Towards a Pulseshape Simulation / Analysis Kevin Kröninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005.

Slides:



Advertisements
Similar presentations
MUSIC - Past, Presence, and Future of a detector concept Walter F.J. Müller, GSI Bormio 2004.
Advertisements

Agenda Semiconductor materials and their properties PN-junction diodes
C.Manfredotti, Quartu S.Elena, WOCSDICE 2001 GaAs IBIC analysis of gallium arsenide Schottky diodes C.Manfredotti 1,2, E.Vittone 1,2,F.Fizzotti.
General Characteristics of Gas Detectors
1 Chapter 5-1. PN-junction electrostatics You will also learn about: Poisson’s Equation Built-In Potential Depletion Approximation Step-Junction Solution.
Plasma Medicine in Vorpal Tech-X Workshop / ICOPS 2012, Edinburgh, UK 8-12 July, 2012 Alexandre Likhanskii Tech-X Corporation.
Solid State Detectors- 3 T. Bowcock 2 Schedule 1Position Sensors 2Principles of Operation of Solid State Detectors 3Techniques for High Performance Operation.
Advanced GAmma Tracking Array
New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
SmartPET: A Small Animal PET Demonstrator using HyperPure germanium Planar Detectors R. Cooper 1 st year PhD Student
Pulse Shape Analysis with Segmented Germanium Detector Xiang Liu, Max-Planck-Institut für Physik 1.Motivation 2.Pulse properties 3.Analysis procedure 4.Some.
GERDA: GERmanium Detector Array
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
Mark Rayner, Analysis workshop 4 September ‘08: Use of TOFs for Beam measurement & RF phasing, slide 1 Use of TOFs for Beam measurement & RF phasing Analysis.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
GERmanium Detector Array – a Search for Neutrinoless Double Beta Decay X. Liu - MPI für Physik, München Symposium – symmetries and phases in the universe,
Measurement of through-going particle momentum by means of Multiple Scattering with the T600 TPC Talk given by Antonio Jesús Melgarejo (Universidad de.
Temperature Dependence of the Crystal Properties of 18-fold Segmented HPGe Detector Allen Caldwell, Daniel Lenz, Jing Liu, Xiang Liu, Bela Majorovits,
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Irakli Chakaberia Final Examination April 28, 2014.
Task Group 2 Iris Abt, Michael Altmann, Kevin Kroeninger, Bela Majorovits, Franz Stelzer, Xiang Liu 1.Detector Development 2.Suspension & Cabling 3.MC.
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Flux Dependent Non-Linearity: The Evil Twin of Persistence Mike Regan, Kevin Lindsay, Eddie Bergeron, Rachel Anderson.
2016/6/4 Taka Kondo (KEK) 1 Issues of the SCT Digitization model 2 nd meeting of SCT Digitization TF Taka Kondo (KEK) 1.Current SCT digitization.
Chapter 4 Overview. Maxwell’s Equations Charge Distributions Volume charge density: Total Charge in a Volume Surface and Line Charge Densities.
Planned Transregional Collaborative Research Center TR27: Neutrinos and Beyond Project A4: Development of segmented germanium detectors for the investigation.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
Monte Carlo Studies on Possible Calibration Sources Kevin Kröninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005.
A full Monte Carlo simulation code for silicon strip detectors M. Brigida, C. Favuzzi, P. Fusco, F. Gargano, N. Giglietto, F. Giordano, F. Loparco, B.
 -tracking uses segmented detectors which are characterized by xTalk  Traces are modified in shape and amplitude  Energy effects: peak shifts and resolution.
