Partial Parallel imaging (PPI) in MR for faster imaging IMA Compressed Sensing June, 2007 Acknowledgement: NIH Grants 5RO1CA092004 and 5P41RR008079, Pierre-Francois.

Slides:



Advertisements
Similar presentations
In Chan Song, Ph.D. Seoul National University Hospital
Advertisements

Statistical Parametric Mapping
Evaluation of Reconstruction Techniques
Figure 2. Signal level (left) degrades with slice offset and slice thickness when Z2 SEM is used in GradLoc imaging (ROI = FOV/2). To recover the full.
Parameters and Trade-offs
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Principles of MRI: Image Formation
1 Temporal Processing Chris Rorden Temporal Processing can reduce error in our model –Slice Time Correction –Temporal Autocorrelation –High and low pass.
Basics of fMRI Preprocessing Douglas N. Greve
Image Reconstruction T , Biomedical Image Analysis Seminar Presentation Seppo Mattila & Mika Pollari.
Bruce Fischl MGH ATHINOULA A. MARTINOS CENTER Harvard Medical School MIT CSAIL/HST some open issues in functional MRI (thanks to Larry Wald for almost.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D..
Real-Time MRI – Outline Biomed NMR JF11/59 Technical Considerations - Data Acquisition - Image Reconstruction Preliminary Applications - Joint Movements,
Magnetic resonance is an imaging modality that does not involve patient irradiation or significant side effects, while maintaining a high spatial resolution.
Steady-state free precession and other 3D methods for high-resolution FMRI Steady-state free precession and other 3D methods for high-resolution FMRI Karla.
EPI – Echo Planar Imaging Joakim Rydell
2D-CSI in a fraction of the time using multiple receiver coils Simon J. Doran 1, Adam J. Schwarz 2 and Martin O. Leach 2 1 Department of Physics, University.
Psy 8960, Fall ‘06 Parallel Imaging1 SMASH and SENSE High field advantage Pros and cons … But first, review of last few homework assignments.
Psy 8960, Fall ‘06 Fourier transforms1 –1D: square wave –2D: k x and k y Spatial encoding with gradients Common artifacts Phase map of pineapple slice.
FMRI: Biological Basis and Experiment Design Lecture 7: Gradients and k-space FFT examples –Sampling and aliasing Gradient Gradient echo K-space
A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.
Compressed Sensing for Chemical Shift-Based Water-Fat Separation Doneva M., Bornert P., Eggers H., Mertins A., Pauly J., and Lustig M., Magnetic Resonance.
2D FT Imaging MP/BME 574. Frequency Encoding Time (t) Temporal Frequency (f) FT Proportionality Position (x, or y) FT Proportionality Spatial Frequency.
MRI Image Formation Karla Miller FMRIB Physics Group.
Medical Imaging Systems: MRI Image Formation
Principles of MRI Physics and Engineering
Imaging Sequences part II
© NIH National Center for Image-Guided Therapy NCIGT Project Week Fast Imaging Library W. Scott Hoge and Bruno Madore.
Statistical Parametric Mapping Lecture 9 - Chapter 11 Overview of fMRI analysis Textbook: Functional MRI an introduction to methods, Peter Jezzard, Paul.
Parallel Imaging Reconstruction
Medical Imaging Systems: MRI Image Formation
Jason P. Stockmann 1 and R. Todd Constable 1,2 Yale University, Department of Biomedical Engineering 1, Department of Diagnostic Radiology 2, New Haven,
HOW TO OPTIMIZE MRI OF EXTREMITIES ?
Seeram Chapter 7: Image Reconstruction
Contrast Mechanism and Pulse Sequences Allen W. Song Brain Imaging and Analysis Center Duke University.
