIT-IV WATER AND ITS TREATMENT
Water & it’s Industrial Applications Dr. Shuchita Agrawal BTIRT Sironja, Saga r 1.
C3 Review PowerPoint Presentation.  Qualitative Analysis is where you find out what type of substance you have present.  Quantitative Analysis is when.
Associate Professor (H & S)
Hardness What’s in your pipes?.
Chemical Changes and Structure
Special Oxygenized Drinking Water
Acids and Alkalis Grade 10.
UNIT-IV WATER AND ITS TREATMENT
Chemistry 3 Key Ideas.
Determination of Water Hardness
1 Salts V2.0 Unit 11 (Pg 138).
MULTIPLE CHOICE QUESTIONS
Acid and Bases. pH.
Internal Treatment: 3) Carbonate Conditioning :
ENGINEERING CHEMISTRY – II
Introduction What is the goal of Water Treatment Technologies?
Softening of Water : Softening can be done in two ways
Water and its treatment (3)
Analysis of antacid By titration
Water Impurities and Purification
WATER TECHNOLOGY Course: B.Tech Subject: Engineering Chemistry Unit:4
Water Hardness.
What is the function of Antacids ? These are drugs which are usually alkaline substances Used for neutralizing excess acid in the stomach Helps patients.
Lipids-I.
EXP. NO. 6 Acid Base Titration
SOFTENING METHOD OF WATER
Presentation transcript:

WATER  Water is most abundant, useful & misused one  It is universal solvent Uses :  Domestic purposes : Cooking, bathing, Drinking  Industries : Boilers, Dye industries, cotton. Sources : 1. Surface water 2. Underground water

1.Surface water : 1. Rain Water 2. River Water 3. Lake Water 4. Sea Water  It is most impure form  Continuous evaporation increases concentration of impurities.  Dissolved salts = 3.5 %  NaCl = 2.6 %

2. Under Ground Water :  Part of rain water,  Reaches the earth, percolates into the earth.  It comes in constant with a no of minerals

HARDNESS OF WATER Characteristic of water which prevents lathering of soap Due to the presence of salts of Ca, Mg & other heavy metals. Hard water does not produce lather, from white scum or precipitate Precipitate forms due to the formation insoluble soaps (Calcium stearate & magnesium stearate)

Types : 1. Temporary (carbonate) Hardness 2. Permanent ( Non carbonate ) Hardness 1.Temporary Hardness : (Carbonate) Caused due to the presence of dissolved bicarbonates of Ca, Mg, Na, K. Destroyed by boiling.

2.Permanent hardness (Non Carbonate) : Caused due to the presence of Chloride, Sulphates, Nitrates of Ca, Mg, and other metals. Can’t be removed by boiling. Calcium Carbonate Equivalence :  Hardness is expressed in calcium carbonate equivalence.  M.Wt. of CaCO 3 = 100  Most insoluble

Units : 1 ppm = 1 part of CaCO 3 present in 10 6 parts of water 1 mg/lit. = 1 mg of CaCO 3 present in 1L of water 1 0 Cl = 1 part of CaCO 3 present in70,000 L of water (1 Gallon) 1 0 Fr = 1 part of CaCO 3 present in 10 5 parts of water

EDTA method : (Complexometric method) EDTA = Elthylene diamine tetra acetic acid It exists as its di sodium salt  Soap titration method  EDTA method Estimation of Hardness

Principle : EEquivalent point (end point ) is determined by eriochrome black –T indicator (alcoholic solution of blue dye.)  Indicator is effective at pH 10 BBuffer used is (NH 4 OH – NH 4 Cl) to maintain pH Colour change wine-red to blue

PROCEDURE: Part: 1: Preparation of Standard Hard water: Transfer a known mass (about 10 mg) of calcium carbonate into a 100ml volumetric flask. Add ml(approximately) of water. Add dilute hydrochloric acid till a clear solution is obtained. Make up the volume to the mark by adding water.

Part:2: Standardization of EDTA: Pipette out 10ml of Standard hard water, into a conical flask. Add 5ml (approx) of buffer and a few drops of Eriochrome black-T indicator. The solution attains wine-red colour. Titrate the contents of the conical flask against the solution of EDTA solution. Stop the addition of solution from the burette when the colour of solution in the conical flask changes from wine-red to blue. Note the burette reading and repeat the titration to get concurrent results. Let the volume of the solution of EDTA consumed in this titration be ‘V1’ ml.

