Energy Analysis Department Coal-Wind Hybrid: Assumptions & Findings Coal-Wind Hybrid: Assumptions & Findings Amol Phadke, Ph.D. Lawrence Berkeley National.

Slides:



Advertisements
Similar presentations
Carbon Dioxide Emissions Costs and Electricity Resource Planning New Mexico Public Regulation Commission Case No UT March 28, 2007 Presented.
Advertisements

Hawaii: 2020 Presented by Alex Waegel for Team Cake B.
Will CO2 Change What We Do?
1 © 2008 Electric Power Research Institute, Inc. All rights reserved. The Power to Reduce CO 2 Emissions The Full Portfolio Energy Technology Assessment.
Toward BECCS Market Launch via Biomass/Fossil Fuel Coprocessing to Make Synfuels in CO 2 EOR Applications Robert H. Williams Princeton Environmental Institute.
Financial Model.
Technical Conference Avoided Cost Modeling January 6, 2015.
Meeting with Rep. _______________ Solar Industry Representatives May 5, 2010.
Toward a Sustainable Future Name of Conference, Event, or Audience Date Presenter’s Name | ©2011 Synapse Energy Economics Inc. All.
Northwest Power and Conservation Council Effects of Alternative Scenarios on Sixth Power Plan Northwest Power and Conservation Council Whitefish, MT June.
Director of Technology Development, Emerging Technology Department
IPCC Synthesis Report Part IV Costs of mitigation measures Jayant Sathaye.
Study Case Report PC 10 High Carbon Price PC 11 Low Carbon Price W ESTERN E LECTRICITY C OORDINATING C OUNCIL.
Energy, Society, and the Environment Unit 3 Energy Economics.
ERCOT PUBLIC 4/22/2014 Updates for 2014 LTSA Scenario and Data Assumptions 4/22/2014.
ERCOT PUBLIC 3/25/ LTSA Scenario and Data Assumptions March 25, 2014.
Financing model for power plants with CCS Carbon Capture and Storage: Perspectives for the Southern Africa Region Johannesburg May 31-June 1, 2011 Nataliya.
Economic Analyses of FPL’s New Nuclear Projects: An Overview Dr. Steven Sim Senior Manager, Resource Assessment & Planning Florida Power & Light Company.
CHEAPER AND CLEANER: Using the Clean Air Act to Sharply Reduce Carbon Pollution from Existing Power Plants, Delivering Health, Environmental and Economic.
0 Rocky Mountain Institute 0 A New Dawn: Breakthrough Growth Strategies for Wind Kyle Datta, Senior Director Rocky Mountain Institute.
Climate Change: An Opportunity for a Bi-Lateral Approach Driving Technology Innovation Woodrow Wilson International Center for Scholars Canada Institute.
National Renewable Energy Laboratory Innovation for Our Energy Future * NREL July 5, 2011 Tradeoffs and Synergies between CSP and PV at High Grid Penetration.
Energy Business Solutions Michigan IRP Working Group Meeting June 10, 2005.
WORKSHOP ON TECHNOLOGY PATHWAYS FORWARD FOR CARBON CAPTURE & STORAGE ON NATURAL GAS POWER SYSTEMS April 22, 2014 Revis W. James Director, Generation R&D.
The Economics of Marine Renewable Energy Peter McGregor Fraser of Allander Institute, Department of Economics, University of Strathclyde Second Forum on.
Business Sensitive Big Sandy 1 FGD Analysis February 2006 DRAFT Strategic Policy Analysis Portfolio Management Analysis Advanced Environmental Technology.
Draft Avoided Cost Forecast and Marginal CO 2 Offset Value of Conservation Regional Technical Forum Maury Galbraith Northwest Power and Conservation Council.
KEC Electricity Committee, March 12, 2008 Benefit Cost Study of the Governor’s 2015 Wind Challenge: 1,000 MW by 2015 Bob Glass KCC Utilities Division,
Northwest Power and Conservation Council Slide 1 The Role of Efficiency In Meeting PNW Energy Needs Tom Eckman Manager, Conservation Resources Northwest.
Northwest Power and Conservation Council Slide 1 Direct Use of Natural Gas Economic Fuel Choices from the Regional Power System and Consumer’s Perspective.
Highlights of AESC 2011 Report Vermont Presentation August 22, | ©2011 Synapse Energy Economics Inc. All rights reserved.
Jenell Katheiser Doug Murray Long Term Study Scenarios and Generation Expansion Update January 22, 2013.
Wind Energy Update Larry Flowers National Renewable Energy Laboratory November 30, 2007 Salt Lake City, UT.
ENVIRONMENTAL IMPACT AND ENERGY PRODUCTION: EVALUATION OF BIOCHAR APPLICATION ON TAIWANESE SET-ASIDE LAND Chih-Chun Kung November 2012 Austin, Texas.
Co-Production of Hydrogen and Electricity (GHG/07/42) Hydrogen may be used in future as an energy carrier In the long term it is expected.
Preliminary Results with the Regional Portfolio Model Michael Schilmoeller for the Northwest Power and Conservation Council Generation Resource Advisory.