EE369C Final Project: Accelerated Flip Angle Sequences Jan 9, 2012 Jason Su.
Correcting for Center Frequency Variations in MRSI Data Using the Partially Suppressed Water Signal Lawrence P Panych, Ph.D., Joseph R Roebuck, Ph.D.,
RSL/MRSL Journal Club VIPR/Radial MRI Kitty Moran.
Daily fMRI Practice John Li MD 9/27/2012. When you preparing a fMRI study, you need to Read and understand the fMRI requirements. Design and choose proper.
HighlY Constrained Back PRojection (HYPR) Thank you to Oliver Wieben!!
G Practical MRI 1 Gradients.
Allen W. Song, PhD Brain Imaging and Analysis Center Duke University MRI: Image Formation.
Lecture 7: Sampling Review of 2D Fourier Theory We view f(x,y) as a linear combination of complex exponentials that represent plane waves. F(u,v) describes.
Contrast Mechanism and Pulse Sequences
Jason P. Stockmann 1, Gigi Galiana 2, Leo Tam 1, and R. Todd Constable 1,2 Yale University, Department of Biomedical Engineering 1, Department of Diagnostic.
Image Reconstruction using Dynamic EPI Phase Correction Magnetic resonance imaging (MRI) studies using echo planar imaging (EPI) employ data acquisition.
GPU Accelerated MRI Reconstruction Professor Kevin Skadron Computer Science, School of Engineering and Applied Science University of Virginia, Charlottesville,
2D Sampling Goal: Represent a 2D function by a finite set of points.
Conclusions Simulated fMRI phantoms with real motion and realistic susceptibility artifacts have been generated and tested using SPM2. Image distortion.
An Assessment of O-Space Imaging Robustness to Local Field Inhomogeneities Jason P. Stockmann and R. Todd Constable #549Session – Parallel Imaging: Stretching.
MR Image Formation FMRI Graduate Course (NBIO 381, PSY 362)
Declaration of Relevant Financial Interests or Relationships David Atkinson: I have no relevant financial interest or relationship to disclose with regard.
Magnetic Resonance Learning Objectives
DTI Acquisition Guide Donald Brien February 2016.
J OURNAL C LUB : “General Formulation for Quantitative G-factor Calculation in GRAPPA Reconstructions” Breuer, Griswold, et al. Research Center Magnetic.
Receive Coil Arrays and Parallel Imaging for fMRI of the Human Brain
Nicole Seiberlich Workshop on Novel Reconstruction Strategies in NMR and MRI 2010 Göttingen, Germany 10 September 2010 Non-Cartesian Parallel Imaging based.
FAST DYNAMIC MAGNETIC RESONANCE IMAGING USING LINEAR DYNAMICAL SYSTEM MODEL Vimal Singh, Ahmed H. Tewfik The University of Texas at Austin 1.
Fast Dynamic magnetic resonance imaging using linear dynamical system model Vimal Singh, Ahmed H. Tewfik The University of Texas at Austin 1.
SWIFT Dual Breast Imaging Sequence and Coil with Interleaved Adiabatic Fat Suppression high temporal and spatial resolution #3369 Computer 8 breast imaging.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
Super-resolution MRI Using Finite Rate of Innovation Curves Greg Ongie*, Mathews Jacob Computational Biomedical Imaging Group (CBIG) University of Iowa.
He-Kwon Song, PhD Associate Professor & Co-investigator in the CMROI, Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia,
CT Multi-Slice CT.
FMRI data acquisition.
Assume object does not vary in y
Proposed (MoDL-SToRM)
Parallel Imaging Artifacts in Body Magnetic Resonance Imaging
Sunday Case of the Day Physics (Case 1: MR)
Presentation transcript:

