ADVANCED BIO-FRIENDLY POLYMERS Igor Lacík Gel permeation chromatography – a tool for determination of molar mass of polymers.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
Chromatography for Protein purification 1
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
Colligative Properties. How does the solute change the properties of the solvent? Consider aqueous solutions. Solvent = water. How do the properties of.
Reversed Phase HPLC Mechanisms Nicholas H. Snow Department of Chemistry Seton Hall University South Orange, NJ 07079
Four basic types of column chromatography where mobile phase is a liquid Partition Chromatography Bonded-Phase Liquid-Liquid Adsorption Chromatography.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Foundation GPC Part 2 – Basic Gel Permeation Chromatography
Advanced GPC Part 1 – GPC and Viscometry
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Gel Filtration Chromatography.
 Molar Mass And Molar Mass Distribution Molecular Weight Determination Laser Light Scattering Chromatography Size Exclusion (GPC) Mass Spectroscopy.
An Extended Range of Columns for Aqueous Size Exclusion Chromatography Greg Saunders, Graham Cleaver and Ben MacCreath, Varian, Inc., Church Stretton,
Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative &
Gel filtration chromatography y/college/voet/ /animat ed_figures/ch05/f5-6.html.
Drs. Wei Tian & Yanhui Chen Sep-Dec Main Content Chromatography Analysis Gas Chromatography (GC) High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography
Chromatography Chromatographic separation is based on distribution of separated compound (analyte) between mobile phase and stationary phase Richard Vytášek.
Chromatography Separates components in mixture: Based on - polarity
Types of Mechanism in the Chromatography
Magnet Analytical Chemistry Unit 4
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Best Broken into four categories
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
HPLC.
Size-exclusion Chromatography prof. aza Department of Pharmacy, Andalas University STIFI Perintis, Padang STIFAR, Pekan Baru STIFI Bhakti Pertiwi, Palembang.
CHROMATOGRAPHY. Chromatography Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient of sample.
Food Analysis Lecture 18 (03/27/2012) Basic Principles of Chromatography (3) Qingrong Huang Department of Food Science Read Material: Chapter 27, page.
BY G.SHRAVANI ION EXCHANGE AND GEL PERMEATI ON CHROMATOGRAPHY 1G.SHRAVANI.
Thermodynamic and Transport Properties of Biological Materials.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Principles of chromatography
Chromatography.
Size exclusion Chromatography
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
Experiments in Analytical Chemistry
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Gel Permeation Chromatography Size Exclusion Chromatography
Purification Of Proteins.
CHROMATOGRAPHY.
HPLC.
Size Exclusion Chromatography (SEC)
Chromatographic separation
Best Broken into four categories
HPLC.
High Performance Liquid Chromatography
Gel Filtration Chromatography.
Four basic types of column chromatography
Principle of separation of different components:
Polymer Characterization
High-Performance Liquid Chromatography
High-Performance Liquid Chromatography
Presentation transcript:

ADVANCED BIO-FRIENDLY POLYMERS Igor Lacík Gel permeation chromatography – a tool for determination of molar mass of polymers

Molecular weight: characterization techniques MnMn  techniques related to colligative properties (dependence on the number of molecules)  membrane osmometry (> g/mol)  vapor pressure osmometry (< g/mol)  mass spectrometry  electrospray ionization mass spectrometry (ESI-MS)  matrix-assisted laser desorption/ionization (MALDI)  size exclusion chromatography MwMw  static laser light scattering  analytical ultracentrifuge  size exclusion chromatography MzMz  static laser light scattering  analytical ultracentrifuge  size exclusion chromatography MM  viscometry  size exclusion chromatography MiMi wiwi MnMn MwMw MzMz

Molecular weight: characterization techniques MnMn  techniques related to colligative properties (dependence on the number of molecules)  membrane osmometry (> g/mol)  vapor pressure osmometry (< g/mol)  mass spectrometry  electrospray ionization mass spectrometry (ESI-MS)  matrix-assisted laser desorption/ionization (MALDI)  size exclusion chromatography MwMw  static laser light scattering  analytical ultracentrifuge  size exclusion chromatography MzMz  static laser light scattering  analytical ultracentrifuge  size exclusion chromatography MM  viscometry  size exclusion chromatography MiMi wiwi MnMn MwMw MzMz

1.Column separation technique 2.Based on enthalpy-free partitioning of analyzed solutes, most often the polymer chains, of different molecular weight / length (size) between mobile and stationary phases Size-exclusion chromatography – principle

Separation mechanism is based on the size Stationary phase pore size pore size distribution particle size Mobile phase   flow rate in ml/min providing “elution volume, V e ” or elution time, t e ”

Separation mechanism is based on the size Time 1 < Time 2 < Time 3 V e,1 < V e,2 < V e,3 Time 1 Time 2 Time 3

1.Column separation technique 2.Based on enthalpy-free partitioning of analyzed solutes, most often the polymer chains, of different molecular weight / length (size) between mobile and stationary phases V elution V e - elution volume for given size V 0 - interstitial volume (between particles of column packing) V t - total available volume of column (interstitial and pore volumes) K d - partition coefficient 0  K d  1 solute exluded solute permeated Size-exclusion chromatography – principle

