Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney.

Slides:



Advertisements
Similar presentations
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advertisements

W. M. Snow Physics Department Indiana University/IUCF EDM collab meeting Monitoring the Cold Neutron Beam (During Experiment) What to measure (fluence.
A polarized solid state target for photon induced double polarization experiments at ELSA H. Dutz TR16 Bommerholz Hartmut Dutz, S. Goertz, A.
Using polarized 3 He spin filter at the SNS - Update on current development W.T. Hal Lee Spallation Neutron Source.
Super-B Factory Workshop January 19-22, 2004 Accelerator Backgrounds M. Sullivan 1 Accelerator Generated Backgrounds for e  e  B-Factories M. Sullivan.
Helium 3 Neutron Precision Polarimetry CHRISTOPHER CRAWFORD, ROEL FLORES, CHRISTOPHER MENARD*, ELISE MARTIN, University of Kentucky *present address: Washington.
Managed by UT-Battelle for the Department of Energy Development of Spin-Echo Scattering Angle Measurement Wai Tung Hal Lee 1, Roger Pynn 1,2, Paul Stonaha.
Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2,
Conceptual Design: MACS is designed to maximize the efficiency for energy resolved surveys of Q-space in the sub-thermal energy range. Two innovations.
Instrument Development Test Station at HFIR CG1 Lowell Crow, May 15, 2009.
Beijing, Feb 3 rd, 2007 LEPOL 1 Low Energy Positron Polarimetry for the ILC Sabine Riemann (DESY) On behalf of the LEPOL Collaboration.
HYSPEC HYSPEC INSTRUMENT DESIGN – OUTLINE  The two “models” considered for HYSPEC – inside & outside (Mark)  A breakdown of the components of the two.
HYSPEC Recent progress and polarization analysis capabilities ORNL: B. Winn, V. Ovidiu Garlea, M. Graves- Brook, Peter Jiang, X. (Tony) Tong BNL: L. Passell,
Proposal for a High Intensity Chopper Spectrometer at LANSCE Science requiring high sensitivity neutron spectroscopy Limitations of current instrumentation.
NCNR, NIST Gaithersburg, MD Internet: Neutron Spin Echo Spectroscopy (NSE) Dobrin P. Bossev, Steven.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
Polarized 3 He Target for 12 GeV Experiments J. P. Chen, August 15, 2012, JLab  Experiments and requirements  Target performance from previous experiments.
Motivation Polarized 3 He gas target Solenoid design and test 3 He feasibility test Summary and outlook Johannes Gutenberg-Universit ä t Mainz Institut.
HYSPEC options for wide angle TOF neutron polarization analysis with polarized 3 He L. Passell, V.J. Ghosh, L.D. Cooley, I. Zaliznyak, S.M. Shapiro, W.J.
5th workshop on scientific collaboration/JINR/Dubna HJL Basis HFR IBR-2 user policy collaboration Project REMUR: Investigation of the structure.
Tungsten Calorimeter Model Calculations and Radiation Issues Pavel Degtiarenko Radiation Control Group, Jefferson Lab.
Choosing the Right Neutron Spectrometer Dan Neumann NIST Center for Neutron Research
Can Multipole Magnetic Fields Play a Useful Role in Transporting, Polarizing and Focusing Neutron Beams on Small Samples? V. J. Ghosh A.U. Luccio L. Passell.
Managed by UT-Battelle for the Department of Energy Polarized 3 He Filling Stations Xin Tong (Tony) Instrument Development Group Neutron Facilities Development.
Normalization of the NPDGamma Experimental Data F. Simmons, C. Crawford University of Kentucky, for the NPDGamma collaboration Background: NPDγ Experiment.
Beam Polarimetry Matthew Musgrave NPDGamma Collaboration Meeting Oak Ridge National Laboratory Oct. 15, 2010.
Applications of polarized neutrons V.R. Skoy Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research Dubna, Moscow Region, Russia.
HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.
Systematic studies of neutrons produced in the Pb/U assembly irradiated by relativistic protons and deuterons. Vladimír Wagner Nuclear physics institute.
Polarized Neutrons in ANSTO – From LONGPOL to Pelican, Taipan, Sika, Platypus and Quake Dehong Yu and Shane Kennedy Bragg Institute, ANSTO, Australia.
MACS Concept and Project Status Making best use of CW source MACS-imizing incident flux MACS-imizing detection efficiency From concept to reality Collin.
HYSPEC HYSPEC: A High Performance Polarized Beam Hybrid Spectrometer at the SNS Beamline 14B I.Zaliznyak 1, S. Shapiro 1, L. Passell 1, V. Ghosh 1, W.