Partial Parallel imaging (PPI) in MR for faster imaging IMA Compressed Sensing June, 2007 Acknowledgement: NIH Grants 5RO1CA and 5P41RR008079, Pierre-Francois Van de Moortele, Gregor Adriany, Kamil Ugurbil

Our coils  Open face coil  16 Channel “closed” coil

Intrinsically, surface coils offer a representation of signal as Acquired k-space, How to INTERPOLATE most stably to the Non-acquired data. we will see why it makes completely sense to think about interpolation The sensitivities are complex valued

Field of View Courtesy: Douglas Noll, University of Michigan

Undersampled images Undersampled individual images

The linear system The solution of the linear system gives rice to a spatially varying noise amplification. This is solely dependent on the sensitivities and is referred to as the geometry factor

The geometry factor α is the index of an aliased pixel, β n is the index of an unaliased pixel. The reduced FOV is the RSOS of all the channels with a reduced FOV, only for illu. Overall loss when using PPI is SNR red =SNR full /(g sqrt(R))

Back to the equation S indv. Channels. E encoding. p un-aliased image S indv. Channels. E encoding. p un-aliased image (all in k- space) K-space Image space Convolution operator

E is known, but we can make the formal separation of S, as follows: Two matrix equations, two unknowns E ”acq” includes all of k-space for the sensitivities

 SENSE/SMASH formalism (get one image) GRAPPA idea, get multiple images. The interpolation is essentially similar to Kriging

Courtesy: Yeh, et al, MRM Volume 53, Issue 6, Pages

GRAPPA Reconstructing the data for EACH coil Courtesy: Griswold et al. MRM, 47(6): (2002)

Several reconstruction is found for EACH k-space point- due to the blocks. A weigthed average is used to compute just one

 GRAPPA formula to reconstruct signal in one channel  ACS (Auto-Calibration Signal) lines (no x) where A represents the acceleration factor. N b is the number of blocks used in the reconstruction, where a block is defined as a single acquired line and A-1 missing lines. 4-8 blocks are needed,l,l

Temporal sampling PE Interleaved/segmented (2) Interleaved (2) Works well for imaging of static objects. For dynamic imaging, each image is not only undersampled, but also captures a different part of the “motion”/”change”. The acquisition is assumed faster than the motion time ½ k- space

PSF considerations (generally)  Let us start with imaging PE or t Standard PPI used to “unalias” the effects of the psf

UNFOLD (does not require multichannels)  Specifically, alternate the sampling by a factor 2, such that Remove aliasing by … ½ k- space Courtesy: Madore. MRM 48:493 (2002).

fMRI (UNFOLD) FIG. 16. Results obtained for a single-trial fMRI experiment (4 spiral interleaves, 16 kz phase-encode values, axial images, matrix size , TR msec, TE 5 40 msec, 5 mm resolution along z, 24 cm FOV). Bilateral finger tapping was performed while a 2 sec audio cue was on, and then stopped for 12 sec. The acquisition time for a time frame (16 sec) is longer than a paradigm cycle (14 sec). UNFOLD is used to reduce the acquisition time by a factor 8, providing 7 frames per paradigm cycle. a: The acquired frames are corrupted by an 8-fold aliasing in the through slice direction. b: Temporal frequency spectrum for the highlighted image point in a. UNFOLD interleaves 8 spectra into the same temporal bandwidth. Marks are placed on the axis at the locations of the DC, fundamental and harmonic frequencies for the non-aliased material. Selecting only these frequencies, the aliasing seen in a is removed in c. Remove aliased frequency by selective filtering Courtesy: Madore. MRM 48:493 (2002).

Extend the concept of aliasing Line in image Unalias the support in x-f space, just like we unalias in x space with SENSE Tsao et al, MRM 50: (2003)

DATA challenge 1. Where is the support in x-f space? Used to define support in x-f space “Equivalent” to a reference scan Interleaved training set Similar concepts hold for radial, where the center is the “prior”. This is used in speech imaging Tsao et al, MRM 50: (2003)

How do the methods compare? k-t SENSE, vs. Sliding Window  Consensus (in cardiac imaging) of: Xu et al. MRM, 57: (2007)

What does the artifact mean Xu et al. MRM, 57: (2007)

Looking at the temporal variation (in speech [radial]) K-t SENSE Sliding window t y Comments/Conclusions Michael S. Hansen. Workshop on Non-catesian MRI. 2007

Formally With localized sensitivities (smooth in image space) The mising information can be determined from the acquired data, if the coeeficients a(i,j,k) are known

SMASH  Find weights n k (m) (x) [no x –readout dependence] such that we get a new synthetic sensitivity profile C m comp WE do parallel Imaging by finding ONE combined image (just like SENSE) m is selected depending on how FAR the data must be interpolated. Only one line is used to advance the data

Generalised SMASH  Find weights a k (m) (x) [with x – readout dependence] such that (x) Express  We use several phase-encoding lines to generate missing information. For each readout point a new set of weights are comp.

Two severe issues  The final image is that of a complex sum image of the individual images. Not optimal for SNR  Total cancellation can occur with such complex sums.  Coils where phase-aligned PRIOR to reconstruction

AUTO-SMASH  ACS (Auto-Calibration Signal) lines (no x), not fitting to a harmonic, but a “missing” PE-line