1 An Introduction to the Storage Bridge Bay Specification.

Slides:



Advertisements
Similar presentations
© 2005 DataCore Software Corp DataCore SANmelody 2.0 IP/SAN FC/SAN Application Support Services Harness the full power and capabilities of SANmelody! Note:
Advertisements

PowerEdge T20 Customer Presentation. Product overview Customer benefits Use cases Summary PowerEdge T20 Overview 2 PowerEdge T20 mini tower server.
PowerEdge T20 Channel NDA presentation Dell Confidential – NDA Required.
Confidential Prepared by: System Sales PM Version: 1.0 Lean Design with Luxury Performance.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
1U Rack-Mountable 4-Bay NAS Server with iSCSI NAS-7450.
Zeus Server Product Training Son Nguyen Zeus Server Product Training Son Nguyen.
LC Storage Presentation Software Solutions & HW/Systems Architecture Team - Bill Delaney - Mohamad El-Batal 09/17/07.
BHEL – Electronics Division, Bangalore
Improving Networks Worldwide. UNH InterOperability Lab Serial Advanced Technology Attachment (SATA) Use Cases.
Asis AdvancedTCA Class. What is PICMG? PICMG - The PCI Industrial Computers Manufacturer's Group Is a consortium of over 450 industrial computer product.
Windows Azure Conference 2014 Hybrid Cloud Storage: StorSimple and Windows Azure.
Linux Clustering A way to supercomputing. What is Cluster? A group of individual computers bundled together using hardware and software in order to make.
MIS 1.5 Hardware Overview.
Electronics Confidential Information © 3M 2005, All Rights Reserved Enterprise Computing Applications Charlie Staley January 2007.
3/5/2007(c) 2007 UEI Inc.1 Design Review United Electronic Industries DNR-12 -3U 12 DNA Rack With CPU/NIC Enclosure.
Draft Superiority of Fibre Channel Technology Fast & Flexible Tiered Storage October 2005 Revision 2.
Native InfiniBand Storage Deployment & Customer Experiences Dave Ellis Director, HPC Architecture LSI Logic IBTA & OFA DevCon San Francisco September 25,
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Intel  modular server building blocks ( built on Intel  Multi-Flex Technology ) Intel  modular server building blocks ( built on Intel  Multi-Flex.
UNH InterOperability Lab Serial Advanced Technology Attachment (SATA) Use Cases.
OpStor - A multi vendor storage resource management and capacity forecasting software.
Peter Stefan, NIIF 29 June, 2007, Amsterdam, The Netherlands NIIF Storage Services Collaboration on Storage Services.
Draft Superiority of Fibre Channel Technology Fast & Flexible Tiered Storage October 2005 Revision 2.
© 2010 IBM Corporation Storwize V7000 IBM’s Solution vs The Competition.
Module 9 PS-M4110 Overview <Place supporting graphic here>
MaxTronic International Co., Ltd. May 2013 Focused on Data Protection.
Simply the Best! Simply the Best! Corporate Overview Corporate Overview.
ZTF Interconnecting Scheme Stephen Kaye
Mr C Johnston ICT Teacher BTEC IT Unit 02 - Lesson 02 Inside Computers #1 – Motherboards, CPUs, PSUs and Cooling.
GeoVision Solutions Storage Management & Backup. ๏ RAID - Redundant Array of Independent (or Inexpensive) Disks ๏ Combines multiple disk drives into a.
Server Hardware Chapter 22 Release 22/10/2010Jetking Infotrain Ltd.
Cisco Confidential 1 © 2010 Cisco and/or its affiliates. All rights reserved. Data Center Solutions Marketing Data Center Business Advantage Customer Proof.