Li HAN and Neal H. Clinthorne University of Michigan, Ann Arbor, MI, USA Performance comparison and system modeling of a Compton medical imaging system.
Using delay lines on a test station for the Muon Chambers Design considerations (A. F. Barbosa, Jul/2003)
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 In the figure: Photoelectric suppressed. Single Compton (effect of crystal dimensions).
3D Event reconstruction in ArgoNeuT Maddalena Antonello and Ornella Palamara 11 gennaio 20161M.Antonello - INFN, LNGS.
BACKGROUND REJECTION AND SENSITIVITY FOR NEW GENERATION Ge DETECTORS EXPERIMENTS. Héctor Gómez Maluenda University of Zaragoza (SPAIN)
Simulations of various aspects of the PPS Various members of the collaboration, to be enumerated later.
A. SarratTPC jamboree, Aachen, 14/03/07 1 Full Monte Carlo of a TPC equipped with Micromegas Antony Sarrat CEA Saclay, Dapnia Motivation Simulation content.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
1 LumiCal Optimization Simulations Iftach Sadeh Tel Aviv University Collaboration High precision design May 6 th 2008.
Optimization of planar pixel detector. T. Habermann Planar pixel detectors L W H ground U.
GERDA – a Search for Neutrinoless Double Beta Decay MPI für Physik, München Neutrinoless double beta decay and the GERDA experimentThe detector array and.
M.Altmann, GERDA Status Report SNOLAB Workshop IV, Investigating Neutrinoless Double Beta Decay Status of the GERDA Experiment Michael Altmann.
Giuseppe Ruggiero CERN Straw Chamber WG meeting 07/02/2011 Spectrometer Reconstruction: Pattern recognition and Efficiency 07/02/ G.Ruggiero - Spectrometer.
PMN07 Blaubeuren Segmented germanium detectors in 0νββ-decay experiments Kevin Kröninger (Max-Planck-Institut für Physik, München)
A. SarratILC TPC meeting, DESY, 15/02/06 Simulation Of a TPC For T2K Near Detector Using Geant 4 Antony Sarrat CEA Saclay, Dapnia.
Outline Description of the experimental setup Aim of this work TDC spectra analysis Tracking method steps Autocalibration Single tube resolution Summary.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
SIMULATION STUDIES ON THE EFFECT OF SF 6 IN THE RPC GAS MIXTURE Mohammed Salim, Aligarh Muslim University, INDIA Presented by Satyanarayana Bheesette,
Study of PC-HPGe detector for dark matter search CDEX collaboration Application of Germanium Detector in Fundamental Research Apr. 7-13,2013.
Towards pulse shape calculation and analysis for the GERDA experiment Kevin Kröninger, MPI für Physik International School of Nuclear Physics, Erice 2005.
What you need to design a detector: Principle of Field Calculation and Pulse Shape Simulation Jing Liu Kavli IPMU, University of Tokyo 8 Apr. 2013, Tuebingen.
Space Charge Effects and Induced Signals in Resistive Plate Chambers
An extension of Ramo's theorem to include resistive elements
GERDA Collaboration Meeting,
GLAST LAT tracker signal simulation and trigger timing study
Integration and alignment of ATLAS SCT
Pre-Test-stands at MPI Munich
Numerical simulations on single mask conical GEMs
p0 life time analysis: general method, updates and preliminary result
Ionization detectors ∆
GEANT Simulations and Track Reconstruction
Measurement of
Beam Test Results for the CMS Forward Pixel Detector
Numerical methods for modeling of electrophysical problems
Presentation transcript:

Towards a Pulseshape Simulation / Analysis Kevin Kröninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005

Outline Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005

SIMULATION

Simulation Overview I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005

Simulation Overview II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 What happens inside the crystal? Local energy depositions translate into the creation of electron-hole pairs with E dep : deposited enery E eh : 2.95 eV at 80 K in Ge E gap = 0.73 eV at 80 K ¾ of energy loss to phonons Corresponds to approximatly 600,000 e/h-pairs at 2 MeV Due to bias voltage electrons and holes drift towards electrodes (direction depends on charge and detector type) Charge carriers induce mirror charges at the electrodes while drifting = E dep / E eh SIGNAL

Drifting Field / Bias Voltage I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 In order to move charge carriers an electric field is needed Calculate field numerically: 3-D grid with spatial resolution of 0.5 mm Define Dirichlet boundary conditions (voltage, ground) depend on geometry (true coxial? non-true coxial? etc.) So far: no depletion regions, zero charge density inside crystal, no trapping Solve Poisson equation φ = 0 inside crystal using a Gauss-Seidel method with simultaneous overrelaxiation Need approximatly 1000 iterations to get stable field Electric field calculated as gradient of potential

Drifting Field / Bias Voltage II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005

Drifting Field / Bias Voltage III Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Example: non-true coaxial n-type detector

Drifting Process Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005

Mirror Charges – Ramos Theorem Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Ramos Theorem: Induced charge Q on electrode by point-like charge q is given by Calculation of weighting field: Set all space charges to zero potential Set electrode under investigation to unit potential Ground all other electrodes Solve Poisson equation for this setup (use numerical method explained) Q = - q · φ 0 (x) Q : induced charge q : moving pointlike charge φ 0 : weighting potential

Weighting Fields I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 x

Weighting Fields II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Example: true coaxial detector with 6 φ- and 3 z-segments (Slices in φ showing ρ-z plane) φ = 0°φ = 90° φ = 180° φ = 270° y x z

Preamp / DAQ Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Drift and mirror charges yield charge as function of time Preamp decreases accumulated charge exponentially, fold in gaussian transfer function with 35 ns width DAQ samples with 75 MHz time window 13.3 ns Example: (signal after drift, preamp and DAQ)(signal after drift)

Setups / Geometries / Eventdisplays I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Full simulation of non-true coaxial detector electrode core Charge Time Charge Current

Setups / Geometries / Eventdisplays II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005

Setups / Geometries / Eventdisplays III Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Full simulation of true-coxial 18-fold segmented detector Time Charge core electrodes

Analysis Approach

Pulseshape Analysis in MC: Spatial Resolution I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Is it possible to obtain spatial information of hits from pulseshapes? In principal YES! Risetime of signal (10% - 90% amplitude) is correlated with radius of hit due to different drift times of electrons and holes Relative amplitude of neighboring segments is correlated to angle Events with more than one hit in detector give ambiguities Studied in Monte Carlo with 2-D 6-fold segment detector, no DAQ, no sampling

Pulseshape Analysis in MC: Spatial Resolution II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Spatial information of radius and angle

Pulseshape Analysis: SSE/MSE Discrimination I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Do 0νββ signals differ from background signals? Background mainly photons that Compton-scatter: multiple hits in crystal Multisite events (MSE) Signal due to electrons with small mean free path: localized energy deposition Singlesite events (SSE) Expect two shoulders at most from SSE and more from MSE Count number of shoulders in current Apply mexican hat filter with integral 0 and different widths (IGEX method) Count number of shoulders: 2 : SSE >2 : MSE

Pulseshape Analysis: SSE/MSE Discrimination II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005

Pulseshape Analysis: SSE/MSE Discrimination III Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Fraction of SSE and MSE for different filter widths Separation of SSE/MSE in principle possible, combine with information from neighboring segments Identified as SSE Identified as MSE SSE MSE Filter width Fraction of Events

Data to Monte Carlo Comparison

Data to Monte Carlo Comparison I Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Data from teststand (see X. Liu) Later on used for SSE selection Source

Data to Monte Carlo Comparison II Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Teststand data vs. Monte Carlo Energy [MeV] General agreement No finetuning yet Next: pulseshapes without any additional selection criteria

Data to Monte Carlo Comparison III Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Comparison of pulseshapes Charge Data Monte Carlo

Data to Monte Carlo Comparison IV Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Comparison of pulseshapes Current Data Monte Carlo

Data to Monte Carlo Comparison V Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Comparison of pulseshapes Current Charge

Data to Monte Carlo Comparison VI Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Comparison of pulseshapes Charge amplitude Current amplitude

Data to Monte Carlo Comparison VII Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 Comparison of pulseshapes Risetime [ns]

Conclusion Kevin Kröninger, MPI München GERDA Collaboration MeetingDUBNA, 06/27 – 06/29/2005 First approach towards a simulation of pulseshapes Different geometries / fields available Package available and linked to MaGe Pulseshape analysis to further reduce background via SSE/MSE identification is feasible need sampling rate as large as possible (1 GHz 1 ns possible?) Data to Monte Carlo comparison using teststand data yields coarse agreement finetune parameters of simulation