Structure Determination: MS, IR, NMR (A review)
17.1 Mass Spectrometry Learning Objectives:
Lecture 6. FT-IR and Raman Spectroscopy. FT-IR Analytical infrared studies are based on the absorption or reflection of the electromagnetic radiation.
Rotational Spectra Simplest Case: Diatomic or Linear Polyatomic molecule Rigid Rotor Model: Two nuclei joined by a weightless rod J = Rotational quantum.
Infrared Radiation 780 nm m Near, Mid and Far
Rotational Spectra Simplest Case: Diatomic or Linear Polyatomic molecule Rigid Rotor Model: Two nuclei joined by a weightless rod J = Rotational quantum.
Lecture 3 INFRARED SPECTROMETRY
Spectral Regions and Transitions
Multipurpose analysis: soil, plant tissue, wood, fruits, oils. Benchtop, portable Validation in-built, ISO compliant Little or no sample preparation. Rapid.
Chapter 19 Nuclear Magnetic Resonance Spectroscopy Nuclear magnetic resonance (NMR) spectroscopy is based on the measurement of absorption of electromagnetic.
Time out—states and transitions Spectroscopy—transitions between energy states of a molecule excited by absorption or emission of a photon h =  E = E.
Common types of spectroscopy
INFRARED SPECTROSCOPY (IR)
WM4 Instrumental analysis. The 3 key instrumental techniques How do we know that salicylic acid contains – OH and –COOH groups? Mass spectroscopy (m.s.).
 PART Requirements for Spectroscopic Techniques for Polymers 1. High resolution 2. High sensitivity (>1%) 3. High selectivity between molecular.
KHS ChemistryUnit 3.4 Structural Analysis1 Structural Analysis 2 Adv Higher Unit 3 Topic 4 Gordon Watson Chemistry Department, Kelso High School.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
NIR Fundamentals and “a little more…”
Pharmacy 325 Infrared (IR) Spectroscopy Dr. David Wishart Rm Ph Hours: anytime after 4 pm.
INFRA RED ABSORPTION SPECTROSCOPY Kateřina Hynštová.
Structure Determination by Spectroscopy Mass spectroscopy Ultraviolet-visible spectroscopy Infrared spectroscopy Nuclear magnetic resonance spectroscopy.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
Infrared Spectroscopy and Mass Spectroscopy
Infrared Spectroscopy
Chem. 31 – 4/1 Lecture.
States and transitions
Chem. 31 – 3/30 Lecture. Announcements I Additional Problem due Wed (along with quiz) No Lab Tomorrow (Campus closed for Cesar Chavez holliday) Exam 2.
Soil Mid Infrared Spectroscopy Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
Chapter 2: IR Spectroscopy Paras Shah
(IR spectroscopy) is the subset of spectroscopy that deals with the infrared region of the electromagnetic spectrum. spectroscopy infraredelectromagnetic.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
Spectrophotometry.
11.3: Analytical techniques can be used to determine the structure of a compound, analyze the composition of a substance, or determine the purity of a.
Spectroscopy Measures light (radiation) absorbed by species in solution. Some radiation is absorbed by ground state electrons in atoms or molecules. Radiation.
INFRARED SPECTROSCOPY
Spectroscopy Chemistry 3.2: Demonstrate understanding of spectroscopic data in chemistry (AS 91388)
Chemistry XXI Unit 2 How do we determine structure? The central goal of this unit is to help you develop ways of thinking that can be used to predict the.
NIR.
12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy Based on McMurry’s Organic Chemistry, 6 th edition.
Why this Chapter? Finding structures of new molecules synthesized is critical To get a good idea of the range of structural techniques available and how.
Infrared Spectroscopy
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
Chemistry 2412 L Dr. Sheppard
California State University, Monterey Bay CHEM312
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
Fourier Transform IR Spectroscopy. Absorption peaks in an infrared absorption spectrum arise from molecular vibrations Absorbed energy causes molecular.
Infrared Spectroscopy
Demonstrate understanding of spectroscopic data in chemistry Chemistry A.S internal credits.
1 Increasing frequency CH 2 =CH-CH=CH 2 Absorption spectrum for 1,3-butadiene.
IB NOTES: Modern Analytical Chemistry. Definitions: Qualitative Analysis: The detection of the __________________ but not the __________ of a substance.
IR, NMR, and MS CHEM 315 Lab 8. Molecular Structure and Spectra The most powerful and efficient methods currently in use to characterize the structure.
Chem. 31 – 6/30 Lecture. Announcements I Lab –Supplement to Co/Cr Lab has been posted online AP2.2 due Quiz 4 today No Class on Monday (July 4 th )
Introduction and Principle of IR Spectrophotometry
SPECTROSCOPY SL Chemistry Topic IHD – Index of hydrogen deficiency (degree of unsaturation) ■Used to determine from a molecular formula the number.
Infrared Spectroscopy: Comparison of Transmission and ATR Techniques Matt Herring Lewis University.
Infrared Spectroscopy
Introduction and Principle of IR Spectrophotometry
Molecular Vibrations and IR Spectroscopy
Lecture 10 IR Theory This Week In Lab: Ch 6 PreLab Due
Analytical methods Prepared By Dr. Biswajit Saha.
INFRARED SPECTROSCOPY Dr. R. P. Chavan Head, Department of Chemistry
WM4 Instrumental analysis
Molecular Vibrations and IR Spectroscopy
化工群英文示例 沙鹿高工 簡佩琳.
Presentation On INFRARED SPECTROSCOPY
Presentation transcript:

10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY UNIVERSITY OF PUERTO RICO AT MAYAGÜEZ Opening your Mind to Vibrational Spectroscopy Rodolfo J. Romañach, Ph.D. UPR-Mayagüez May 14, 2012

2 Infrared (Vibrational) Spectroscopy Regions of Infrared Spectrum: – Far Infrared: 650 – 25 cm -1 – Mid Infrared: 4000 – 650 cm -1 wavelengths from 2.5 m to 25 m). – Near Infrared: – 4000 cm - 1 ( m, or nm). Absorption occurs when the dipole moment of the molecule changes, and the molecule interacts with radiation equal to the frequency of vibration.

H Cl Change in Dipole Moment during Molecular Vibrations Must change for IR absorption to occur. The dipole moment is a measure of the degree of polarity of molecule (magnitude of the separated charges times the distance between them). A measurement of degree of unequal distribution of charges in molecule.

4 Band Intensity in IR Band intensity depends on the rate of change of dipole moment during absorption of IR light. Stronger bands occur when the change in dipole moment is greatest.

5 Infrared Spectroscopy (mid-IR) & Near Infrared Spectroscopy  Infrared Spectroscopy (mid-IR), studied in organic chemistry courses; principal identification method in pharmaceutical industry.  Mid-IR sharp bands that provide structural information on compounds; better than fingerprint.  Near IR weak overlapping bands; difficult to interpret (region of to 4000 cm -1, wavelengths from 0.8 to 2.5 m.)

6 Mid-IR Spectroscopy Widely Used in: Identification of Pharmaceutical Raw Materials and Finished Products. Principal method of material identification in a pharmaceutical manufacturing company. Combination with MS and NMR to determine structure of process impurities and degradation products. Characterization of natural products, use of GC/FT-IR. Forensic Analysis, IR-Microscopy. Environmental Analysis: GC/FT-IR. Surface Analysis, Diffuse Reflectance, Attenuated Total Reflectance, Grazing Angle. Studies of Protein Structure and Dynamics.

7 Group Frequencies  Characteristic of functional groups such as - O-H, -CH 3, -COCH 3, and COOH.  Determined empirically by studying the spectra of many related molecules.  Always found in the spectrum of a molecule containing that group, and always occurs in the same narrow frequency range.  The form of the bands is nearly always the same in every molecule containing that group.

8 Dividing Line  1500 cm -1 dividing line: above 1500 cm -1 if a band has a reasonable intensity, it is a group frequency.  Below 1500 cm -1 the band may be either a group or fingerprint frequency.  Below 1500 cm -1 called the fingerprint region.