About Samway Electronic SRL Founded in 2005 in Bucharest, Romania Focused on management and monitoring solutions for telecom/industrial computers Active.
Computer Hardware Mr. Richard Orr Technology Teacher Bednarcik Jr. High School.
BS Test & Measurement Technique for Modern Semi-con devices & PCBAs.
© 2003, Cisco Systems, Inc. All rights reserved _03_2003_c4 © 2003, Cisco Systems, Inc. All rights reserved _03_2003_c4.
Silicon Building Blocks for Blade Server Designs accelerate your Innovation.
Meeting the Data Protection Demands of a 24x7 Economy Steve Morihiro VP, Programs & Technology Quantum Storage Solutions Group
© 2009 EMC Corporation. All rights reserved. Introduction to Information Storage and Management Module 1.1.
Storage Systems Market Analysis Dec 04. Storage Market & Technologies.
InfiniSwitch Company Confidential. 2 InfiniSwitch Agenda InfiniBand Overview Company Overview Product Strategy Q&A.
Enterprise Platforms & Services Division (EPSD) JBOD Update October, 2012 Intel Confidential Copyright © 2012, Intel Corporation. All rights reserved.
March 9, 2015 San Jose Compute Engineering Workshop.
The OIF: A Beacon for Industry Progress and Convergence.
Switched Storage Architecture Benefits Computer Measurements Group November 14 th, 2002 Yves Coderre.
Introducing ULTAMUS TM RAID. The Need for Storage Immediate Accessibility Limited IT Staff Budget Constraints Data Growth Security Levels Retention Characteristics.
Business and Partnering Opportunities: “Windows Server 8” Continuous Availability Designing Systems for Continuous Availability and Scalability Session.
STORAGE ARCHITECTURE/ MASTER): Disk Storage: What Are Your Options? Randy Kerns Senior Partner The Evaluator Group.
Barriers to IB adoption (Storage Perspective) Ashish Batwara Software Solution Architect May 01, 2007.
Surveon Enterprise Solution with Milestone Introduction Sales & Marketing Department.
G043 – Lecture 03 Motherboards and Processors Mr C Johnston ICT Teacher
STORAGE ARCHITECTURE/ MASTER): Where IP and FC Storage Fit in Your Enterprise Randy Kerns Senior Partner The Evaluator Group.
Seagate Confidential Battle Card: Seagate Business Storage 8-bay Rackmount NAS THE BASICS Target Customers & Relevant Value KEEP IN MIND “Need-To-Know”
By Harshal Ghule Guided by Mrs. Anita Mahajan G.H.Raisoni Institute Of Engineering And Technology.
PC COMPONENTS. System Unit Cases This is the cabinet that holds the main components of a computer. It includes a plastic front panel for aesthetic purpose.
WORLD PC-BASED TEST AND MEASUREMENT EQUIPMENT STUDY Study Definition: ‘PC cards that are plugged into slots inside the computer or into PC bus expanders,
Extreme Scale Infrastructure
E2800 Marco Deveronico All Flash or Hybrid system
MILESTONE HUSKY™ M550A 10GbE NVR Hardware Platform with Scalable VMS Software.
MILESTONE HUSKY™ M550A 10GbE NVR Hardware Platform with Scalable VMS Software.
Open-E Data Storage Software (DSS V6)
AIC/XTORE SAS OVERVIEW
Enterprise Computing Applications
Flex System Enterprise Chassis
Demystifying Deduplication
Design Package Contribution for Project Olympus US1-EPYC
Why PC Based Control ?.
What’s in the Box?.
MILESTONE HUSKY™ M550A 10GbE NVR Hardware Platform with Scalable VMS Software.
Presentation transcript:

1 An Introduction to the Storage Bridge Bay Specification

2 Key Points  A new open platform for storage innovations to benefit customers through standardization : Accelerating the availability of new technologies such as: Accelerating the availability of new technologies such as: iSCSIiSCSI SASSAS Storage applications (e.g., VTL, archive)Storage applications (e.g., VTL, archive) Delivering increased quality and affordability Delivering increased quality and affordability

3 Broad Industry Collaboration Membership is growing daily. Expect steady membership growth to continue. Membership is growing daily. Expect steady membership growth to continue.

4 What SBB is  A specification created by a non-profit working group that is defining a mechanical/electrical interface between a passive backplane drive array and the electronics packages that give the array its “personality”

5 VTL Concept: Standardize storage controller slots (SBB) Standardize storage controller slots (SBB) One chassis many controllers One chassis many controllers JBOD RAID FC SAN SAN LAN PCI Express / AS InfiniBand iSCSI SAN Storage Bridge Bay Specification NAS Archive

6 Concept: Standardize storage controller slots (SBB) Standardize storage controller slots (SBB) One controller many chassis One controller many chassis Storage Bridge Bay Specification SBB

7 Storage Bridge Bay Benefits End User Benefit: Increased Quality, Faster Access to New Technologies, Greater Range of Product Offerings, Lower Cost End User Benefit: Increased Quality, Faster Access to New Technologies, Greater Range of Product Offerings, Lower Cost Increased Innovation Platforms built on standard silicon & system building blocks * Actual Investment will vary – conceptual chart based on Intel Marketing Platform Spending Development Time Commercial CPU and Building Blocks and Building Blocks Platform R&D Software & Solution R&D Validation & Test Increased Investment* in solution value Equipment Provider Cost of Goods* Proprietary Hardware and ASICs Platform R&D Software & Solution R&D Validation & Test

8 Key Elements  Targeted at low and mid range storage  Modular backplane connector  Supports Up to 28 drives - SAS, SATA, FC Up to 28 drives - SAS, SATA, FC Redundant bridges/controllers Redundant bridges/controllers Redundant management interface and VPD Redundant management interface and VPD Chassis front view Chassis rear view Note: Actual enclosure designs will not match these drawings

9 Specification Focus SBB Canister VPD EEPROM SBB Backplane Connectors

Specification Status Rev 0.6  Connector/signal definitions  Mechanicals  Basic enclosure management (VPD) 1.0 H1’06 Rev 1.0 – Spec. Completion Pre Release work  Complete SI requirements  Specification ratification 0.6 Draft Q1’062.0 H1‘07 V2.0 Effort Rev 2.0 – Further Standardization  Refined sheet metal requirements  Allowances for more power Prior work SBB Rev 1.0 Release Specification First Products 2007

11 Summary  A standardization effort to benefit end users Increased quality Increased quality Faster access to new technologies Faster access to new technologies Wider range of product offerings Wider range of product offerings Lower cost Lower cost  A new organization with broad industry support  A specification defining the mechanical/electrical interface between disk enclosures and “personality” modules For more information contact or Attend the SBB session at the Intel Developer Forum. Session STGS003 on March 8 th at 2:00 p.m. Moscone Center West, San Francisco For more information contact or Attend the SBB session at the Intel Developer Forum. Session STGS003 on March 8 th at 2:00 p.m. Moscone Center West, San Francisco

12 Backup

13 Specification Covers ComponentDefined Not Defined Bridge  Physical dimensions (L/W/H)  Power budget  Card functionality (e.g., FC-SATA bridge)  Electronic hardware architecture Backplane Connector  Physical dimensions  Number and type of pins  Signaling capability of pins  Signal types (e.g., SAS, SATA, FC, etc.) Backplane  Number of traces for bridge interconnect  Physical dimensions  Signal types (e.g., SAS, FC)  Trace layout Power Supply / Cooling  Power delivered to controller  Cooling required for the controller  Physical dimensions of power supply  Power and cooling requirements for entire enclosure  Power supply connector to the backplane Enclosure Management  Management interfaces signals within the enclosure (e.g., fans, temperature sensors)  Vital Product Data  External management interface (e.g., SMI- S, CIM, SES) Drive Connector / Carrier  Use of Industry std Signal definitions  General purpose Signals available for each carrier  Connectors, Form factor, mounting and keys