Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring.

Slides:



Advertisements
Similar presentations
Making Procedures Safe(r) Central Line Insertion Paul Currier, MD, MPH MGH Pulmonary & Critical Care Unit Associate Program Director for Procedures and.
Advertisements

Central venous catheters
Haemodynamic Monitoring
Bringing Solutions to Vascular Medicine ML2303 Rev A 10/10.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Dr. Abdul-Monim Batiha Monitoring in Critical Care Dr. Abdul-Monim Batiha.
Eisenmenger Syndrome Seoul National University Hospital Department of Thoracic & Cardiovascular Surgery.
Hemodynamic monitoring
Intra-aortic Balloon Pump (IABP)
Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring.
SHOCK.
Haemodynamic Monitoring
CENTRAL VENOUS PRESSURE LEARNING OUTCOMES By the end of this session the student should be able to : Explain the indications for a patient requiring.
Cardiogenic Shock and Hemodynamics. Outline Overview of shock – Hemodynamic Parameters – PA catheter, complications – Differentiating Types of Shock Cardiogenic.
Blood Flow Measurement:The Cardiac Output and Vascular Resistance Grossman’s cardiac catheterization, angiography, and intervention CV R5 許志新醫師 Supervisor:
Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring.
Chapter 15 Assessment of Cardiac Output
Hemodynamic monitoring Prof. Jean-Louis TEBOUL University Paris-South
CENTRAL LINES AND ARTERIAL LINES
Cardiovascular System Assessments
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
Angiography Excessive Commercialisation Complications of Angiography 1.Death 2.Myocardial Infarction Factors predisposing Unstable angina Angina at rest.
Circulatory Failure 6 th November Physiology and pathophysiology of the heart and circulation Pathophysiological effects of altered intravascular.
Monitoring of Patients during Anesthesia and Surgery Haim Berkenstadt MD Director, Department of Anesthesiology Deputy Director, The Israel Center for.
Wet, Dry, or Even? Some Ways of Looking at Volume Status without a Pulmonary-Arterial Catheter Anne K. Sutherland, MD Critical Care Medicine St. Barnabas.
Richard Beale Guy’s and St Thomas’ Hospital Trust London, UK
Cardiac Output Monitoring in Cardiac Surgery with Cardiopulmonary Bypass K. Lebedinski, A. Vetchinkin St. Petersburg.
Haemodynamic Monitoring
Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimizing the Cardiac Output D.Measuring.
Arterial Blood Gases ABG. DEFINATION  An arterial blood gas (ABG) is a blood test that is performed taking blood from an artery, rather than a vein.
Cardio Investigations. Patients presenting with chest pain may be identified as having definite or possible angina from their history alone. Risk Factor.
SHOCK BASIC TRAUMA COURSE SHOCK IS A CONDITION WHICH RESULTS FROM INADEQUATE ORGAN PERFUSION AND TISSUE OXYGENATION.
Chapter 16 Assessment of Hemodynamic Pressures
Use the right tool for the right job!
Are The Less Invasive Techniques For Monitoring Cardiac Output As Accurate As The Pulmonary Artery Catheter? Dr Andrew Rhodes St George’s Hospital London.
Shock. Outlines Definitions Signs and symptoms of shock Classification General principles of management Specific types of shock.
Cardiac Output Monitoring
Cardiac Cath and Angiocardiography Adult II FINAL 2/2015.
Differentiate Pulmonary arterial hypertension from pulmonary venous congestion.
Intra-Aortic Balloon Pump What it is and what it does
CVS Monitoring in Shock
Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring.
Arterial Line. Outline Definition. Indication Contraindication. EQUIPMENT Arterial Sites Nursing Skills Standard.
Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring.
PulseCO Monitoring System. Estimates of Preload Clinical: BP, HR, capillary refill, urine Postural changes CVP PAC Echo.
Prof.Mehdi H MUMTAZ FLUID THERAPY ;It is the first weapon in the armoury of physcian to counter hypovolaemia or shock; ;Uncorrected hypovolaemia with.
Intravenous cannulation
Hemodynamic Monitoring John Nation RN, MSN Thanks to Nancy Jenkins.
Arterial Blood Pressure(ABP) Arterial Blood Pressure(ABP) Central Venous Pressure(CVP) Central Venous Pressure(CVP) Pulmonary Artery Pressure(PAP) Pulmonary.
Shock and its treatment Jozsef Stankovics Department of Paediatrics, Medical University of Pécs 2008.
Monitoring in Anesthesia Dr.Arkan Jaafar, M.D. Anesthesiologist,Medical college of Mosul.
Cerebral Angiography Radiological study of the blood vessels of the brain to enable physicians to localized and diagnose pathology or anomalies of the.
FloTrac Sensor & Vigileo Monitor
Plasma and plasma components in the management of disseminated intravascular coagulation Marcel Levi* Academic Medical Center, University of Amsterdam,
Assessment of the Cardiovascular System. The Cardiovascular System  Anatomy and physiology  Heart—its structure and function  Valves, arteries  Cardiac.
Case 7- Complication of central line insertion
Nasim Naderi M.D. Cardiologist June 2011
Physiologic signals Lecture 5.
Objectives Describe the cardiovascular monitoring techniques used in the care of critically ill patients and how to interpret the results of hemodynamic.
Copyright © 2018 American Academy of Pediatrics.
Cardiac Cath NUR 422.
高風險手術患者麻醉中的血液動力學分析 Hemodynamic optimization for high risk surgical patients 三軍總醫院麻醉部 呂忠和醫師.
Polmunary edema.
Mechanical Circulatory Support Devices HOSEIN PASANDI.
Transpulmonary indicator dilution method
Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation 
Heart–lung interactions with different ventilatory settings during acute lung injury and hypovolaemia: an experimental study  F.J. da Silva Ramos, E.M.
Circulation (cardiovascular) monitoring
INVASIVE PRESSURE MONITORING
Presentation transcript:

