Sterilization (continued)

Slides:



Advertisements
Similar presentations
Heat Transfer in Fermentation
Advertisements

EGR 334 Thermodynamics Chapter 4: Section 10-12
EGR 334 Thermodynamics Chapter 4: Section 6-8
Chapter 2 Introduction to Heat Transfer
Thermodynamics April 27, 2015April 27, 2015April 27, 2015.
Entropy balance for Open Systems
First Law of Thermodynamics - Open Systems
Chapter 4 Mass and Energy Analysis of Control Volumes (Open Systems)
CHAPTER 5: Mass and Energy Analysis of Control Volumes
STERILISATION (PAGE 371, Doran e-book).
Advanced Thermodynamics Note 6 Applications of Thermodynamics to Flow Processes Lecturer: 郭修伯.
Chapter 4.2: Flow Across a Tube Bundle Heat Exchanger (Tube Bank)
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Advanced Thermodynamics Note 4 The Second Law of Thermodynamics
Recovery and Purification of Bio-Products (Chapter 11, M
PUMPS AND GAS-MOVING EQUIPMENT
Exergy: A Measure of Work Potential Study Guide in PowerPoint
Mass and Energy Analysis of Control Volumes. 2 Conservation of Energy for Control volumes The conservation of mass and the conservation of energy principles.
CHE/ME 109 Heat Transfer in Electronics
CHE/ME 109 Heat Transfer in Electronics
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
Principles of Liquid Flow through Pipelines
Department of Mechanical Engineering ME 322 – Mechanical Engineering Thermodynamics Lecture 27 Gas Power Generation The Brayton Cycle.
Sterilization of air: Methods Most industrial fermentations are operated under vigorous aeration and the air supplied to the fermenter must be sterilized.
Fluid FRICTION IN PIPES
Convection Prepared by: Nimesh Gajjar. CONVECTIVE HEAT TRANSFER Convection heat transfer involves fluid motion heat conduction The fluid motion enhances.
Sterilization Lecture 7 Tahir.
Valves In Industry (Part 3).
Water piping design.
Sterilization (continued)
Chapter 7: STERILIZATION
Temperature Driving Force Concentric Pipe Heat Exchangers
Fouling Factor: After a period of operation the heat transfer surfaces for a heat exchanger become coated with various deposits present in flow systems,
Sterilization CP504 – ppt_Set 09
PM3125: Lectures 10 to 12 Content of Lectures 10 to 12: Heat transfer:
Sterilization CP504 – Lecture 15 and 16
The First Law of Thermodynamics
Pressure drop during fluid flow
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Anharmonic Effects. Any real crystal resists compression to a smaller volume than its equilibrium value more strongly than expansion to a larger volume.
Chapter 5: BIOREACTOR DESIGN & SCALE-UP
CHAPTER 5: Mass and Energy Analysis of Control Volumes
CP502 Advanced Fluid Mechanics Compressible Flow Part 01_Set 02: Steady, quasi one-dimensional, isothermal, compressible flow of an ideal gas in a constant.
CP502 Advanced Fluid Mechanics Compressible Flow Lectures 1 & 2 Steady, quasi one-dimensional, isothermal, compressible flow of an ideal gas in a constant.
 What is Evaporation?  What is Boiling point?  Comparison between Evaporation and Boiling Point.
17. Thermal Behavior of Matter 1. Gases 2. Phase Changes 3. Thermal Expansion.
Chapter 11 Heat Exchangers ( ) Heat Exchangers.
Sterilization and Disinfections. Sterilization Freeing of an environment from all living microorganisms includes bacteria and their spores, fungi, parasites.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Matter Intermolecular Forces  Are the forces between neighboring molecules.
Halliday/Resnick/Walker Fundamentals of Physics
Class 20 Scaleup Book Chapter 10 It seems insignificant but there is a general chemical rule that says each 10x scale up of the batch size takes as much.
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Flow of Compressible Fluids. Definition A compressible flow is a flow in which the fluid density ρ varies significantly within the flowfield. Therefore,
Heat Transfer by Convection
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 8 Internal flow.
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
Advantages of Rotating Machines Less balancing problems Low lubricating oil consumption Higher reliability.
Sterilization and Bioreactor Operation
Chapter 5 Part 2 Mass and Energy Analysis of Control Volumes Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 8th edition.
Biotechnology 2.  The method of choice for sterilization in most labs is autoclaving; using pressurized steam to heat the material to be sterilized.
1 Chapter 5 Mass and Energy Analysis of Control Volumes.
DESIGN OF CONTINUOUS STERILIZATION PROCESSES
Chapter 5: BIOREACTOR DESIGN & SCALE-UP
Desuperheater Heat Transfer Device Manufactured by Maniks
Chapter 5 The First Law of Thermodynamics for Opened Systems
Process Equipment Design and Heuristics – Heat Exchangers
Chapter 5 Mass and Energy Analysis of Control Volumes Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 6th edition.
Mass and Energy Analysis of Control Volumes (Open Systems)
The Kinetic theory Pressure
Presentation transcript:

