G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb. 2009 1 THE LHCb EXPERIENCE WITH THE ASSEMBLY OF THE GEM (*) G. Bencivenni LNF - INFN Italy.

Slides:



Advertisements
Similar presentations
Davide Piccolo INFN Napoli Muon Annul Review Cern 15 September 2003 Chamber Production QA/QC MUON ANNUAL REVIEW On RESISTIVE PLATE CHMABERS CERN, 15 September.
Advertisements

Muon EDR: Chamber design M2/3 R1/2 16/04/20031T.Schneider/LHCb Muon EDR 1.General description - AW read out -Cathode pad read out -HV supply 2.Details.
Status Update on Mechanical Prototype in Rome November 6,
Christine KOURKOUMELIS University of Athens ATLAS Muon Chamber construction in Greece and alignment studies for H  ZZ  4μ decay Como, 8/10/03.
PRODUCTION and CERTIFICATION of Multi Wires Proportional Chambers for the LHCb Muon System at CERN K.Mair for the LHCb Muon Group CERN* Poster anlässlich.
F. Murtas LNF/INFN 9 July 2002 GEM Chamber 20x24 cm 2 Status Report F.Murtas for the GEM group  20x24 Prototype  PSI Test Beam  Module 0 Progress 
Davide Piccolo - INFN NapoliSIENA maggio 2004 Production and Quality control of RPCs for the CMS muon barrel system Davide Piccolo – INFN Napoli.
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
Don Lynch 9/15/05 HBD Safety Review 1 Mechanical Design And Installation Hadron Blind Detector (HBD) Don Lynch.
Nilanga Liyanage University of Virginia UVa GEM Team Dr. Kondo Gnanvo, Dr. Vladimir Nelyubin, Kiadtisak Saenboonruang, Chao Gu, Xinzhan Bai, Jie Liu, Seth.
June 8-th 2004W.Baldini1 Ferrara production center Ferrara production center Production Readiness Review OverviewOfOperations P R R.
GEM detectors activity
Introduction to GEM detectors assembly Leszek Ropelewski CERN CompassTotem 33 cm NA61 30 cm 20 cm 66 cm Totem Upgrade 10 cm.
1 SBS Spectrometer / GEP5 Conf.. 2 Tracking Requirements Requirements Tracking Technology DriftMPGDSilicon High Rate: MHz/cm 2 (Front Tracker)
G. Martellotti CERN 22/04/20021 Tooling / Test Stations for MWPC (Meeting LNF, Roma1/Pz ) Production rate : 408 chambers (Fe + LNF) :192 R4 M1.
Sept. 24, Status of GEM DHCAL Jae Yu For GEM-TGEM/DHCAL Group Sept. 24, 2010 CALICE Collaboration Meeting Univ. Hassan II, Casablanca Introduction.
M.Alfonsi 1, G. Bencivenni 1, W. Bonivento 2,A.Cardini 2,C. Deplano 2, P. de Simone 1, F.Murtas 1, D.Pinci 3, M. Poli-Lener 1, D. Raspino 2 and B.Saitta.
G.Bencivenni LNF/INFNMuon Meeting 21-October-2002 Status Report on triple-GEM detector M.Alfonsi 1, G. Bencivenni 1, W. Bonivento 2,A.Cardini 2,C. Deplano.
1 July GEM R&D Activity in USTC Yi Zhou University of Science & Technology of China.
Status of KLOE-2 Inner Tracker JOINT-GEM meeting Helsinki 15 July 2010 G.Bencivenni.
M. Alfonsi LNF/INFN Cagliari 5 May 2006 M1R1 mechanical requirements  Space constraint Frame and pannel Pads readout and trigger sectors Gas inlet and.
Tariq J. Solaija, NCP Forward RPC EDR, Tariq Solaija Forward RPC EDR The Standard RPC for low  regions Tariq J. Solaija National Centre for.
First results of an aging test of a full scale MWPC prototype for the LHCb muon system Workshop on “Aging Phenomena in Gaseous Detectors”, October 2-5.
Siena, 24 th May 2004 Aging Measurements on Triple-GEM detectors operated with CF4-based gas mixtures M. Alfonsi 1, G. Bencivenni 1, W. Bonivento 2, A.Cardini.
The Bigbite second GEM tracker. SBS GEM Trackers Front Tracker Geometry x6 18 modules In Italy  50 cm x 40 cm Modules are assembled to form larger chambers.
Status of production at LNF E. Dane, C. Forti, D. Pinci, A. Sarti – LHCb Muon CERN 25-may-04 Monday 24-may: closed chamber 30. Will close 2 more this week.
MWPC sandwich panels C.Forti INFN-LNF / LHCb-MUON EDR CERN 16 th April sandwich panels typologies of cathodes the mould the production procedure.
Chamber construction Construction Tools Production sites Assembly Sequence (“travelers”) Manpower P. Campana LNF – LHCb Muon EDR Cern April 16 th, 2003.
GEM R&D Update Kondo Gnanvo. Outline  GEM R&D and assembly facilities at UVa  Cosmic test results  Update on the 40 × 50 cm 2 GEM prototype  Plans.
F.Murtas1IMAGEM DDG GEM technology for X-ray and Gamma imaging IMAGEM l Detector setup l First results on X-ray imaging l First results on Gamma ray imaging.
