IR filter wheel UVIS filter wheel (one of twelve) Characterization Tests of WFC3 Filters S. Baggett 1, R. Boucarut 2, R. Telfer 3, J. Kim Quijano 1, M.

Slides:



Advertisements
Similar presentations
Feb 16, 2006TIPS – S.Baggett1 Sylvia Baggett (STScI) Ray Boucarut (GSFC) GSFC Randal Telfer Manuel Quijada Petar Arsenovic Morgan Dailey Randy Kimble Jeff.
Advertisements

James Webb Space Telescope Optical Telescope Element (OTE) Mirror Coatings Ritva. A. Keski-Kuha, Charles W. Bowers, Manuel A. Quijada NASA/Goddard Space.
May 19, 2009JWST Partner's Workshop1 NIRCam Status Marcia Rieke University of Arizona JWST Partner’s Workshop Ottawa, Canada May 19, 2009 JWST-PRES
ARCTIC Post-PDR Optical Design Study
The Second Generation of IR detectors for WFC3 Massimo Robberto European Space Agency and Space Telescope Science Institute.
Return to Hubble: Servicing Mission 4 Dr. Frank Summers Space Telescope Science Institute April 2, 2009.
Optical Astronomy Imaging Chain: Telescopes & CCDs.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS Science Calibration & Instrument Status TIPS 20 Nov 2003 Last COS TIPS Aug 2003.
VLBI: Visible Light Broadband Imager Instrument Conceptual Design Presentation Tom Berger Lockheed Martin Solar and Astrophysics Lab.
Page 1HMI Team Meeting – January 26, 2005 HMI Mission Operations Rock Bush HMI Stanford Program Manager Stanford University
Photo courtesy NOAO, taken with LBNL fully depleted CCD Optical Characterization of 1.7  m NIR Detectors for SNAP M. Brown (Michigan), J. Balleza (IDTL),
Applications of SPCE to Pharmaceutical Research Kathleen Hamilton, Tom Laue, and James Harper Presentation at the 2007 BITC Meeting University of New Hampshire.
Astronomical Spectroscopy
9 March 2004 GIFTS Blackbody Subsystem Critical Design Review Emissivity Modeling and Uncertainty Budget 09 March 2004.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Apr 17-22, Tunable filter wavelength scan and calibration of intensity ripple Y. Katsukawa (NAOJ) and SOT team.
STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)
Oct 17, 2001SALT PFIS Preliminary Design Review Optical Integration and Test Plan 1 Southern African Large Telescope Prime Focus Imaging Spectrograph Optical.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA TIPS / COS TV Update 21 December 2006 Agenda Agenda Testing Setup and Status Testing Setup.
Cosmic Origins Spectrograph Hubble Space Telescope James C. Green University of Colorado Cosmic Origins Spectrograph Instrument Design and Capabilities.
High Resolution Echelle Spectrograph for Chinese Weihai 1m Telescope. Leiwang, Yongtian Zhu, Zhongwen Hu Nanjing institute of Astronomical Optics Technology.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA COS Status FUV Detector “1-bounce design” NUV Detector HST aberration fully-corrected Calibration.
Herschel Space ObservatoryPACS Science Verification ReviewMPE 22/23 June 2006 GJ / MPE 1 PACS Test Facility Capabilities – Cryogenics and OGSE Gerd Jakob.
A Search for Earth-size Planets Borucki – Page 1 Roger Hunter (Ames Research Center) & Kepler Team March 26, 2010.
Science with the new HST after SM4 WFC3 slitless spectroscopy Harald Kuntschner Martin Kümmel, Jeremy R. Walsh (ST-ECF) WFC3-team at STScI and NASA.
1 Wide Field Camera 3 Monthly Status ReviewJuly 17, 2007 WFC3 TIPS July 19, 2007.
PACS SVR 22/23 June 2006 PACS FPU Subunits1 FM FPU Subunits A. Poglitsch.
Figure 8.Color map of the geometric correction along the dispersion axis for segment A. Figure 4. Measured distortions for all PSA positions for segment.
CDE CDR, September 14, 2004 Your Position, Your Name 1 GATS AIM Science Team Meeting January 23-24, 2007 CIPS Calibration Review, Aimee Merkel, Bill McClintock.
