Preparation of the Carbon Paste Electrode Modified with Ferrocene and Its Applications to Detection of Hydrogen Peroxide and Glucose Yi-Sheng Wang ( 汪乙生.

Slides:



Advertisements
Similar presentations
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Advertisements

Lecture 6a Cyclic Voltammetry.
Evans Diagrams.
Hydrogen Peroxide Detection Using Biogenic and Synthetic MnO 2 Shu Feng, Jim Nurmi, Paul Tratynek Satya Chinni, Brad Tebo Department of Environmental and.
New electrode materials for H 2 O 2 New electrode materials for H 2 O 2 based sensors and biosensors Francesco Ricci 1, Carla Gonçalves 2, Giuseppe Palleschi.
Abstract Sibley School of Mechanical and Aerospace Engineering, Cornell University Researchers from Cornell University and the Cornell Lab of Ornithology.
Fabrication of a Microelectrode Array Biosensor Based on a Modified Enzyme-Chitosan Biocomposite Lorenzo D’Amico October 1, 2008.
Enhanced Electrochemical Reduction of Hydrogen Peroxide at Surfactant/Salt Modified Electrodes Laura Gonzalez-Macia 1, Malcolm R. Smyth 2 and Anthony J.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Introduction Silver(I) Oxide-Graphene Oxide Sensor for Hydrogen Peroxide Austin Scherbarth, Professor Lia Stanciu, Alexandra Snyder, Isabella Ramirez School.
Determination of Partition Coefficient of NAD + on Nafion 117 membranes Importance: Partitioning process affects actual NAD + and NADH concentrations,
Application: A novel, non-destructive method which provides characterization of the three-phase interface in both catalyst and diffusion layers, between.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ferrocene Yi-Sheng Wang ( 汪乙生 ), Ting-Li Lin ( 林庭立 ), Hau Lin ( 林浩 ) Department.
Dynamics and Steady States of Two Chemostats in Series Due to the contamination of the biochemical waste, the techniques of waste treatment have been applied.
Ionic Liquids: A New Class of Sensing Materials Linlin Zhao Bioanalytical Chem, Spring 2007, UConn.
Reporter:Chen-Kun Lin Adviser: Cheng-Chien Wang
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Carbon Nanotubes as Biosensors ME 695 Yang 11/30/2004.
Department of Chemical Engineering University of South Carolina by Hansung Kim and Branko N. Popov Department of Chemical Engineering Center for Electrochemical.
Introducti on Objectiv e Experimenta l section Results and discussion Conclusio ns.
PREPARATION OF ZnO NANOWIRES BY ELECTROCHEMICAL DEPOSITION
Alkaline Methanol Fuel Cell Tam Duong Dr. Yushan Yan.
An Analysis of Dynamics of the Prey-Predator Interaction in a Chemostat Wen-Ke Su ( 蘇文柯 ), Chung-Min Lien ( 連崇閔 ), Hau Lin ( 林浩 ) Department of Chemical.
Nichole Squair and Robert J. LeSuer Department of Chemistry and Physics, Chicago State University, Chicago, IL We report on the use of Scanning Electrochemical.
A Study of the Effect of Operating Potential on Detection of Hydrogen Peroxide for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao.
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
Advisor : Ru-Li Lin Advisee :Shih-Min Chen Southern Taiwan University of Science and Technology, Department of Mechanical Engineering, Tainan, TAIWAN Date.
NOVEL NON-CONDUCTING FILMSFOR INTERFERENCE-FREE ELECTROCHEMICAL SENSORS M. BADEA a, A. CURULLI b*, G. PALLESCHI a, S. KACIULIS c, A. MEZZI c a Università.
Professor: Cheng-Ho Chen Student: Jing-Mei Wang Reporting date: 2015 / 05 / 06.
A Study of Statistical Analysis of the Main Effects and Interaction Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
The Optimum Operating Conditions for Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min.
An Analysis of the Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min Lien.
The Operating Potential on the Sensitivity of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財.
Microwave Assisted ZnO Nanorod Growth for Biosensing This material is based upon work supported by the National Science Foundation.