16/04/20031PNPI / LHCb Muon EDR Wire Pad Chambers PNPI design for regions R4 in Stations M2,M3,M4  4 gas gaps of 5mm±70µm;  Active area: 1224x252.8 mm².
Preliminary results of a detailed study on the discharge probability for a triple-GEM detector at PSI G. Bencivenni, A. Cardini, P. de Simone, F. Murtas.
LNF activities on WPC Panels Construction of prototypes and layout Status of tooling Proto 0, open items, plan,...
M. Bianco On behalf of the ATLAS Collaboration
1 HBD update Itzhak Tserruya DC Upgrades meeting, January 14, 2005 NIM paper II: Generic R&D ~ completed Full scale prototype construction Pending issues.
14-Dec-15S.Movchan Straw manufacturing and QC1 Straw manufacturing procedure and QC tape and straw parameters specification conditions of straw production:
F.Murtas1 CNAO- ARDENT Workshop October 19 th 2012 Triple GEM detectors : Beam monitoring for beam profile and intensity measurements. Construction of.
Plans for MPGD Radiation hardness tests for full detectors and components Matteo Alfonsi,Gabriele Croci, Elena Rocco, Serge Duarte Pinto, Leszek Ropelewski.
Production Readiness Review at PNPI Chamber assembling: Main production and quality control steps 30 January 2004 – G.Alkhazov 1.Input components control.
Status of the Cylindrical‐GEM project for the KLOE‐2 Inner Tracker Danilo Domenici (INFN-LNF) on behalf of the KLOE-2 collaboration Villa Olmo, Como –
Muon Meeting April 2004JsG Status of Chambers Production at CERN Jean-Sebastien Graulich o Open Questions from the PRR O-ring Aging, Aging tests, Storage.
Chamber Quality Control Before the construction several checks are performed on:  Panels (cathode and pad PCB)  GEM foil Tests on assembled detector.
F.Murtas1 LUMI GEM Bremsstrahlung Dafne Bhabha Dafne Upgrade.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
10/7/2003Thomas Schneider1 Status report of CERN/PNPI Tooling support for PNPI M2R2 Prototype Plans towards the PRR.
To measure 0, mechanical oscillations of the wire to be tested are induced by applying a periodic high voltage (about 900 V) with a frequency of 300 ÷
M23 Inner Regions Upgrade with Triple-GEM detectors The EVLGG (Davide, Gianni & Ale) INFN Cagliari LNF Frascati INFN Roma.
February 14, Comprehensive Review B. Schmidt Outline: Status and overview of activities: –Platforms and staircases –Muon Filters and beam plugs.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
M23 Inner Regions Upgrade with Triple-GEM detectors The XVLGG (Davide, Gianni & Ale) INFN Cagliari LNF Frascati INFN Roma.
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
Zaragoza, 5 Julyl Construction of and experience with a 2.4 x 1 m² micromegas chambers Givi Sekhniaidze On behalf of the Micromegas community.
CMS Upgrade Workshop, FNAL, Oct 28-30, O.Prokofiev Update ME4/2 Chambers and Tooling A construction of new ME4/2 prototype at CERN Factory tooling,
11/02/2005M. Alfonsi - LNF1 DETECTOR CONSTRUCTION M. Alfonsi - LNF.
The interaction of the Laboratori Nazionali di Frascati– INFN with TE-MPE-EM Workshop G. Bencivenni LNF-INFN Frascati - Italy.
Results on a Large Area triple-GEM Detector at LNF 5 th RD51 Collaboration Meeting Freiburg, 25 May 2010 D. Domenici - LNF.
T2 GEM Production in Helsinki Kari Kurvinen TOTEM T2 EDR meeting Radiation Detector Laboratory of Helsinki Institute of Physics (HIP) and Department.
GEM detectors activity at the Laboratori Nazionali di Frascati INFN G.BencivenniLNF-INFN.
A High Eta Forward Muon Trigger & Tracking detector for CMS A High Eta Forward Muon Trigger & Tracking detector for CMS Archana Sharma For CMS High Eta.
(On Behalf of CMS Muon Group)
Activity of CERN and LNF Groups on Large Area GEM Detectors
Dept. of Physics and Space Sciences, Florida Institute of Technology
Laboratori Nazionali di Frascati
Quality Control Chamber Production
Production ad Quality control of RPCs for the CMS muon barrel system
Triple GEM detectors : measurements of stray neutron.
LABORATORI NAZIONALI DI FRASCATI
Pre-installation Tests of the LHCb Muon Chambers
(On Behalf of CMS Muon Group)
Presentation transcript:

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb THE LHCb EXPERIENCE WITH THE ASSEMBLY OF THE GEM (*) G. Bencivenni LNF - INFN Italy (*) Work done in collaboration with the INFN-Cagliari

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb OUTLINE  Introduction  Construction of GEMs in LHCb  Quality Controls in LHCb  Beyond LHCb: large area GEMs  Assembly training session schedule

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb INTRODUCTION

4 All stations are equipped with small gap MWPCs with the exception of M1R1 sector (area ~ 1 m 2 ), that is instrumented with triple-GEM detectors. About 20% of triggered muons will come from M1R1. M1R1 is placed in front of the calorimeters and very close to the beam pipe, so that low material budget, high rate capability and radiation tolerant detectors are required. LHCb apparatus Muon system: L0 high p T trigger + offline μ - ID The LHCb GEM detector in M1R1 CP in B-meson system B 0 d  J/  +K 0 S B 0 S  J/  +  B0S +-B0S +-

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb LHCb GEM detectors in M1R1: requirements (1) Rate Capability up to ~ 1 MHz/cm 2 Station Efficiency > 96% in a 20 ns time window (*) Cluster Size < 1.2 for a 10x25 mm 2 pad size Radiation Hardness 1.6 C/cm 2 in 10 years (**) Chamber active area 20x24 cm 2 (*) A station is made of two detectors “in OR”. This improves time resolution and provides some redundancy (**) Estimated with 50 e - /particle at 184 kHz/cm 2 with a gain of ~ 6000

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Main tasks & solutions found (R&D):  improvement of the time resolution:  gas mixture: Ar/CO 2 /CF 4 =45/15/40, kV/cm, 5.5 i.p./mm;  detector geometry: 3/1/2/1 mm gap size; - first transfer gap smaller to reduce bi-GEM effect; - Induction gap smaller to increase signal current (I =- q/ t =- q w d /x )  good gain uniformity and safe operation mode:  detector mechanical tolerances (*):  gap(  100 μ m)   E gap (E)   G eff (  6%)  choice of the material (**): aging/etching (CF 4 )  epoxy glue, gas inserts …  GEMs voltage choice(***): V G1  V G2  V G3 to reduce discharge probability (but also bi-GEM effect)  GEM segmentation: 80cm 2 /sector to reduce damages in case of discharge LHCb GEM detectors in M1R1: requirements (2) (***) Bencivenni et al., “Performance of a triple-GEM detector for high rate charged particle triggering”, NIM A 494 (2002) 156 (**) P. de Simone et al., “Studies of etching effects on triple-GEM detectors operated with CF4-based gas mixtures”, IEEE Trans. Nucl. Sci. 52 (2005) 2872 (*) M.Poli Lener, “The Triple-GEM detectors for M1R1 at the LHCb experiment”, PHd thesis,

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Triple-Gem R&D for LHCb (2000 – 2002) 10x10 cm 2 GEM foil stretched and glued on frames. The triple-GEM prototype is assembled inside a gas tight box. Prototypes were equipped with FEE based on VTX-KLOE chip. The first GEM stretcher for 10x10cm 2 GEM foil (2000)

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Construction of GEMs in LHCb

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb CLEAN ROOM 2. GEM HV TEST 1. FRAME CLEANING 4. GEM CUTTING 3. GEM STRETCHING 5. ASSEMBLY 6. SOLDERING All construction operations are performed in a class 1000 clean room. Operators must be specifically dressed (gloves, over-shoes, masks...) CLEAN ROOM

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb A remind of the chamber structure The detector is composed by: - 3 GEM foils glued on FR4 frames, defining the gaps and then sandwiched between - cathode and anode PCBs, glued on honeycomb structure panels. A M1R1 detector is realized coupling two of such chambers. The main construction steps are:  GEM framing  Chamber assembly  Coupling of the two chambers

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb GEM FRAMING: frame preparation In the clean room further cleaning is performed by means of an ultrasonic bath. Then frames are dried in a oven at 40°C for about 24 h. The internal edge of the frame is preliminary sanded (outside the clean room). The frame is cleaned before entering in the clean room, and finally checked for broken fibers. A clean cabinet is used for the storage of frames.