TIPS/JIM1 The “Happy Bunny:” Characterizing Long- Wavelength Fringing in WFC3/UVIS Mike Wong INS/WFC3 Visiting Scientist.
HST Cal Conf -- Oct 27, 2005 Calibration Status and Results for Wide Field Camera 3 – R. Kimble/GSFC, Calibration Status and Results.
Observing Strategies at cm wavelengths Making good decisions Jessica Chapman Synthesis Workshop May 2003.
SNAP Calibration Program Steps to Spectrophotometric Calibration The SNAP (Supernova / Acceleration Probe) mission’s primary science.
1 WIYN One Degree Imager. 2 Filter Changer 3 Demonstration Filters  Sloan g’ r’ and i’ delivered from Infinite Optics  Johnson U on order from Barr.
March 18, 2004Tips – Olivia Lupie1 WFC3 Filter Testing, Modeling, Designing Ghosts (spurious reflections) in some UVIS filters were discovered during first.
1 TIPS May 17, 2007 WFC3 Ambient Calibration #2 Results H. Bushouse.
Jan 15, 2004WFC3 TIPS – John W. MacKenty1 WFC3 TIPS Presentation January 15, 2004 Optical Stimulus.
Solar orbiter_______________________________________________.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA SMOV4 Requirements Review Cosmic Origins Spectrograph Scott D. Friedman STScI 30 July 2003.
The Second Generation of IR detectors for WFC3 Massimo Robberto European Space Agency and Space Telescope Science Institute.
ZTF Optics Design ZTF Technical Meeting 1.
14FEB2005/KWCAE2-UsersGroup Astro-E2 X-Ray Telescopes XRT Setup & Structure Performance Characteristics –Effective Area –Angular Resolution –Optical Axes.
11-Jun-04 1 Joseph Hora & the IRAC instrument team Harvard-Smithsonian Center for Astrophysics The Infrared Array Camera (IRAC) on the Spitzer Space Telescope.
Extended Detector Cutoff Considerations WFIRST Project Office May
Click to Change Title Here is a text box to present information in paragraph format, instead of bulleted lists. We’ve left space to the right for an image.
WFPC2 Filters after 16 Years on Orbit P. L. Lim 1, M. Quijada 2, S. Baggett 1, J. Biretta 1, J. MacKenty 1, R. Boucarut 2, S. Rice 2, & J. del Hoyo 2 STScI.
WFC3 SMOV Report for TIPS 16 July 2009 John MacKenty This presentation contains material that is embargoed until after the SM4 ERO press conference. Images/spectra.
Introduction NICMOS (Near-Infrared Camera and Multi-Object Spectroscopy) was installed on the Hubble Space Telescope during SM2 in 1997 and has been the.
AERONET DRAGON Campaign, Summer 2011 Christina Justice College Park Scholars – Science & Global Change Program Environmental Science and Policy
1 WFC3 – Critical Science Review Science Driven CEIs Requirements.
May 22, 2003WFC3 Report at the June 03 TIPS1 Optical alignment and image quality testing at GSFC Test lead: Bill Eichorn, GSFC Test conductors: George.
GSFC/Spinhirne 03/13/2002 Multispectral and Stereo Infrared Cloud Observations by COVIR (Compact Visible and Infrared Imaging Radiometer) J. Spinhirne,
STScI Calibration Workshop1 Fringing in the WFC3/UVIS detector Mike Wong UC Berkeley.
PACS IIDR 01/02 Mar 2001 Optical System Design1 N. Geis MPE.
HST Cal Conf -- Oct 27, Calibration Status and Results for Wide Field Camera 3 – R. Kimble/GSFC, Calibration Status and Results.
1 CLARREO Advances in Reflected Solar Spectra Calibration Accuracy K. Thome 1, N. Fox 2, G. Kopp 3, J. McCorkel 1, P. Pilewskie 3 1 NASA/Goddard Space.
LIGO-G v1 Inside LIGO LIGO1 Betsy Weaver, GariLynn Billingsely and Travis Sadecki 2016 – 02 – 23 at CSIRO, Lindfield.
Pre-launch Characteristics and Calibration
TEMPO Instrument Update
Onboard Instruments of ASTROSAT
Single Object & Time Series Spectroscopy with JWST NIRCam
30-Nov-2006 Jean-Marc Defise - CSL
WFC3 STUC 18 November 2004 Optical Stimulus.