9 Typical Identification in Pharmaceutical Industry with Mid-Infrared Spectroscopy

10 Checking Fingerprint Region.

11

12 Mid-IR Spectroscopy + Each compound has a unique mid-IR spectrum. Excellent for identification. Key technique for identifying raw materials in pharmaceutical industry. + Information rich technique, spectra can be interpreted – learning that you have an organic compound, carbonyls, aromatic compounds, etc. - Requires sample preparation, except when attenuated total reflectance is used.

13 Can your HPLC analyze & identify this sample in 1 minute? Sample from Dr. Lysa Chismadia’s collection, RUM Geology Department.

14

15 Advantages of NIRS  Sample preparation is not required leading to significant reductions in analysis time. Waste and reagents are minimized (non- destructive testing).  Excellent analytical method for the study of solids. Capable of ID based on both chemical & physical properties.  Spectra may be obtained in non-invasive manner.  Remote sampling is possible (good for hazardous materials). NIR radiation can be transmitted through silica fiber optics that are relatively inexpensive. non-invasive spectral acquisition & remote sampling Spectroscopy of solids

16 Non-invasive monitoring. Opportunity for following processes. CDI Lab Scale NIRS system,

17 Powder & Solids Probe with liquid attachment Powder and Solids Probe – Courtesy Bruker Optics Extra-long immersion depth: 12” Diffuse Reflection Probe Schematic IR Source IR Energy Sample Delivery Fiber Bundle Collection Fiber Bundle Reflected IR Energy Detector

18 Spectroscopy of the Solid State  Spectroscopy - Interaction between radiation and matter.  Spectra – pattern that indicates absorbance or reflection of radiation as a f(λ) or f(ν).  NIR – offers possibility of study of interaction of solids with radiation since sample preparation is not required. Need to visualize interaction between particle and radiation. May also be used for liquids, but majority of applications for solids avoiding sample preparation.

19 Wide bands - 12,000 – 4,000 cm -1, or 800 – 2500 nm Characterized by Wide Bands Overtones & Combination Bands of O-H, N-H and C-H groups

20 NIR Fundamentals: Electromagnetic Spectrum Nuclear Transitions Spin Orientation in Magnetic Field Molecular Rotations Molecular Vibrations Valance Electron Transitions Inner Shell Electronic Transitions  -Ray Radio, TV WavesMicrowaveInfrared NMR ESRFIRMIR X – Ray visiblevisible NIR Ultraviolet Interaction Region Frequency (cm -1 ) Wavelength (m) 12,500 cm -1 (800 nm)4,000 cm -1 (2500 nm) Courtesy Bruker Optics

21

22 Advantages of NIRS  Possibility of using it in a wide range of applications (physical and chemical), and viewing relationships difficult to observe by other means.  The spectrum may be used to identify the formulation and also to quantify the drug in the formulation. * Cross-sensitivity. *M. Blanco, J. Coello, A. Eustaquio, H Iturriaga, and S. Maspoch, Development and Validation of a Method for the Analysis of a Pharmaceutical Preparation by Near-Infrared Diffuse Reflectance Spectroscopy, Journal of Pharmaceutical Sciences, 1999, 88(5), 551 – 556.

23 Cautions in Working with NIRS  Overlapping bands, not easy to interpret. Differences in spectra are often very subtle.  May confuse chemical & physical effects.  Calibration requires careful experimental design.  Depends on accuracy of reference methods.  Usually not for trace level analysis.  Implementation of NIR requires a significant investment in Human Resources. Not an HPLC !! Over 60% of instruments installed in pharmaceutical companies are never used.

24 NIR Absorption Bands  Absorption bands in the NIR are the result of combination and overtone bands from the fundamental vibrations of C-H, N-H, and O-H bonds seen in the mid-IR.  The overtone and combination bands are 10 – 100 X less intense than the fundamental bands in mid-IR. (Do not confuse energy of vibration with intensity of band).  Differences in spectra are usually very subtle. Instruments have a high signal to noise ratio.

