Measuring Ocular Microtremor. The Brainstem Has 3 components 4 cranial nerves on each section.

Slides:



Advertisements
Similar presentations
Controller Tests Stephen Kaye Controller Test Motivation Testing the controller before the next generation helps to shake out any remaining.
Advertisements

1 iHome Automation System Home Automation System Team: Million Dollar Contingency Regiment Adam Doehling Chris Manning Ryan Patterson.
Fundamentals of Data & Signals (Part II) School of Business Eastern Illinois University © Abdou Illia, Spring 2015 (February18, 2015)
In this presentation you will:
Chapter 7 Principles of Analog Synthesis and Voltage Control Contents Understanding Musical Sound Electronic Sound Generation Voltage Control Fundamentals.
Data Acquisition Risanuri Hidayat.
Data Acquisition Concepts Data Translation, Inc. Basics of Data Acquisition.
Analog Sensing 101 WITH P Agenda  Analog Signal Characteristics  Common Problems with A/D Conversion  Clipping  Small Signals  Aliasing  Analog.
Mark Neil - Microprocessor Course 1 Digital to Analog Converters.
ELECTRICAL. Circuits Outline Power Hub Microcontroller Sensor Inputs Motor Driver.
1st practice Medical Informatics Biomedical Signal Processing TAMUS, Zoltán Ádám
WIMS Capstone Proposal DSP Demo Abigail Fuentes Rivera Esteban Valentin Lugo Michael Ortiz Sanchez ICOM 5047 Prof Nayda Santiago.
Team Impact Intelligent Helmet Impact System Preliminary Design Review January 29 th, 2008 Amanda Brodbeck Wei-Chu Liao Wei-Shen Liao Chris Mintle.
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
Aloha Proof Module Design Cabled Observatory Presentation School of Ocean and Earth Science and Technology February 2006.
Timers and Interrupts Shivendu Bhushan Summer Camp ‘13.
Kabuki 2800 “a real-time digital audio effects system for performance” team “Big Country” presents ECEN4610 Preliminary Design Review 14 September 2006.
PH4705/ET4305: Instrumentation Amp Our sensor will be connected to some kind of measurement system either directly, diag. 1, or as a bridge circuit diag.
Spectrum Analyzer Ray Mathes, Nirav Patel,
SMART House Kia Graham Tyangelio Gaines Ebony LeBlanc Southern University and A & M College College of Engineering and Computer Science Department of Electrical.
Optical Heart Monitor/Jump Drive Sponsor: Calit2 Mentor: Paul Blair Ph.D. Team: Matt Chandrangsu, Jeffrey Chi, Kari Nip ECE 191 – Group 6 Fall 2008.
Digital to Analogue Conversion Natural signals tend to be analogue Need to convert to digital.
Self-Calibrating Audio Signal Equalization Greg Burns Wade Lindsey Kevin McLanahan Jack Samet.
Lecture 1 Signals in the Time and Frequency Domains
Lecture 1. References In no particular order Modern Digital and Analog Communication Systems, B. P. Lathi, 3 rd edition, 1998 Communication Systems Engineering,
Technion – Israel Institute of Technology Department of Electrical Engineering Winter 2009 Instructor Amit Berman Students Evgeny Hahamovich Yaakov Aharon.
Chapter 13 Linear-Digital ICs. Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electronic Devices.
Multimedia & Communications ATMEL Bluetooth Background information on Bluetooth technology ATMEL implementation of Bluetooth spec.
Kaitlin Peranski Spencer Wasilewski Kyle Jensen Kyle Lasher Jeremy Berke Chris Caporale.
1 Biomedical Embedded Systems Technology Presentation for ENSC 440/305 Instructors: Dr. Andrew Rawicz, Steve Whitmore Department of Engineering Science.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
Data Acquisition Systems
Zach Molden Shamlan Al-Roomi NJ Purevsuren Raied Farash Aadiel Rizvi C ritical D esign R eview.
SIGMA-DELTA ADC SD16_A Sigma-Delta ADC Shruthi Sujendra.
Measuring Ocular Microtremor Thomas Rutkowski Vivian Phinney Salman Al-Saif Mark Hasemeyer Steve Carroll.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
IMAGE DATA ACQUISITION
High-Intensity Focused Ultrasound Therapy Array May1005 Alex Apel Stephen Rashid Justin Robinson.
ECEN 4610 Capstone University of Colorado Boulder, CO January 29, 2009 School of Rock PDR Cheyenne Aberle Drew Veldhuizen Swain Brooks Dan Reed.
The busy little Arduino in the TC1 A short tour Arduino/TC1 1.
Full Design. DESIGN CONCEPTS The main idea behind this design was to create an architecture capable of performing run-time load balancing in order to.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
HOT CAR BABY DETECTOR Group #20 Luis Pabon, Jian Gao ECE 445 Dec. 8, 2014.
ELECTRONIC STETHOSCOPE ARRAY Groupe 70 Robin GUIGNY & Fatima Zohra HASNAOUI ECE 445 Spring 2016.
Automatic Guitar Tuner Group #10 Dariusz Prokopczak & Stephan Erickson ECE 445 Sr. Design December 9, 2014.
EKT 314/4 WEEK 5 : CHAPTER 3 SIGNAL CONDITIONING ELECTRONIC INSTRUMENTATION.
Sound Source Location Stand Group 72: Hiroshi Fujii Chase Zhou Bill Wang TA: Katherine O’Kane.
Electromyography E.M.G..
On-Site HotBox Calibration System Team 2 Pourya Assem & Paul Lupas Prof. A.C.Singer ECE 445 – Fall 2012.
Radio Equipment. Review: On the Transmitter Side The purpose of radio communications is to transfer information from one point to another. The information.
Electronic Devices and Circuit Theory
Developing a Sonar Sub-System for a Submarine to Obtain Time Delays between Received Signals Gary Eades Dy Eang Diana Fuertes 12/04/2007 ECE4884 L03 Dr.
P10203 LV1 MOTOR CONTROLLER FINAL REVIEW MAY 14, 2010 Electrical: Kory Williams, Adam Gillon, Oladipo Tokunboh Mechanical: Louis Shogry, Andrew Krall.
Components of Mechatronic Systems AUE 425 Week 2 Kerem ALTUN October 3, 2016.
Emotional Intelligence Vivian Tseng, Matt Palmer, Jonathan Fouk Group #41.
Home automation using Arduino & ‘PIR sensor’
(4) Filters.
Voice Manipulator Department of Electrical & Computer Engineering
BI-day 2014, The SEM-grid renovation project Michel Duraffourg
Chapter 13 Linear-Digital ICs
Embedded Systems Design
Electromyography E.M.G..
Measurements of digital signals with spectrum analyzers
Electromyography E.M.G..
Measurements of digital signals with spectrum analyzers
Fundamentals of Data & Signals (Part II)
Chapter 10 Intelligent Sensor Systems Prof. Dehan Luo
M. Kezunovic (P.I.) S. S. Luo D. Ristanovic Texas A&M University
Embedded Sound Processing : Implementing the Echo Effect
Presentation transcript:

Measuring Ocular Microtremor

The Brainstem Has 3 components 4 cranial nerves on each section

Assessing Brainstem Activity “High Tech”  BIS Technology Expensive (sensors & trained technicians) Can’t use if swelling from head injuries  Glasgow Coma Scale “Low Tech”  Cranial Nerves

Unconscious Patients Very uncomfortable procedures to assess intactness of cranial nerves  Flush 60 oz. of ice cold water in ear

Ocular Microtremors (OMT) OMT have been shown in clinical studies to accurately reflect brainstem activity Ocular motor nerves originate in the brainstem where sensory signals are pre- processed and sent to the cerebrum Oculo-motor nerves originate in the brainstem These signals are necessary for consciousness

Packaging & Architecture Incorporate a disposable element into the sensor mounting apparatus. Redesign and re- package the electronics for miniaturization and packaging for in-line dongle-type element on the cable. Objective 1

Objective 2 Signal Processing - Signal processing for signal amplification and/or noise reduction

Objective 3 Integration Into Patient Overhead Monitor Research and understand the standard(s) used to integrate into this technology Implement in software with potential hardware modifications for the physical interface.

Current Trend Analysis Software

Component Overview Waveform Generator OMT Simulator Sensor (Provided) Power Supply Analog Input/ Preprocessing Circuitry - Amp Test MUX XRAM Microprocessor with Integrated A/D, UART, and DSP Bedside Monitor (Philips MP-60/70 or Agilent V24/26) Philips VueLink Module – M1032A For MCU, currently looking at Atmel AVR32 with 12-bit A/D and integrated DSP functions,50 MHz clock.