Steady States and Dynamic Behavior of a Chemostat Shan-Cheng Chyou ( 仇善誠 ), Chung-Min Lien ( 連崇閔 ), Hau Lin ( 林浩 ) Department of Chemical and Materials.
The Effect of Stirring Rate on the Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chih-Ying.
An Analysis of Variance of Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao ( 蕭佳政 ), Chih-Ying.
指導教授:王聖璋 博士 (Pro.S-C Wang) 學生 : 黃伯嘉 (Bo-Jia Huang) 2015/11/11 Temperature effects on the growth of SnS nanosheet structure using thermal decomposition.
Biosensors and Carbon Nanotubes
Synthesis and Characterization of a tri- metal catalyst used for the water electrolyzer and fuel cell NFL Lab.1 STUT, Mechanical Engineering SPEACH : En-Xian.
Reporter: Wen-Cheng Lin Teacher:Wei-Tung Liao. Outline Introduction Materials Experimental Results and discussion Conclusions.
指導老師 : 陳澄河 教授 研究生 :甘宜婷 報告日期 :
指導教授:王聖璋 博士 (Pro.S-C Wang) 學生 : 黃伯嘉 (Bo-Jia Huang) 2015/11/22 Temperature effects on the growth of SnS nanosheet structure using thermal decomposition.
The Detection of Glucose for the Carbon Paste Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chih-Ying Wu ( 巫致穎 ), Hau Lin.
The Operating Conditions for the Sensitivity of Detection of Hydrogen Peroxide for the Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao(
Experiment 5. A Rate Law and Activation Energy
Application of the Screen Printed Planar Electrode Modified with Ruthenium Hexacyanoferrate to Glucose Biosensor Kuo-Hsiang Liao( 廖國翔 ), Chung-Min Lien(
Section 13 Analytical Voltammetry.
Correlation between Nyquist plots for: (A) bare GCE and (B) SWCNT+PEI+HRP modified GCE in 10 mM K 3 [Fe(CN) 6 ] + K 4 [Fe(CN) 6 ], in phosphate buffer.
Study on the phase change cement based materials Min Li Southeast University, China Southeast University th International Conference on.
Introduction. During the last decade the interest in copper passivity significantly increased due to the important role of copper in microelectronic industry.
The Effect of Ratio of Meldola’s Blue to Carbon Powders and Carbon Paste on Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
The Effect of the Dilution Rate on the Dynamics of a Chemostat Chung-Te Liu ( 劉崇德 ), Chung-Min Lien ( 連崇閔 ), Hau Lin ( 林浩 ) Department of Chemical and.
S YNTHESIS AND CHARACTERIZATION OF C ROSS - LINKED CELLULASE ENZYME AGGREGATES (CLEA S ) BY ETHANOL AND ACETONE DESOLVATION TECHNIQUE Presentation by Jagdish.
BIOFABRICATION OF MEA GLUCOSE SENSORS Dry in air Ready for in vitro glucose detection (B) Chitosan biopolymer is electrodeposited on target electrode sites;
The pH on the Sensitivity of Detection of Hydrogen Peroxide for the Small Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chung-Min Lien ( 連崇閔.
Reporter : Shao-Fung Chiu Advisor : Cheng-Ho Chen Date : 2015/12/22 1.
The pH on the Detection of Hydrogen Peroxide for Electrode Modified with Chromium Hexacyanoferrate Chen-Hsun Hu ( 胡真熏 ), Ting-Li Lin ( 林庭立 ), Hau Lin (
Development of Microfluidic Glucose Sensors BME 273: Kristen Jevsevar, Jason McGill, Sean Mercado, Rebecca Tarrant Advisors: Jennifer Merritt, Dr. John.
Highly transparent solution processed In-Ga-Zn oxide thin films 指導教授 : 林克默博士 學生 : 董祐成 日期 :99/08/16 Y. Wang S. W. Liu X. W. Sun J. L. Zhao G. K. L. Goh.
Introduction. During the last decade the interest in copper passivity significantly increased due to the important role of copper in microelectronic industry.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chung-Min Lien ( 連崇閔.
