Double Beam spectrometer Provides a signal that is largely free of drift in the source and detector without requiring really expensive components Beam.

Slides:



Advertisements
Similar presentations
BL TIER 3 TIER 3 Identify suitable experimental procedures for measuring rates of reactions Identify the factors affecting the rate of a reaction Calculate.
Advertisements

Chemical Stoichiometry
Electromagnetic spectrum Visible range: = nm Ultra-violet: = nm Low energyHigh energy.
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Stoichiometry: Quantitative Information about chemical reactions.
AA and Atomic Fluorescence Spectroscopy Chapter 9
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Flame photometry.
Extraction of Nucleic Acids (Genomic DNA, mRNA and Plasmid DNA)
Advanced Spectroscopy 2. UV-VIS Spectroscopy. Revision 1.What are the wavelength ranges for the ultraviolet and visible regions of the spectrum?  UV:
 Amino acid analysis refers to the methodology used to determine the amino acid composition or content of proteins, peptides, and other pharmaceutical.
Glucose test Ms. Ibtisam alaswad Ms. Nour A. taim.
SPECTROPHOTOMETRY.
Spectrophotometry: An Analytical Tool. PGCC CHM 103 Sinex IoIo I Cell with Pathlength, b, containing solution light source detector blank where I o =
Electromagnetic spectrum Visible range: = nm Ultra-violet: = nm Low energyHigh energy.
Lecture 3b. Electronic Transitions Most molecules absorb electromagnetic radiation in the visible and/or the ultraviolet range The absorption of electromagnetic.
Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation.
Chapter 2 Quantitative.
Lecture 2b. Electromagnetic Spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
Introduction to Instrumental Analysis - Spectrophotometry
TITRATION This involves removing small samples from the reaction mixture at different times and then titrating the sample to determine the concentration.
Atomic Absorption Spectroscopy
Spectrophotometry August 2011 SLCC/UVU STEP grant workshop.
CHAPTER 12 ELECTRODE POTENTIALS AND THEIR APPLICATIONS TO XIDATION/REDUCTION TITRATIONS Introduction to Analytical Chemistry.
Titration Titration is the quantitative measurement of an analyte (the substance whose quantity or concentration is to be determined) in solution by completely.
ACID BASE TITRATION INDICATORS. Titration a method of analysis that will allow you to determine the precise endpoint of a reaction and therefore the precise.
Spectrophotometry: An Analytical Tool
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
Lecture 1 PRACTICE TEST Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
Less Manganese lost over C Manganese in Sea Water Excessive Background signal from NaCL Large loss of analyte.
Chapter 13 An Introduction to Ultraviolet- Visible Molecular Absorption Spectrometry.
1 Titration Curve of a Weak Base with a Strong Acid.
CHEMICAL ANALYSIS BY Dr.JAGADEESH. CHEMICAL ANALYSIS RESOLVING A SAMPLE IN TO ITS ULTIMATE COMPONENTS ( COMPOUNDS OR ELEMENTS)
Volumetric analysis 4th lecture.
Lecture 6c. Introduction Electromagnetic spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
Spectrophotometer.
Atomic-absorption spectroscopy
SPECTROPHOTOMETRY. Spectrophotometry Determines concentration of a substance in solution –Measures light absorbed by solution at a specific wavelength.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Ag+(aq) + 2 H2O(l)  Ag(H2O)2+(aq)
Biochemical instrumental analysis-14
Volumetric analysis. Mole concept map For the reaction A + B  C, where A is the limiting reagent, concentration particles mass volume (gas) MOLE (A)
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Laboratory Activity Two
Spectrophotometric Methods For Determination Of Proteins
1Chemistry 2C Lecture 20: May 17 th, )Introduction to Kinetics 2)Rate Laws 3)Orders and Reaction Constants 4)Initial Slopes 5)Zero th order reactions.
CLINICAL CHEMISTRY AUTO-ANALYZERS
ULTRAVIOLET AND VISIBLE SPECTROSCOPY
Estimation of quantity and quality of isolated DNA
THIN LAYER CHROMATOGRAPHY.
Environmental Chemistry Lesson # 2
Hardness What’s in your pipes?.
Volumetric analysis. Titration.
UV/VIS SPECTROSCOPY.
Simple Double Beam Spectrometer
Applications of UV-Vis Spectroscopy
Spectrophotometer Dr . S. Jayakumar.
Acid-Base Titration Titration is a chemical analysis involving the addition of a known concentration of titrant to a known volume but unknown concentration.
Spectrophotometry: An Analytical Tool
RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY.
Lecture 2b Beer’s Lambert Law.
Exp. Iron in Vitamin Tablet
VOLUMETRIC ANALYSIS B.Sc. Sneha S. Mule Assistant Professor
Colourimetry The absorption of light by a coloured solution is directly related to the concentration of the solution. Colourimetry determines the concentration.
A SEMINAR ON Ultraviolet-Visible Spectroscopy
Transition Metals (Cr, Mn, Fe, Co, Ni and Cu)
Clinical instrumental analysis
Presentation transcript:

Double Beam spectrometer Provides a signal that is largely free of drift in the source and detector without requiring really expensive components Beam alternates very fast between sample and reference cells. Don’t need to keep zeroing

Sample Cells Usually 1 cm pathlength Glass – visible Quartz – UV Plastic disposable – beware solvents 5 cm or 10 cm for dilute samples Smaller cells for small samples Flow through cells Temperature control Gas cells – longer Fibre optic probes

Fibre Optics Fibres of glass, usually about 120 µm in diameter.

Fibre Optic Probe

Derivative Spectroscopy Can determine flat maxima more precisely Isolate shoulders Distinguish weak signals from background

Photometric Titration Solution: 2 x M in Bi 3+ and Cu 2+ Titrant: EDTA At 745 nm, neither cation, nor reagent, absorbs Bi complex forms first – more stable – but doesn’t absorb The cu complex does absorb at 745 nm

Reaction rates Following enzyme kinetics Determine enzymes Determine substrates

Stop Flow Methods For fast reactions Two syringes driven at same rate Solutions flow into mixing chamber When plunger hits stop, measurement starts Generally measure initial rates of reactions

Absorbance ratios and differences Measure A at two Use A 1 /A 2 or A 1 – A 2 Plot versus concentration Use to asses purity of samples – to check just one component is present Eg ratio of A 260 nm : A 280 nm indicates how pure A sample of DNA you have.

Applications Metal ion analysis eg iron II or III React with ligands to get intense colours Reduce Fe III with hydroxylamine or hydroquinone etc Can extract the complexes into isoamyl alcohol for a cleanup/preconcentration step µg/mL are typical LOD’s

Organic/Biologicals Most common application Many absorb strongly May need to derivatize eg alcohol with phenyl isocyanate to give alkyl carbamates – 280 nm Free amino acids react with ninhydrin – blue/purple – 575 nm – aa analyzers

Automated clinical methods Many samples/hour Expensive to buy Can run many samples unattended

Centrifugal Analysis Combines robotic pipettors Centrifuge Spectrophotometer Computer Increases sample throughput Reduces volume of sample and reagents

Eliminates chemistry changeover time No set-up equilibrium time Used for water quality measurements Based on standard procedures Liquids are dispensed into separate compartments attached to the cuvettes Cuvettes are round a rotor. When rotor is spun, reagents are propelled into cuvettes. All reactions start together – good for kinetics

Samples and standards are mixed and run in parallel. Identical conditions are ensured for all cuvettes Can analyze 110 samples/hour Rotor spins at 2000 revolutions /min Get an average of ~ 7 readings/sample

Water Pollution Analysis Molybdenum blue method (NH 4 ) 3 P (Mo 3 O 10 ) 4 yellow Reduce with hydroquinone, Sn II or Fe II Get a polymer of Mo of different oxidation states Not stoichiometrically well-defined but is blue As, Si interfere – so they can also be determined this way

Air Pollution Analysis- SO 2 Collect by bubbling through 0.1 M sodium tetrachloromercurate HgCl SO 2 + 2H 2 O  Hg(SO 3 ) Cl - + 4H + Treat with formaldehyde and p-rosaniline to give red-violet colour 569 nm ppm by volume NO 2 interferes above 2 ppm

Advantages Visible Less interferences Often higher molar absorptivities