Sterilization (continued) CP504 – Lecture 17 Sterilization (continued) Learn about thermal sterilization of liquid medium Learn about air sterilization Learn to do design calculations R. Shanthini 25 Nov 2011

Continuous Sterilization: Simplifies production planning Therefore gives maximum plant utilization and minimum delays Provides reproducible conditions Can be operated at high temperature (1400C) Therefore sterilization time can be reduced (2 to 3 min) Requires less steam and less cooling water Suitable when the capacity of operation is high High initial capital investment (use of aseptic transfer system for the sterile broth to be transported to a sterile vessel) R. Shanthini 25 Nov 2011

Continuous Sterilization: It is the only option if the medium is to be exposed to high temperatures for a short time (HTST process) to avoid denaturation of proteins or to avoid destruction of some of the enzymes, etc., since it is not possible in commercial scale operations in batch sterilization to quickly heat large volumes of the medium in short time and cool it also in short times. R. Shanthini 25 Nov 2011

sterilization takes place) Continuous Sterilization: Continuous Injection Type Steam Raw medium Expansion valve vacuum Holding section (where most of the sterilization takes place) Flash cooler - Direct steam injection for heating (relatively a rapid process) - Flash cooling (rapid process) Sterile medium R. Shanthini 25 Nov 2011

Continuous Sterilization: Continuous Injection Type Capital investment is low Easy to clean and maintain the system Heating and cooling periods are shorter Steam efficiency is very high as live steam is directly injected into the medium Direct contact of the steam with the medium makes it necessary that the steam should be clean and free of any anti-corrosive agents Foaming may occur during both heating and cooling R. Shanthini 25 Nov 2011

Continuous Sterilization: Continuous Heat Exchanger Type Sterile medium Steam Holding section Indirect steam heating in plate-and-frame (or shell-and-tube) heat exchanger Raw medium Cooling water R. Shanthini 25 Nov 2011

Continuous Sterilization: Continuous Heat Exchanger Type plate-and-frame heat exchanger has larger heat transfer area than shell-and-tube heat exchanger, and therefore more effective plate-and-frame heat exchanger is favourable with high viscous system plate-and-frame heat exchanger is limited to lower pressures (less than 20 atm) due to its weak structural strength R. Shanthini 25 Nov 2011

hold Continuous Sterilization: Most of the sterilization in the continuous sterilization process may occur in the holding section. Therefore no hold = ln = kd λhold = kd0 exp(-Ed/RT) λhold nt Since the holding section is a long pipe, length of the pipe L uav λ = hold average fluid velocity in the pipe R. Shanthini 25 Nov 2011

Continuous Sterilization: The ratio of average velocity to maximum velocity uav = 0.5 for laminar flow of Newtonian fluids through a smooth round pipe umax = 0.75 for turbulent flow = 0.87 for turbulent flow with the Reynolds Number of 1000,000 Therefore, using the average velocity to calculate the length of the pipe required for sterilization may leave some portion of the medium understerilized, which may cause contamination problem R. Shanthini 25 Nov 2011

Example 10.4: Estimating the time required for continuous sterilization A continuous sterilizer with a steam injector and a flash cooler will be employed to sterilize medium continuously with the flow rate of 2 m3/h. The time for heating and cooling is negligible with this type of sterilizer. The typical bacterial count of the medium is about 5 x 1012 per m3, which needs to be reduced to such an extent that only one organism can survive during two months of continuous operation. The sterilizer will be constructed with the pipe with an inner diameter of 0.102 m. Steam at 600 kPa (gauge pressure) is available to bring the sterilizer to an operating temperature of 125oC. For the heat resistant bacterial spores: kdo = 5.7 x 1039 per h; Ed = 2.834 x 105 kJ / kmol. For the medium: c = 4.187 kJ/kg.K; ρ = 1000 kg/m3; μ = 4 kg/m.h. a) What length should the pipe be in the sterilizer if you assume ideal plug flow? b) What length should the pipe be in the sterilizer if the effect of axial dispersion is considered? Assume an axial dispersion coefficient of 20 m2/h. R. Shanthini 25 Nov 2011

  kd dt = Solution to Example 10.4: Problem statement: The typical bacterial count of the medium is about 5 x 1012 per m3, which needs to be reduced to such an extent that only one organism can survive during two months of continuous operation. n0 = (5 x 1012 per m3) x (2 m3/h) x (24 h/day) x (60 days) = 14400 x 1012 nt = 1 = kd dt  t ln n0 nt = 144x1014  = ln = 37.2 1 The above integral should give 37.2. R. Shanthini 25 Nov 2011

hold Solution to Example 10.4: a) Since the temperature at the holding section in constant, hold = kd λhold = 37.2 For the given data, kd = kd0 exp(-Ed/RT) = (5.7 x 1039 per h) exp[- 2.834x105 / 8.314x(273.15+125)] = 375.3 per h Therefore, λhold = 37.2 / kd = 37.2 / 375.3 per h = 0.099 h Length of the pipe, L = velocity through the pipe x λhold = velocity through the pipe x 0.099 h R. Shanthini 25 Nov 2011