Haemodynamic Monitoring Theory and Practice

2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring Preload E.Introduction to PiCCO Technology F.Practical Approach G.Fields of Application H.Limitations

Knowledge of the limitations is essential for correct interpretation of the data! Limitations of the PiCCO parameters - thermodilution Limitations GEDV - data will give false-high with large aortic aneurysm - is not usable with intracardiac left-right shunt - can be overestimated in severe valvular insufficiency EVLW - data will be falsely high with gross pulmonary perfusion failure (macro-embolism) - is not usable with intracardiac left-right shunt

can only be used with fully controlled mechanical ventilation (minimal tidal volume 6-8ml/kg) and absence of cardiac arrhythmias (otherwise may give false high reading) Knowledge of the limitations is essential for correct interpretation of the data! Limitations of PiCCO parameters – pulse contour analysis Limitations SVV / PPV not valid when an IABP is in use (thermodilution is unaffected) All parameters of pulse contour analysis

PiCCO Technology in special situations Special clinical situations normally no interference with the PiCCO parametersRenal replacement therapy Prone positioning all parameters are measured correctly Peripheral venous injection not recommended, measurements possibly incorrect

Limitations of application of PiCCO Technology Limitations Because of the use of normal saline as indicator, PiCCO measurements are possible at virtually any desired frequency, even in children (over 5kg) and pregnant women. PiCCO Technology has no specific limitations of application

Contraindications to PiCCO Technology Limitations The usual precautions are required when puncturing larger blood vessels: coagulation disorders vascular prosthesis (use other puncture site, e.g. axillary) Because of the low invasiveness there are no absolute contraindications

The complications of PiCCO technology are confined to the usual risks of arterial puncture Complications of PiCCO Technology Limitations injuries associated with the puncture infection perfusion disturbances PULSION recommends that the PiCCO catheter be removed after 10 days at the latest

None the less …..