25 MIR vs. NIR: Oleic Acid Absorbance Wavenumber cm -1 Oleic Acid NIR MIR Slide Courtesy Bruker Optics NIR Bands will be 10 – 100 x weaker than mid-infrared bands

26 Fundamentals and Overtones In the case of the anharmonic oscillator, the vibrational transitions no longer only obey the selection rule n = 1. This type of vibrational transition is called fundamental vibration. Vibrational transitions with n = 2, 3,... are also possible, and are termed overtones. Called first, second, and so on, overtones.

27 Subtle Differences in Spectra

28

29

30 Local Mode Effect

31 Subtle Differences,Valuable Info. M. Blanco, D. Valdés, I. Llorente, and M. Bayod, “Application of NIR Spectroscopy in Polymorphic Analysis: Study of Pseudo-Polymorphs Stability”, Journal of Pharmaceutical Sciences, 2005, 94(6), 1336 – 1342.

32 Summary NIR spectra are difficult to interpret and differences in spectra are very subtle, yet it is able to discriminate between spectra of very similar molecules (although the differences are not as easy to discern as in mid-IR). Able to provide both chemical and physical information on a samples in the solid state. Must work cautiously to avoid confusing chemical and physical information.

33 Developing a Calibration Model Most NIR calibration models are multivariate. The absorbance at multiple wavelengths or frequencies are mathematically related to an analyte concentration or physical property. Multivariate regression models like MLR, PLS are used, unlike the univariate linear least squares method used in most analytical chemistry.

34 X. Zhou, P. Hines, and M.W. Borer, “Moisture Determination in a Hygroscopic drug Substance by Near Infrared Spectroscopy”, Journal of Pharmaceutical and Biomedical Analysis, 17(1998), O-H first overtone Absorbance, 1 st - derivative, and 2 nd derivative spectra. 34 Variation Implies Information !! However, variation could come from differences in moisture content (chemical info) or variation in particle size, porosity, density (physical info).

35 X. Zhou, P. Hines, and M.W. Borer, “Moisture Determination in a Hygroscopic drug Substance by Near Infrared Spectroscopy”, Journal of Pharmaceutical and Biomedical Analysis, 17(1998), O-H combination band Absorbance, 1 st -derivative, & 2 nd derivative spectra.

36 Developing a Chemical Quantitative Method Used Partial Least Squares (PLS) regression to relate changes in water content to changes in the NIR spectra. PLS is an example of a multivariate method that uses many responses from the spectrum and relates them to an analytical property. 1 NIR spectra will include variation due to particle size and other physical effects. If you want to measure a chemical property such as concentration then you need to make sure that you are not confusing physical effects with chemical changes. – reason for pretreatment. 1- the methods that we study in analytical chem. class are still univariate)

37 Developing a Chemical Quantitative Method Differences in particle size lead to differences in baseline. Baseline is not related to concentration. May eliminate baseline with 1 st or 2 nd derivative. The changes observed are more related to chemical changes after the spectral pretreatment.

38 Raw spectra ( nm) obtained from ribbons of MCC 200 produced at 15 (straight), 25 (dash), and 45 bars (dot). D, Acevedo, A. Muliadi,A. Giridhar, J.D. Litster, R. J. Romañach, AAPSPharmscitech, 2012, 13(3), 1005 – 1012, DOI: /s Spectra subtracted to zero at one λ (baseline corrected). However, keep effect of pressure on spectrum to develop a NIR model for density.

39 Comparison of Sampling Volume First 2 mm sampled by NIR beam vs. Entire Sampled Analyzed by HPLC or UV method Systematic error in the relationship between the optical (NIR) method and the reference method.

40 Calibration with Error Three types of error:  Random error in the reference laboratory values  Random error in the optical data  Systematic error in the relationship between these two. (e.g. Differences in the sample size of the two methods – sampling error) From: Principles and Practice of Spectroscopic Calibration – H. Mark, John Wiley & Sons, 1991, p. 17

41 The NIR radiation interacts with about 260 mg of sample, the acquisition time is about 0.5 seconds, RMSEP ≈ 0.34 % (w/w). A.U. Vanarase, M. Alcalà, J.I. Jerez Rozo, F.J. Muzzio and R.J. Romañach, “Real-time monitoring of drug concentration in a continuous powder mixing process using NIR spectroscopy, Chemical Engineering Science, 2010, 65(21), 5728 – 5733.