Real-time Parity Feedback John Hansknecht & Riad Suleiman April 28, 2009.

Slides:



Advertisements
Similar presentations
Antonin Vacheret DAPNIA/SPhN, CEA Saclay.HAPPEX II Jlab Hall A Electron detectors for HAPPEX2 and He Installation in HRS Linearity tests 4.
Advertisements

Source Outlook High polarization strained-layer photocathodes were activated in both electron guns during the summer shutdown, with usual QE (0.2% at 850.
Lumi Analysis for HAPPEx III / PREX Presented by: Luis Mercado UMass - Amherst 5/18/2007.
Analog-to-Digital Converter (ADC) And
McGraw-Hill©The McGraw-Hill Companies, Inc., 2000 DATA AND SIGNALS T.Najah Al_Subaie Kingdom of Saudi Arabia Prince Norah bint Abdul Rahman University.
Parity Quality Beam (PQB) April 07, Notes: 1.For each BPM, the wires are: +X+, +X-, +Y+, +Y- 2.There are only two injector BPMs we are not reading:
Chi-Cheng Lin, Winona State University CS412 Introduction to Computer Networking & Telecommunication Theoretical Basis of Data Communication.
G 0 PC Installation and Beam Studies June & July 2006 Stephanie Bailey Riad Suleiman.
CFT Calibration Calibration Workshop Calibration Requirements Calibration Scheme Online Calibration databases.
SIMS-201 Audio Digitization. 2  Overview Chapter 12 Digital Audio Digitization of Audio Samples Quantization Reconstruction Quantization error.
Hall A Beam Current Monitors (J.G. for Sasha, Roman and Vadym)
Electronic Cross-talk & Ground Loop Elimination in Injector Riad Suleiman Center for Injectors and Sources.
JLab Polarized Source Happex Collaboration Meeting May 18, 2007 P. Adderley, J. Brittian, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
3.1 Figure 3.16 Two digital signals: one with two signal levels and the other with four signal levels.
Polarized Source Development Run Results Riad Suleiman Injector Group November 18, 2008.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
5A BOARD TESTS TALITHA BROMWICH Friday, 20 March Talitha Bromwich, FONT Group Meeting DIG IN THRESHOLDS ADC LEVELS FROM STARTUP GENERAL INPUT/OUTPUT.
Parity Quality Beam (PQB) Study Injector Group November 10, 2008.
Hall A Parity Workshop (May 10, 2002), 1 Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson.
Collimator June 1-19, 2015HUGS The collimator is placed about 85 cm from the target and intercepts scattered electrons from 0.78° to 3.8° Water cooled.
The Physical Layer Lowest layer in Network Hierarchy. Physical transmission of data. –Various flavors Copper wire, fiber optic, etc... –Physical limits.
FADC progress in Vienna Reported by H.Ishino for Vienna FADC group M.Pernicka and H.Steininger.
Short Tutorial on Causes of Position Differences… …and what we can do about them (most slides stolen from Cates PAVI ’04 talk)
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
Polarized Injector Status QWeak Collaboration Meeting February 1, 2010 P. Adderley, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman, R. Suleiman,
Fast Helicity Reversal Riad Suleiman Injector Group June 2, 2009.
5 MeV Mott Polarimeter Progress Riad Suleiman April 10, 2012.
Lecture 3 Applications of TDM ( T & E Lines ) & Statistical TDM.
MOLLER DAQ Aug 2015 meeting Team : R. Michaels, P. M. King, M. Gericke, K. Kumar R. Michaels, MOLLER Meeting, Aug, 2015.
Parity Quality Beam (PQB) Study Injector Group September 2008.
Collimator BPM electronics – Results from the lab, SPS and LHC
IT-101 Section 001 Lecture #9 Introduction to Information Technology.
Compton polarimetry for EIC. Outline Polarized electron beam Compton process Compton polarimeters at Jefferson Laboratory – Parity experiments at Jlab.
HAPPEX DAQ / ADC Tests Luis Mercado UMASS 4/17/09.
1 Electronics Status Trigger and DAQ run successfully in RUN2006 for the first time Trigger communication to DRS boards via trigger bus Trigger firmware.
Helicity Magnets Commissioning February 7, 2007 Hari Areti, Chao, Brad Cumbia, Jeff Dale, Richard Dickson, Joe Grames, Roger Flood, Scott Higgins, Matt.
Re-designing the Helicity Board Riad Suleiman Injector Group March 19, 2009.
Injector Status & Commissioning QWeak Collaboration Meeting May 24, 2010 P. Adderley, J. Clark, S. Covert, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
Chapter 3 TRANSMISSION IMPAIRMENT. 3-4 TRANSMISSION IMPAIRMENT Signals travel through transmission media, which are not perfect. The imperfection causes.
Parity Experiments and JLab Injector Riad Suleiman February 5, 2016.
LUIS MERCADO UMASS 7/10/09 HAPPEX DAQ / 18-bit ADCs.
Analog-Digital Conversion. Other types of ADC i. Dual Slope ADCs use a capacitor connected to a reference voltage. the capacitor voltage starts at zero.
Continuous Electron Beam Accelerator Facility Polarized e-Source - Talking Points for PV experiments: P. Adderley, M. BastaniNejad, J. Clark, S. Covert,
Parity Quality Beam (PQB) B-Team Meeting September 10, 2008.
Polarized Injector & Upgrade Schedule QWeak Collaboration Meeting November 06, 2009 P. Adderley, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
Polarized Injector Update
Why we need an improved LASER calibration system
Computer Data Communication
Parity Violation Experiments & Beam Requirements
Marcin Chrząszcz Cracow University of Technology Itamar Levy
Digital Communication
Data Acquisition (DAQ) Status
A Mini-Primer for Parity Quality Beam (as seen from the Accelerator)
Instrumentation for Colliding Beam Physics 2017
Parity Violation Experiments at JLEIC
Parity Quality Beam (PQB)
Accelerator Issues Raised in Hall A Parity Collaboration Meeting, April B-Team Meeting April 29, 2009.
Thoughts on why G0 needed position feedback and HAPPEX didn't
QWeak Collaboration Meeting
G0 PC Installation and Beam Studies
Qweak Coordination Meeting
Polarized Source Development Run Results
Feedback Systems Joe Grames Hall A Parity Meeting Jefferson Lab
Helicity Magnets’ Control Upgrade
PQB Meeting March 05, 2009.
Beam Position Noise from 500 keV MBO0I06 Dipole Sensor
G0 PC Installation and Beam Studies
RPC Configuration DataBase Pierluigi Paolucci - I.N.F.N. of Naples.
B-Team Meeting October 28, 2009
Injector Commissioning & Optimization
Presentation transcript:

Real-time Parity Feedback John Hansknecht & Riad Suleiman April 28, 2009

Charge Asymmetry Requirements ExperimentAverage Charge Asymmetry Ā ± Ā stat RMS (30 Hz) Quartet Time (hours) Parity Asymmetry HAPPEX & G0 (Achieved) 0.2 ± 0.2 ppm PREx0.10 ± 0.01 ppm350 ppm ± ppm QWeak0.10 ± 0.01 ppm300 ppm ± ppm I.For each helicity window, detector signal is normalized to charge II.Detector non-linearity determines the spec on the Average Charge Asymmetry III.Correction to Parity Asymmetry must be very small,

1.The Charge Asymmetry is caused by, 2.Without Charge Feedback, Charge Asymmetry will not converge to zero, and statistical error will be (N: Number of quartets), Charge Asymmetry

1.Use either Pockels Cell (PITA) or Intensity Attenuator (IA) 2.Start … after 120 seconds, measure Mean Charge Asymmetry (Ā 1 ) and calculate its statistical error, Charge Feedback 30 Hz, 500 us 120 Seconds

3.Calculate new voltage for PITA or IA, 4.Write to PITA or IA voltage set-point via EPICS There is time lag with EPICS + Network; and depends on network traffic 5.Repeat … n times … 6.Once there is drift or sudden change (i.e., the other Hall wants beam off) … start all over again …

1.Averaging over n,  Charge asymmetry is dominated by Ā 1 and converges to zero like 1/n  Statistical error scales like 1/n rather than 2.Now, error on Charge Asymmetry (assume things are stable for 1 hour, n=30), 1/n Scaling

1.At 1 kHz, we can do Charge Feedback 10 times faster (n=300), a factor of 3 improvement 2.60 Hz line noise increases width of Charge Asymmetry after apertures (A1, A2, and Slit) and must be fixed 3.Need faster way to communicate with PITA or IA … Real-time Feedback Improvements 1 kHz, 60 µs 12 seconds

1.Include all data in order to calculate Charge Asymmetry as precisely possible. Also, Feedback may not account for sudden jumps, but these jumps will show up in data off-line. 2.The Feedback will converge to an average that is different from real average of data off-line. If τ is the ratio of time it takes to apply new voltage over time of each average, Averaging over n, Why Real-time Feedback?

How Fast is EPICS? EPICS MethodExperimentTime Lag caput IGLdac2:G2Ch3Pos 5.0 caput IGLdac2:G2Ch4Neg 5.0 HAPPEx100’s ms to 1 s ECA::ChannelAccess ca ca.Channel("IGLdac3:ao_4", 5.0) ca.PutOnce() G010’s ms ECA::ChannelAccess ca ca.Channel("IGLdac3:ao_4", 5.0) ca.Connect() { // It only needs to set value since it was already connected ca.Put()} New< 1 ms

New Requirements

I.HAPPEx III, PVDIS, and PREx will use PITA Feedback while QWeak will use IA Feedback II.16-bit DAC for voltage output: o PITA Voltage: 0-10 DACV (actual: -300 – +300 V, on top of 2500 V) Slope usually around 600 ppm/DACV 1 bit = V → ppm step size o IA Voltage: 0-10 DACV (actual: -45 – +45 V) Slope usually around 300 ppm/DACV 1 bit = V → ppm step size III.16-bit ADC for voltage readback IV.Channels: I.Pockels Cell +HV and –HV II.Hall A IA: four voltage set-points, one for each helicity pattern III.Hall C IA: four voltage set-points, one for each helicity pattern PITA and IA Voltage I/O (Hansknecht, ready by Aug 1 st, 2009)

Past parity experiments: 1.Collected 2 minutes of data to measure Charge Asymmetry 2.Calculated new PITA or IA set voltage 3.Sent it through EPICS using Method I or Method II Future parity experiments: I.HAPPEx III, PVDIS, & PREx will use fast EPICS: 1.Collect few seconds of data to measure Charge Asymmetry 2.Calculate new PITA set voltage 3.Send it through EPICS using Method III II.QWeak will decide on fast EPICS by December 2009, otherwise use dedicated fibers: 1.Collect few seconds of data to measure Charge Asymmetry in Parity DAQ VME crate in Counting House 2.Calculate new IA set voltage 3.Send digital value to DAC on Laser Table via high speed digital/analog fiber optic link Charge Feedback Schemes