Chapter 25 Instruments for Optical Spectrometry

Slides:



Advertisements
Similar presentations
Chapter 25 Instruments for Optical Spectroscopy
Advertisements

An introduction to Ultraviolet/Visible Absorption Spectroscopy
Spectrophotometry Basics Adapted from Basic Laboratory Methods for Biotechnology by Lisa Seidman and Cynthia Moore.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chapter 7 Components of Optical Instruments
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
What disperses radiation into component wavelengths?
Chem. 133 – 3/19 Lecture. Announcements I Lab –Term Project Proposal due today –Lab Report Set 1 Period 2 due today –Next Lab Report due 4/7 Following.
1 Components of Optical Instruments, Cont… Lecture 6.
 PART Absorption Spectrometer Dr. S. M. Condren SourceWavelength SelectorDetector Signal Processor Readout Sample.
Atomic Absorption Spectroscopy Prof Dr Hisham E Abdellatef 2011.
Components of Optical Instruments or What’s inside that spectrometer?
Molecular Fluorescence Spectroscopy
1 Molecular Luminescence Spectroscopy Lecture 31.
Chapter 7 Components of Optical Instruments. Typical spectroscopic instruments contain five components: (1) a stable source of radiant energy, (2) a transparent.
Chem. 133 – 4/1 Lecture. Announcements I Lab –Returning Term Project Proposals (I expect to be getting boxes of supplies ready) –Returning Set 2 Period.
Chem. 133 – 3/17 Lecture. Announcements Pass back HW + Quiz Lab –Term Project Proposal due Thursday –Next Lab Report also due Thursday Today’s Lecture.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Essential Components of a UV-vis Spectrophotometer Monochromator Signal Processor Display Source Sample Transducer.
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry Absorption measurements based upon ultraviolet and visible radiation.
UV–Vis Molecular Absorption Spectrometry Chapter 13.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
Components of Optical Instruments, Cont… Lecture 8.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
Principles of instrumentation Prepared by: Ibtisam H. AlAswad Reham S. Hammad.
Chapter 10 Atomic Emission Spectrometry
Atomic Emission Spectrometry By: Alexa Kunch
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
Simple Double Beam Spectrometer
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Spectrophotometry.
Introduction to Spectrochemical Methods
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Colorimeters or photometers
Chapter 3 Components of optical instruments
Spectrophotometer.
Spectroscopic Analysis Part 3 – Spectroscopy Experiments Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water Studies Centre School.
Molecular Luminescence Spectroscopy
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Photometry.
Chapter 10 Atomic Emission Spectrometry
Fluorometric determination of riboflavin
Chem. 133 – 3/29 Lecture. Announcements I Grading – Set 2 lab reports (return?) – Term project proposals (still working on) – UV-Visible seemed to work.
Instruments for Optical Spectrometry
Instrumental Analysis
hn1 hn2 optical l selector source sample detector signal processor
Principles of instrumentation. Photometry - Photometry means “the measurement of light” If a substance can be converted to a soluble, colored material,
Chem. 133 – 3/16 Lecture.
UV/VIS SPECTROSCOPY.
Components of Optical Instruments
Chem. 133 – 3/14 Lecture.
Optical Characterization Techniques
Spectrophotometer - Visible Type Spectro - photometer consists of two instruments : Spectrometer   Photometer  Spectrometer   for producing light.
Colorimeters or photometers
Spectrophotometer Dr . S. Jayakumar.
Chapter 3. Components of Optical Instruments
Measurements involving light –A Basic Principles and Instrumentation
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Satish Pradhan Dnyanasadhana College, Thane
Instrumental Analysis
Colorimeters OR photometers
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Instrumentation for UV and visible absorption
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Chapter 25 Instruments for Optical Spectrometry

Instrument Components Contents in Chapter 25 Instrument Components Basic Components of Spectroscopic Instrumentation 1) Sources of Energy 2) Wavelength Selector 3) Sample Holder 4) Detectors 5) Signal Processors 3. UV/visible Photometers and Spectrophotometers Figures of merit: 品質指標

1. Instrument Components 1) Most spectroscopic instruments in the UV/visible and IR regions are made up of five components: (1) Sources of Energy (2) Wavelength Selector (3) Sample Holder (4) Detectors (5) Signal Processors Figures of merit: 品質指標

Glossary Filter 濾光鏡 Interference filter 干涉濾鏡 Absorption filter 吸收濾鏡 Monochromator 單光儀 Grating 光柵 Prism 稜鏡 Slit 狹縫 Bandwidth 頻寬 Interferometer 干涉計 Fourier Transform (FT) 傅立葉轉換 Time domain 時域 Frequency domain 頻域

2) Conceptual Block Diagram of Spectrometer ***** (1) For absorption measurement Light Source Wavelength selector Detector Signal processor and readout Sample (2) For emission measurement Sample Wavelength selector Detector Signal processor and readout Thermal

(3) For fluorescence measurement Light Source Wavelength selector Sample Wavelength selector Signal processor and readout Detector (4) For chemiluminescence measurement Sample + Reagent Wavelength selector Signal processor and readout Detector

2. Basic Components of Spectroscopic Instrumentation 1) Sources of Energy For absorption and scattering spectroscopy: Energy is supplied by photons (electromagnetic radiation). For emission and luminescence spectroscopy: Thermal, radiant (photon), or chemical energy to promote the analyte higher energy state. (1) Light (Electromagnetic Radiation) Sources: Continuum source: A source emits radiation over a wide range of wavelengths. Line sources: A source emit radiation at selected wavelength ranges.