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb GEMs that pass the HV test (see quality controls) are stretched with a specific tool. The foil is clamped with jaws equipped with plastic O-rings. Mechanical tension (18kg/jaw  20 MPa, inside the elastic limit), applied to the edge of the foil, is monitored with gauge meters. Kapton creep is negligible for this mechanical tension (see 18 cm 200 mm 240 mm GEM FRAMING: stretching

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb GEM FRAMING: glueing Before glueing the frame is checked again for broken fibers, cleaned with isopropyl- alchool and dried with nitrogen flow. Araldite 2012 epoxy resin (good electrical behavior, suitable handling properties & aging/etching tested(*)) is applied with a dispenser and distributed with a rolling wheel tool on the frame. Epoxy work life: 4 minutes; curing time: 2 hours. Then the frame is coupled with the stretched GEM foil, with a load of at least 60 kg. All gluing operations have been performed at a controlled temperature of about o C. Stretching and glueing require for two operators and last about minutes to be accomplished. (*) P. de Simone et al., “Studies of etching effects on triple-GEM detectors operated with CF4-based gas mixtures”, IEEE Trans. Nucl. Sci. 52 (2005) 2872

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb GEM FRAMING: refining Exceeding Kapton is cut to size. During this operation the HV connections of the GEM foil are suitable masked. HV connection to sectors, of the segmented side of the GEM foil, is provided through SMD limiting resistors (1M  ). These are soldered inside the slots machined in the frame. During this operation the active area of the GEM is protected. HV test (see quality controls) is performed again at this stage.

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb CHAMBER ASSEMBLY (I) For the chamber assembly we use the epoxy araldite AY103 + HD991 (good electrical behaviour, convenient handling properties & well-known aging properties (*)) One after the other the 3mm, 1mm, 2mm framed GEMs, plus an additional bare 1mm-frame (defining the induction gap), are positioned and glued on the cathode PCB panel. The assembly operation is performed on a machined ALCOA reference plane, equipped with 4 reference pins. (*) C. Altunbas et al., CERN-EP/ ; CERN PH-TA1-GS, systems.web.cern.ch

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb CHAMBER ASSEMBLY (II) Finally readout anode pad panel is glued, and over the whole structure a load of kg is “uniformly” applied for 24h, as required for epoxy polymerization. Globally the assembly procedure requires for two operators and last about 2 working hours. All gluing operations have been performed at a controlled temperature of about o C, to avoid humidity trapping problems. At the end HV connections of GEM foils are soldered on the cathode PCB. The 7 HV cables will be successively soldered on the internal side of the PCB

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb CHAMBER SEALING Inside the four reference holes, used for the positioning of the various components during the assembly, Stesalite bushings are inserted and glued with the CIBA 2012 epoxy. Bushings prevent gas leaks from the corners of the chamber and are used to hang-up the chamber on the muon wall. Small leaks (see quality control) can be fixed with additional glue (AY103 + HD991). Dow Corning conformal coating (very good dielectric rigidity), is used for the passivation of the HV connections on the cathode. Curing time: 24h Chamber is then ready for the X-ray test (see quality controls)

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb DETECTOR INTEGRATION Two chambers, passing the QCs, are coupled with the cathodes faced one to each other  CARDIAC-GEM boards are installed along the detector perimeter.  On the HV side, HV filters together with a rad-hard Radiall® HV connector are plugged on the corresponding cathode panel through the 7 HV pins, in the space located behind the FEE boards HV pins GND filter HV filters CARIOCA-GEM FEE LV & LVDS card  Low voltage and LVDS signal distribution board is laid on the detector back-plane

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb All detectors have been moved to CERN in July In the storage site they are kept under nitrogen flux, waiting for the installation on the apparatus, foreseen in spring 2009 Gain  4000 Average noise rate per channel (Hz) Fully integrated detectors at CERN FEE boards installed on the detectors have been selected on the basis of noise rate. The resulting average noise rate per channel is few Hz, even at threshold as low as 2.5 fC.

