D. Passarelli, M. Merio, L. Ristori, B. Wands March 13, 2012

Slides:



Advertisements
Similar presentations
T4. DESIGN OF TIMBER COLUMN (axial compression) T4. Design of timber column page 1. Timber framed building Floor plan Section Example: Checking column.
Advertisements

Design should address: UNDERSTRENGTH OVERLOAD
Cryomodule Helium Volumes Tom Peterson, Fermilab AWLC14 13 May 2014.
SPL Intercavity support Conceptual design review 04/11/ A. Vande Craen TE/MSC-CMI.
TOPIC 1.3 RESPONSE OF CIVIL ENGINEERING PROJECT
N. Dhanaraj, Y. Orlov, R. Wands Thermal-Stress Analysis of CC1 Space Frame.
Buckling in aircraft structures
1 CONSTRAINT CORRECTED FRACTURE MECHANICS IN STRUCTURAL INTEGRITY ASSESSMENT Application to a failure of a steel bridge Anssi Laukkanen, Kim Wallin Safir.
D. Passarelli, M. Merio, L. Ristori, B. Wands March 29, 2012
LECTURE SERIES on STRUCTURAL OPTIMIZATION Thanh X. Nguyen Structural Mechanics Division National University of Civil Engineering
1st Hungarian-Ukrainian Joint Conference on SAFETY-RELIABILITY AND RISK OF ENGINEERING PLANTS AND COMPONENTS” BAY-LOGI 1 Fatigue calculations on benchmark.
Progress on the MICE 201 MHz Cavity Design Steve Virostek Lawrence Berkeley National Lab RF Working Group Fermilab August 22, 2007  automatic.
Unit 3: Solid mechanics An Introduction to Mechanical Engineering: Part Two Solid mechanics Learning summary By the end of this chapter you should have.
FE calculations for the bolted helium vessel May 6th 2015
An Investigation into the use of FEA methods for the prediction of Thermal Stress Ratcheting Huse, Stephen.
Luca Dassa – 23/02/ / 8 CRAB cavities meeting Preload Bolt size (1) Shear load: 602 N (p=0.26 MPa) -> Min preload: 2006 with Static friction coefficient:
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
Cryomodule Concept for the ODU RF Dipole Crab Cavity Tom Nicol* - Fermilab December 10, 2013 * With lots of help from HyeKyoung, Tom J, Shrikant, Ofelia,
Technical University of Łódź Department of Strength of Material and Structures M.Kotelko, Z. Kołakowski, R.J. Mania LOAD-BEARING CAPACITY OF THIN-WALLED.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
SSR1 Tuner studies (work in progress) 1 L. Ristori – 29 Nov 2011 With slides from I. Gonin, M. Hassan and D. Passarelli.
FAILURE INVESTIGATION OF UNDERGROUND DISTANT HEATING PIPELINE
Fermilab requirements and recent FEA Analyses PH-DT Engineering Office, CERN 06/05/2015 Page 1 CERN, May 6th 2015.
Page 1 Jean Delayen HyeKyoung Park Center for Accelerator Science Department of Physics, Old Dominion University and Thomas Jefferson National Accelerator.
An Investigation into the use of FEA methods for the prediction of Thermal Stress Ratcheting Huse, Stephen.
LINEAR BUCKLING ANALYSIS
Stress and cool-down analysis of the cryomodule Yun He MLC external review October 03, 2012.
Work toward Stainless Steel SRF Helium Vessels at Fermilab Tom Peterson (presenter), Information from Jeff Brandt, Serena Barbanotti, Harry Carter, Sergei.
Chapter 4 Axial Load. Saint -Venant's Principle Saint-Venant's Principle claims that localized effects caused by any load acting on a body will dissipate.
Stress and Cool-down Analysis Yun HE MLC Internal Review 9/5/2012Yun HE, MLC Internal Review1.
SPOKE TUNER STATUS M. Merio, D. Passarelli, L. Ristori.
Analysis of Microphonics in SSR1 for Project-X M. Hassan, D. Passarelli, I. Gonin, S. Barbanotti, L. Ristori, and S. Yakovlev 9/27/2011 PXIE Meeting.
