Vicon Workstation Motion Capture Essentials

Slides:



Advertisements
Similar presentations
After the leg is in swing (at t =0.28), the hip flexors acted to flex the hip (H2) and then immediately before contact the hip extensor moment dominated.
Advertisements

Principles of Biomechanics
KINETIC ANALYSIS OF GAIT INITIATION D. Gordon E. Robertson, PhD, FCSB 1 Richard Smith, PhD 2 Nick ODwyer, PhD 2 1 Biomechanics Laboratory, School of Human.
Kocsis László PhD – Dept. of Applied Mechanics Budapest University of Technology and Economics Biomechanical laboratory of BUTE.
Dynamometry D. Gordon E. Robertson, PhD, FCSB Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, Canada 1Biomechanics Laboratory,
Inverse Dynamics and Joint Power Analysis
Inverse Dynamics D. Gordon E. Robertson, PhD, FCSB School of Human Kinetics University of Ottawa.
Angular Kinematics D. Gordon E. Robertson, PhD, FCSB
Welcome to a tour of Limb Volumes Professional 6.0 LVP6.0 is the latest version of the world famous and widely used lymphedema tracking and reporting software.
Kinetics of Hula Hooping: An Exploratory Analysis
3-Dimensional Gait Measurement Really expensive and fancy measurement system with lots of cameras and computers Produces graphs of kinematics (joint.
Biomechanics of Walking and Stair Ascent and Descent D. Gordon E. Robertson, Ph.D. Biomechanics, Laboratory, School of Human Kinetics, University of Ottawa,
D. Gordon E. Robertson, PhD, FCSB School of Human Kinetics University of Ottawa.
Lecture XIII Assignment 1.Abstract a research article that utilizes a force platform to collect data. The article should be related to your academic area.
Kinetic Analysis of the Lower Limb during the Pirouette in Ballet D. Gordon E. Robertson, PhD, FCSB Cristina Fulop Tama Davis Courtney Timm Biomechanics,
Introduction to Biomechanics EXSC 408L - Fall ‘10 Dr. Kathleen E. Sand (BU 2007; USC 2004) subject line: EXSC 408L … Office Hours.
Biomechanics of Locomotion D. Gordon E. Robertson, PhD, FCSB Biomechanics, Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, Canada D.
BIOMECHANICAL DATA INTEGRATION LATEST TECHNOLOGY G. Ariel 1, A. Finch 2 & A. Penny 1 1 Ariel Dynamics, San Diego, California 2 Biomechanics Laboratory,
TWU Biomechanics Laboratory Lower-limb dynamics in two approaches of stair descent initiation: walk and stand Ketki Rana, Kunal Singhal, Sangwoo Lee, and.
Segmental Power Analysis of Walking
KINETIC ANALYSIS OF GAIT INITIATION D. Gordon E. Robertson, PhD, FCSB 1 Richard Smith, PhD 2 Nick O’Dwyer, PhD 2 1 Biomechanics Laboratory, School of Human.
Biomechanics of Gait Walking
Analog Data Processing with BioProc3 Part Two EMG Analysis Techniques.
Kinetic Rules Underlying Multi-Joint Reaching Movements. Daniel M Corcos†, James S. Thomas*, and Ziaul Hasan†. School of Physical Therapy*, Ohio University,
Prof. Anthony Petrella Musculoskeletal Modeling & Inverse Dynamics MEGN 536 – Computational Biomechanics.
Kinetics versus Kinematics for Analyzing Locomotor Coordination D. Gordon E. Robertson, Ph.D. School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Musculoskeletal Modeling Colin Smith. A method for Studying Movement Things we can measure in movement: – Kinematics (using motion capture) – Output Forces.
Moment Power Analysis and Absolute Power Method D. Gordon E. Robertson, PhD, FCSB Biomechanics Laboratory, School of Human Kinetics, University of Ottawa,
Modeling and Kinetics: Forces and Moments of Force* * Some of the materials used in this lecture are derived from: 1.Winter, D. A. (1990). Biomechanics.
Analog Data Processing with BioProc3 Part Three Impact, Work and Force Analysis Techniques.
Moment Power and Work of the Ankle, Knee and Hip during Three Bimanual Lifting Techniques Maria Nicolaou, B.Sc.* D. Gordon E. Robertson. Ph.D.** *Department.
This includes but is not limited to:  Vicon  Switch on power strip located on wire rack  Should be turned on before software is opened  EMG  Delsys.