Clean Air Act Section 111(d) Indiana State Bar Association Utility Law Section September 4, 2014 Thomas W. Easterly, P.E., BCEE Commissioner IN Department.
Northwest Power and Conservation Council Slide 1 Accelerating Energy Efficiency To Reduce the PNW Power System's Carbon Footprint Tom Eckman Manager, Conservation.
Interaction of a GHG Emissions Cap With Energy Technologies and Markets USAEE Annual Conference – Washington DC October 11, 2011 Donald Hanson and David.
The Power to Reduce CO 2 Emissions The Full Portfolio National Association of Utility Regulatory Commissioners Winter Committee Meetings Committee on Electricity.
Kevin Hanson Doug Murray Jenell Katheiser Long Term Study Scenarios and Generation Expansion Update April, 2012.
Generation Technologies in a Carbon-constrained World Steve Specker President & CEO October 2005.
Allocation of CO 2 Emission Allowances in RGGI Dallas Burtraw, Karen Palmer, Danny Kahn Resources for the Future Presentation to RGGI Stakeholder Meeting.
Northwest Power and Conservation Council A Look At The Council’s Conservation Planning Methodology and Assumptions A Look At The Council’s Conservation.
Transition of the Generation Fleet in a Carbon-constrained World American Public Power Association October 17, 2006 Barbara Tyran Director, Washington.
Northwest Power and Conservation Council Overview of Draft Sixth Power Plan Council Meeting Whitefish, MT June 9-11, 2009.
Long Term Study Scenarios and Generation Expansion Update October 12, 2012.
Analysis of Tribal Set Aside Issues– Preliminary Summary of Results Prepared for : National Tribal Environmental Council Prepared by: ICF Consulting, December.
1 Proposed Input Assumptions to RTF Cost-Effectiveness Determinations February 2, 2010.
On/Off Operation of Carbon Capture Systems in the Dynamic Electric Grid On/Off Operation of Carbon Capture Systems in the Dynamic Electric Grid Rochelle.
Economic Assessment of Implementing the 10/20 Goals and Energy Efficiency Recommendations – Preliminary Results Prepared for : WRAP, AP2 Forum Prepared.
U.S. Energy Information Administration Independent Statistics & Analysis Outlook for coal and electricity for National Coal Council November.
October 26, 2005 ICF Consulting RGGI Electricity Sector Modeling Results RPS Sensitivity & Very High Emissions Reference and Package Cases.
Advancements in Coal Technology 2006 Mid-America Regulatory Conference Columbus Ohio Tom Hewson Energy Ventures Analysis Inc Arlington Virginia June 20.
Slide 1 Overview of Conservation in the Pacific Northwest Energy Efficiency Options in the Northwest Post-2011Meeting March 4, 2008.
ENERGY & CLIMATE ASSESSMENT TEAM National Risk Management Research Laboratory U.S. Environmental Protection Agency Office of Research.
15ELP044: Energy System Investment and Risk Management Unit 2B: Energy Economics and Markets Paul Rowley 1, Simon Watson 1 and Andy Williams 2 1 CREST.
Energy System Investment and Risk Management Unit 2: Energy Economics and Markets Connect Seminar, 3 rd March 2016, 18:30GMT.
Coal in a Carbon-Constrained World Ernest J. Moniz, Cecil and Ida Green Professor of Physics and Engineering Systems Director, MIT Energy Initiative Baker.
© OECD/IEA Do we have the technology to secure energy supply and CO 2 neutrality? Insights from Energy Technology Perspectives 2010 Copenhagen,
Clean Power Plan Insights for Pennsylvania Jeffrey Anderson, Paul Fischbeck, Haibo Zhai, David Rode Department of Engineering and Public Policy Carnegie.
Viability of Carbon Capture and Sequestration Retrofits for Existing Coal- fired Power Plants under an Emission Trading Scheme CEDM Annual Meeting May.
Forecasting Power System Hourly Load and Emissions for Air Quality Modeling ERTAC-EGU Model Development Group – Webinar & Outreach slides Robert.
04/16/ Planning New Generation APPA Operations & Engineering Conference April 10, 2006 Jay Hudson, PE Manager, Environmental Management.
Pan-Canadian Wind Integration Study (PCWIS) Prepared by: GE Energy Consulting, Vaisala , EnerNex, Electranix, Knight Piésold Olga Kucherenko.
RENEWABLES AND RELIABILITY
Generation Expansion Daniel Kirschen
New England Economic Partnership James Daly Vice President Energy Supply Energy Market Perspectives Reliable Energy, Competitive Prices and.
Discounting Future Benefits and Costs
Wholesale Electricity Costs
Presentation transcript:

Energy Analysis Department Coal-Wind Hybrid: Assumptions & Findings Coal-Wind Hybrid: Assumptions & Findings Amol Phadke, Ph.D. Lawrence Berkeley National Laboratory 9/6/2007, 2007

Energy Analysis Department Outline of the Presentation Final Assumptions Testing the economic rationale of coal-wind hybrid Results for hybrid options Competitiveness of the hybrid with other options Conclusions

Energy Analysis Department Overview of the Analysis Developed a spread-sheet based model Identified possible hybrid configurations Finalized assumptions about technical parameters and costs Evaluated costs of different options with varying assumptions Today’s objectives -Review assessment of the hybrid options

Energy Analysis Department Economic Rationale for Coal-Wind Hybrid What is Coal-Wind Hybrid project? Economic rationale Improve the utilization of transmission lines Long distance transmission costs are significant Second best option to firm-up the wind Avoid wind integration and capacity costs

Energy Analysis Department Coal Wind Hybrid from an Economic Perspective

Energy Analysis Department Key Economic Considerations Tradeoffs between generation and transmission costs - Backing down of power generation unit: Increases generation costs per unit of output and reduces transmission costs Tradeoffs between fuel production and transmission costs -Lower capacity factor of the FT reactor

Energy Analysis Department Resource Options Considered Hybrid options -Hybrid with fuels production (SNG, Syncrude, methanol) -Syngas storage (system is sized lower than the power generation unit) -CCGT-wind hybrid, CT-wind Hybrid, Hypothetical Hybrid Benchmark -All Coal-wind hybrid options have 3000 MW of coal generation, 1500 MW wind generation, 3000 MW of transmission line Competing options -Stand alone coal, stand alone wind (with capacity overbuild), NGCC, PC, solar concentric power Options not considered -Advanced gas: cost of saved CO2 ~ $80/Ton, buying permits more economical -PC + CCS: More expensive than IGCC + CCS -IGCC without CCS: without CCS, IGCC does not offer economic advantages over PC. IGCC has lower emissions of mercury and sulfur and has lower water requirements