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Chamber Quality Controls Checks before the chamber construction:  Panels (cathode and pad PCB)  GEM foils visual inspection  GEM foil HV test Tests on assembled detector:  Gas chamber leakage  Gain uniformity with X-ray

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Checks on panels All panels were checked for planarity with a 3-D machine at LNF. The measure was performed on a grid of 35 points. The planarity requirement ≤ 50 µm 3-D machine Preliminary measurements have been done on the panel pre-production resulting better than 30 µm

GEM foil HV test: conditioning (I) All GEM foils have been tested before the frame gluing in order to check their quality. The test, sector by sector, was performed in a gas tight box. The voltage to each GEM sector is applied through a 500 M  limiting resistor in order to avoid GEM damages in case of discharges. N 2 Flow The gas tight plexiglass box is flushed for about 1 hour with nitrogen in order to reduce the humidity < 5%, before the GEM test humidity probe HV supply R= 500 M 

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb GEM foil HV test: conditioning (II) Voltage is applied on each sector (18 voltage steps): 1.50 V/step up to 400 V (  20 s/step) 2.25 V/step up to 500 V (  1 min/step) V/step up to 600V (  2 min/step) acceptance requirements: leakage current < 1nA AND # of discharges <3 The GEM sector pass the step Yes the voltage ramp-up on the sector is suspended and the test is repeated later No Test duration for one GEM foil  3 hours (30’ per sector)

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb This procedure has been tuned on a pre-production of 11 GEM foils GEM foil HV test: conditioning (III) The average number of discharges per sector on the whole procedure comes out to be. If the test is repeated a second time, the total number of discharges goes down to. This behaviour could be due to microscopic dust softly burned with high voltage and then removed from the GEM surfaces by N 2 flow. Number of discharges 1 st HV tour 2 nd HV tour Histograms are filled with the total number of discharges occurred in each sector during ramp-up (18 HV steps).

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Ambient parameters (T and P) are monitored with additional sensors Gas leak test (I): system set-up Both test and reference chambers are inflated in parallel, up to an overpressure of  5 mbar. The difference between  P(S1) e  P(S2) measures the gas leak rate of the test chamber Test duration  2 hours foam box for thermal insulation N2N2 Ref chamber S1S2 T, P Chamber to test P atm The gas leak rate measurement of a chamber is generally referred to that one of a reference chamber (same volume, “no leak” defined as <<1mbar/day) in order to take into account for atmospheric pressure and temperature variations.

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Gas leak test (II) A gas leak rate of ~1 mbar/day corresponds to a residual humidity ~ 50 ppm V for a 80 cc/min gas flow. All chambers exhibit a gas leak of the order of few mbar/day <1 mbar/day Time (min) T/p (°K /mbar )  p (mbar) Chambers “reference chamber”

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Collimator with 5 mm diameter X-ray test(I): system setup The mapping of the gain, pad by pad, was performed with a high intensity X-ray tube Gas humidity and temperature are monitored with a probe mounted on the gas line outlet. Atmospheric pressure is also recorded. X-Y plane moved with step-motors Test duration: 16 hours

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Chambers gain uniformity < 10% (without edge effects  6% ) X-ray test(II): measurements The current signal induced on the single pad is read-out with a current- meter (nA sensibility) and it is corrected for T and p variations. Edge effects due to effective beam spot in the border pads

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Beyond LHCb: design of a large area GEM In the framework of the R&D on the Cylindrical-GEM (CGEM) for the KLOE experiment upgrade we are going to build a large area planar GEM (30x70 cm 2 active area), with the aim to test the quality/ homogenity of the large GEM produced with the new single mask technique (by Rui)

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb Beyond LHCb: the large stretching tool A very large stretching tool has been designed. The frame gluing will be performed by using the “vacuum bag” technique, tested in the construction of the CGEM With the usual 1 kg/cm, finite element simulation indicates a maximum gravitational/electrostatic sag of the order of 20 μm

G.Bencivenni LNF-INFN, GEM Training Session – CERN, 16, Feb GEM detector assembly training session TUESDAY 17th FEBRUARY 9:00 – 10:30 Frascati/Cagliari GEM 1 stretching and glueing 15:30 – 17:00 Frascati/Cagliari GEM 2 stretching and glueing WEDNESDAY 18th FEBRUARY 10:30 – 12:00 Frascati/Cagliari GEM 3 stretching and glueing 15:30 – 18:00 Frascati/Cagliari detector final assembly Under the supervision of our technician, Marco PISTILLI, who built all the LNF GEM chambers for the LHCb experiment, we will show the main construction phases of a Triple-GEM. All the operations will be not done in a clean room due to logistics problems.