Trinity Charging Experiment Gregg Harry, MIT On behalf of Dennis Ugolini, Trinity LIGO-G060462-00-R.

Slides:



Advertisements
Similar presentations
Commercial IFOGs.
Advertisements

CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
LASER BASED SENSOR FOR DETECTION OF TRACE GASES IN THE ENVIRONMENT M. A. Gondal, I. A. Bakhtiari and Z. H. Yamani Laser Research Laboratory & Physics.
CURRENT RAMPING.
Testing Ferroelectric and Piezoelectric Samples in an AFM Radiant Technologies, Inc April 22, 2004.
Wednesday, Oct. 26, 2005PHYS , Fall 2005 Dr. Jaehoon Yu 1 PHYS 1444 – Section 003 Lecture #16 Wednesday, Oct. 26, 2005 Dr. Jaehoon Yu Charged Particle.
A possible new method for Neutrino mass measurement.
Cutnell/Johnson Physics 8th edition
1 Chapter 5 Sensors and Detectors A detector is typically the first stage of a communication system. Noise in this stage may have significant effects on.
Fiber-Optic Communications
Microwave Spectroscopy I
Sample servo diagrams and Bode plots. Acousto optic performance plots Unlock servo Measure gain and phase vs drive input K.
Topic 12: Electromagnetic induction. 16/07/ Topic 12: Electromagnetic induction Describe the inducing of an emf by relative motion between a conductor.
Conductors are commonly used as places to store charge You can’t just “create” some positive charge somewhere, you have to have corresponding negative.
Pulse Width Modulation (PWM) LED Dimmer Circuit
The following schematic displays the general setup of the Dunk Probe test. The Aluminum sample tested during this run (DSAT3) had a thickness of 200nm.
Pulse Width Modulation (PWM) LED Dimmer Circuit
JIT HW 25-9 Conductors are commonly used as places to store charge You can’t just “create” some positive charge somewhere, you have to have corresponding.
Electrical Fundamentals
Electricity, Electronics And Ham Radio “Kopertroniks” By Nick Guydosh 4/12/07.
LIGO-G Z D. Ugolini, LSC March Progress Report on Charging Measurements at Trinity University Dennis Ugolini, Robert McKinney, Mark Girard.
LIGO-G Z D. Ugolini, Charging Workshop July UV Illumination Studies at Trinity University Dennis Ugolini, Mark Girard 2007 Workshop on.
Semiconductor Devices III Physics 355. Transistors in CPUs Moore’s Law (1965): the number of components in an integrated circuit will double every year;
6-1 EE/Ge 157b Week 6 EE/Ae 157 a Passive Microwave Sensing.
F.M.H. Cheung School of Physics, University of Sydney, NSW 2006, Australia.
Topic 12: Electromagnetic induction 12.2 Alternating current
LIGO-G Z D. Ugolini, LSC March Developing a Kelvin Probe for Measuring Surface Charge on LIGO Optics Dennis Ugolini, Robert McKinney Trinity.
Electromagnetism Topic 12.2 Alternating Current. Rotating Coils Most of our electricity comes from huge generators in power stations. Most of our electricity.
PHY 202 (Blum)1 Analog-to-Digital Converter and Multi-vibrators.
Electric Current and Ohm’s Law
G O D D A R D S P A C E F L I G H T C E N T E R Surface Potential Measurements with the LISA Kelvin Probe Jordan Camp LIGO/LISA Charging Workshop July.
Measurements of stray field in the NLCTA area Josef Frisch, Peter Tenenbaum, Tor Raubenhemier.
Copyright © 2009 Pearson Education, Inc. EMF Induced in a Moving Conductor.