David Winogradoff Haverford College NCNR, NIST Ivan Schroder
The NCNR Spin-Polarized Triple-Axis Spectrometer (SPINS) The SPINS instrument is located at the heart of the cold neutron guide hall of the NIST Center.
Experimental Studies of Spatial Distributions of Neutrons Produced by Set-ups with Thick Lead Target Irradiated by Relativistic Protons Vladimír Wagner.
Shielding Helium Cold neutron source Shutter Cooled filters Radial Collimators Variable Aperture Focusing monochromator on translation stage Focusing monochromator.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST September 24, 2002Collin L. Broholm Timothy D. Pike 1 Scientific Program and Requirements.
1 How Can We Get More Neutrons? Upgrade Paths for the EDM Geoff Greene University of Tennessee /Oak Ridge National Laboratory Oct 2006.
1 Possibility to obtain a polarized hydrogen molecular target Dmitriy Toporkov Budker Institute of Nuclear Physics Novosibirsk, Russia XIV International.
ESS - SANS Instrumentation pulsed source SANS, using a wide range of wavelengths, uses more of the available flux than a continuous source. For same time.
Polarization Measurement for Npdgamma at the SNS M. Jon Dadras.
Conceptual design and performance of high throughput cold spectrometer : MACS Why MACS Layout and key elements Performance Data collection Scientific program.
Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.
MCNSI meeting, February 2006 Contents: People –V. Ryukhtin left for part time only Multichannel focusing benders – continuation –resolution functions.
NMI3 meeting, ISIS, September 26-29, 2005 Contents: Overview of new capabilities of the RESTRAX software Numerical optimizations of TAS parameters Virtual.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
Conceptual Design of the Neutron Guide Holding Field Christopher Crawford, Yunchang Shin University of Kentucky nEDM Collaboration Meeting
SONA Transition Optimization in the Brookhaven OPPIS A. Kponou, A. Zelenski, S. Kokhanovski, V. Zubets & T. Lehn B. N. L.
CAPABILITIES Desire to measure lattice and spin dynamics in small single crystals:  Need high flux at sample position.  Low background Science Needs:
Transmission Measurement Basic Outline. Transmission Curve Describes the percentage of a signal that is transmitted through an object (filter) over a.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline BNL’s HYSPEC project and its place in the.
HYSPEC IDT Introduction to HYSPEC: Overview of the Conceptual Design and Top Level Specifications. Outline Overview of the HYSPEC layout and principal.
Neutron Scattering Group March, 2001 A High Performance Hybrid Spectrometer for the Single Crystal Spectroscopy at the Pulsed SNS  Scientific case and.
HYSPEC IDT Options for polarization analysis with 3 He for the Hybrid Spectrometer (HYSPEC) L. Passell, V.J. Ghosh, I. Zaliznyak, S. Shapiro, W. Leonhardt,
Moving the NPDGamma Experiment to the SNS FnPB Christopher Crawford University of Kentucky overview of NPDGamma transition to the SNS expected.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline Polarization analysis and the HYSPEC place.
Design and Simulations of the Source of Polarized Slow Positrons at ELI-NP Nikolay Djourelov ELI-NP, IFIN-HH, 30 Reactorului Str, MG-6 Bucharest-Magurele,
Neutron production and iodide transmutation studies using intensive beam of Dubna Phasotron Mitja Majerle Nuclear Physics Institute of CAS Řež, Czech republic.
Polarized neutrons and high magnetic fields on TAS IN22 L.P. Regnault CEA-Grenoble PINS Workshop BNL 6-7 April 2006.
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
Status of Polarimeters and Polarized Targets: what are the plans for development of polarized targets to meet the needs of the Day 1 and future experimental.
Timelike Compton Scattering at JLab
Beam dynamics simulation with 3D Field map for FCC RF gun
Positron production rate vs incident electron beam energy for a tungsten target
SNS Injection Fields and Coils
Polarized Internal Gas Target in a Strong Toroidal Magnetic Field
Physics Design on Injector I
MIRACLES budget: Summary of the 3 configurations
Injector Experimental Results John Schmerge, SSRL/SLAC April 24, 2002
Scope Setting Meeting MIRACLES
Presentation transcript:

Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney

Outline NCNR triple-axis BT7 specs He-3 pros and cons Setup and components Transport tests Performance Monitoring tool

NCNR Triple-Axis Spectrometers 1 cold neutron (SPINS). Can use SM transmission polarizers. 2 thermal in confinement (BT7 and BT9). BT2 recently decommissioned was only thermal polarized beam using Heusler. BT9 (current BNL secondary) is scheduled for upgrade similar to BT7.

BT7 specifications Contact: Ying Chen ( ) or Jeff Lynn ( ) Monochromators: doubly focusing (DFM) interchangeable 20x20cm 2 PG002 and Cu220 Analyzer-Detector: air-pad system with horizontal focusing or flat crystal array and multi-detector or PSD. Flux: double-focusing PG002 at 40meV (open-50’) flux=1.8x10 8 n/cm 2 /s Background: 1 ct/min at 14.7 elastic PG filter (open-50’) See

DFM Contact: Stephen Smee ( ) Instrument Development Group at Johns Hopkins

BT7 with the BNL magnet

BT7 3-axis Spectrometer with He-3 Polarized Beam

Polarized Beam Setup He-3 cells are polarized offline and transferred to the BT7 solenoids at the start of the experiment. If the cell has been already characterized, just check the transmission. Setup spin transport components: flippers and guide fields. Setup is comparable to Heusler monochromator change.

Why He-3? Not a monochromator. Use with any monochromator. Wide wavelength range. Wide angular acceptance. Transmission and neutron polarization competitive with crystal polarizers. Future performance improvements and online pumping

He-3 problems Transmission wavelength dependent. Different cells for different wavelength ranges. Requires highly homogeneous magnetic field environment and thus takes up beam line space. Related high magnetic field experimental challenges. Non-pumped has time dependent transmission. Requires transport from longitudinal to transverse neutron polarization.

He-3 polarized beam components Polarizer cell and solenoid Analyzer cell and solenoid Larmor-precession spin flippers Longitudinal guide fields Vertical guide fields Sample guide fields

He-3 polarizer 25cm long magnetically shielded solenoid space limited. 9 cm diameter entrance and exit holes to accommodate BT7 incident beam. 20cm diameter solenoid shield to accommodate 10cm diameter glass cell. ΔB/B  /e lifetime: intrinsic 300 hours. inline 130 hours

He-3 analyzer Borrowed from reflectometer so not ideal for BT7. 46cm long magnetically shielded solenoid. This will be reduced to save beam line space without much loss in lifetime. 9 cm diameter entrance and exit holes to accommodate BT7 exit beam. 28cm diameter solenoid shield to accommodate 10cm diameter glass cell. ΔB/B  /e lifetime: intrinsic 450 hours. inline 350 hours

Spin Flippers 30 year old flippers need replacing with larger beam area and more heavily anodized Al wire. Calculation suggests that even with  and  flipping ratio still > 100

Longitudinal Guide Simple short solenoid serves as adiabatic guide field or transition from vertical to longitudinal guide field.

Vertical Guide Vertical guide sections which are too short can’t transport from He-3 polarizing solenoid unless they physically touch the magnetic shield.

Flipping Ratio

Transport Tests We have made careful transport checks for all of our components on a 3.7meV polarized beam reflectometer beam line with intrinsic flipping ratio of 90. Only found problems with precession spin- flippers, and short vertical guide sections near He-3 magnetic shield.

Handling Time Dependence He-3 polarization decay is highly predictable unless there are problems. Simplest experimental check is to monitor the flipping ratio and compare to calculated. With additional beam monitors it is also possible to monitor He-3 polarizer transmission. This may require handling higher orders in the beam, and difficult to implement for analyzer were intensity may be low. Spread sheet tool

BT7 He-3 polarizer performance

BT7 He-3 analyzer

Conclusion He-3 is a flexible competitive solution to crystal polarizers. BT7 triple-axis polarized beam setup works OK but needs work on spin transport. All of the components tested OK except for spin-precession flippers. We plan to have a He-3 cell polarization lab setup in the next 4-6 months.