Part:3: Determination of Total Hardness of Test Sample of Water: Pipette out 10ml of test sample of water in the conical flask. Add 5ml (approx) of buffer and 3 to 4 drops of Eriochrome black-T indicator. The solution attains wine-red colour. Titrate the contents of the conical flask against EDTA solution till the colour changes from wine-red to blue. Note the burette reading and repeat the titration to get concurrent results. Let the volume of EDTA solution consumed in this titration be ‘V2’ ml. The total hardness of the test sample of water is calculated as follows:

Calculations: 1) 100ml of standard hard water = x mg of calcium carbonate 1 ml of standard hard water = x/100 mg of calcium carbonate 2) V1ml of EDTA solution = 10 ml of standard hard water 1 ml of EDTA solution = 10/V1 ml of standard hard water = (10/V1)((x/100)mg of calcium carbonate = (x/10V1) mg of calcium carbonate 3) 10 ml of test sample water =V2 ml of EDTA 1000 ml of test sample of water = 100 V2 ml of EDTA = 100 V2 (x/10V1) mg of Calcium carbonate = (10 V2 x /V1) mg of Calcium carbonate Total Hardness of test sample of water = (10 V2 x/ V1) mg/litre

ANALYSIS OF WATER ALKALINITY: Presence of anions, such as carbonates, bicarbonates and hydroxide results in alkalinity of water. The estimation of water is done through the titrating water sample against standard acid using Phenolphthalein and methyl orange indicator. Two indicators are used as the different anions to give end points at different PH values.

Out of three anions CO 3 -2, HCO 3 -2 & OH - out of the three anions any two of them can exist in water together( CO 3 -2, OH - ), (HCO 3 -2, CO 3 -2 ) HCO 3 -2 & OH- can’t be present together because H + ion of HCO - 3 netutralises OH -. HCO 3 – + OH – CO H 2 O

Experimental procedure Hundred milliliter of water sample is taken and two drops of phenolphthalein is added to it. The colour will become pink due to the PH value above 10.This sample of water is titrated with N/50 HCl solution. At the end pink colour disappears this end point termed as P- end point. Now add two drops of methyl orange indicator to the same water (PH>7). At the end point, pink colour disappears this end point known as M- end point /Methyl orange end point.

Reactions CO H +  HCO 3 - HCO H +  H CO 2 OH - + H +  H 2 O Calculations: The phenolphthalein alkalinity in terms of CaCO3 = P*50*10 6 /50*100*1000=(10P)PPM The alkalinity of methyl orange =M*50*10 6 /50*100*1000=(10M)PPM

Result of Alkalinity P = 0 P < ½T P=½T P>½T P = T OH – alkalinity 0 2P-T P=T Carbonate Alkalinity 0 2P 2(T-P) 0 Bicarbonate Alkalinity T T-2P 0

Softening of water  It can be done by 2 methods 1) internal treatment. 2) external treatment.

 Water used for industrial purposes sufficiently pure.  The process of removing hardness producing substances from water is called softening of water. 1. Lime-Soda process:  In this method soluble Ca & Mg salts in water are converted in to insoluble compounds, by adding calculated amount of Lime and soda.  CaCO3 and Mg(OH)2, so precipitated, are filtered off. EXTERNAL TREATMENT (SOFTENING METHODS)

Cold lime soda process: In this process calculated amount of chemicals (lime and soda) are mixed with water at RT At RT the precipitates formed are finely divided, will not be settle down easily. So, it is essential to add small amount of coagulants (Alum, Sodium aluminate, Aluminium sulphate). These coagulants help in the fine precipitation. Sodium aluminate also helps the removal of silica and oil. This cold L-S process provides water-containing 50-60ppm.

NaAlO 2 + H 2 O  NaOH + Al(OH) 3  Al 2 (SO4) ­3 +Ca(HCO3) 2  Al(OH) 3 + CaSO 4 + CO 2  HOT LIME SODA PROSESS: It involves treating water with softening chemicals at a temperature of oC The reactions proceed faster Softening capacity increased Precipitates and sludge formed settle down rapidly No coagulants are needed Much of the dissolved gases driven out of the water Filtration of softened water is fast

Advantages of Lime Soda process: Very economical. Lesser amount of coagulants is needed. This process increases the pH of water and protects from corrosion. Mineral quantity is reduced. Disadvantages of Lime Soda process:  Careful operation and skilled supervision is required.  Disposal of large amount of sludge is difficult.  Removes hardness up to 15ppm.

2. ZEOLITE (PERMUTIT) PROCESS:  Zeolite is hydrated sodium alumino silicate.  It is also called as Permutits.  It capable of exchanging its sodium ions  Structure of sodium Zeolite is  Na 2 O.Al 2 O 3.xSiO 2.yH 2 O.  Where x = 2-10, y = 2-6

Zeolites are two types 1.Natural Zeolites: These are non-porous. Ex.: Na 2 O.Al 2 O 3.4SiO 2.2H 2 O 2.Synthetic Zeolites: These are porous and possess gel structure.  These have higher exchange capacity  Prepared by heating together china clay, faldspar and soda.

