A Novel High Resolution, High Sensitivity SPECT Detector for Molecular Imaging Of Cardiovascular Diseases F. Cusanno (1), R. Accorsi (6), E. Cisbani (1,3),

Slides:



Advertisements
Similar presentations
Instruments for Radiation Detection and Measurement Lab # 4.
Advertisements

MOIRA (MOlecular Imaging with RAdionuclides) F. Garibaldi, gr. Coll. Sanita What: Design (and implement) a SPECT detector with submillimeter spatial resolution.
Imaging Molecolare con radionuclidi: un potente mezzo di indagine di processi biologici in vivo F. Garibaldi - Fisica e tecnologie Nucleari per la Salute.
STEM-AMI OUTCOME TRIAL STem cElls Mobilization in Acute Myocardial Infarction Outcome Trial   A national, multicentre, randomised, open-label, Phase.
Fund BioImag : Emission (Computed) Tomography 1.What is a tracer ? 2.Why is collimation necessary and what are its consequences ? 3.How are the.
Jay H. Traverse, MD Principal Investigator, TIME Study Minneapolis Heart Institute at Abbott Northwestern Hospital University of Minnesota Medical School.
Computers and Computed Tomography

Sezione di Napoli Univ. “Federico II” Experimental study of beam hardening artefacts in photon counting breast computed tomography M.G. Bisogni a, A. Del.
PSD9, Aberystwyth, UK, 15 Sept Politecnico di Milano, Italy Development of a camera for imaging of prompt gamma rays in measurements.
Section 1 fMRI for Newbies
Intracoronary Autologous Bone-Marrow Cell Transfer after Myocardial Infarction: A Double-Blind, Randomized, and Placebo-Controlled Clinical Trial Presented.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Gamma Camera Technology
New Software for PET/MR Image Registration Esmat Elhami, PhD CAP Congress 2014 Sudbury, ON.
1. Review normal electrical flow through the heart. 2. Discuss normal coronary artery anatomy and associated leads reflecting ischemic changes. 3. Identify.
– The clinical utility of ultrafast cardiocentric 3D SPECT novel semi-conductor scanner technology – Berry Allen PhD 31 August 2013.
M. D. A NDERSON Cancer Center Magnetic Resonance Imaging: 4.7 T, 40 cm Bruker Biospec James A Bankson, Ph.D. and John D Hazle, Ph.D. Small Animal Cancer.
Sylwia Heinze-Paluchowska Department of Magnetic Resonance Imaging (NZ56)
An intra-operative beta probe for brain tumor surgery Interfaces Physique Biologie group, University of Paris XI S. Bonzom, L. Ménard, M.A Duval, S. Pitre,
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
John N. Hamaty D.O. Second year student module
F. Garibaldi – INFN Roma and ISS
Prostate probe with SPECT technique
New Perspectives in Molecular Imaging of Cardiovascular Diseases F. Garibaldi - INFN – Roma1 - molecular imaging: the role of radionuclides techniques.
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
High Resolution and High Efficiency Open SPECT Detector for Molecular Imaging Studies of Cardiovascular Diseases on Mice MIOCARDIAL PERFUSION MEASUREMENTS.
November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4.
Characterization of LaBr3:Ce scintillator optimized for spatial resolution in low-energy gamma detection F. Cusanno, E. Cisbani, S. Colilli, R. Fratoni,
Angiographic Estimates of Myocardium at Risk During Acute Myocardial Infarction: a Validation Study Using Cardiac MRI José T. Ortiz, Sheridan N. Meyers,
HEALTH Novel MR-compatible PET detectors for simultaneous PET/MRI imaging FP7-HEALTH-2009-single-stage The focus should be to develop novel.
Recent Advances in Small Animal SPECT instrumentations and techniques F. Cusanno 1, M. Ballerini 1, E. Cisbani 1, S. Colilli 1, R. Fratoni 1, F. Garibaldi.