A Study of Carbon Paste Electrode Modified with Platinum Particles and Ferrocene and Its Application to Glucose Biosensor Yi-Sheng Wang ( 汪乙生 ), Ting-Li.
Dr. Rasha Hanafi Lecture 8 Non- potentiometric methods of analysis: Amperometry and Voltammetry (Polarography) Dr. Rasha Hanafi Dr. Rasha Hanafi, GUC.
Introduction Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale,
Analytical Laboratory II
Electrochemistry MAE-212
Biosensors Definition
RESULTS AND DISCUSSION
Chen-Hsun Hu (胡真熏) , Chih-Ying Wu (巫致穎) , Hau Lin (林浩)
Presentation transcript:

Preparation of the Carbon Paste Electrode Modified with Ferrocene and Its Applications to Detection of Hydrogen Peroxide and Glucose Yi-Sheng Wang ( 汪乙生 ), Ting-Li Lin ( 林庭立 ), Hau Lin ( 林浩 ) Department of Chemical and Materials Engineering, Southern Taiwan University 南台科技大學化學工程與材料工程系 ABSTRACT A study was conducted to use the ferrocene to modify the carbon paste electrode which was used as the working electrode to detect the responding current of reduction of hydrogen peroxide and then the concentration of hydrogen peroxide could be obtained from the responding current and consequently, the concentration of the glucose could be determined. The TB (Time Base) graphs for different operating potentials, and pH values were plotted to determine the optimum operating conditions. The results showed that the responding current for the carbon paste electrode modified with ferrocene was elevated significantly. The optimum weight ratio for ferrocene : graphite carbon powders was 3 : 7. The optimum operating conditions are -200mV operating potential, 500rpm stirring rate and in 0.05 M PBS buffer solution( pH = 7.4 ). INTRODUCTION Nowadays, diabetes is one of the top ten causes of death for the people in Taiwan. Therefore, developing a rapid, convenient, and economical glucose biosensor for detecting the glucose is a very important research subject. The glucose and oxygen can be catalyzed by the glucose oxidase and the glucose is oxidized to gluconic acid and the oxygen is reduced to hydrogen peroxide. Because the ferrocene (Fe(C 5 H 5 ) 2 ) possesses the excellent conductivity and catalytic characteristic, it can be used to elevate the responding current for detection of reduction of hydrogen peroxide. A study was conducted to use the ferrocene to modify the carbon paste electrode which was used as the working electrode to detect the responding current of reduction of hydrogen peroxide in the phosphate buffer solution(PBS) and then the concentration of hydrogen peroxide could be obtained from the responding current and consequently, the concentration of the glucose could be determined. EXPERIMENTAL SECTION Equipment Electrochemical Analyzer (BAS 100W) was used to measure the activity of electrode by Cyclic Voltammetry ( CV ) and Time Base ( TB ) mode ; pH meter (Metrohm 731); Constant Temperature Thermal Bath (Wisdom BC-2DT 10L); Oven (DENG YNG) ; Electric Stirrer (Fargo); Carbon Paste Electrode was used as the working electrode, Coiled Platinum Wire was used as the counter electrode and Ag / AgCl was used as the reference electrode. Chemicals and Reagents Ferrocene(Fe(C 5 H 5 ) 2 ); Hydrogen Peroxide (H 2 O 2 ); D(+)-Glucose Monohydrate(C 6 H 12 O 6 ); Glucose Oxidase(EC , Type X-S: From Aspergillus Niger, units/mg); Graphite Carbon Powder; Carbon Paste; Cyclohexanone(C 6 H 10 O); Nafion ; Potassium Dihydrogenphosphate (KH 2 PO 4 ); Potassium Chloride (KCl). Procedure (1) Take one section of 7 cm electric wire with 0.05 cm inside diameter. After depriving the coating 0.5 cm length from both ends, the nake-ended wire was washed, dried and ready for use. 7 cm 0.05cm 0.5 cm (2) Then the ferrocene powders, graphite carbon