Field Analysis Quality Control

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Analyze-Immediately Parameters pH Analyze Immediately Within 15 minutes of collection: pH Residual Chlorine Temperature Chlorine Dioxide Dissolved Oxygen.
Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Quality is a Lousy Idea-
LABORATORY CERTIFICATION & DATA QUALITY MICHAEL W. MILLER, Ph.D. NJ-DEP Office of Quality Assurance
Contracting for Laboratory Services Ann Mullin Cleveland US Geological Survey Presented to the Environmental Protection Agency Science Advisory Board April.
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
Module 6 Effluent Monitoring and Receiving Water Monitoring.
Chain of Custody Records Proper Documentation Techniques Dr. Richard Medina Environmental Testing and Consulting, Inc.
Mentoring Session Technical Assistance Committee Method Modifications.
Wastewater Laboratory Certification Overview 1. What is laboratory certification? “Laboratory certification is a process that provides formal recognition.
Legal Defensibility in the Laboratory To Protect and Enhance Kentucky’s Environment KWWOA April 17, 2013.
Module 6A QAPP for In House and Offsite Testing. Chris Foley Compliance Program Manager Module 6A – QAPP for In House and Offsite Testing 2.
Good Manufacturing Practices Guilin, PRC Dr AJ van Zyl for Quality Assurance and Safety: Medicines Medicines Policy and Standards Health Technology and.
Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Wolfgang Garche Saxony-Anhalt.
World Health Organization
Interpreting Your Lab Report & Quality Control Results
Preparing for Accreditation Jerry L. Parr Catalyst Information Resources, L.L.C. TNRCC Trade Fair May 7, 2002.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Importance of Quality Assurance Documentation and Coordination with Your Certified Laboratory Amy Yersavich and Susan Netzly-Watkins.
DOW Laboratory Certification Program Update – 2015 Presentation to: KWWOA April 15, 2015 Department for Environmental Protection Energy & Environment Cabinet.
OPTIMISING CHEMICAL ANALYSIS FOR THE WFD BY QUALITY ASSURANCE PROCEDURES & ACCREDITATION An Overview OPTIMISING CHEMICAL ANALYSIS FOR THE WFD BY QUALITY.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Quality Assurance/Quality Control Policy
Standard Operating Procedures l At l Call for help at Orlando Office Tallahassee.
1 Module 6 Effluent Monitoring and Receiving Water Monitoring Seattle, Washington April 24-25, 2012.
QA/QC FOR ENVIRONMENTAL MEASUREMENT Unit 4: Module 13, Lecture 2.
Quality Assurance Plans (QAP)
Chapter 10 Verification Procedures. Objective In this module, you will learn: u How to define verification u What functions are part of HACCP plan verification.
QA/QC FOR ENVIRONMENTAL MEASUREMENT
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Understanding and Implementing SWAMP Comparability: Quality Assurance SWAMP Quality Assurance Help Desk Quality Assurance Research.
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
DOW Laboratory Certification Program Update – 2013 Presentation to: KWWOA April 17, 2013 Department for Environmental Protection Energy & Environment Cabinet.
VALIDATION METHODOLOGY
Inspection Issues in the Analytical Laboratory: An FDA Perspective Yvonne McKnight Chemist US Food and Drug AdministrationPhone: x
Laboratory Technical Issues Presentation to: KWWOA April 9, 2014 Department for Environmental Protection Environmental & Public Protection Cabinet To Protect.
Fundamentals of Writing an Effective QAP Presentation to: KWWOA April 15, 2013 Department for Environmental Protection Energy & Environment Cabinet To.
Quality WHAT IS QUALITY
DOW Laboratory Certification Program Update – 2014 Presentation to: KWWOA April 9, 2014 Department for Environmental Protection Energy & Environment Cabinet.
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Microbiology Overview KWWOA April 09, 2014 Department for Environmental Protection Energy & Environment Cabinet.
Quality Assurance Plan (QAP) Department for Environmental Protection Environmental & Public Protection Cabinet To Protect and Enhance Kentucky’s Environment.
Introduction The past, the present and the future.
Quality Control/ Quality Assurance Annabelle Allison ITEP/TAMS Center.
Important informations
Understanding Your QC Presentation to: KWWOA April 15, 2015 Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance.
Laboratory QA/QC An Overview.
Leukocyte-Reduced Blood Components Lore Fields MT(ASCP)SBB Consumer Safety Officer, DBA, OBRR, CBER September 16, 2009.
USEPA REGION 4 Quality Management Plan ( For training purposes only)
Wastewater Laboratory Certification Presented at: KWWOA April17,
Quality Assurance How do you know your results are correct? How confident are you?
Laboratory Certification Update Part 2 Common Findings KWWOA Louisville April 15, 2015 Presented by Frank Hall, Laboratory Certification Coordinator.
ECOS Information Session Draft EPA Quality Documents February 13, 2013 Presented by EPA Quality Staff, Office of Environmental Information For meeting.
Forum FM308: Policy Changes Tuesday June 5 10:00 a.m. AIHA Laboratory Accreditation Policy Changes—ISO “How Do Changes Affect My Laboratory?” “What.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Field-Only Certification Presented by Frank Hall, Laboratory Certification Coordinator.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Why do I need a Chain of Custody (COC)? Presentation to: KWWOA Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance.
Chapter 10 Verification Procedures.
Quality is a Lousy Idea-
Overview of Quality Assurance
EPA Method Equivalency
Chapter 10 Verification Procedures.
Quality is a Lousy Idea-
Observations from California’s On-Site Assessment Unit
Collaborative Efforts to Implement On-Line Analyzer Technology for Regulatory Total Residual Chlorine Monitoring Stacie Crandall Chief, Laboratory Division.
EPA Method Equivalency
Topics in Microbiology Quality Assurance Project Plan Essentials
Why Use Them? By: Marcy Bolek – Alloway
Presentation transcript:

Field Analysis Quality Control Presentation to: KWWOA April 16, 2013 Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance Kentucky’s Environment

Scope of Field Methods pH Conductivity Dissolved Oxygen (DO) Turbidity Total Residual Chlorine (TRC) Temperature Flow

Legal Defensibility Legal Defensibility:  Compliance monitoring data shall be made legally defensible by keeping thorough and accurate records.  The Laboratory Quality Assurance Plan and/or SOPs shall describe the policies and procedures used by the facility for record integrity, retention, and storage. Chain of custody procedures shall be utilized.

Reference Methods 40 CFR 136.3 – list of EPA approved methods 40 CFR 136.4 & 136.5 – ATP Procedures 40 CFR 136.6 – Method Modification EPA Method Modification Rule (5/18/2012) SM Reference Nomenclature 4500-H+ B-2000 Use QC from SM 20th, 21st or 22nd Ed. only SM 22nd Ed. has useful QC (e.g. 2020B)

Field QA/QC Objectives QA/QC systems and procedures are employed to ensure that environmental results are of a known quality and meet their intended use (compared to data quality objectives; DQOs).

40 CFR 136.7 Demonstration of Capability (DOC). Method Detection Limit (MDL). Laboratory Reagent (method) Blank (LRB). Laboratory Fortified Blank (LFB), also referred to as a spiked blank or laboratory control sample (LCS). Matrix spike (MS), matrix spike duplicate (MSD) or laboratory fortified blank duplicate (LFBD) for suspected difficult matrices.

40 CFR 136.7 (cont) Internal standards, surrogate standards (for organic analysis) or tracers (for RADS). Calibration (initial and continuing), initial and continuing performance (ICP) solutions also referred to as initial calibration verification (ICV) and continuing calibration verification (CCV). Control Charts (or other trend analyses of quality control results).

All QC elements must be addressed 40 CFR 136.7 (cont) Corrective Actions (root cause analyses). QC acceptance criteria. Definitions of a batch (preparation and analytical. Specify a minimum frequency for conducting the QC checks. All QC elements must be addressed in the QAP/SOP

Quality Assurance An integrated system of management activities involving planning, implementation, documentation, assessment, reporting, and quality improvement to ensure that a process, item, or service is of the type and quality needed and expected by the client (intended use).