Automation of Vessel Counting Jessica DeQuachBoris Babenko Christman LabBelongie Lab.
O AK R IDGE N ATIONAL LABORATORY U.S. DEPARTMENT OF ENERGY Image Reconstruction of Restraint-Free Small Animals with Parallel and Multipinhole Collimation:
New techniques for early detection of diseases: imaging of small biological structures with amplifying PET/SPECT probes using SiPm photodetectors An important.
M. D. A NDERSON Cancer Center Nuclear Imaging (M.Cam) Richard E. Wendt III, Ph.D. and William D. Erwin, M.S. Small Animal Cancer Imaging Research Facility.
Filipe Castro Departamento de Física & i3n Universidade de Aveiro C S I(N A ) W AVELENGTH - SHIFTING FIBER GAMMA CAMERA USING S I PM S LIP Lisboa Apr.
A Single Photon Emission Computer Tomograph for breast cancer imaging S. Vecchio a, N. Belcari a, P. Bennati b, M. Camarda a, R. Campanini c, M. N. Cinti.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
A. G. Argentieri 1), E. Cisbani 2), S. Colilli 2), F. Cusanno 2), R. De Leo 1), R. Fratoni 2), F. Garibaldi 2), F. Giuliani 2), M. Gricia 2), M. Lucentini.
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Acquisition time6 min1 min 12 s Collimator height25 mm (Anger)12 mm (HiSens) Detector1 layer, 1 pixel / hole3 layers, 1 pixel / hole3 layers, 4 pixels.
F. Garibaldi 1,, F. Cusanno 1), S. Majewski 3), N. Clinthorne, P. Musico 4),…………………………. TOPEM: a PET TOF probe, compatible with MRI and MRS for diagnosis.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
CEREBRAL BLOOD FLOW QUANTIFICATION FOR ARTERIAL SPIN LABELED PERFUSION MRI AT 3 TESLA 4° Congresso Annuale dell’Italian Chapter dell’ISMRM Perugia,
IN THE NAME OF GOD. What are Stem Cells? Stem cells are a class of undifferentiated cells that are able to differentiate into specialized cell types.
Muhammad Musaddiq.
Molecular Breast Imaging – state of art of design, analysis and optimization processes in industrial context F. Cirillo 1, F. Garibaldi 2,3, S. Gioia 1,
Cardiac Indices in Myocardial Perfusion Scan and Their Impact on the Patient's Prognosis
Journal of Nuclear Cardiology | Official Journal of the American Society of Nuclear Cardiology Rubidium-82 PET imaging is feasible in a rat myocardial.
of Segmental Dysfunction in Myocardial Ischemia
ABSTRACT Background: Although 2D strain imaging has shown promise to define myocardial dysfunction, it provides only subjective assessment about the extent.
Computed Tomography Basics
E. Ponce2-1, G. Garipov2, B. Khrenov2, P. Klimov2, H. Salazar1
Imaging molecolare ad alta risoluzione spaziale ed alta efficienza
Advances in Imaging Instrumentation for Nuclear Cardiology
Journal of Nuclear Cardiology | Official Journal of the American Society of Nuclear Cardiology Detection and quantitation of Right Ventricular Ischemia.