Since plug flow is assumed, velocity through the pipe = 2 m3/h Solution to Example 10.4: Since plug flow is assumed, velocity through the pipe = 2 m3/h = 245 m/h π (0.102/2)2 m2 Therefore, L = (245 m/h) x (0.099 h) = 24.26 m What happens if the flow is not plug flow? R. Shanthini 25 Nov 2011

Axial dispersion coefficient Solution to Example 10.4: b) If axial dispersion is considered, then we use the following table: uav L D Peclet number = nt n0 Axial dispersion coefficient kd L uav R. Shanthini 25 Nov 2011

is obtained from the table Solution to Example 10.4: uav L D (245 m/h) x ( L m) (20 m2/h) Peclet number = = kd L uav (375.3 per h) x ( L m) (245 m/h) X-coordinate = = nt n0 Y-coordinate = is obtained from the table R. Shanthini 25 Nov 2011

Solution to Example 10.4: If L = 25 m is tried, we get uav L D (245 m/h) x ( 25 m) (20 m2/h) Peclet number = = = 306 kd L uav (375.3 per h) x ( 25 m) (245 m/h) X-coordinate = = = 38.3 nt n0 Y-coordinate = = > 6.9 x 10-17 R. Shanthini 25 Nov 2011

Solution to Example 10.4: If L = 27.5 m is tried, we get uav L D (245 m/h) x ( 27.5 m) (20 m2/h) Peclet number = = = 337 kd L uav (375.3 per h) x ( 27.5 m) (245 m/h) X-coordinate = = = 42.1 nt n0 Y-coordinate = = > 6.9 x 10-17 R. Shanthini 25 Nov 2011

Filtration: Sterilize solutions that may be damaged or denatured by high temperatures or chemical agents. The pore size for filtering bacteria, yeasts, and fungi is in the range of 0.22-0.45 μm The pore size for filtering viruses and some large proteins is in the range of 0.01 μm R. Shanthini 25 Nov 2011

Methods for gas (air) sterilization: Aerobic fermentation require huge volumes of air (a 50,000 L fermenter requires 7x106 to 7x107 L per day of air) which must be sterilized. Adiabatic compression of process air can increase air temperature (150oC to 220oC). A temperature typically of 220oC for 30 s is required to kill spores. An air-filtration step is almost always used to ensure sterility of process air. Depth filters use glass wool, and rely on inertial impaction, interception, diffusion and electrostatic attraction (explained later). Surface filters using membrane cartridges use the sieving effect (explained later). R. Shanthini 25 Nov 2011

Filtration mechanisms operating in depth filters R. Shanthini 25 Nov 2011

Filtration mechanisms operating in depth filters Inertial impaction (or impingement) occurs when a particle travelling in the air stream and passing around a fibre, deviates from the air stream (due to particle inertia) and collides with the fibre. Impaction is the dominant collection mechanism for particles larger than 0.2 μm. It is important in removing bacteria. R. Shanthini 25 Nov 2011

Filtration mechanisms operating in depth filters Interception occurs when a large particle, because of its size, collides with a fibre in the filter that the air stream is passing through. Interception is the dominant collection mechanism for particles greater than 0.2 μm. It is important in removing bacteria. R. Shanthini 25 Nov 2011

Filtration mechanisms operating in depth filters Diffusion occurs when the random (Brownian) motion of a particle causes that particle to contact a fibre. Diffusion is dominant for particles less than 0.2 μm. It may be important for virus removal, but bacteria are sufficiently large that diffusion is relatively unimportant. R. Shanthini 25 Nov 2011

Filtration mechanisms operating in depth filters Electrostatic attraction plays a very minor role in mechanical filtration. After fibre contact is made, smaller particles are retained on the fibres by a weak electrostatic force. R. Shanthini 25 Nov 2011

Filtration mechanisms operating in surface filters R. Shanthini 25 Nov 2011

Concerns in air sterilization: Pressure drop is critical in a filter. Energy input for compressed air for a commercial-scale process is significant. Air treatment can account for 25% of total production costs. Design engineer has to balance the assurance sterility against the pressure drop. R. Shanthini 25 Nov 2011

180M3 Fermenter Plant Air Compressor R. Shanthini 25 Nov 2011 27

Air Filters in Fermentation Plant R. Shanthini 25 Nov 2011 28

Air sterilization note from Lee was handed over. R. Shanthini 25 Nov 2011 29