Bonding and Grounding What? Why? How?

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

Grounding Electrodes.
The Electrical GuruTM Paul W. Abernathy,CME
Presentation : IMS – Tech Managers ConferenceAuthor : IMS StaffCreation date : 08 March 2012Classification : D3Conservation :Page : # 05 - Wiring Methods.
Electrical Installation
Earthing PRESENTATION BY: Er. Satnam Singh Lecturer(Electrical engg.)
imnot50 and suite4121 The form of protection provided by the insulation of live parts would be: Protection against direct contact.
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
Stray Current Investigations A Method of Troubleshooting Stray Current on Underground Residential Distribution (URD) Loops Stacey Mighty Malcolm Distribution.
Telecom Cabling Grounding and bonding.
EE4503 Electrical Systems Design
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
Guide to Network Cabling Fundamentals
EET Survey of Electronics
Electrical Power Systems
INTRODUCTION TO T&T ELECTRICAL WIRING CODE TTS 171: PART 1: 2002
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
Circuits 6-1.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Sub Part K Electrical - Installation Safety Requirements (a) Covered. Sections through contain installation safety requirements for.
Area of Study 2: Electricity
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Electrical Installation 2
Technological World. Electrical Function An electrical function is the role that a component plays in the control or transformation of electric current.
Grounding, bonding, and ground fault currents
Roadway Lighting on TxDOT Right of Way Greg Jones, EIT Master Electrician, State of Texas TxDOT, Traffic Operations Division, Illumination Branch.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Gandhinagar Institute of Technology
©Ted “Smitty” Smith This speed drill focuses on subjects that will be required for the journeyman and masters examination arranged by chapter of.
GROUND FIELD RESISTANCE TESTING COMPLYING WITH MSHA REGULATIONS.
Ag. Mechanics for Beginning Teachers
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 21- Residential Improving your skill in code Look Up Increasing Speed Drill.
Electrical Safety Authority
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
ELECTRICAL INSTRUMENTS ( service and utilization )
Unit 231 Grounding Bonding Overcurrent Protection.
Chapter 4 Electrical Systems and Protection Chapter 4 Electrical Systems and Protection.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Grounding the Electrical System
PROTECTION AGAINST INDIRECT CONTACT
Circuits.
Grounding And Safety Techniques Ms. Tahoora Qureshi, Asst. Professor
Basic Electrical Safety
Smitty’s Two Minute Drills
Grounding the Electrical System
EARTHING.
POWER QUALITY AND MANAGEMENT. TITLE : EARTH GROUND GRID SYSTEM AND POWER GROUND SYSTEM. PREPARED BY : JOBIN ABRAHAM.
Hazardous Areas & Hazards of Electricity
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Engineering Project Cable Management.
Govt. Polytechnic,Manesar
Overcurrent Protection— Fuses and Circuit Breakers
EET 323 – Electrical System Design Lecture 9: Grounding
Safety Meeting Topics Standby Generator Safety
Basic Electrical Safety
Smitty’s Two Minute Drill Grounding and Bonding
A. Touching both terminals with the hands can cause electrical shock
Basic Electric Principles
Electrical components and systems
Difference between Earthing & Grounding
Grounding Myths.
Presentation transcript:

Bonding and Grounding What? Why? How? Ark Tsisserev, FEC, M.Sc., P.Eng. Principal IEEE, Alberta section, September, 2013

Object of bonding and grounding Sections 10 and 36 of the CE Code

Definitions Bonding - a low impedance path obtained by permanently joining all non-current carrying metal parts to ensure electrical continuity and having the capacity to conduct safely any current likely to be imposed on it. Bonding conductor - a conductor that connect the non-current-carrying parts of electrical equipment, raceways, or enclosures to the service equipment or system grounding conductor. Ground fault circuit interrupter (GFCI) – a device whose function is to interrupt, within a predetermined time, the electrical circuit to the load when a current to ground exceeds a predetermined value that is less than that required to operate the overcurrent protective device of a supply circuit.