Quality Assurance Criteria QAP/SOP Calibration procedures Calibration verification – 2nd source standard Quality control samples (QCS) Equipment Logs / Field Notebooks Field personnel training Annual Performance Test Study Demonstration of Capability (DOC) Chain-of-Custody (C-O-C)

EPA Quality Standard EPA Quality Standard for Environmental Data Collection, Production, and Use by non-EPA (External) Organizations (CIO Standard 2106-S-02) – DRAFT Replaces QA/R-2 – QMPs Replaces QA/R-5 – QAPPs CIO Guidance 2106-G-05 QMP (Draft) Handbook for Developing QAPPs (Draft)

Equipment Log / Field Notebook Manufacturer, model and serial number Significant modifications Repair and maintenance history Calibration history (where relevant) Performance history Calibration Daily calibration / verification information Field activities

Performance Test Study Perform an annual PT Study for: pH Conductivity Turbidity Total Residual Chlorine DOW must receive a copy of the PT Study sent directly from the provider Two consecutive failures – submit a corrective action plan to DOW

Demonstration of Capability Perform DOC annually using the field method as written in the QAP/SOP Document DOC results DOC template for DOC results are provided on the DOW wastewater website Four (4) replicates (+20% of their mean) Percent relative standard deviation <15%

Chain of Custody Type of sample (e.g. grab, composite, split sample, etc) Sample matrix Type of container (e.g. glass, plastic) Required sample volume Sample holding times Preservative required Field quality control

Quality Control The overall system of technical activities that measure the attributes and performance of a process, item, or service against defined standards to verify that they meet the stated requirements established by the customer; operational techniques and activities that are used to fulfill requirements for quality.

Quality Control Criteria Blanks (reagent, field, equipment, etc) Accuracy (Bias) Precision Establish frequency of QC sample analysis Utilize acceptance criteria Document corrective action

Calibrate the instrument with 4.0, 7.0, and 10.0 S.U. buffer pH Measurements Calibrate the instrument with 4.0, 7.0, and 10.0 S.U. buffer Record slope (0.95-1.05) Verify calibration with a 7.0 S.U. (mid-level) 2nd source buffer (+0.1 S.U.) RECORD CALIBRATION INFORMATION Sample duplicate (one/twenty samples) %Difference ~ +20%

Conductivity Measurements Calibrate instrument using known conductivity standards as per manufacturer Verify calibration using a 2nd source standard RECORD CALIBRATION INFORMATION Reagent blank (one/batch) Result > detection limit = corrective action Sample duplicate (one/twenty samples) %Difference ~ +20%

Dissolved Oxygen Measurements Calibrate instrument as per manufacturer RECORD CALIBRATION INFORMATION Measure environmental samples Sample duplicate (one/twenty samples) %Difference ~ +20% At new location where altitude may have changed the DO meter must be re-calibrated

Turbidity Measurements Calibrate instrument as per manufacturer 3 points minimum Verify calibration using a 2nd source standard RECORD CALIBRATION INFORMATION Reagent blank (one/batch) Result > detection limit = corrective action Sample duplicate (one/twenty samples) %Difference ~ +20%

Total Residual Chlorine (TRC) Calibrate/verify instrument as per manufacturer Verify calibration using a 2nd source standard RECORD CALIBRATION INFORMATION Reagent blank (one/batch) Result > detection limit = corrective action Sample duplicate (one/twenty samples) %Difference ~ +20%

Temperature Measurements Calibrate instrument as per manufacturer Apply NIST Correction Factor RECORD CALIBRATION INFORMATION Measure environmental samples Sample duplicate (one/twenty samples) %Difference ~ +20%

Flow Measurements Document device used to make flow measurements Record all information used to calculate flow, including units Show calculation used to determine flow

Questions ?

Contact Information Patrick Garrity Franklin C. Hall, Jr. Kentucky Department for Environmental Protection Division of Water 200 Fair Oaks Lane; 4th Floor Frankfort, KY 40601 Phone: (502) 564-3410 Email: patrick.garrity@ky.gov frank.hall@ky.gov