Status of Activities at CERN
56 MHz SRF Cavity Thermal Analysis and Vacuum Chamber Strength C. Pai
4/19/ Helium tank comparison Nicola Panzeri INFN – Mi LASA.
1Matthias LiepeAugust 2, 2007 Future Options Matthias Liepe.
56 MHz SRF Cavity and Helium vessel Design
Alignment and assembling of the cryomodule Yun He, James Sears, Matthias Liepe.
Review of Cavity Load Cases and relevant analysis L. Dassa and C. Zanoni feat. N. Kuder 08/02/2016.
HiLumi-LHC/LARP Crab Cavity System External Review – May Work partly supported by the EU FP7 HiLumi LHC grant agreement No and by the.
☻ ☻ ☻ ☻ 2.0 Bending of Beams sx 2.1 Revision – Bending Moments
1 BROOKHAVEN SCIENCE ASSOCIATES CWRF 2010 Murali Yeddulla and Jim Rose Modification of the CESR-B cavity for low Q-ext.
Warm cryostat mechanical calculations A.Catinaccio PH-DT Engineering Office, CERN Page 1 CERN, May 27th 2015.
EC3 VERIFICATION SCIAENG® EC3 VERIFICATION SCIAENG® SPECIAL THANKS TO ALL INVOLVED D. ALVAREZ FEITO J.C. BATISTA LOPES C. BAULT O. BELTRAMELLO A.CATINACCIO.
Design Process 1.Selection of the type of structural form to be used and the material out of which the structure is to be made. 2.Determination of the.
Gravity load on SAS – comparison between real and mock-up April 13 th, 2016.
Adam Carreon July 19, 2012 Technical Division SRF Department Dressed SSR1 Cavities.
LCLS-II Prototype Cryomodule Vacuum Vessel and HGRP Tom Peterson 4 December 2014 Design Review.
CW Cryomodules for Project X Yuriy Orlov, Tom Nicol, and Tom Peterson Cryomodules for Project X, 14 June 2013Page 1.
Ralf Eichhorn CLASSE, Cornell University. I will not talk about: Cavities (Nick and Sam did this) HOM absorbers (did that yesterday) Power couplers (see.
Comments from the SNS Cryostat Design Review February 2010 Tom Peterson, Fermilab 15 February 2010.
14-Jun-161 Status of Horizontal Test Stand (HTS-2) Development Efforts Pradeep Kush, Prashant Khare, RRCAT, India Team Members: S.Gilankar, Rupul Ghosh,
Low Beta Cryomodule Development at Fermilab Tom Nicol March 2, 2011.
Spoke section of the ESS linac: - the Spoke cryomodules - the cryogenic distribution system P. DUTHIL (CNRS-IN2P3 IPN Orsay / Division Accélérateurs) on.
Development of Cryo-Module Test Stand (CMTS) for Fermi Lab (R.L.Suthar, Head,CDM, BARC) Cryo-Module Test stand (CMTS) is a very sophisticated equipment.
Engineering Design of Raon SC Cavities Myung Ook Hyun SCL Team Myung Ook Hyun SCL Team.
Cryomodule Safety Approvals Jay Theilacker LCLS-II Production Cryomodule Final Design Review May 12-14, 2015.
LCLS-II 3 rd Harmonic Dressed Cavity Design Review Chuck Grimm November 20, 2015.
PIP-II SSR1 Cryomodule Technical Issues Leonardo Ristori TTC Meeting
Pipe Integrity Check using Finite Element Analysis
Buckling in aircraft structures
Stress and cool-down analysis of the cryomodule
Preliminary analysis for the dressed LHC RF cavity (2) April 28th 2016 – EDMS L. Dassa, L. Mettler.
Crab Cavity HOM Coupler Specification Drawings & Tolerances
Fredrik Fors Mechanical Engineering, JLab 09/29/2016
Date of download: 12/27/2017 Copyright © ASME. All rights reserved.
CENF - LBNF cryostat Relevant safety codes
Date of download: 1/22/2018 Copyright © ASME. All rights reserved.
Designing and Manufacturing of a hand operated plastic injection moulding machine envisioned for the mesoscale range. Freddy Travieso
Strucural fire design of steel elements
Presentation transcript:

D. Passarelli, M. Merio, L. Ristori, B. Wands March 13, 2012 Technical Division SRF Department ASME design on SSR1 G3 2010 ASME Boiler and Pressure Code section VIII, Division 2 – Part 5 Design by analysis methodology Material properties Design Load parameter Protection against plastic collapse “Coarse” results Protection against collapse from buckling Protection against local failure Protection against failure from cyclic loading D. Passarelli, M. Merio, L. Ristori, B. Wands March 13, 2012

Conceptual Design of dressed SSR1 SRF cavity with Tuner Transition ring (under developing) Bellows Helium Vessel SS316L Cavity Nb Lever Tuner 𝑘 𝑐𝑎𝑣 =25 𝑘𝑁 𝑚𝑚 𝑑𝑓 𝑑𝑙 =540 𝑘𝐻𝑧 𝑚𝑚 𝑑𝑓 𝑑𝑝 ≈0 ±10 𝐻𝑧 𝑡𝑜𝑟𝑟 𝑑𝑓 𝑑𝑝 =−0.7 𝑑 𝐵𝑃 +4.9 Brazed-joint: Beam pipes Coupler port Side ring http://www-bdnew.fnal.gov/pxie/SRF/Meetings/2012/SSR1%20Tuner%20concept.pdf

2010 ASME Boiler and Pressure Code VIII Division 2 – Part 5 According to the ES&H Fermilab manual, the Cavity and Helium Vessel can be considered a pressure vessel and it must comply with the “2010 ASME Boiler and Pressure Vessel Code”. Among the various options provided by the code, we decided to follow the Design-by-Analysis methodology described in the “2010 ASME Boiler and Pressure Vessel Code section VIII, Division 2 – Part 5”. Division 1: formulas, simple shape, typically thicker walls Division 2: complex shape, FEM analysis Requirement: achieve the desired Maximum Allowable Working Pressure (MAWP) 𝑀𝐴𝑊𝑃≥2 𝑏𝑎𝑟 at room temperature (293K) 𝑀𝐴𝑊𝑃≥4 𝑏𝑎𝑟 at cryogenic temperature (2K)

2010 ASME Boiler and Pressure Code VIII Division 2 – Part 5 The Design-by-Analysis methodology utilizes the results from finite element analysis to assure: Protection against plastic collapse avoid unbounded displacement in each cross-section of the structure due to the plastic hinge Elastic stress analysis method Elastic-plastic stress analysis method Protection against collapse from buckling buckling is characterized by a sudden failure of a structural member subjected to high compressive stress, where the actual compressive stress at the point of failure is less than the ultimate compressive stresses that the material is capable of withstanding. Elastic-plastic stress analysis Protection against local failure (i.e. joints) Elastic analysis Elastic-plastic analysis Protection against failure from cyclic loading Elastic ratcheting analysis method

Material properties The main parts of the Helium Vessel and Cavity are made in SS316L and Niobium, respectively. To describe the material model required to perform the different kind of analysis, by finite element software, the following mechanical and thermal properties for both materials are needed. Mechanical properties (at 293K and at 2K): Linear Elastic properties (E, ν) elastic-plastic curve Niobium by FESHM Chapter 5031.6 - Dressed Niobium SRF Cavity Pressure Safety.pdf and ER10163-SRF_Cavities_Spec SS316L by “2010 ASME Boiler and Pressure Vessel Code section II, Part D” Thermal properties: coefficient thermal expansion (CTE) curve from 293K to 2K.

Design Load parameter SSR1 load conditions The relevant loads acting on the SSR1 dressed cavity are: “P” pressure in the helium space under fault condition “Ps“ static head from liquid Helium “D” dead weight of the system “T” cooldown from 293K to 2K “T” controlled axial displacement of 0.25mm at the Beam Pipe (“tuning” operation) For each analysis the code provides the load combination and factored load cases

Design-by-Analysis Scheme MAWP ≥2 𝑏𝑎𝑟 at 293K ≥4 𝑏𝑎𝑟 at 2K Protection against collapse from buckling Elastic plastic stress analysis method Protection against failure from ratcheting Elastic stress analysis method Protection against plastic collapse Elastic stress analysis method Load combination P+Ps+D → material prop @ 293K Condition to satisfy: 𝜎 𝑒𝑞 ≤S Elastic plastic stress analysis method Global Criteria_1 2.4(P+Ps+D) → material prop @ 293K Global Criteria_2 2.1(P+Ps+D+T) → material prop @ 2K Condition to satisfy: Convergence of the analysis Result Map of critical zones on the model “Coarse” result MAWP @ 293K: 2.2bar @ 2K: 3 bar (TbC) Protection against local failure

Protection against plastic collapse Elastic stress analysis - @ 293K and 2bar Elastic material property @ T=293K Load combination applied: P+Ps+D P = 2 bar Refined mesh Condition to satisfy: 𝜎 𝑒𝑞 ≤S 𝑆 𝑁𝑏 =25 𝑀𝑃𝑎 𝑆 𝑆𝑆316𝐿 =100 𝑀𝑃𝑎 200 MPa 50 MPa Away from the point of singularities the stresses are under the limit

Protection against plastic collapse Elastic stress analysis - @ 4K and 4 bar Elastic material property @ T=4K Load combination applied: P+Ps+D P = 4 bar Refined mesh Condition to satisfy: 𝜎 𝑒𝑞 ≤S 𝑆 𝑁𝑏 =200 𝑀𝑃𝑎 𝑆 𝑆𝑆316𝐿 =390 𝑀𝑃𝑎 200 MPa 390 MPa Away from the point of singularities the stresses are under the limit

Protection against plastic collapse Elastic plastic stress analysis - @ 293K Elastic plastic material property @ T=293K Load combination applied: 2.4(P+Ps+D) “Coarse” mesh Pressure of last solution………5.35bar 𝑀𝐴𝑊𝑃 = 5.35 2.4 =2.23𝑏𝑎𝑟

Simulation under study Protection against plastic collapse Elastic plastic stress analysis - @ 4K Elastic plastic material property @ T=4K Load combination applied: 2.1(P+Ps+D+T) “Coarse” mesh Pressure of last solution………6.3bar 𝑀𝐴𝑊𝑃 = 6.3 2.1 =3𝑏𝑎𝑟 (not finalized results) Simulation under study

Conclusion We have defined a procedure to check the mechanical performances of the dressed SSR1 cavity in agreement with “ES&H Fermilab manual” and “2010 ASME Boiler and Pressure Vessel Code”. The simulations to assure the protection against plastic collapse are running and the first “coarse” results are encouraging. In 15 days we should be able to show more finalized results. THANKS!