Definitions Ground fault protection – a device, other than a ground fault circuit interrupter of the Class A type, whose function is to control or interrupt ground fault current or voltage-to-ground in the circuit or system where it is installed. Grounded – connected effectively with the general mass of the earth through a grounding path of sufficiently low impedance and having an ampacity sufficient at all times, under the most severe conditions liable to arise in practice, to prevent any current in the grounding conductor from causing a harmful voltage to exist. Between the grounding conductors and neighbouring exposed conducting surfaces that are in good contact with the earth or; Between the grounding conductors and neighbouring surfaces of the earth itself.

Definitions Grounding – a permanent and continuous conductive path to the earth with sufficient ampacity to carry any fault current liable to be imposed on it, and of a sufficiently low impedance to limit the voltage rise above ground and to facilitate the operation of the protective devices in the circuit. Grounding conductor – the conductor used to connect the service equipment or system to the grounding electrode. Grounding electrode – a buried metal water-piping system or metal object or device buried in, or driven into, the ground to which a grounding conductor is electrically and mechanically connected.

Definitions Grounding system – all conductors, clamps, ground clips, ground plates or pipes, and ground electrodes by means of which the electrical installation is grounded.

Grounding and Bonding 10-000 Scope This Section covers the protection of electrical installations by grounding and bounding. Insulating, isolating and guarding may be used as means of affording supplemental protection to grounding or, where permitted, in the Code, as a suitable alternative.

Grounding and Bonding 10-002 Object Grounding and bonding as required by this Code shall be done in such a manner as to serve the following purposes: To protect life from the danger of electric shock and property from damage by boding to ground non-current-carrying metal systems; To limit the voltage on a circuit when it is exposed to higher voltages than that for which it is designed; In general to limit as circuit voltages-to-ground to 150 V or less on circuits supplying interior wiring systems; To facilitate the operation of electrical apparatus and systems; and To limit the voltage on a circuit that might otherwise occur through exposure to lighting.

System and Circuit Grounding

System and Circuit Grounding

System and Circuit Grounding

System and Circuit Grounding

Single-phase, 3-wire solidly grounded system (midpoint grounded)

Three-phase, 4-wire solidly grounded system (midpoint grounded)

Three-phase, 4-wire solidly grounded system with no neutral load (3-wire on load side) (midpoint grounded)

Three-phase, 4-wire impedance grounded system (midpoint grounded)

Rule 10-206

Different three-phase, 4-wire solidly grounded systems at a facility (midpoint grounded)

Three-phase, 3-wire ungrounded (delta) system

Grounding electrodes

Grounding electrodes

Grounding electrodes

Grounding electrodes

Rules 10-700(1)(a), 10-700(4) Manufactured grounding electrodes are those manufactured and certified to CSA C22.2 No. 41. It is important that in-situ grounding electrodes provide an equivalent surface area contact with earth so as do manufactured electrodes (see CSA C22.2 No. 41). Consideration should also be given to the effects that corrosion may have on the in-situ ground electrode impacting durability and life-expectancy. For example, an underground metal water piping system located at least 600 mm below finished grade and extending at least 3 m has traditionally been recognized as a suitable grounding electrode. Similarly, the metallic reinforcement of a concrete slab, concrete piling, or concrete foundation and iron pilings in significant contract with earth at 600 mm or more below finished grade have also been found to be suitable in-situ electrodes.

Rules 10-700(1)(a), 10-700(4) Any metallic material encapsulated with a non-conductive compound to protect it from corrosion would not meet the criteria for use as an in-situ ground electrode.

Grounding and Bonding

Grounding and Bonding

Grounding and Bonding

Grounding and Bonding

36-304 Station ground resistance

36-304 Station ground resistance

Grounding inside and outside equipment to remote grounding grid electrode

Grounding of pad-mounted transformer

Grounding of gang-operated switch handle

Notes: (1) 3 pole switching arrangement conforming to Rules 6 – 106 and 14-612 might work with MDGF installed in breakers G1; M1 and M2. Such approach will meet provisions of Rule 14-102 (see diagram 3 in the CEC). (2) Grounding electrodes of all three solidly grounded systems (derived by each transformer – TX5; TX6 and by 2 MW generator) could be interconnected at a common tie point at the service equipment. Re: Rule 10-206 (2). (3) Grounded service conductor from each such source (G-Generator: TX5; TX6) is allowed to carry unbalanced current (to function as neutral), and to carry fault current (to function as bonding conductor). Re: Rules 10-204 (2) (a) – (c); 10-624 (2).