Cavity status; recent KEK activities 2012.05.08: Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: 33.5 -> 18.4MV/m.

Slides:



Advertisements
Similar presentations
6/Nov/2012 TTC Meeting 1 Improvement of cavity performance by T-mapping/X-ray-mapping, optical inspection and local grinding Kirk.
Advertisements

KEK cavity status, March 2011 H. Hayano, ALCPG11, WG3, Eugene.
Stain appeared after EP acid renewal Field emission at low gradient happened on MHI-06, MHI-07, in VT. Kyoto-camera found brown stain trace in beam pipes,
Recent Surface Studies in KEK-STF
Cavity-Coupler Treatment & Testing Preparation of crab cavities for KEKB RF aging of input couplers. 17 th September 2009, LHC-CC09 at CERN K.Nakanishi.
Latest Design of ILC ( RDR). 1.3 GHz technology developed by TESLA Collaboration, R&D from 1992 to reduce the cost per MeV by a factor of 20 from current.
Cavity package T.Saeki BCD meeting 20 Dec Cavity shape BCD: TESLA shape Pros: small wakefield, HOM thoroughly investigated single-cell: 43 MV/m.
New HOM coupler design Demountable Damped Cavity (DDC) Sokendai, The graduated university for advanced studies. KEK, LL / Ichiro Cavity Group October 21,
1.3 GHz SRF Cavity R&D Plan Jiyuan Zhai ILC Group, IHEP 3 rd IHEP-KEK 1.3 GHz SRF Meeting, 7 Dec 2010, Beijing.
ESS cavities interfaces
Jim Kerby, Fermilab for Rongli Geng and the S0 Cavity Team 23 May 2010 Current Status of SCRF Cavity Development SCRF Cavity Technology and Industrialization.
Status of crab crossing studies Presented by NAKANISHI Kota (KEK) 2008/1/25.
Mechanical Issues SPL cavities/cryomodules Workshop CERN 30 Sep. 2009
Status of cavity fabrication facility at KEK H. Hayano, KEK Cavity Industrialization Study at KEK Superconducting RF Cavity Technology and Industrialization.
Detail discussion of S1 Global at STF H. Hayano (KEK) GDE Mar 3-6, 2008.
STF EP, VT commissioning by FNAL AES001 H. Hayano, KEK
Superconducting rf test facility STF 1 Optical Inspection update at KEK Ken Watanabe ( KEK ) ILWS08 in Chicago 17-Nov-08.
Field emission issue and strategy to improve H. Hayano.
S.Noguchi (KEK) ILC08 Chicago , Nov . 17, Cavity Package Test in STF STF Phase-1 E. Kako, S. Noguchi, H. Hayano, T. Shishido, M. Sato, K. Watanabe,
1 E. KAKO (KEK) 2012' May 28 Clermont 1 A_RD_03 R/D for the High Power Couplers for ILC Walid KAABI (LAL-Orsay, France) Eiji KAKO (KEK, Japan)
Parallel session summary ML/SCRF L. Lilje, H. Hayano, N. Ohuchi, S. Fukuda, C. Adolphsen (with help of Chris Nantista) TILC09,
Global Design Effort 1 S0 Status High-Gradient cavities Lutz Lilje DESY supplement by H. Hayano 04Sep2008 EC
Cavity status; recent KEK activities : Hayano (1)STF CM-1 cavities are; MHI MV/m for CM-1 ILC cryomodule (3-rd VT) MHI MV/m for.
Sample tests for stain problem at KEK LCWA2009 at Albuquerque 01 Oct T. Saeki 1.
CERN status - Nb cavity – Manufacturing 1 15/Nevember/2010, Ofelia Capatina EN/MME 1 SPL Cavity Working Group Meeting TaskExternal Company CERN Provide.
1.3GHz Input Coupler for ILC
Americas Cavity Specification C.M. Ginsburg (Fermilab) On behalf of the Fermilab cavity crew October 20, 2010.
CRAB for HL-LHC KEK activity 2010DEC Yoshiyuki MORITA.
Superconducting rf test facility LCWS 2010 in Beijing, 28 Mar 2010, Ken Watanabe Replica-method and local grinding repair K. Watanabe (KEK) LCWS 2010 in.
(1)[12~13/Dec/2009] Optical inspection (2)[14/Dec] frequency & field flatness measurement (3)[10/Mar/2010] pre-EP (5μm) (4)[11/Mar] EP1 (100μm) (5)[11/Mar]
E. KAKO (KEK) 2009' Oct. 26 ILC KEK Global Design Effort 1 Cavity Preparation for S1-Global Eiji Kako (KEK, Japan)
