Developing situation … becomes a fire … if detected … triggers extinguishing … ending in loss www.puzzltec.com 305-359-3752 phone Hazardous Temperature.

Slides:



Advertisements
Similar presentations
Linear Heat Detection From Cables Britain Limited Unit 6 Waterfall Lane Trading Estate Waterfall Lane, Cradley Heath Warley, West Midlands Tel:
Advertisements

Inspection & Preventive maintenance of breakers
The Role Of Gas Monitoring In The Prevention And Treatment Of Mine Fires Darren Brady Manager, OHECC Simtars Department of Mines and Energy.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
June 2010 At A Glance The Room Alert Adapter software in conjunction with AVTECH Room Alert™ devices assists in monitoring computer room environments as.
Protecting Your School Assets Through Loss Control.
MCTS GUIDE TO MICROSOFT WINDOWS 7 Chapter 10 Performance Tuning.
Remote Monitoring and Management Solutions ®
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
The Role of Global Positional Systems in Policing and Crime Prevention William J. Artis Jr. FRS 142: Where’s Waldo April 19, 2004.
Condensation Piping and Installation Drain Pans
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
Vibration Sensors for Cooling Towers Challenges Cooling towers offer the vibration analyst many challenges in sensor selection, mounting and environmental.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
1 ASPIRATING SYSTEMS TRAINING e-series. 2 Overview e-series model range ASD Software  NetTracer  Detector Monitor  PipeTracer.
High Efficiency Commercial Gas HCG Series. 2 American HCG Series The HCG Series High Efficiency Commercial Gas Water Heaters embody all that’s great about.
What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected until a security guard noticed.
07 October ‘04 JCOV R. Lindner Water leak detection at LHCb Detection of cooling water leaks below electronic racks.
1 Software Testing and Quality Assurance Lecture 38 – Software Quality Assurance.
Hydrogen R&D system HAZOP and failure analysis Yury Ivanyushenkov, Elwyn Baynham, Tom Bradshaw, Mike Courthold, Matthew Hills and Tony Jones.
Wireless Remote Control Derail System CSX Atlanta, GA Track and Derail Graphic layout CSX Atlanta, GA.
Data Logging GCSE ICT. Learning Intentions: To explore the tern data logging. To explore the concept of analogue and digital data and the need for conversion.
Rohrback Cosasco Systems, Inc.
Data Processing Equipment
Alarmline Linear Heat Detection
Chapter 8: Disaster Management
Basic Construction.  Prevent injuries to people  Maintain a safe environment for workers  Reduce hazards  Reduce machinery breakdowns.
Linear Heat Detection.
Rulemaking PacifiCorp Responses to ALJ Ruling May 26, 2015.
Fleet Performance and Reliability in Generation Utilities
Real Time Process Control (Introduction)
MCTS Guide to Microsoft Windows 7
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
Unit Objectives  Describe the types of hazards to which your community is vulnerable.  Describe the functions of CERTs.  Identify preparedness steps.
Unit Objectives  Describe the types of hazards to which your community is vulnerable.  Describe the functions of CERTs.  Identify preparedness steps.
A Military Logistics and Transportation Security Application.
23-aug-05Intrusion detection system1. 23-aug-05Intrusion detection system2 Overview of intrusion detection system What is intrusion? What is intrusion.
Event Management & ITIL V3
Heart Rate Monitor (HRM). Measurement of HR Plethysmograph or ECG techniques ECG superior as distinguishable R peak HR derived by – Sensors: Limb or.
SiteWiz – RiT ’ s CAM Solution. Daily IT Challenges Overload of infrastructure information Numerous daily changes Many departments involved No clear picture.
1 December 1, 2011 Barry Boguski District Manager, Industrial Scientific Industrial Scientific – Gas Detection Programs.
Office of Aviation Safety Nancy B. McAtee Office of Research and Engineering Fire Investigation.
Conditioned-Based Maintenance
Software Testing and Quality Assurance Software Quality Assurance 1.
Cybermotion is pleased to present to The Office of Homeland Security …Beyond the humanly possible !
Presents The NetBotz Homeland Security Solution A Texas Company Protecting Texans.
Situational Awareness UPDEA - Workshop. Awareness of the Situation 25,623 Alarms in 8 Hours 53 Alarms / min (average) 80% Are consequential Things to.
Managing a Power System with 40% Wind Dr Alan Rogers EirGrid.
Cctv Management Solution - CMS From – Intelitech Solutions Pvt. Limited. [ ITSPL Group ]
What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected until a security guard noticed.
March 8, 2006Exp. Area Meeting - E. Thomas1 Oxygen Deficiency Hazards Detection System in UX85 Two risks – Two systems 1.Top : He leaks 2.Bottom : CF4.
Missing Plane Disasters – 2014 part-2 Mitigation through adding - Accountability, Visibility & Responsibility SYSM 6309 Advanced Requirements Engineering.
“We Bring Engineering to Life” 2015 Agent Training Grant Ellington Nov. 18, 2015.
Solution Overview 2015 Connected Farm. Field Rainfall IrrigationFleet Plant Health Soil.
Specialized software for shipping!
1 Crisis Management and Communication Dr. Joy Smith and Ms. Robin Denny.
Multiple Module Vacuum Oven Productivity Enhancement System.
Pressure Governor System Electronics. 2 Sentry Pressure Governor System Description The Sentry Pressure Governor System (SPGS) is a J1939 CAN based pressure.
1 Software Testing and Quality Assurance Lecture 38 – Software Quality Assurance.
How selected hoist overload limiter. How should hoist overload limiter Selection Electric hoist is a motor, reducer and rope reel (or chain) as one of.
Page 1 NeSSI II - A Platform for Micro-Analytical Devices Sensor Actuator Manager (SAM) Controller Considerations And Specification Identification CPAC.
Flame & Smoke Detection System Flame & Smoke Vision Detection is an intelligent vision-based analytics system which can timely detect suspicious fire or.
Fire Service Incidents. Today’s fire service does much more than fight fires. The Fire Service has become the primary source of emergency response and.
Security Methods and Practice CET4884
Implementing eMaintenance using i SCADA technology for Wisma Persekutuan Melaka By Nurhaizan JKR Mekanikal Melaka Case Study Published by permission and.
Scorpion is a remote tester specifically designed for testing ASD systems. Scorpion is compatible with the FAAST aspirating smoke detector. It is particularly.
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model
UNMANNED INTELLIGENT MILITARY ROBOT USING ZIGBEE
OVERFLOW + IGNITION = TANK FARM FIRE.
OVERFLOW + IGNITION = TANK FARM FIRE.
Presentation transcript:

Developing situation … becomes a fire … if detected … triggers extinguishing … ending in loss phone Hazardous Temperature Locator / Valuator System Developing situation … is detected … located … evaluated … and abated … without loss Common Fire Alarms Detect Fires Early Abnormal Temperature Detection and Intervention Total Temperature Information Management Determines normative temperature behavior, monitors and logs it. Detects abnormal temperature behavior, evaluates level of intervention needed, provides alerts and takes action, logs event. Archival information provides key analysis tools to investigate abnormal events to prevent reoccurrence. Allows assets to operate consistently in their normal temperature zones.

Hazardous Temperature Locator / Valuator System Provides Total Temperature Information Management in a Wide Range of Aircraft Applications Cargo Bays Fuel Tanks Special Containers Power Plants Power Systems, Cable Harnesses Auxiliary Power Unit Avionics, Controls, Wire Trays Hydraulics Cable/Wire Trays Galleys and Heads

Unique Sensor and Powerful Real-Time Information System Provide Unprecedented Functionality and Security HTLS ALERTS, ALARMS, INITIATES PREDETERMINED ACTION TO AVERT DAMAGE AND LOSSES HTLS CONTINUOUSLY ARCHIVES ALL INFORMATION FOR:  Total Temperature Information Management  Root Cause Analysis HTLS DETECTS, LOCATES and DISPLAYS abnormal temperature events between -40 and 1490 degrees F Highest Temperature Location and Value Highest Temperature Value Temperature Rate-of-Change Duration of Specific Event Hazardous Temperature Locator / Evaluator System (HTLS)

Teflon Jacket, Flexible Type K Element. Up to 2000 ft maximum length. ® -40 to 350˚F (-40 to 150˚C) Element weight: 1.63 lb per 100 feet Bendable Inconel® Sheathed Type K Element. Up to 140 ft maximum length. ® -40 to 1490˚F (-40 to 810˚C) Element weight: 2.56 lb per 100 feet Hazardous Temperature Locator / Valuator System - Aircraft Applications Two Types of Sensor Element for Every Application from from – 40 to 1490 degrees F High Temperature, Hostile, Rugged Environments

Abnormal Temperature Event 121˚ F Zone V Rate of Rise 5.2 ˚ F/minute Event Duration: 8 minutes System Status: Capable/Active Abnormal Temperature Event 121˚ F Zone D6 Rate of Rise 5.2 ˚ F/minute Event Duration: 8 minutes System Status: Capable/Active Hazardous Temperature Locator / Valuator System - Aircraft Applications Wide Variety of Intelligent Display Possibilities Sequence of Events / Priority Location Abnormal Temperature Event Graphic Display Location/Value/Trend/Log Display Abnormal Temperature Event Quick Alert Real-Time Event Alarm/ Action Log Archival Event Log

Hazardous Temperature Locator / Valuator System Detects the Location and Highest Temperature Value Sensed anywhere along its length and provides the following Real-Time Information: Precise Location of Highest Temperature Value of Highest Temperature and Instantaneous Rate-of-Change Archive and Sequence-of-Events Analysis Sensor and System Condition / Status Aviation, Transportation, Military, Airports, Warehousing, Tunnels, Mines, Caves, Utility and Cableways - Unique Lightweight* Sensor and Advanced Electronics System Provide Unparalleled Use of Continuous Real-Time Information * 16.4 lb per 1000 feet of Teflon Jacketed Sensor Element; 25.6 lb per 1000 feet of Inconel Sheathed Sensor Element Detects – Locates – Indicates – Alerts – Archives- Analyzes

-Unique Sensor and Powerful Real-Time Information System Provide Unprecedented Functionality and Security Unlike fixed-point fire sensor systems, HTLS continuously monitors and archives the highest temperature during NORMAL operation in the range of -40 and 350 degrees F (Teflon) or -40 and 1490 degrees F (Inconel). (HTLS is always working, always ready).  HTLS DETECTS and DISPLAYS any abnormal temperature event. o Improperly functioning or overheating equipment, power overloads o Breached containment, leaks o Deteriorated insulation and seals  HTLS PRECISELY LOCATES any abnormal temperature event.  HTLS ALERTS, ALARMS, TAKES PREDETERMINED ACTION. System can be configured to suggest corrective action to operator. HTLS can combine abnormal temperature information with other real-time information about aircraft operation to facilitate on-line real-time operations analysis.  HTLS CONTINUOUSLY ARCHIVES ALL INFORMATION for later investigation: o Normal Operations Analysis – the aircraft operates the same correct way each time during normal operation – temperatures within their normal predictable range. o Root-Cause Analysis – finding specific underlying causes for variability in temperatures during normal operation, or abnormal temperature events that without intervention, could lead to fire or explosion with ensuing losses and damage.