powders and carbon paste were mixed with the appropriate ratio (ferrocene : graphite carbon powders : carbon paste = 0.3 : 0.7 : 1). After the mixing was complete, the mixture was evenly coated on the nake- ended electric wire and dried in the oven and then we obtained the carbon paste electrode. The surface area of the carbon paste electrode was cm 2. Ferrocene Mixing with carbon paste Graphite carbon powders Coated on the nake- ended electric wire glucose oxidase1 % Nafion PVC cover (3) After the above mentioned carbon paste electrode was dried, the 2μL glucose oxidase solution( 3mg of glucose oxidase was dissolved in 500μL PBS buffer solution ) was put onto the surface of electrode and the electrode was dried at room temperature. Then 5μL of 1% Nafion solution(in 95% alcohol) was dropped onto the electrode evenly and after the electrode was dried at room temperature, we obtained the glucose biosensor. RESULTS AND DISCUSSION Fig 1. CV graphs for (A) carbon paste electrode modified with ferrocene (B) unmodified carbon paste electrode; the range of scanning potential: -0.8 ~ +0.8 V, scanning rate = 50 mV/s Fig. 3 The TB graphs of carbon paste electrode for detection of H 2 O 2 at different pH values of PBS buffer solution (ferrocene : graphite carbon powders = 3 : 7); the pH values are [ (A) pH = 6.0 (B) pH = 7.0 (C) pH = 7.4 (D) pH = 8.0 ] Fig. 4 The TB graphs of carbon paste electrodes for detection of H 2 O 2 ; ; (A) carbon paste electrode modified with ferrocene (ferrocene : graphite carbon powders = 3 : 7); (B) unmodified carbon paste electrode Fig.5 The graphs for determining the linear range of detection of H 2 O 2 for carbon paste electrode [ (A) carbon paste electrode modified with ferrocene (B) unmodified carbon paste electrode ] Fig. 6 The TB graph of glucose biosensor for detection of glucose (ferrocene : graphite carbon powders = 3 : 7); At 30 ℃ ; the operating potential = –200 mV; in 0.1 M KCl of 5 mL 0.05 M PBS buffer solution ( pH=7.4 ); stirring rate=500 rpm; 20μL of 100mM glucose is injected per 100 seconds CONCLUSIONS The results showed that the responding current for the carbon paste electrode modified with ferrocene was elevated significantly. The optimum weight ratio for ferrocene : graphite carbon powders was 3 : 7. At 30 ℃, -200mV operating potential, and in 0.05 M PBS buffer solution( pH = 7.4 ), when the carbon paste electrode was modified with ferrocene [ferrocene : graphite carbon powders = 3 : 7 ( weight ratio )], the detection limit was 0.01 mM H 2 O 2, the linear range was 0.01 ~ 0.5 mM H 2 O 2, R 2 =0.993, and the sensitivity was μA/cm 2 . mM H 2 O 2. For the glucose biosensor, the detection limit was 0.06 mM C 6 H 12 O 6 ; the linear range was 0.06 ~ 2.0 mM C 6 H 12 O 6 ; R 2 = and the sensitivity was 83.1 μA/cm 2 . mM C 6 H 12 O 6. The optimum operating conditions are -200mV operating potential, 500rpm stirring rate and in 0.05 M PBS buffer solution ( pH = 7.4 ). REFERENCES 1. P. C. Pandey and S. Upadhyay, “Bioelectrochemistry of Glucose Oxidase Immobilized on Ferrocene Encapsulated Ormosil Modified Electrode,” Sensors and Actuators B, Vol.76,193 (2001). 2. M. A. Kim and W.-Y. Lee, “Amperometric Phenol Biosensor Based on Sol-Gel Silicate/Nafion Composite Film,” Analytica Chimica Acta, Vol.479, 143 (2003). 3. Y.-M. Uang and T.-C. Chou, “Fabrication of Glucose Oxidase/Polypyrrole Biosensor by Galvanostatic Method in Various pH Aqueous Solutions,” Biosensors and Bioelectronics, Vol.19, 141(2003). (A) (B) Fig. 2 The TB graphs of carbon paste electrode for detection of H 2 O 2 at different operating potentials (ferrocene : graphite carbon powders = 3 : 7); the operating potentials are [ (A) –300mV (B) –200mV (C) –100mV ]