SS5305 – Data Cleaning and Output 1. Objectives Skeletal Hierarchy Marker Data Position Re-targeting Data Cleaning Motion Reconstruction Data Output and.
Biomechanics of Walking
Lesson 6. Quote of the day... “It is the mark of an educated mind to be able to entertain a thought without accepting it.” - Aristotle.
TRAINING AFFECTS KNEE KINEMATICS AND KINETICS IN CUTTING MANEUVERS IN SPORT CASEY GRAHAM TIFFANY MEIER MICHELE BENANTI.
The Biomechanical Wizard By Gideon Ariel, Ph.D. Guangdong Provincial Institute of Sport Science February 22nd 2005.
BIPEDAL LOCOMOTION Prima Parte Antonio D'Angelo.
Kinetics of Hula Hooping: An Exploratory Analysis Tyler Cluff D. Gordon E. Robertson Ramesh Balasubramaniam School of Human Kinetics Faculty of Health.
COMPARISON OF KINETICS OF RAMP AND STAIR DESCENT Andrew Post, B.Sc. and D.G.E. Robertson, Ph.D., FCSB School of Human Kinetics, University of Ottawa, Ottawa,
Mechanics of Sprinting D. Gordon E. Robertson, Ph.D. Biomechanics, Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
SIMULATION OF THE AIRBORNE PHASE OF THE GRAND JETÉ IN BALLET
Comparison of Loaded and Unloaded Ramp Descent Jordan Thornley, B.Sc. and D. Gordon E. Robertson, Ph.D., FCSB School of Human Kinetics, University of Ottawa,
Observing and Analyzing Performance (1) The Nature of Skills –Movement patterns - a general series of movements having common elements. Ex: running, jumping,
Introduction The front-kick (mae geri) in karate is one of the strongest and most easily mastered kicks. This project examined the powers produced by the.
Swimming Research and Education at the Centre for Aquatics Research and Education (CARE) The University of Edinburgh Ross Sanders Hideki Takagi.
Discussion Figure 3 shows data from the same subject’s lead leg during planned gait termination. The lead leg arrived first at the quiet stance position.
Biomechanics of Walking
Three-dimensional analyses of gait initiation in a healthy, young population Drew Smith 1 and Del P. Wong 2 1 Motion Analysis Research Center (MARC), Samuel.
Anthony Beeman.  Since the project proposal submittal on 9/21/15 I began work on the Abaqus Kinematic model utilizing join, hinge, and beam elements.
KINETIC ANALYSIS OF THE LOWER LIMBS DURING FORWARD AND BACKWARD STAIR DESCENT WITH AND WITHOUT A FRONT LOAD Olinda Habib Perez & D. Gordon E. Robertson.
SS5305 – Popular Marker Setups 1. Objectives Marker Data Measurement Sequence Project Automation Framework (PAF) Popular marker setups PAF Interface 2.
The Biomechanical Project at the Atlanta Olympic Games 1996 Sponsored by the International Track and Field Coaches Association by Gideon Ariel, Ph.D. Wingate.
Chapter One What is Biomechanics? MET 235.
ABSTRACT Technological advances have made it possible to integrate, synchronize, and simultaneously display video records, kinematic, kinetic, EMG, and.
COMPARISON OF ANKLE, KNEE AND HIP MOMENT POWERS DURING STAIR DESCENT VERSUS LEVEL WALKING François G. D.Beaulieu, M.A.; Lucie Pelland, Ph.D. and Gordon.
Muscle function during running and walking Forward dynamical simulations Split-belt treadmill with embedded force plates.
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Stabilization of a Dynamic Walking Gait Simulation J. Comput. Nonlinear Dynam.
COMPARISON OF LOADED AND UNLOADED STAIR DESCENT Joe Lynch, B.Sc. and D.G.E. Robertson, Ph.D., FCSB School of Human Kinetics,University of Ottawa, Ottawa,
Animating Human Locomotion
Date of download: 9/29/2017 Copyright © ASME. All rights reserved.
Variation in Shoulder Elevation
Computer Animation cgvr.korea.ac.kr.
Breen D1, Marshall BM 1,2, Falvey É 1,3, Franklyn-Miller A 1,3
Clemson University Department of Bioengineering Clemson, SC 29634
Biomechanics for the 21st Century by Gideon Ariel, Ph.D.
Segmental Power Analysis
BioProc2/3 Analog data processing Part Three
Synthesis of Motion from Simple Animations
Static Foot Structure May Predict Midfoot Mechanics
Presentation transcript:

Vicon Workstation Motion Capture Essentials D. Gordon E. Robertson, PhD

Biomechanics Laboratory, School of Human Kinetics Outline Select appropriate marker set and type of markers Determine number of cameras and their locations Select appropriate location, number and types of force measuring devices (force platforms, force transducers) Other demands: EMGs, netting, speed guns, standardized footwear and equipment? Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 1. Marker Sets Motion capture requires selection of a suitable marker set Types: individual markers clusters of markers (includes wands) on rigid structures virtual markers (uses wands to identify body locations) Static marker set this set is necessary to establish joint centres and their 3D relationships with the dynamic marker set virtual marks can be included Dynamic marker set this may be a reduced set that with a combination of individual markers and/or clusters Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Static Marker Sets subject in static posture with marker clusters Helen Hayes marker set was a early simplified system but is not appropriate for full body 3D analyses Vicon’s Plug-in-gait marker set is a more robust full body marker set but requires several anthropometric measurements (e.g., mass, height, leg length, knee width, ankle width, shoulder offset, elbow width, wrist width, & hand thickness) uOttawa marker set is a modified version of Plug-in-gait. It uses hip, iliac crest, medial limb, and ear markers, but no ASIS or PSIS markers. It also requires fewer anthropometric measurements (e.g., mass, height, hip offset, & shoulder offset) clusters may also be used for some or all segments instead of non-joint markers Biomechanics Laboratory, School of Human Kinetics

Plug-in-gait Marker Set No hip markers No medial markers at knees, ankles, elbows, and wrists Head markers not over ears (location of cofg) Pelvis markers (ASIS & PSIS) are horizontally located Only one markers on foot Potentially arm & leg markers are linear avoid placing markers linearly on a segment Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics uOttawa Marker Set Hip markers Medial markers at knees, ankles, elbows, and wrists Head markers over ears No ASIS or PSIS markers Two markers for each foot, hallux optional Potentially arm & leg markers are linear Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Clusters Usually 3 or 4 markers 4th marker can be offset cluster must be well fixated to the skin can be difficult to automatically digitize can impede motion Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Dynamic Marker Sets this marker set that is similar to the static but with extraneous markers removed medial markers when clusters are used individual markers can be removed Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 2. Camera Setup Number of cameras depends on complexity of task and complexity of the model 2 to 4 cameras may be sufficient for analyzing planar type motions of one side of the body 6 or more cameras for full-body models of small volumes 10 or more for large volumes such as walkways, cricket pitches 6 cameras 12 cameras 7 cameras 10 cameras, 2 overhead Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 3. Force Platforms plates in 4 stairs and 1 in ground two side-by-side on moveable platform two side-by-side and one offset Usually necessary for later kinetic analyses One plate or multiple plates. How many? Imbedded into floor or into stairway Size: small (40x60): good for starts or static jumps, easy to miss for running studies large (60x90): good for running studies but can result in multiple feet on same plate (prevents inverse dynamics) Location: side-by-side, separated, alternating, movable mounts for up to 6 large plates Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 4. Other Equipment VO2 measurements EMGs of leg muscles torque resistance measured by ergometer Biomechanics Laboratory, School of Human Kinetics

Example: Single Markers, Side Kick Single markers one either side of each joint and one extra mid segment Three force platforms All joints can be analyzed since there are no closed loops Biomechanics Laboratory, School of Human Kinetics

Example: Clusters, Olympic Lifting Clusters identify limb segments Two force platforms Only ankle, knee, hip, and pelvis kinetics can be analyzed Arms kinetics are not possible because of the bar connection Biomechanics Laboratory, School of Human Kinetics

