Status of scintillator KLM study P. Pakhlov (ITEP)

Slides:



Advertisements
Similar presentations
Development of scintillation detectors with MRS APD light readout for CBM Muon system and ECAL preshower Alexander Akindinov ITEP(Moscow) on behalf of.
Advertisements

1 Construction of the hadronic calorimeter prototype for ILC (CALICE collaboration) or experience with Geiger mode operating multipixel photodiodes (SiPM)
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
Microscope Performance at elevated dark rates Richard Jones University of Connecticut collaboration GlueX collaboration meeting, Newport News, Feb. 2-4,
Scintillator based muon upgrade / BELLE Super B Factory Workshop In Hawaii Jan 2004, Honolulu, Hawaii 1.Scintillator strip option 2.Geiger photodiodes.
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
Reports from DESY Satoru Uozumi (Staying at DESY during Nov 11 – 25) Nov-21 GLDCAL Japan-Korea meeting.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Photo-detector and scintillator studies at ITEP Outline 1. Check of casting form 2. Study of MRS APD’s from CPTA 3. MC simulation of light collection in.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
SiPM: Development and Applications
Scintillator strip KLM detector (progress report) P. Pakhlov for ITEP group.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
KLM summary P. Pakhlov (ITEP) Status of Geant4 simulation of scintillator KLM Status of Geant4 simulation of scintillator KLM by Gallina PAKHLOVA (ITEP)
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Scintillator strip KLM detector for Super Belle P.Pakhlov for ITEP group.
Scintillator Tiles and Test Beam Plans Calice Collaboration Meeting – Casablanca 2010 Christian Soldner Max-Planck-Institute for Physics.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Scintillating Tiles for the Muon Inner regions LHCb Muon Upgrade meeting, CERN May Wander Baldini for the Ferrara LHCb group.
KLM detector for SuperB P. Pakhlov (ITEP) 1 st Open meeting of the SuperKEKB Collaboration.
Mass production and mechanical structure P. Pakhlov (ITEP)
KLM detector for SuperB P. Pakhlov (ITEP) 1 st Open meeting of the SuperKEKB Collaboration.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
SPIROC update Felix Sefkow Most slides from Ludovic Raux HCAL main meeting April 18, 2007.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
F Don Lincoln, Fermilab f Fermilab/Boeing Test Results for HiSTE-VI Don Lincoln Fermi National Accelerator Laboratory.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Scintillator strip KLM detector for Super Belle P. Pakhlov for ITEP group Outline: Motivation for new detector Proposed setup Geiger APD as photodetector.
Super-IFR Detector R&D summary Wander Baldini Ferrara, Padova, Roma1 INFN and University on behalf of the superB-IFR group: Ferrara, Padova, Roma1 INFN.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Peter Križan, Ljubljana September 17, 2008 SuperB PID Peter Križan University of Ljubljana and J. Stefan Institute Forward PID: - SiPM as photon detectors.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
SuperB workshop SLAC, October 6, Outline Present Design Some thoughts about tile production Updated cost estimate Light yield studies of 3 mm thick.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
IFR Detector R&D status
Fabio, Francesco, Francesco and Nicola INFN and University Bari
WBS 1.03 Readout Systems Specifications, Design and Acceptance
Light mixer proposal Arjan Heering, Anton Karneyeu
Roman Mizuk (ITEP, Moscow)
Prototype activities update
ITEP&MEPhI status report on tile production and R&D activities
Scintillator tile- SiPM systems R&D
R&D of MPPC for T2K experiment
Comparison of CPTA and Hamamatsu SiPMs
Testbeam analysis on module #1
P. Pakhlov (for D.Liventsev)
R&D of MPPC in kyoto M.taguchi.
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Status of scintillator KLM study P. Pakhlov (ITEP)

Scintillator KLM end cap detector RPC frame Key issues: reliability, radiation hardness Scintillator detector with WLS fiber readout is a well established technique for particle detection: stable; fast; radiation hard; cheap Drawback: it is more sensititive to neutrons due to hydrogen. Tests in the KEKB tunnel demonstrated that neutron bg rate at scintilator is 5-7 times larger than at RPC. Independent x-y operation and good time resolution (coincidence gate can be as small as 10ns) allow to suppress bg even higher than RPC Photosensor (one per strip) = Si photo diode in Geiger mode (SiPM): fast, efficienct to green light, high gain, compact, operable in B-fields, relatively cheap