(cont’d) Electrodeless discharge lamp line source in UV/Vis atomic absorption

(cont’d) (2) Thermal Energy (for emission spectrometer): e.g., flames and plasmas. Flame: (fuel/oxidant, e.g., acetylene/air), achieve temperatures of 2000–3400 K. Plasmas: (ionized gases, e.g., Ar), temperatures of 6000–10,000 K. (3) Chemical Sources of Energy: e.g., in chemiluminescence, the analyte is raised to a higher-energy state by means of a chemical reaction, emitting characteristic radiation when it returns to a lower-energy state.

2) Wavelength Selector Effective bandwidth Effective bandwidth: The bandwidth of a monochromator or and interference filter at which the transmittance is 50% of that at nominal wavelength. Narrow slit decrease s the effective bandwidth, also diminishes the throughput of radiation. For qualitative purpose, narrow slit increase the spectra resolution. For quantitative purpose, wilder slit provide greater reproducibility.

(cont’d) (1) Filter: A wavelength selector that uses either absorption, or constructive and destructive interference to control the range of selected wavelengths. a) Interference filter b) Absorption filter Type Interference filter Absorption filter Theory use constructive and destructive interference to isolate a narrow range of wavelengths. Colored glass or a dye suspended in gelatin, which removes the complementary color Effective bandwidths 10–20 nm 30–250 nm. Maximum throughputs > 40%. 10%

Interference Filters Consists of a transparent dielectric that occupies the space between two semitransparent metallic films. All of this is sandwiched between glass or other transparent materials. If the distance traveled by the reflected beam from 1 is some multiple of the wavelength, then reinforcement will occur at point 2. The nominal wavelength for an interference filter λmax is given by the equation: max = 2t/n t is the thickness of the central fluoride η is its refractive index n is an integer called the interference order.

(2) Monochromator: A wavelength selector that uses a diffraction grating or prism, and that allows for a continuous variation of the nominal wavelength. a) Diffraction grating b) Prism

Components of a Monochromator A polychromatic radiation is converted to a monochromatic radiation of finite effective bandwidth. A scanning monochromator includes a drive mechanism, allowing successive wavelengths to exit from the monochromator. Focusing mirror Collimating mirror grating prism

Dispersion of radiation

Reflection Grating A reflective surface is grooved or blazed giving numerous faces for reflection to occur, beam 2 travels a longer distance than beam 1. If the extra distance traveled is a multiple of the wavelength, then constructive interference will occur. The angle of reflection r is related to the wavelength of the incoming radiation by the equation n = d(sin i + sin r)

(3) Polychromator: A wavelength selector in which different directions of the dispersed light (by prism or diffraction grating), simultaneously detected by a multi-detector (e.g., photodiode array, PDA)

(cont’d) Polychromator Photodiode array (PDA): A linear array of photodiodes providing the ability to detect simultaneously radiation at several wavelengths.

(4) Interferometer Interferometer: A device that allows all wavelengths of light to be measured simultaneously. The signal shows a function of the moving mirror’s position. The result is called an interferogram, or a time domain spectrum. The time domain spectrum is converted by Fourier Transform, to the normal spectrum (also called a frequency domain spectrum). Fourier transform IR spectrometers have the advantages over dispersive instruments of higher speed and sensitivity, better light-gathering power, more accurate and precise wavelength settings, simpler mechanical design, and elimination of stray light and IR emission.

3) Sample Holder/Matrix (1) Feasibility of cuvette materials Sample containers, which are usually called cells or cuvettes, must have windows that are transparent in the spectral region of interest.

(2) Feasibility of preparation solvent

4) Detectors Modern detectors use a sensitive transducer to convert a signal consisting of photons into an easily measured electrical signal. Ideally the detector’s signal (S): S = kP + D P: electromagnetic radiation’s power k: detector’s sensitivity D is the detector’s dark current Dark current: The background current present in a photon detector in the absence of radiation from the source.

Characteristics of transducers for optical spectroscopy Charge-injection device (CID) detector: The voltage change arising from movement of the charge from the region under one electrode to the region under the other is measured. Charge-coupled device (CCD) detector: The charge is moved to a charge-sensing amplifier for measurement.

5) Signal Processor Signal processor A device, such as a meter or computer, that displays the signal from the transducer in a form that is easily interpreted by the analyst. Examples: analog meters, digital meters, recorders, and computers. Additionally, signal processor may be used to calibrate the detector’s response, to amplify the signal from the detector, to remove noise by filtering, or to mathematically transform the signal.

3. UV/visible Photometers and Spectrophotometers Classification Spectrometer: A spectroscopic instrument that uses a monochromator or polychromator in conjunction with a transducer to convert the radiant intensities into electrical signals. Spectrophotometer: The spectrometer that allows measurement of the ratio of the radiant powers of two beams, a requirement to measure absorbance. Photometer: A spectroscopic instrument that uses a filter for wavelength selection in conjunction with a suitable radiation transducer.

2) Single beam versus Double beam (1) Single beam instrument (2) Double beam instrument

3) Instrumentation for Fluorescence (1) Fluorometer: an instrument for measuring fluorescence that uses filters to select the excitation and emission wavelengths. (2) Spectrofluorometer: an instrument for measuring fluorescence that uses a monochromator to select the excitation and emission wavelengths.

Practice Q1. The reciprocal of wavelength is called: (A) Amplitude (B) Wavenumber (C) Frequency (D) Period A1. (B) Q2. Photomultiplier is a: (A) Photon transducers (B) Thermal transducers (C) Absorption filter (D) Interferometer A2. (A) Q3. Which of followings are used for wavelength selection: (A) Filter (B) Monochromator (C) Interferometer (D) Tungsten lamp A3. (A)(B)(C)

Homework End of Chapter 25 Skoog 9th edition, Chapter 25 Questions and Problems 25-6 25-13 25-18 25-19 End of Chapter 25