OMT Sensor Composed of a piezoelectric transducer, and a surface mount IC amplifier The sensor generates voltage when it undergoes stress, in this case eye movement The piezoelectric transducer was designed to be really sensitive to slight amounts of stress

Power Management The current “Blackbox” is powered by a medical grade power supply which provides ±12V for the sensor, and 5V for the processing unit The Atmel AVR32 processor has a maximum voltage rating of 3.6V The interface module to the bedside monitor will be powered by the monitor itself

Originally the bedside monitor was going to be used to power both the processor and sensor Power options Dual PS/2 – output voltage 5V ±10% Dual MIB/RS232 – output voltage 5V ±5% USB 2.0 – low power mode, output voltage 4.4V It is more convenient to construct our own custom power supply that is capable of powering both the sensor and processor Power Management continued

Power Flow Sensor Power supply Signal processing unit Monitor interface Bedside monitor

Sample Signal until XRAM Buffer Full Perform DSP Algorithm on Buffer Contents Extract Necessary Data From DSP Output Send Wave Samples, Freq, and Amp. to UART(Monitor) Broad Overview of Software

Sampling Sampling will be interrupt driven, and will continue until a buffer a buffer is filled. Buffer must be large enough for an adequate analysis of signal. When the first buffer is full, the DSP algorithm will be started on the signal and sampling will continue to a secondary buffer of equal size. Sampling and DSP will alternate between buffers so no data is lost. The buffer size and sampling rate will be configurable over the UART. A/D DSP Buffer 1 Buffer 2 XRAM DSP Output Bus

FFT – Generate Output Array in XRAM Search Valid Range of Array for Max Energy Zero Out Locations Outside of OMT Range (Filter) Inverse FFT to Obtain Filtered Waveform in Time Domain FFT Method Amplitude/ Frequency Output Filtered Waveform Output -An FFT is performed on the contents of the sample buffer, with spectrum data saved to an array. -The array locations corresponding to the valid OMT range are searched for the maximum energy, giving the Frequency and Amplitude of the OMT signal. -An inverse FFT on only the valid OMT frequency range is required to reconstitute a time-domain waveform that can be sent to the bedside monitor.

Digital HPF/LPF/Notch Filter Routines Modify Buffer Filtered Waveform Output Peak-Count and Amplitude- Averaging Algorithm Amplitude/ Frequency Output Peak-Detection Method -Digital filter routines modify the contents of the buffer, giving a filtered signal that could be sent to the bedside monitor. -Positive-to-negative changes in slope are counted, giving the frequency. The amplitudes at which this occurs are averaged. Wavelets – Short Oscillations of a given frequency. Can be compared to our signal to determine if energy at that frequency is present.

Bedside Monitor Interface Philips VueLink Module 1032A RS-232 Input – Open Interface Protocol Allows 1 Waveform (OMT Signal), 2 Numerics (Amplitude and Frequency), Diagnostic Messages (ex. OMT out of valid range), and Alarms (ex. OMT below certain value) SDM_VueLink_Installation_Manual.pdf

Testing and Data Mining Important in order to determine the pattern and/or trend of OMT signals Determining a pattern is vital to the signal processing component The process involves a subject (one of us) to lie down and have the sensor mounted on a closed eyelidusing surgical sensitive tape Due to a lack of FDA approval and other required certification, we will not be able to gather data on a large scale basis

Vivian’s OMT

Mark’s OMT

Division of Labor

Schedule First MilestoneSecond MilestonePre-Expo GrantsThroughout Semester

Budget

Interference Concerns Accidental patient movement Electrical noise from other equipment in the ICU room Noises in excess of 95 dB Heartbeat

Contingencies Software implementation of display if bedside monitor is not able to be acquired Scaling number of processors to ensure proper operation Purchasing additional components to ensure minimal downtime especially before expo

Risks During application of sensor patients’ eye may be agitated Additional cord is hanging off of patient Possibility of dongle removing sensor from patients’ eye if too heavy Components may be destroyed if wired incorrectly

Extension possibilities Add through connections in order to minimize hanging cables Adding accelerometer to measure patient movement to find bad samples

Questions?