SiPM radiation hardness sufficient for sBelle? Neutron irradiation results in defects in the sensitive region. Defects are sources for extra noise.  Large number of independent pixels + short recovery time allow to keep the signal efficiency high even with the 1 p.e. noise rate ~ few tens MHz.  The expected neutron flux around the proposed SiPM position at SuperB is n/cm 2 (measured by luxel dosimeters and independently calculated from ECL’s APD damage)  Many groups (ITEP, Calice, T2K, etc) measured the radiation damage effect noise 10 pe signal noise after n/cm 2 irradiation toy MC t, nsec Initial 1 p.e. noise: 0.5 MHz – MPPC (Hamamatsu) 1.5 MHz – MRSAPD (CPTA) 1 p.e. noise after irradiation with n/cm 2 : 7 MHz – MPPC (Hamamatsu) 12 MHz – MRSAPD (CPTA) The signal efficiency should be unchanged after 5 years of SuperBelle operation at 2 * or even 5 * However, the neutron spectrum at Belle/sBelle is unknown + conversion dose  neutron flux is not reliable. Direct measurement of the damage in the real conditions is required

SiPM radiation hardness tests in the KEKB tunnel Both MRSAPD and MPPC are ok for SuperB Both Russian MRSAPD and Hamamtsu MPPC have been exposed in KEKB tunnel near beam during 50 days (> 1Sv = ⅓ of the 5 year SuperB dose):  one photoelectron noise increased – seen in the random trigger data.  Pedestal and p.e. peaks are smeared – seen in the LED data.  But the signal from MIP (~ 25p.e. ) is not changed. MIP trigger 6 p.e. threshold before irradiaiton after irradiaiton random trigger LED trigger MPPC The measured neutron dose at the proposed SiPM position now (L=1.4×10 34 ) ~ 1mSv/week  15mSv/week at SuperB (L=2×10 35 )  3Sv/5 years The similar MIP efficiency immunity to neutron damage is seen with MRSAPD (CPTA), however the pe peaks are poorly resolved (due to longer recovery time)

Callibration and monitoring after irradiation Unlike our previous statement that amplitude measurement are not necessary for scKLM, we now believe that this is one of important point to keep stable operation Amplitude  Np.e. conversion requires callibration and monitoring of 1 p.e gain. This is useful for HV and threshold ajustment during the whole running period.  Internal noise + physics backgrounds can be used for on-line SiPM callibration (or during local run). It is sufficient to measure noise/bg rate vs threshold: The distance between plateus corresponds to 1 p.e. (red line) threshold rate log scale  After few years of running due to increased noise the amplitude is smeared by overlapped noise pulses: difficult to see plateus in rate vs threshold distribution (blue line). Loose possibilities of callibration?  The correction on overlapping possible using Gary’s read out electronics: 1GHz ADC measurement + FPGA to fit ~10 points 1 pe

cv D1.2 Strips from two producers are tested and compared in ITEP Fermilab (USA) (used in T2K near detector) D1.2 mirror The same outer strip geometry, but different geometry of groove We are now not able to provide comparison of the scintillator plastic quality for Kharkov – Fermilab strips. This should be done by TDR (September 09). (in any case, both are ok for SuperB: sufficient light collection from the 3-meter far end) The central groove (Fermilab) is slightly more preferable (~10% better light collection); glueing is easier Kharkov can not produce central groove. However, if the fiber glueing is done in ITEP, transportation/tax is too costly from Fermilab. TEST of the groove geometry: Kharkov (Ukraine) (used in OPERA)

Summary = to do list for TDR Comparison of design with MRSAPD (CPTA) & MPPC (Hamamtsu)  Both are ok, however application of either requires to solve some technical problems.  Elaborate details of using for both: mounting, HV supply, control and callibration, maintanance, cost.  Compare and find optimal solution. Comparison of design with Kharkov and Fermilab scintillator strips  Both are ok.  Need to compare scintillator quality first end elaborate the manufacuring (fiber glueing) procedure.  Compare resulting quality and cost to find optimal solution. Full Geant MC study (standalone MC for KLM encap is done already) to confirm/study physics performance. Electronics:  Gary’s electronics seems to be optimal for our purposes. The features that seemed to be excessive are very welcomed now.  Need to check that it is possible to work without preamplifier  Ajustable HV supply still need to be elaborated