Process: Na 2 Ze + Ca(HCO 3 ) 2  NaHCO 3 + CaZe Regeneration: After some time the zeolite is converted in to Ca and Mg Zeolites and it gets exhausted. At this stage the supply of this hard water is stopped and the exhausted Zeolite is reclaimed by treating with 10% NaCl CaZe + 2 NaCl  CaCl 2 + Na 2 Ze Limitations: If the water is turbid, the suspended matter is to be removed. Large quantity of iron and manganese should be removed; otherwise they form Mn and Fe Zeolites. if mineral acids are present, they may destroy the Zeolite bed.

Advantages: It removes the hardness up to 10ppm. The equipment used is very compact. No impurities are precipitated, so there is no formation of sludge or scale. It requires less time. It requires less skill. Disadvantages:  Treated water contains more sodium.  It removes only positive ions.  High turbidity water cannot be treated.

3.Ion Exchange Process: It is also called de-ionization or demineralisation. Ion exchange resins are in soluble, long chain, cross-linked polymers with a micro porous structure. Resins containing acid groups (COOH, SO 3 H) are capable of exchanging their H+ ions with other cations. Resins containing basic groups (OH -, NH 2 - ) are capable of exchanging their OH- ions with other anions. Cation exchange resin Anion exchange resin

For efficient separation ions-selective membranes are employed. Ex. RCOO -, RSO 3 - and R 4 N + Cl -

Examples of resins:

Ion exchange process: The hard water is passes first through cation exchange column, which removes all the cations like Ca+2,Mg+2 etc. from it, and equivalent amount of H+ ions are released from this column to water thus: 2RH + + Ca +2  R2Ca H + 2RH + + Mg +2  R2Mg H + After cation exchange column, the hard water is passed through anion exchange column, which removes all the anions like SO 4 -2, Cl-etc. present in the water and equivalent amount of OH- ions are released from this column thus : ROH - + Cl -  RCl - 2ROH - + SO 4 -2  2OH -

H + & OH - ions get combined to produced water molecule. H + +OH -  H 2 O Thus water coming from the exchanger is free from cations as well as anions. Regeneration : Exhausted anion resin is regenerated by dil. HCl, anion by dil.NaOH.

Internal treatment Internal treatment of boiler water is carried out by adding proper chemicals to precipitate the scale forming impurities in the form of sludge and to convert the scale forming chemicals into sludges which can be removed by blow down process. In other method problem causing cations converted in to compounds, which will stay in dissolved form in water and thus do not cause any harm. Some of the internal treatment methods used for the removed of scale formation in boilers are.

Colloidal conditioning: Scale formation can be avoided in low pressure boilers by adding substances like kerosene, tannin, agar-agar etc. which get absorbed over the scale forming precipices, there by yielding non-sticky and lose deposits which can be easily removed by blow down process.

Carbonate conditioning In low pressure boilers, scale formation can be avoided by adding sodiunm carbonate to boiler water, when salts like CaSO4 can be converted into CaCO3 in equilibrium. CaSO 4 + Na 2 CO 3  CaCO 3 + Na 2 SO 4

Calgon conditioning: It involves in adding Sod. Hexameta phosphate (calgon) to boiler water to prevent the scale and sludge formation. Calgon converts the scale forming impurity like CaSO4 into soluble complex compound. Na 2 (Na 4 (PO 3 ) 6 )  2Na+ + (Na 4 (PO 3 ) 6 ) -2 2CaSO 4 + (Na 4 (PO 3 )) -2  (Ca 2 (PO 3 ) 6 ) Na 2 SO 4 solublecomplex

Phosphate conditioning It is applicable to high pressure boilers scale formation is avoided by adding sod.phospate, which reacts with Mg,Ca salts forming non-adherent and easily removed by blow down process. 3MCl 2 + 2Na 3 PO 4  M 3 (PO 4 ) 2 + 6NaCl 3MSO Na 3 PO 4  M 3 (PO 4 ) + 6NaSO 4 Where M= Ca +2 or Mg +2 The main phosphates employed are Sod.dihydrogen phosphate, disodium hydrogen phosphate, trisodium phosphate.

Treatment with Sodium Aluminates: It gets hydrolyzed yielding NaOH & gelatinous ppt. of aluminum hydroxide. Thus: NaAlO 2 + 2H 2 O  NaOH +Al(OH) 3 The NaOH, so formed, ppts some of the Mg as Mg(OH) 2 MgCl 2 + 2NaOH  Mg(OH) 2 + 2NaCl. The ppts are removed by blow down process.