Energy Analysis Department Assumptions about Capital Costs and Technical Parameters Current costs expressed in 2006$ NETL estimates include recent run-ups in fossil plant costs NREL estimate (reference) of wind plant costs include recent run-ups in plant costs Technological performance (expected performance of plants coming online in time horizon) -Capacity factor -Heat Rate

Energy Analysis Department Key Assumptions…I

Energy Analysis Department Fuel Prices Assumptions Natural Gas Prices -Annual energy outlook (AEO) forecast -Systematic difference between AEO & NYMEX futures ($0.78/MMBtu : Bolinger et. al) t Risk premium t Systematic bias t No convergence -NYMEX projected into future using escalation rate in AEO t Adjusted for delivery in the pacific region (by adding $.11/MMBtu) t Levelized natural gas price ( ) of $7.10/MMBtu (2006$) t Cut off ranges explored Coal Prices -Levelized price ( ) derived from AEO forecast of Wyoming Coal: $9.40/Short Ton : $0.55/ MMBtu -Cut off ranges explored

Energy Analysis Department Carbon Prices Assumptions Base Case $40/TonCO2: FEAST model assumption base case (assuming CA will meet its targets on its own: without buying offsets) Wide range of carbon prices (significantly driven by assumptions about offset prices and emission reduction target levels) Cutoff price estimated, high price scenario explored

Energy Analysis Department Key Assumptions: Transmission Feast Model Assumptions Base Case: AC + DC Transmission

Energy Analysis Department Key Assumptions, Financing

Energy Analysis Department Approach to Analyze the Economics of Fuel Production (SNG, Syncrude, Methenol) Adding a Fuel Facility -Allows a higher capacity factor for all the components in the system except the power generation unit -Lowers the capacity factor of the fuels plant Additional costs of fuel production are apportioned to the costs of power generation For example, in a Syncrude production facility -$737M required for FT which has a peak capacity of handling gas worth 1500 MW of output and 47% capacity factor -Same output can be produced by a FT which has a peak capacity to handle gas worth ~ 1500 MW, which costs $346M -Cost of FT that is paid by power generation $390M The costs of this configuration are cheaper compared to a configuration in which the entire IGCC unit is backed down to accommodate the wind output The economics of the fuels production facility is same as a stand-alone coal to liquids fuel production facility

Energy Analysis Department Additional Costs of Fuel Production Facilities

Energy Analysis Department Syngas Storage Option: Estimating Storage Requirements

Energy Analysis Department Variation in Storage Requirement Year to year and within month lower than the seasonal requirements for storage Variation in the seasonal storage requirements Storage costs assuming storage in depleted natural gas wells (cheapest option) Storage requirement 4stdev greater than the observed value

Energy Analysis Department EOR Revenue and Potential EOR revenues depend on the oil price Bilateral monopoly case EOR revenues will be shared in half: $15/MWh if EOR revenue = $30/MWh Total EOR potential in the RM region will absorb 70% of the CO2 emissions of the hybrid plant in its lifetime Average EOR revenue (adjusting for transpiration costs) $9.5/MWh Distance from different markets -For first few plants, sequestration costs will be zero

Energy Analysis Department Other key issues Ramp rate of FT is sufficient to accommodate variation in output due to wind ~ 3% reduction in the heat rate of hybrid options due to backing down of power generation unit Capacity equivalence costs are considered in scenario analysis 20% overbuilding of wind capacity results into ~ 15% increase in transmission utilization & 1.5 % reduction in wind capacity factor

Energy Analysis Department Results Comparing with other hybrid options -Wind-CCGT hybrid, wind CT Hybrid, wind-coal hybrid without fuels production -Sensitivity to fuel prices Comparing with the benchmark co-located coal-wind facility Comparing with competing options Sensitivity analysis -Transmission -Wind integration and capacity costs -EOR -Capacity equivalence costs -Fuel prices -Carbon prices -Capital costs

Energy Analysis Department Base Case Assumptions

Energy Analysis Department Comparing Hybrid Options: Coal-wind hybrid with fuel production or storage is the cheapest