Trajectory Digitization Vicon Workstation Trajectory Digitization

Biomechanics Laboratory, School of Human Kinetics Steps Calibration Reconstruction Labeling Autolabeling Defragmentation Gap filling Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 1. Calibration Static origin and axes are defined Dynamic calibration wand is used to calibrate volume Accuracy usually < 1 mm Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 2. Reconstruction Multiple 2D views to one 3D Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 3. Labeling select the static trial label each trajectory save for autolabelling Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 4. Autolabelling load dynamic trial(s) apply autolabelling Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 5. Defragmentation join line fragments with same name Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics 6. Gap Filling fill gaps with interpolating spline Biomechanics Laboratory, School of Human Kinetics

Done Ready for Kinematic/Kinetic Analyses Biomechanics Laboratory, School of Human Kinetics

Inverse Dynamics and Joint Power Analysis Visual3D Inverse Dynamics and Joint Power Analysis

Biomechanics Laboratory, School of Human Kinetics Marker and Force Data marker data come in a .C3D file created by Vicon, Motion Analysis, Qualysis or similar motion capture system SIMI and APAS may also be used but data must be placed in a ASCII (.FSV) file by, for example, BioProc2/3 force data come with the .C3D file but may also be collected and placed in an ASCII (.FSV) file by BioProc2/3 data may be streamed directly to Visual3D using newest version of Visual3D and compatible motion capture system, e.g., Nexus Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Creating the Model first a static trial is loaded to create the model (you can use a movement trial) a previous model may be used for a similar marker set model is customized for each participant (mass and height etc.) ideally markers are located at each joint but these markers do not have to be included in the movement (dynamic) trials should save the model file (.MDH) separately for use with other trials or experimental conditions of the same person new models must be created for each new marker set Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Model Building Screen create segments create landmarks enter body mass and height Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Movement Trials one or more movement trials may be loaded into same workspace (.CMO), essential if trials are to be averaged model is applied to each trial trial may be viewed with bones or geometrical solids for each segment ground reaction forces should be checked errors in force platform locations and parameters may be checked and changed in necessary Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Workspace Screen static trials movement trials tags to identify experimental conditions Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Event Labeling if events were not created by motion capture software they can be added automatically or manually with Visual3D special events used for reports can also be added (e.g., BEGIN, END, HIT) events should be checked for accuracy using GUI Biomechanics Laboratory, School of Human Kinetics

Signal and Event Processing Screen event button signal tree body at current event signal histories with events marked Biomechanics Laboratory, School of Human Kinetics

Data Processing Pipeline a pipeline may be applied to process the data for inverse dynamics, energy, or power analyses a script may be used to perform these operations repeatedly a typical script (.V3S) includes interpolation and data filtering special forces may be added such as moving force platforms, transducer forces, or pedal forces Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Pipeline Form • commands • pipeline • options • import signals • opn/save scripts Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Graphical Reports reports, including graphs, of the various kinematics and kinetics are created next special tags may be used to display only certain types of trials, e.g., right vs. left leg starts, barefoot vs. shod gait, loaded vs. unloaded lifts these tags are created in the workspace area basic reports (.RGT) may be loaded or created and saved for later repeated use graphs may be exported for presentation Biomechanics Laboratory, School of Human Kinetics

Biomechanics Laboratory, School of Human Kinetics Reporting Screen contents of pages report pages graphical or tabular reports select page viewed here Biomechanics Laboratory, School of Human Kinetics

Export Data to MatLab or BioProc3 kinematic or kinetic data may be exported in .C3D or ASCII files BioProc3 has capability of computing total, internal and external work, angular impulses and work done by individual bursts of power script is used to create ASCII file for BioProc3 MatLab can compute foot clearance Biomechanics Laboratory, School of Human Kinetics

BioProc3: External/Internal/Total Work external work internal work total work Biomechanics Laboratory, School of Human Kinetics

BioProc3: Work Done in Bursts which moment of force peak power peak moment mean power total work done Biomechanics Laboratory, School of Human Kinetics

Questions? Comments? www.health.uottawa.ca/biomech/watbiom www.humankinetics

Finis Muchas Gracias