Zensol Automation Inc. ZENSOL First Trip Monitoring In addition to doing timing and motion on circuit breakers, our CBA-32P instruments are capable of.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Obtain 24/7 Powerful Asset and Connectivity Management Software for Enterprise Data Centers.
Tecom IP Receiver. Overview The Tecom IP Receiver is a server which provides a cost-effective and secure method to monitor Challenger panels over IP networks.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Lab7: Introduction to Arduino
NetSure™ RDB Series.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Aloha Observatory Design Cabled Observatory Presentation School of Ocean and Earth Science and Technology February 2006.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
Company LOGO. 2 DELTATEE INNOVATION What is Wireless Wire? What is Wireless Wire?  The Wireless Wire is able to achieve these benefits by using the Zigbee.
1 CSCI N305 C Language Programming Welcome to CSCI N305! Compiling Your First Program Using Microsoft Visual Studio 2008.
Tutorial – “How to:” 1) Change the resolution on your display 2) Setup Multiple Displays.
Circuit breaker testing – New Approach
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
1 Darrin Marr Marcie Webb Brad Zarikoff Digital Input Power Meter.
Technical Brief v1.0. Communication tools that broadcast visual content directly onto the screens of computers, using multiple channels and formats Easy.
Adventures in Electrical Engineering Or How I Spent My Summer Vacation Thomas Reed Poteet High School E 3 Summer Research Program At Texas A&M Adventures.
Single Door configuration/POE On-line Power and communication data is provided with one cable from the PoE switch. The Data and Power is split at the controller.
Given Connections Solution
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
1 PCA2 On-load Protection Condition Analyser. 2 PCA2 online testing concept Concept introduction: PCA2 is a new system test approach intended to save.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
myDAQ Biomedical Instrumentation Board
International Scientific & Technical Conference
Communication Networks and Systems In Substations
G650 Generator Protection & Control System
Diagnostic & Troubleshooting Date 06/09/00, Page 1 Diagnostic & Troubleshooting s.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Computer Literacy for IC 3 Unit 1: Computing Fundamentals © 2010 Pearson Education, Inc. | Publishing as Prentice Hall.1 Chapter 1: Identifying Types of.
Radian Research, Inc. Radian Research, Inc. an employee owned company Power and Energy Measurement Specialists 3852 Fortune Drive.
1 EL Consolidation IEFC Workshop F. Duval on behalf of EN/EL
Arduino. What is it? A open-source software suite and single-board microcontroller. Allows easy and affordable prototyping of microcontroller applications.
QuikTrac 5.5, a validated Motorola Software Solution, allows you to take your Host ERP screens and extend them out to fixed or mobile devices including.
AFELink Mail Ballot Partner Demo. What is AFELink? AFELink automates sending and receiving AFEs / Mail Ballots and responses between operators and partners.
Version Mars 12, 2002Zensol Automation Inc. TIMING TESTS - ALABAMA NEXTPREVIOUS BACK PAGE 1 b Perform timing tests on a 3 contact breaker Breaker preparation.
An Overview of LabVIEW by: The Software User-Interface Group!
SYSTEM DESIGN. USB DRIVE CLICK ON “START HERE.HTML” TO BEGIN CLICK ON LOGO TO ACCESS MANUFACTURER FILES CLICK ON WEB LINK TO ACCESS MANUFACTURER WEBSITE.
SmartMQn Motor Horner APG, LLC September 9, 2008.
ISA CIRCUIT BREAKERS TEST SETS
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
Analog addressable systems for hi end solutions. Thanks to LOOPMAP technology, which is the ultimate technology in loop addressing and fault finding,
TF Joint Operations Review Commissioning Plan C Neumeyer 2/10/05 Test Shots Instrumentation Benchmarking.
MAKE: AN ELECTRONICS WORKSHOP
Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Machine Condition Monitoring on ControlNet RSLogix5000 support for XM ®
Saahithi Chillara Radhika Goyal ECE Fall Senior Design Project.
Data Cabling Contractors in Houston
© ABB - Page 1 IEC proven technology and innovation IEC UCA 2.0 IEC Communication concepts Data Models Ethernet Technology Process.
1 ALARMLINC. 2 OVERVIEW Expanding Situational AwarenessOVERVIEW.
Overview Presentation MKT-DSRV-P- 001E. Product Overview Network based video transmission product with on-board digital recording Allows analogue fixed/PTZ.
This information is confidential and is not to be provided to any third party without Vicon Industries Inc.’s prior written consent. 1 Plug and Play NVR.
BC-5010 Wireless Outdoor Example. X.USB The BC-5010 features a powerful processor and USB 2.0 ports. It can support the AirLive X.USB which is a wireless.
Doble TDR 900 Test Set and T-Doble Software Set-up and Testing.
This information is confidential and is not to be provided to any third party without Vicon Industries Inc.’s prior written consent. 1 Plug and Play NVR.
Data Center Security Services & Solutions in Dubai
Aloha Observatory Design
804 Multimedia Test Instrument
Bandwidth Utilization
Banana Piano in 20 min Be a Maker, not just a User Start Coding!
Microsoft office setup tech support
Cable & Phase identification
Project Members: M.Premraj ( ) G.Rakesh ( ) J.Rameshwaran ( )
UPS Connectivity Options: PPDM ( )
Music by Touch Music by Touch Presentation > TeachEngineering.org
Protection Philosophy
Technician Operation Presentation
ورود اطلاعات بصورت غيربرخط
Downloading to the NXT requires the correct hardware setup
Presentation transcript:

Zensol Automation Inc. ZENSOL First Trip Monitoring In addition to doing timing and motion on circuit breakers, our CBA-32P instruments are capable of doing on-line first trip monitoring. Here is an example of a real test in Alabama. NEXTPREVIOUS BACK PAGE 1

Zensol Automation Inc. First Trip Monitoring b Real tests in Alabama (USA) NEXTPREVIOUS BACK PAGE 1 Control cabinet Goal: To show that the CBA- 32P is able to to do ON-LINE testing of breaker first trip.

Zensol Automation Inc. First Trip Monitoring  The challenge NEXTPREVIOUS BACK PAGE 1 No need to open the sectionnor to isolate the breaker When doing first trip monitoring, the breaker is always « on line », which means that the breaker is not isolated during the test. Connecting the contacts is impossible because the current circulating is too high (thousands of amps). Contrary to classic timing tests, the trip test must be done without the help of the CBA-32P contacts.

Zensol Automation Inc. First Trip Monitoring b The solution NEXTPREVIOUS BACK PAGE 1 The solution is to connect a current transducer directly on the output of the CTs. The principle is to measure the lowest current (5 amps) to know the evolution of the current and at the same time to guarantee the security of the operators.

Zensol Automation Inc. First Trip Monitoring b Test set-up NEXTPREVIOUS BACK PAGE Vcc analog inputs To do on-line testing, To monitor the breaker first trip, the current transducer will be connected to the analog inputs of the CBA-32P.

Zensol Automation Inc. First Trip Monitoring b The first trip monitoring kit : KIT–Z-FT NEXTPREVIOUS BACK PAGE 1 Current transducer Connected to one of the analog inputs of the CBA-32P Interface We use a current transducer working like a amperemetric clamp, but stronger.

Zensol Automation Inc. First Trip Monitoring b Installation of the current transducer NEXTPREVIOUS BACK PAGE 1 Current transducers Interface Extension to connect the transducer to the CBA-32P

Zensol Automation Inc. First Trip Monitoring b Easy test procedure NEXTPREVIOUS BACK PAGE 1 Ground the CBA-32P Ground the CBA-32P Connect the optic fiber link Connect the optic fiber link Connect the command cable and the current transducer onto the control cabinet Connect the command cable and the current transducer onto the control cabinet Connect the current transducer to the analog inputs of the CBA-32P Connect the current transducer to the analog inputs of the CBA-32P turn on the CBA-32P and the CBA WIN software turn on the CBA-32P and the CBA WIN software GroundPower Analog input Command cable Fiber optic

Zensol Automation Inc. First Trip Monitoring b Trip test NEXTPREVIOUS BACK PAGE 1 28,60 ms

Zensol Automation Inc. First Trip Monitoring In this example we only use 1 current transducer which measures 1 phase. You can measure the three phases simultaneously, in “one simple click of the mouse”, by connecting three current transducers. CBA-32P = On-line testing of breaker's first trip + Off-line testing (including timing & motion) All the tests are done according to the international standards IEC