Measuring Phase Difference Dr. Len Trombetta 1 ECE 2100.
* Power Source with no loss in load current * Capacitor Input circuit generates about 10% of load current loss, twice in every cycle.
Thursday, Nov. 3, 2011PHYS , Fall 2011 Dr. Jaehoon Yu 1 PHYS 1444 – Section 003 Lecture #18 Thursday, Nov. 3, 2011 Dr. Jaehoon Yu Torque on a Current.
Test mass charge relaxation V.P.Mitrofanov, P.E.Khramchenkov, L.G.Prokhorov Moscow State University LIGO/VIRGO LSC Meeting, Baton Rouge, March 2007 G Z.
Tutorial 4 Derek Wright Wednesday, February 9 th, 2005.
Inductance and AC Circuits. Mutual Inductance Self-Inductance Energy Stored in a Magnetic Field LR Circuits LC Circuits and Electromagnetic Oscillations.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
Thursday March 31, PHYS Dr. Andrew Brandt PHYS 1444 – Section 02 Lecture #16 Thursday Mar 31, 2011 Dr. Andrew Brandt HW7 Ch 27 is due Fri.
Given these dipole-dipole data, fill-in the missing column, and create a pseudo-section. What might be going on in this example?
D. Ugolini, Joint APS-AAPT Meeting at UT-Arlington, October 2006 Developing a Capacitive Probe for Measuring Charging Effects on In-Vacuum Optics Dennis.
Electrostatics #5 Capacitance. Capacitance I. Define capacitance and a capacitor: Capacitance is defined as the ability of an object to store charge.
Investigation of effects associated with electrical charging of fused silica test mass V. Mitrofanov, L. Prokhorov, K. Tokmakov Moscow State University.
The study of electric charges in motion Electric Current.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
UCLA IEEE NATCAR 2004 SUMMER CLASS Magnetic Sensors & Power Regulation.
Multi-Straw Prototype Detector Tension Measurements Oswaldo A. Lozoya University of Texas at El Paso.
Halliday/Resnick/Walker Fundamentals of Physics
Microphones. How Microphones Work Sound is created when a vibrating object (such as a guitar string, drum skin etc..) causes the air around it to vibrate.
BASIC INSTRUMENTS - oscilloscopes
Ch. 1.3 Voltage in Electrical Systems. Gravitational and Electrical Force Gravitational force and electrical force are two universal forces in nature.
TRIUMF laboratory studies Christopher Hearty University of British Columbia/IPP 27-Sep-2010.
Chapter 9 CAPACITOR.
Date of download: 6/2/2016 Copyright © 2016 SPIE. All rights reserved. Dye ring laser control, spectroscopic, and locking feedback system showing overlapping,
HALL EFFECT TRANSDUCERS As already explained in- Art page 562, when a conductor is kept perpendicular to the magnetic field and a direct current.
전자파 연구실 1. Fundamentals. 전자파 연구실 1.1 Frequency and time Passive circuit elements is emphasized in high speed digital design : Wires, PCB, IC- package.
Power Distribution Copyright F. Canavero, R. Fantino Licensed to HDT - High Design Technology.
MECH 373 Instrumentation and Measurements
Chapter 18 Capacitance and Potential
From: A fast high-voltage switching multiwire proportional chamber
Capacitors and Dielectrics
AC Circuits AC Current peak-to-peak and rms Capacitive Reactiance
PHYS 1444 – Section 004 Lecture #11
Two Vacuums Shopvac Bosch Dept. of Mech. Engineering 1
Precision Beam Monitors for COSY Jülich
Physics Jeopardy Electrostatics, Current electricity, and Quantum
Presentation transcript:

Trinity Charging Experiment Gregg Harry, MIT On behalf of Dennis Ugolini, Trinity LIGO-G R

First generation – area around tip too wide, collides with chopper Second generation – lots of noise without grounding ring Final version

Tuning-fork chopperRotary chopper

Probe calibration with rotary chopper Voltage on conducting sample (V) Probe output (μV) Probe output read with spectrum analyzer at chopping frequency of 500 Hz. Probe-to-sample distance is 6 mm. Bare wire probe tip has 1mm diameter. A dollop of solder was added to the tip to broaden its surface to 3.25mm diameter, resulting in an improvement in sensitivity. Uncertainty in each measurement = 0.5 μV, due to fluctuation in signal.

S = charge per unit area V = voltage at meter = 1500 V L = distance to sample = 2.5 cm D = width of sample = 2.5 cm Probe with tuning-fork chopper could not see conducting sample, due to noise peak from current coil on chopper. Instead, the voltage from a conducting sample was measured with a surface DC voltmeter. We found 1500V on meter at 2.5cm from sample corresponded to 1 mV at probe, with an uncertainty of 0.01 mV. = 2.6 × C/m 2 = 1.6 × 10 9 e/cm 2 Since the uncertainty is 100 times smaller than the signal, the limit to our sensitivity is thus 1.6 × 10 7 e/cm 2. Based on the signal strength and uncertainty measured on the previous page, we find the rotary chopper probe sensitivity to be 8 × 10 5 e/cm 2.

Upper left – charge decay from insulating sample measured by rotary chopper probe, fit with an exponential. The data comes from three consecutive days with roughly equivalent weather. Upper right – semilog plot of same data, showing logarithmic decay shape. Lower left – same data displayed as 1/signal, fit to quadratic in time; in other words, S = 1/(at 2 +bt+c)

Rotary chopper probe with conducting sample at 15V. The probe signal shows an inverse- square relationship with sample distance. Noise (signal that persists when the sample voltage is reduced to 0V) increases rapidly at separations below 4mm.

Rotary chopper response for different chopping frequencies. Note that the probe output has been passed through a x100 low-noise amplifier; we have corrected for the amp’s frequency dependence. I’m not sure of the reason for this behavior, but it does make sense that as we approach DC, our sensitivity should disappear, since at that point we are not modulating the capacitance anymore.

We want to use the tuning-fork chopper because it is vacuum- compatible. But what to do about the noise peak at the signal frequency? We discovered that we could measure a nearly noise-free signal at twice the chopping frequency. The reason is that we have a 50% duty cycle chopper. During the “closed” part of the cycle, the chopper blades overlap, and electric field lines can pass outside of the blades to our probe element. We used the optical setup shown below to verify this effect. The beam is broadened to be slightly wider than the chopper blades. = field lines HeNe laser Chopper Photodiode

The tuning-fork chopper probe can clearly see the conducting sample when read at 1008 Hz. The signal size is 60% of what we found for the rotary chopper, but the uncertainty (fluctuation in the signal over time) is ~0.1 μV. This corresponds to a sensitivity of 2.7 × 10 5 e/cm 2, or about sixty times more sensitive than when read at 504 Hz. The hope is that the signal fluctuation is due to interaction with the air between the probe and sample, and that in vacuum the probe will be even more precise.

Bottom View Side View 4 in 0.5 in 0.25 in 1/8 in 0.25 in 1/16 in diam.1/4 in diam. unthreaded The new, much smaller vacuum-compatible probe. It is entirely aluminum, with 22 AWG Kapton- insulated wire held with vacuum-safe epoxy. The entire probe body is now the grounding ring.

Vacuum System Turbomolecular drag pump Dry diaphragm backing pump Gate valve Vent valve Viewport and interior access The pumps and chamber are on the same table just for the purposes of photography; they will be on separate tables, with a suspended 24” steel-braided hose connecting them, to reduce vibration in the chamber. I expect to be pumping down by the end of the meeting.

Photodiode signal from optical setup Amplified capacitive probe output with charged insulating sample Blades openBlades closed Well, they don’t look the same. But the probe trace (right) looks very much like the derivative of the optical trace (left). Perhaps this is what we should expect, since we are measuring an induced voltage causing charge to flow to and from the probe tip. It might also explain why our sensitivity degrades at low frequencies – the derivative of a slow change is a small signal. Anyway, this is all guesswork. The important thing is that while we have a fluctuating 0.1 mV noise peak at the chopping frequency of 504 Hz, the noise peak at 1008 Hz is < 4 μV, while the signal is still large.