Energy Analysis Department Testing the Economic Rationale of Coal-Wind Hybrid Stand alone coal, wind, and other hybrid options and are not the appropriate benchmarks, they are competing options -Total costs are influenced by generation costs in addition to transmission utilization -If stand alone wind generation is cheaper than coal, then Coal and Wind hybrid could be cheaper than coal simply because it is including wind generation Appropriate benchmark is -co-located coal-wind facility where the ratio of the coal to wind generation is the same as the hybrid system -Coal unit is operated at its full capacity factor -Enough transmission capacity to carry peak coal and 80% of the peak wind generation (since the wind capacity is overbuilt) -This hypothetical benchmark consist of ~2700 MW of coal, 1800 MWs of wind, and 4200 MWS of transmission capacity which results into a transmission utilization of 77% instead of 97% in the hybrid case -Coal generation 75%, wind generation 25%

Energy Analysis Department Costs and benefits of the coal wind hybrid option Benefits -Improved utilization of transmission t Compared to stand alone wind, stand alone coal, and the hypothetical co-located coal wind facility t Cycling leads to improved transmission utilization t An outage causes lower utilization of transmission. However, in the hybrid, the utilization of transmission is less affected by an outage. Outage is usually less than the backed down power generation in the hybrid [For an outage rate of 10%, transmission utilization is lowered by 3% instead of 10% in the stand alone coal case] -Improved utilization of the IGCC + CCS system t In the stand alone option, outage in the power generation unit requires backing down of gasifiers resulting into lower utilization of the air separation unit, gasifiers, pollution control equipment, carbon separation and capture equipment. In the hybrid, this is not the case. The output from the gasifieres can be diverted to the fuels plant -Avoided wind integration and capacity equivalence costs Costs -Lower utilization of the power generation unit -Additional costs of fuel production or syngas storage faculties

Energy Analysis Department Results: NPV of the benefits

Energy Analysis Department Comparison with competing options Base Case Sensitivity Analysis

Energy Analysis Department Results: Base Case

Energy Analysis Department Sensitivity Analysis: Conceptual Map

Energy Analysis Department Transmission Choice & Costs Wind costs affected by the transmission assumptions the most

Energy Analysis Department Effect of wind integration and capacity costs Stand alone wind more competitive if wind integration and capacity costs are negligible

Energy Analysis Department Effect of Natural Gas Prices At a price of about $5.5/MMBtu or below, CCGT is the cheapest option

Energy Analysis Department Effect of EOR Revenues: Net Carbon Costs Counting EOR makes stand alone coal the cheapest option

Energy Analysis Department Effect of Coal Prices Results are not very sensitive to coal prices

Energy Analysis Department Effect of Carbon Prices ~ $16/TonC02 or below, PC becomes the most attractive option

Energy Analysis Department Scenario where advanced coal and hybrid options are not cost competitive Low NG ($5/MMBty) and low Carbon ($20/MMBtu) Price

Energy Analysis Department Effect of Increase/Decrease in Capital Costs of Generation Technologies CCGT costs least affected

Energy Analysis Department Conclusions Coal-wind hybrid with fuel production or syngas storage is most economical among other hybrid alternatives (CCGT-wind hybrid, CT-wind Hybrid, and coal-wind hybrid without fuel production or storage) Coal-wind hybrid has economic merit and compared to a stand alone benchmark, savings range from ~ $300 M to $1500 Mover the life of the project Coal-wind hybrid is competitive with or more economical compared to -NGCC generation above a NG price $5.5/MMBtu (at a carbon price of $40/TonCO2) -PC generation above a carbon price of $16/TonCO2 -It is more economical than PC and NGCC based on prevailing expectations of the cost of generation technologies and fuel prices Stand-alone wind generation is more economical than NGCC generation in most scenarios Results are screening level: future work required for precise estimates

Energy Analysis Department Next steps Emission footprint Finalize first draft of the report Incorporate any suggested changes Comparison of qualitative advantages of different hybrid options