Update on S0 Work in the Americas Region Mark Champion 17 June 2008.
KEK-STF Vertical Test and Diagnostics Brief History & Future Plan Vertical Test Facility Cavity Diagnostic System Example of MHI#7 Cavity Summary of T-mapping.
IHEP GHz 9-cell Cavity R&D Status and Plan The Third IHEP-KEK 1.3GHz SC Technology Collaboration Meeting Dec. 7-8, 2010, IHEP, Beijing GAO Jie,
ALCPG2011, 3/19- 23, SRF Group Institute of Heavy Ion Physics, Peking University ALCPG /3/19-23, Eugene, Oregon, USA RF superconducting Cavity.
Cavity status; recent KEK activities MHI-06, MHI-7, MHI-8 were vertical tested on June, July.  EP acid (1000l) was re-newed on May 15. These cavity was.
Recent Results of Vertical Test for S1-Global Project at KEK-STF Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, H. Sakai, M. Satoh, T. Shishido, K. Umemori,
MHI#16 号機の2回目の EP2  Process log  Status of working  Monitor data during EP & Rinsing process  Comparison of EP2 Period : 2011/5/10 ~ 5/16 Process :
Summary of Results and Development of Online Monitor for T-mapping/X-ray-mapping in KEK-STF Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, M. Satoh, T. Shishido,
Standard EP recipe at KEK T. Saeki KEK Hot topics session SRF – 29 July 2011, Chicago.
Preparation procedure and RF processining of cERL-ML power coupler at KEK Hiroshi Sakai, Takaaki Furuya, Masato Sato, Kenji Shinoe, Kensei Umemori, Kazuhiro.
MHI#19 号機の1回目の EP2  Process log  Condition of EP2 & Rinsing process  Status of working  Monitor data during EP & Rinsing process Period : 2012/2/17~
Update on S0 Work in the Americas Region Camille Ginsburg (FNAL) 2 June 2009 Slides/Info from: Zack Conway (Cornell) Rongli Geng (JLab) Genfa Wu, Dmitri.
Americas Report C.M. Ginsburg (FNAL) for the FNAL/ANL, JLab, and Cornell (no report this time) cavity teams S0 Meeting 7.June 2011.
Developments of new treatment techniques for SRF cavities at KEK HORIZONTAL HPR FOR PERFORMANCE RECOVERY Yoshiyuki MORITA Motivation of developing HHPR.
Industrialization Studies in the KEK Cavity Fabrication Facility (CFF) H. Hayano The 2nd workshop on SCRF Cavity Technology and Industrialization.
Page 1 Jean Delayen Subashini De Silva Center for Accelerator Science Department of Physics, Old Dominion University and Thomas Jefferson National Accelerator.
Shuichi NoguchiTTC Meeting at Milano, Injector Cryomodule for cERL at KEK Cavity 2 Prototypes were tested. Input Coupler 2 Couplers were tested.
Eiji Kako (KEK, Japan)TTC at Cornell, 2013 June 13 1 HOM absorbers; KEK HOM couplers in injector Eiji Kako (KEK, Japan)
Guillaume Olry on behalf the IPN Orsay SPIRAL2 team TTC Meeting – Milan, 28 Feb-3 March 2011.
Summary of STF-EP facility at KEK.
ILC10 Beijing Global Design Effort
Condition of electron beam welding toward a high gradient application
ILC-SCRF Test Facilities considerations
Inspection of STF Baseline cavity #5 and #6
FNAL recent coupler troubles
for the FNAL/ANL, JLab, and Cornell cavity teams
S0 Status report from KEK
SPS – RFD Experience and Evolution to LHC
S1-G Webex meeting Global Design Effort
Recent results of Vertical-EP at KEK-Marui
Cost reduction activities in cavity fabrication at MHI
Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, M. Sato, T. Shishido, K
Recent VT Results in the STF-2 cavities
Quality control study with single-cell cavities
Vertical Test System and T-mapping/X-ray-mapping at KEK-STF
KEK injector cryomodule
Cavity Degradation Experience at S1-Global
Cavity & Cavity Integration; recent KEK activities
Cryomodule Design for CW Operation 3.9 GHz considerations
Presentation transcript:

Cavity status; recent KEK activities : Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: > 18.4MV/m F.E. turn ON MHI-016: 2-nd VT:34MV/m (finished) MHI-017: 1-st VT: 38MV/m (finished) MHI-018: 1-st VT: 31MV/m MHI-019: 1-st VT: 26MV/m MHI-020: 1-st VT: 9MV/m heavy field-emission MHI-021: 1-st VT: 38.9MV/m (finished) MHI-022: waiting for 1-st VT in this week (2) New bender/KEK cavities; TOS-02(w/o HOM): 1-st VT: 31.2MV/m HIT-02(with HOM): 1-st VT: 35.2MV/m KEK-00(w/o HOM): 1-st VT: 26MV/m, 2-nd VT:29MV/m KEK-01(with HOM): under fabrication (3) other project cavities; ERL-2cell cavity #2: 5-th VT: 50.4MV/m

ERL 2-cell cavity #2 5-th VT Detail report in the end of slides March 6

MHI st VT heavy field emission  input RF cable break happened! March 15

KEK-00(w/o HOM) 1-st VT March 29 limited by input RF cable break-down (at N-type J-J juction)

KEK-00(w/o HOM) 2-nd VT April 5 limited by cell#2 defects, other cells were over 40MV/m

MHI st VT April 12

HIT-02(with HOM) 1-st VT April 26 It has many defects on several Iris and beam pipe, however, it went up 35MV/m.

8 History and Recent result of cERL 2-cell cavity #2 K. Watanabe (KEK) May/2012

9 Log Mar/2009: Fabrication cavity by MHI July/2009: Bulk EP ( um) and Annealing Feb/2010: Light EP (20 um) and 1 st VT April/2010: Light EP (20 um) and 2 nd VT with HOM pick-up (Type 0 Normal) July/2010: Light EP (20 um) Aug/2010: 3 rd VT with HOM pick-up (Type 0 Normal) Sep/2010: Light EP (20 um) Oct/2010: 4 th VT with HOM pick-up (Type 0 Normal) Feb/2012: Light EP (5um) Mar/2012: 5 th VT with HOM pick-up (Type 2) 1 st VT: to check the cavity performance (quality check). 2 nd ~ 5 th VT: to study a performance of HOM coupler and HOM pick-ups. Measurement of sustainable field without quench at HOM coupler at CW The field was raised to a rf power limit or heating limit of HOM pick-ups. cERL injector 2-cell cavity #2 (Proto-type model) (With two input coupler port and five loop-type HOM couplers) Target Gradient is 15 MV/m at CW in Cryomodule. * Cavity design by E. Kako * HOM coupler and feed-through design by K. Watanabe * Optical Inspection was done after each treatment. Few defects found at Outside weld area. These defects created by press work. On the weld area, there are no welding defect. * The LLRF measurement, HOM study, RF tuning, optical inspection, preparation part, assembly work and VT were done by K. Watanabe with few Technicians. total EP removal =190µm

10 Example: Optical Inspection result (After 1 st VT) Four pit type defect found at Outside weld area. (defects created by press work) On the EBW seam, there were no welding defect.

11 Relation of defect size and heating detected by thermo-sensors No heating at 50 MV/m

12 Recent result of Vertical tests of #2 cavity: Qo-Eacc

13 cERL 2-cell (KEK) 9-cell TESLA-like Frequency1300 MHz R/Q G Esp/Eacc Hsp/Eacc [Oe/MV/m] K (coupling) L (effec.)0.23 m/cavity--- Iris diameter. BP diameter. 70 mm 88 mm 70 mm 80 mm OtherHsp on Equator 50 MV/m→2110 Oe Hsp on Equator 45 MV/m→1845 Oe Cavity Parameters of 2-cell injector and 9-cell cavity Calculated by E. Kako (by Superfish)