by: Prof.Dr. Hosna Moustafa Cairo University, Egypt
Validation Against Sonomicrometry
HIGH RESOLUTION, HIGH MOLECULAR IMAGING CODED APERTURE THE DETECTOR
Meihua Zhu, MD, PhD; Muhammad Ashraf, MD
Application of Nuclear Physics
The Role of Stress Cardiac Magnetic Resonance in Women
Cardiac Cell Repair Therapy: A Clinical Perspective
A multichannel compact readout system for
Eduardo Marbán, MD, PhD  Mayo Clinic Proceedings 
Volume 24, Issue 2, Pages (February 2016)
Pál Maurovich-Horvat et al. JIMG 2010;3:
Presentation transcript:

A Novel High Resolution, High Sensitivity SPECT Detector for Molecular Imaging Of Cardiovascular Diseases F. Cusanno (1), R. Accorsi (6), E. Cisbani (1,3), S. Colilli (1,3), G De Vincentis (2), R. Fratoni (1,3), F. Garibaldi (1,3), F. Giuliani (1,3), M. Gricia (1,3), M. Lucentini (1,3), M. L. Magliozzi (3), G. Marano (3), S. Majewski (4), S.P.G. Mok (5), M Musumeci (3), F. Santavenere (1,3), S. Torrioli (3), B. M. W. Tsui (4), Y. Wang (5) (1) Istituto Nazionale di Fisica Nucleare, Sezione Sanità, Rome, Italy, (2) Università La Sapienza, Rome, Italy, (3) Istituto Superiore di Sanità, Rome, Italy, (4) Jefferson Lab, Newport News, USA, (5) Johns Hopkins University, Baltimore MD, USA, (6) The Children's Hospital, Philadelphia, USA 10 cm 2.5 cm MIOCARDIAL PERFUSION High Resolution Upper Head: Pin Hole: 0.5 mm Scintillator: NaI(Tl), 1.5 pitch 6 mm thick Photodetector: H8500 (2×2) R t ~ 0.8 mm, Eff ~ 0.5 cps/μCi M ~ 3, FoV ~ 33 mm High Sensitivity Lower Head: Pin Hole: 1.0 mm Scintillator: NaI(Tl), 1.2 pitch 6 mm thick Photodetector: H8500 (4+4) R t ~ 1.4 mm, Eff ~ 1.7 cps/μCi M ~ 2.7, FoV ~ 37 mm DETECTOR CHARACTERIZATION PHANTOM MEASUREMENTS Phantom Overall Diameter: ~ 25 mm Holes Diameter: ~ from 0.8 to 1.3 mm Filling Radioactive : ~ 4.5 mCi Tc 99m -perctenate Acquisition Parameters: Number of Views: 60, 6° (360°) Time per View: ~ 2 minutes Miniature acrylic resolution phantom (left), and reconstructed image (right), sum of 21 trans- axial slices. 0.8 mm capillaries are clearly separated on image. Mutual perpendicular cross section through sub- millimetre-resolution 3-dimensional myocardial perfusion image volume of living mouse. Data were acquired during 60 minutes, starting 1 hour after administration of 6.7 mCi of 99mTc-MIBI. Short-axis slice (left) showing myocardial perfusion in right ventricular (RV) and left ventricular (LV) wall. Horizontal long-axis slice (right). 1.3 mm 1.2 mm 1.1 mm 1.0 mm 0.9 mm 0.8 mm CONCLUSION The characterization of the upper head of the above described SPECT system has demonstrated spatial resolution capability better than 0.8 mm. Analysis of lower head data as well as the combined reconstruction from the two sets of projections are in progress. Activity is also ongoing to probe the reproducibility of pinhole SPECT measurements of global and regional ventricular function in infarcted as well as in wild type mice. Male VFB/N Mouse Age: ~ 12 settimane Weight: ~ 30 g Injected Radiotracer: ~ 6.7 mCi Tc99m-MIBI in ~ 0.02 ml Acquisition Parameters: Number of Views: 60, 6° (360°) Time per View: ~ 60 seconds Acquisition Delay After Injection: ~ 1 hour Spine Liver BONE SCAN Male VFB/N Mouse Age: ~ 12 settimane Weight: ~ 30 g Injected Radiotracer: ~ 2 mCi Tc 99m -MDP in ~ 0.05 ml Acquisition Parameters: Number of Views: 60, 6° (360°) Time per View: ~ 2 minutes Acquisition Delay After Injection: ~ 2 hours Front (left) and lateral view (right) of reconstructed image volume of thoracic bone scan. Data were acquired in 120 minutes, 2 hours after injection of 2 mCi of 99mTc-MDP. Tracer uptake in spine, shoulder-blade and ribs are visible. DUAL HEAD DETECTOR 5 mm LV RV 5 mm LV RV Shoulder-blade Ribs 8 cm 2.5 cm Sistem Requirement: Overall Resolution ~ 0.8 mm