Summary Single Object & Time Series Spectroscopy Jeff Valenti JWST Mission Scientist Space Telescope Science Institute.
Intra-pixel Sensitivity Testing Preliminary Design Review
What Is Spectral Imaging? An Introduction
Detective Quantum Efficiency Preliminary Design Review
Launch and On-orbit Checkout
Igor Appel Alexander Kokhanovsky
Optics Alan Title, HMI-LMSAL Lead,
Presentation transcript:

IR filter wheel UVIS filter wheel (one of twelve) Characterization Tests of WFC3 Filters S. Baggett 1, R. Boucarut 2, R. Telfer 3, J. Kim Quijano 1, M. Quijada 2, P. Arsenovic 2, T. Brown 1, M. Dailey 2, D. Figer 1, G. Hartig, B. Hilbert 1, R. Kimble 2, O. Lupie 1, J. MacKenty 1, T. Madison, M. Robberto 1, S. Rice 2, J. Shu 2, J. Townsend 2 1. Space Telescope Science Institute 2. NASA/Goddard Space Flight Center 3. Orbital Sciences Corp., NASA/Goddard Space Flight Center ABSTRACT The WFC3 instrument to be installed on HST during the next servicing mission consists of a UVIS and an IR channel. Each channel is allocated its own complement of filters: 48 elements for the UVIS (42 filters, 5 quads, and 1 UV grism) and 17 slots for the IR (15 filters and 2 grisms). While a majority of the UVIS filters exhibit excellent performance consistent with or exceeding expectations, a subset show significant filter ghosts. Procurement of improved replacement filters is in progress and a summary of the characterization tests being performed on the new filters is presented. In the IR channel, while no filter ghosting was detected in any of the filters during thermal vacuum testing, the grisms were found to be installed incorrectly; they have been removed and will be reinstalled. In addition, due to the significantly improved response blueward of 800nm expected in the new substrate-removed IR detector (see Invited talk by R.A.Kimble), two IR filters originally constructed on a fused silica substrate are being remade using an IR grade substrate to block any visible light transmission. Tests of the new IR filters and preparations for the grism reinstallation are summarized. For more information about WFC3: Inspection Imaging Spectral scans Receipt of filter from vendor Receipt of filter from vendor Flatfield images Environmental tests Results discussed; SOC/STScI/GSFC choose flight/spare Results discussed; SOC/STScI/GSFC choose flight/spare Analysis by filter team Filter Characterization Testflow Vendor Tests Comprehensive checks are performed by the manufacturer prior to shipment of the filter to the customer. These tests verify the filter’s compliance with the specifications and the robustness of the filter coating. Key items measured on the candidate flight pieces include the spectral throughput (primary bandpass as well as out of band blocking), transmissive wavefront (on uncoated substrate as well as the coated filter), and quality control (check of length, width, thickness, inspection for scratches and cosmetic defects, painting of any pinholes, and cleaning). Characteristics such as the coating integrity (adhesion quality, resistance to abrasions, temperature and humidity cycling) and radiation hardness are performed on witness or flight-like pieces. Inspection Upon receipt of the filter from the vendor, a detailed inspection is performed. The dimensions of the filter are confirmed and the item is inspected for any blemishes or coating defects. Photographs, both front and backlit, are taken to document the condition of filter and map any pinholes which may be present. Imaging Extensive point source imaging is done with each filter; tests are performed using white (either xenon or deuterium lamp) as well as monochromatic ( nm) light. These data allow for measurement of filter ghosts (strength, appearance, and behavior), as well as wavefront, wedge, and focus shift. Figure 7 shows the lab setup. Figure 2 shows a whitelight image of a candidate F689M filter. The image was taken at a relatively high filter tilt angle; this moves the ghost away from the PSF and facilitates measurement of the ghost level. The setup ghost is an artifact of the lab setup and appears even without a filter in the beam. Images are taken at a variety of tilt angles and translation positions as well as in configurations simulating seventeen points distributed across the WFC3 field of view. Figure 3 presents a monochromatic scan of the ghosts measured in a candidate filter. Note: the fairly high ghost intensities shown occur out of band, where the filter blocking is significant; integrated over a continuum source, the relative ghost strengths are much lower. The monochromatic results are used to constrain the model, which in turn is used to predict ghost behavior as a function of target spectral type. Figure 4 illustrates images from a phase retrieval dataset. Focus sweeps are obtained through a 9x9 array of 10mm apertures covering the filter, separated by steps of 