14 Max Eacc and Cause of limitationOther 1 st VT Mar/ MV/m without Quench. The test was stopped because a field exceeded 40MV/m. Removed material = 125 um 2 nd VT April/2010 Vacuum leak happened during 2K high field measurement, then the test was stopped. No quench at 14 MV/m in Liq He………. Leak location was one ICT 70 flange (Low temperature side). Removed material = 145 um With HOM pick-up (Type 0 Normal, gap = 0.5 mm) 3rd VT Aug/ MV/m with Quench at HOM pick-up. Sustainable field : 12 MV/m outside liq. He 17.4 MV/m in liq. He Cause of limitation was a heating of HOM pick-up. Removed material = 165 um With HOM pick-up (Type 0 Normal, gap = 0.5 mm) 4 th VT Oct/ MV/m with Quench at HOM pick-up. Sustainable field : 13 MV/m outside liq. He 18.4 MV/m in liq. He Cause of limitation was a heating of HOM pick-up. Removed material = 185 um With HOM pick-up (Type 0 Normal, gap = 2.0 mm) 5th VT Mar/ MV/m without Quench and Field Emission (in lig. He). The test was stopped because a field exceeded 50MV/m. (RF power limit) Hsp on Equator is 2127 Oe. Removed material = 190 um With HOM pick-up (Type 2, gap = 2.0 mm) Result of Vertical tests of #2 cavity: History and Summary

15 Surface treatment No.Amount EP [um] Current density 1st water rinsing rinseHPR [hour]Other Bulk EP Idle: 5 min Case 1 none2--- Light EP 1 st mA/cm2 Idle: 20 min Case 2 FM-20 and HOT Bath with Ultra-sonic (1 hour + 1 hour) (with Flange) In coated Helicoflex 100 C Baking Light EP 2 nd mA/cm2 Idle: 20 min Case 2 FM-20 and HOT Bath with Ultra-sonic (1 hour + 1 hour) (with Flange) In coated Helicoflex 100 C Baking Light EP 3 rd mA/cm2 Idle: 20 min Case 2 FM-20 with Ultra-sonic (2 hours) (with Flange) In coated Helicoflex 100 C Baking Light EP 4 th mA/cm2 Idle: 20 min Case 2 FM-20 with Ultra-sonic (2 hours) (with Flange) In coated Helicoflex 100 C Baking Light EP 5 th mA/cm2 Idle: 30 min Case 3 End Group cleaning by Brush. FM-20 with Ultra-sonic (30 min) End Group cleaning again by Brush (with Flange) Sn coated Helicoflex 120 C Baking Process of 1st water rinsing * Case 1: Water supply flow (4 min) -> Pump off (2 min) : Repeat this cycle (total 40 min) * Case 2: Water supply flow (3 min) -> Pump off (1 min) : Repeat this cycle (total 90 min) * Case 3: water fill-and-close (40 min), water supply flow 20min, and with cavity rotation 40min : total 100min

16 Preparation of HOM pick-up (1): Surface Treatment and Cleaning Method No.TypeTreatmentCleaning Method after CP 1 st VTWithout 2 nd VTType 0Feedthrough: only FM-20 with Ultra-sonic Niobium antenna: Chemical polishing (without mechanical polish) FM-20 with Ultra-sonic ~ 10 min. 3 rd VTType 0Feedthrough: only FM-20 with Ultra-sonic Niobium antenna: Chemical polishing (without mechanical polish) FM-20 with Ultra-sonic ~ 10 min. 4 th VTType 0Feedthrough: only FM-20 with Ultra-sonic Niobium antenna: Chemical polishing (without mechanical polish) FM-20 with Ultra-sonic ~ 10 min. 5 th VTType 2Remove a brazing material near Joint point between inner conductor and niobium antenna. Mechanical polishing on niobium antenna after fabrication (mirror finish). Chemical polishing on niobium part (Total: 5 min). After CP, FM-20 with Ultra-sonic ~ 20 min. Washing by sponge with FM-20. Dry at Class 10.

17 Preparation of HOM pick-up (2): Structure of HOM pick-ups Type 0Type 2: Improvement of cooling performance and surface conditions Seal Nb antennaFeedthrough Surface on Nb antenna Tip “Turn off -> CP” Not Smooth at antenna tip In case of “Turn off -> Mechanical Polish -> CP” Get Smooth surface on antenna tip Male pin Images: After Mechanical Polish Go to CP process

18 About 5th VT of #2 cavity

19 Process level during 2K high field measurement (5 th VT) Pt (field) Pref

20 Frequency and Qext change during cooldown (5 th VT) Tuning of HOM couplers for accelerating mode was very well. Resonant Frequency at Room temp (vacuum). is MHz.

21 Lorentz force detuning (5 th VT)

22 Trend during 2K high field (5 th VT) A process happened at 50 MV/m, then X-ray level was degrease. (Final: 50 uSv/h at 50.4 MV/m) During 2K High field test, the RF power was supplied always on. Qext of HOM couplers were not changed (no quench observed at HOM pickups).

23 Reference of world record of Hsp on Equator