Sensitivity ~ 10 cps/μCi (allowing dynamic studies and Thomographic acquisition 1 hour) Field of View ~ 25 × 25 mm 2 (mouse thoracic area dimension) Miocardium thicness ~ 0.8 mm !!!! Mice Heart ~ 8 mm! Acute myocardial infarction (AMI or MI), more commonly known as a heart attack, occurs when the blood supply to a part of the heart is interrupted. The resulting ischemia or oxygen shortage causes damage and potential death of heart tissue. Diagram of a myocardial infarction (2) of the tip of the anterior wall of the heart (an apical infarct) after occlusion (1) of a branch of the left coronary artery (LCA, right coronary artery = RCA). Small Animal SPECT Imaging (mice) allows: Direct monitoring of the dynamics of the infused cells; In vivo monitoring of disease/teraphy efficacy; Translational studies SPECT SYSTEM SETUP, CHARACTERIZATION AND PRELIMINARY MEASUREMENTS ABSTRACT Cardiovascular disease is the leading cause of disability and mortality for both men and woman in the western countries. Various stem cells hold promise for the treatment of human cardiovascular disease; results of clinical trials are somewhat disappointing emphasizing the needed of preclinical investigation as a means of better understanding basic mechanism. Regardless of stem cell origin, future clinical trials will require that the location and number of such cells be tracked in vivo, over long periods of time. Small animals are used widely in biomedical research. Mice in particular are favorite animal subjects. We have developed a compact, open, Dual Head pinhole SPECT system for high resolution molecular imaging with radionuclides of mice, for the study of stem cells capability to recover myocardial infarction. The gamma detector is largely made of standard, on the shelf, components (pinhole tungsten collimators, pixellated scintillators, matrix of multi-anode PMTs and individual channel readout). Measurements have been performed on phantoms and live mice devoted initially to test and calibrate the system and to optimize protocols. The implemented system and the first results will be presented, demonstrating the effectiveness of our dedicated SPECT detector for small animal imaging. SMALL ANIMAL IMAGING IN MIOCARDIAL INFARCTION THERAPHY OUTLOOK IMPROVE RESOLUTION: Gated Image Heart Rate and Volume Change affect Image Quality; Intrinsic Resolution Sub-millimetre Intrinsic resolution could be achieved with: Rugged Scintillator Material CsI(Na), CsI(Tl), pixel of mm are available; LaBr 3 (Ce) Continuous, resolution of mm are obtainable depending on design IMPROVE EFFICIENCY: Multi Pinhole Collimation A factor 2 4 (depends on design) Increase Number of Detector Heads A factor 4 8 (depends on mechanical constraint) Combine Reconstruction from Different Sets of Projections A factor 4 8 (depends on Number of Detector Heads) MOVE TO MULTIMODAL APPROACH: Open System Could Be Used in Conjunction with: Optical Detector (high sensitivity) MRI (anatomical high resolution Information) to get morphological as well functional features. Magnetic field requires new photodetector technology (SiPM). Post-infarction survival has improved in recent years but NONE of the therapies is able to reverse the destructive cascade that occurs after acute myocardial infarction and lead to heart failure. Right now the results of clinical trials are somewhat disappointing: PRECLINICAL INVESTIGATION NEEDED to better understand basic mechanisms: Best cell to deliver Route of delivery Fate of stem cells Action mechanism Have a look at P. Musicos poster: A multichannel compact readout system for single photon detection: design and performances Have a look at P. Musicos poster: A multichannel compact readout system for single photon detection: design and performances