Size-exclusion chromatography – setup Pump Commercial columns of defined characteristics for column packing: diameter, exclusion limit, pore-size distribution Injection of polymer of unknown molecular weight characteristics eluent signal = f(elution volume)Detector calibration curve with standards: elution volume = f(MW) molecular weight characteristics (MWD, M w, M n ) of polymer sign a l elution volume detector sign a l elution volume sign a l elution volume detector elution volume log M calibration curve elution volume log M elution volume log M calibration curve molecular weight distribution log M signal separation exclusion permeation

Pump Waters 515 MALLS SLD7000 WinGPC®7.4 Software Columns Rheodyne inj. or Waters Autosampler DegasserDRI Detector Waters 2410 PUMPINJECTORCOLUMNS MALLS RI DEGASSER SOFTWARE MAREK Size-exclusion chromatography – hardware

SEC is an indirect method  needs RELATION of elution volume (volume slice) to molecular weight = calibration several types of calibration 1. narrow distributed standards of the same polymer  universal calibration [  ] 1 M 1 = [  ] 2 M 2 ~ size of coil ~ V elution (Benoit et al, 1966) note: a) Mark-Houwink equations is related to MW range b) careful in low MW range where a ~ 0.5 J.Polym.Sci. 6, 1759 (1968) 3. absolute molecular weight detectors (LS, viscosity) 4. effective calibration (no match between standards and analyzed polymer) decrease in accuracy Size-exclusion chromatography – calibration

Remember  suppress interactions to avoid non-SEC phenomena (1) polymer - polymer (aggregation) – earlier elution, artificially increased molecular weight (2) polymer - column packing (adsorption) - delayed elution, artificially decreased molecular weight (3) eluent-column packing (repulsion) – earlier elution, artificially increased molecular weight (4) polymer - eluent (aggregation) - earlier elution, artificially increased molecular weight (5) etc. Size-exclusion chromatography – hints/experience

 water-soluble polymers (polyelectrolytes) ProblemCure H-bonding hydrophobic interactions polyelectrolyte effect adsorption (ion inclusion) repulsion (ion exclusion) calibration concentration effect resolution (eluent viscosity) Eluent composition & column selection Direct calibration with standards of well-defined M p Optimized solute concentration Temperature of analysis PSSSuprema HEMA GRAM (DMAc) TosoH BiosepTSK PWXL Polym. Laboratories Waters Ultrahydrogel Remember  suppress interactions to avoid non-SEC phenomena Size-exclusion chromatography – hints/experience

sample EG system peaks - salt excluded from PE region  eluent: 0.1M LiNO 3, 0.04 M phosphate bufer, pH 8.0, 0.01M NaN 3  columns:Suprema 100, 1000, 3000, Å (8 x 300 mm, 10  m)  flow rate ml/min (ethylene glycol– internal standard)  temperature60-80ºC  calibration p(NaA) standards 1 250– g/mol (PSS, Mainz, Germany)  sample: concentration mg/ml, injection volume 200  L  data acquisition and evaluationWinGPC7 (PSS, Mainz, Germany) or 0.1M Na 2 HPO 4 (pH 9) or other compositions or 0.1M Na 2 HPO 4 (pH 9) or other compositions  water-soluble polymers (polyelectrolytes like poly (acrylic acid)) Remember  suppress interactions to avoid non-SEC phenomena Size-exclusion chromatography – hints/experience

Calibration curve (polyacrylic acid) Guide-lines: no upward curvature at high M.w, i.e. no adsorption of PAA to column packing (solute-gel interactions) pronounced at  M.w. variation of ionic strength - test to estimate the interactions  ionic strength too low: elution volumes increase due to electrostatic interactions  ionic strength too high: elution volumes increase due to hydrophobic interactions  remove charged monomer by dialysis: as it adds to the ionic strength of eluent  a suitable ionic strength is in case of the lowest elution volumes Remember  suppress interactions to avoid non-SEC phenomena Size-exclusion chromatography – hints/experience

 decrease in hydrodynamic volume of polymer coil at higher polymer concentration leads to the artificially lower M.w.  lowering the sample concentration until the constant molar mass is reached yet detector sensitivity is sufficient Concentration effect (polyacrylic acid) PAA concentration in mg/ml E+5 4E+5 6E+5 8E+5 Elution volume at peak [ml] Molar mass at peak [g/mol] Polymer concentration [ml/g] Remember  suppress interactions to avoid non-SEC phenomena Size-exclusion chromatography – hints/experience

! EXTREME SENSITIVITY TO VARIATION IN THE FLOW RATE! Accuracy of the flow rate (polyacrylic acid) sample EG  it is essential flow rate is controlled by the flowmarker (ethylene glycol) which also controls the pore volume and any changes on columns Size-exclusion chromatography – hints/experience

 the partitioning of the solute between mobile and stationary phases depends on viscosity of mobile phase: improved partitioning  improved resolution  viscosity of aqueous mobile phase can be adjusted to that of the organic one by the temperature of analysis Effect of temperature of analysis (polyacrylic acid) room T Size-exclusion chromatography – hints/experience

Final hints with special emphasis to the aqueous-phase SEC fast advancing in the last years with strong achievements (columns and new experience) there exist more and more examples of very precise analysis with high resolution (a strong improvement in aqueous-phase SEC) patience in thorough testing after thinking of all the possibilities which may hamper the experiment column history may play a role (more in aqueous-phase SEC than in aqueous-phase SEC) Size-exclusion chromatography – hints/experience

Size-exclusion chromatography – final slide This is also the common SEC analysis