5mm. Wavefront data taken without a filter are subtracted, including focus and tilt, yielding wavefront error, focus shift, and wedge. Spectral Scans The spectral throughput of the filter is measured both in and out of band using a PerkinElmer 950. Scans are taken at multiple points to allow an assessment of uniformity. In-band UVIS scans are performed in a 5x5 grid across the filter while out of band UVIS scans are executed in the center of the filter and at the four corners. Figures 8 and 9 illustrate typical in and out of band scans which are evaluated in light of the input specifications. Imaging tests are performed using FilterGEISt (filter ghost evaluation imaging station), a dedicated lab setup which reproduces the WFC3 UVIS + HST optical parameters. A 4-axis stage assembly provides repeatable translation/rotation motions as well as simulations of sources within the WFC3 FOV. Mirror Filter Camera Aperture Stage assembly Figure 7. FilterGEISt Figure nm, no filter606 nm, through F606W-310 Environmental Tests Witnesses and non-flight pieces are subjected to temperature cycling under thermal vacuum (TV) conditions in order to verify the robustness of the coatings. Baseline inspections, spectral scans, and flatfields are taken prior to the test. The cycles are designed to mimic the TV conditions the filters are expected to experience during ground testing and on-orbit. After the cycles, another round of inspections, spectral scans, and flatfields are taken to check for any evidence of coating degradation. Flatfield images The fine scale transmission properties of the filter are verified via flatfielding. The imaging setup is designed to simulate that of the WFC3 internal calibration system (divergent beam). The entire filter is covered, to check for blemishes, coating degradation, or any other anomalies that may be present. Figure 1. F280N pinhole image IR filter testing No filter ghosts were found in the IR filters during instrument-level testing but two filters – originally constructed on fused silica because the QE of the original IR detector was low in the blue - must be remade on an IR- transmitting color glass IR80. The change is driven by the new IR detectors under development, which are being thinned to reduce particle-induced luminescence in the CdZnTe substrate; the new detectors will have significant QE well blueward of 800nm. The IR replacement filters will undergo a full set of characterization tests, including spectral scans at a variety of locations on the filter as well as at two temperatures (room temperature and nominal operating temperature of -30C). Given the relatively small filter size (25.4mm in diameter for IR, 53.2mm square for UVIS), the in-band IR scans are performed at 5 points and the out of band scans at filter center, as illustrated in Figures 10 and 11. An IR InGaAS IR array camera will be incorporated into the FilterGEISt lab setup, in order to measure wavefront, wedge, and perform a ghost check. Finally, the two IR grisms which were installed incorrectly have been removed and will be reinstalled in the upcoming year. One of the grisms is being remade with an improved red edge in order to reduce the transmission of thermal background radiation, which led to an undesirably high background on the detector in thermal vacuum testing. Filter Selection The final choice of which, if any, replacement filters to fly resides with the WFC3 Science Oversight Committee, with analysis inputs from the STScI and GSFC WFC3 teams. The decision is based upon a careful weighing of the characterization test results for the new filters versus the characteristics of the current flight filters as determined from previous filter tests as well as instrument-level ambient and thermal vacuum tests. Figure 10. In-band scan of F125W Figure 11. Out of band scan of F125W Figure 8. In-band scan of F410M candidate Figure 9. Blocking in F467M candidate Replacement Filters The UV is a critical part of WFC3’s bandpass coverage; Figure 5 summarizes the new UV replacement filter bandpasses. In most cases, the filter development technology now available has provided increased throughput in addition to reducing the ghost levels. For example, in F225W (which showed the most improvement) the ghost levels are reduced from ~15% to <0.3% and the new filter grasp (integral of the filter and WFC3 transmission over wavelength in the primary bandpass) is ~30% more than the original flight filter. Ghost levels in the visible filters have been reduced as well (some even eliminated) and again, in most cases the grasp of the new filter is higher than in the old filter. Figure 6 provides a comparison of the bandpasses of the original and new visible filters. Figure 5. Best Candidate UV Filters Figure 6. Visible Filters Filter ghost Figure 2. F689M-311, whitelight Setup ghost Filter ghost Figure 4. Phase Retrieval Images + spec spec + spec