Figures for Chapter 4 Electroacoustic Performance

Slides:



Advertisements
Similar presentations
Figures for Chapter 9 Prescription
Advertisements

Figures for Chapter 7 Advanced signal processing Dillon (2001) Hearing Aids.
Real-ear Measurements with the A-35
6500-CX Calibration. Warning Signs a.k.a. Your 6500-CX might be out of calibration if... n The analyzer doesn’t level. n Distortion measurements seem.
Alternative Assessments for Musicians Marshall Chasin, AuD., M.Sc., Reg. CASLPO, Aud(C) Musicians’ Clinics of Canada.
Figures for Chapter 16 CROS, bone conduction and implanted aids Dillon (2001) Hearing Aids.
Viewer’s notes... to help you …  At the bottom left of each page there is a page number, when the slide has finished an automated sequence a small star.
Figures for Chapter 5 Earmolds and earshells Dillon (2001) Hearing Aids.
An Update on Hearing Aid Testing
Probe Tube Microphone Measurements (Basics and Definitions) Greg Nassar MCHAS Team University of Manchester.
Verifying Open-Ear Fittings With Speech-Mapping
The sources of wind noise in hearing aids By Harvey Dillon, Inge Roe, and Richard Katsch, National Acoustic Laboratories This project was kindly sponsored.
MCHAS Modernising Children’s Hearing Aid Services Acoustic Feedback Reduction.
FP35 Hearing Aid Analyzer
Chapter 6 (Sections ) Sound. The speed of sound in a substance depends on: the mass of its constituent atoms, and the strength of the forces between.
Chapter 17 Sound Waves. Introduction to Sound Waves Waves can move through three-dimensional bulk media. Sound waves are longitudinal waves. They travel.
Electroacoustic Testing of DSP Hearing Aids Christine Cameron & Mary Hostler MCHAS Team University of Manchester.
Figures for Chapter 3 Hearing aid systems Dillon (2001) Hearing Aids.
Ultrasound Medical Imaging Imaging Science Fundamentals.
TOPIC 5 NONBEHAVIORAL ASSESSMENT MEASURES IMMITANCE AUDIOMETRY.
Real Ear Testing Measures how a hearing aid performs in the ear Real Ear Unaided Response (REUR) Real Ear Aided Response (REAR) Real Ear Insertion Response.
1 Sinusoidal Waves The waves produced in SHM are sinusoidal, i.e., they can be described by a sine or cosine function with appropriate amplitude, frequency,
ANSI Overview Hearing Aid Testing and Verification What is ANSI?
RECD Refresher Course 17th November 2004 Setting prescriptive targets Greg Nassar Clinical Scientist MCHAS.
Modernising Children’s Hearing Aid Services RECD Measurements Wave 4 EJB 17/05/04.
Wind noise in hearing aids
Introduction to the FONIX 7000 Hearing Aid Test System Software version 1.60.
R3.6.4 Improved Hearing Assessment in Noisy Environments – Parts 1 & 2 Project Leader: Michael Fisher Principal Researcher (Part 1): the late Ben Rudzyn.
Summer 2007 SPA 4302 Pure Tone Audiometry.
Modernising Children’s Hearing Aid Services Sound Field Testing MCHAS TEAM Wave 4 SFR 17/05/04.
Vibrations Sound waves are compression waves. They are made of atoms being pushed, or compressed, by other atoms. Why wouldn’t sound waves carry in.
Amplification/Sensory Systems SPA 4302 Summer 2007.
Amplification systems: Hearing aids May be analog or digital May be analog or digital Consists of a microphone, amplifier, and loudspeaker. Consists of.
Hearing aids in noisy environments: Do hearing aids affect risk for NIHL? Fligor and Chasin.
Figures for Chapter 6 Compression
Figures for Chapter 15 Special issues for children Dillon (2001) Hearing Aids.
Train-the-trainer. Hide it A new product model is born – the MIC  MIC – the Microphone-In-Concha model  The microphone tube placement in the Concha.
Robert E. Novak Ph.D., CCC-A Clinical Professor- Department of Speech, Language and Hearing Sciences Director of Clinical Education in Audiology and Interim.
Hearing Aids (HA) Or technology to the rescue Upcoming Talk: Isabelle Peretz Musical & Non-musical Brains Nov. 12 noon + Lunch Rm 2068B South Building.
INIZIA 3 | 1 Product Introduction. Better hearing now starts with Inizia.
Figures for Chapter 1 Introductory concepts
Figures for Chapter 10 Hearing Aid Selection Dillon (2001) Hearing Aids.
Figures for Chapter 14 Binaural and bilateral issues Dillon (2001) Hearing Aids.
New Features on the FONIX FP35 Hearing Aid Analyzer
Fitting and Evaluation of FM Systems for HA Users.
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Slide 17-1 Lecture Outline Chapter 17 Waves in Two and Three Dimensions © 2015 Pearson Education, Inc.
FP35 Hearing Aid Analyzer
Hearing Detection Loudness Localization Scene Analysis Music Speech.
CSD 3103 anatomy of speech and hearing mechanisms Hearing mechanisms Fall 2008 The Outer Ear.
Figures for Chapter 8 Candidacy Dillon (2001) Hearing Aids.
Learning about your choices. What options do you have? Do nothing Get a hearing aid Get a cochlear implant Learn Sign Language.
Chapter 17 Sound Waves 17.1 Pressure variation in Sound Waves 17.2 speed of Sound Waves 17.3 Intensity of Periodic Sound Waves 17.4 The Doppler Effect.
Acoustic Immitance (Impedance and Admittance)
P.1 Book 3B Section 8.2 Wave nature of sound Anti-noise headphones Sound is produced by vibrations Wave properties of sound Sound as a longitudinal wave.
Behind-the-ear hearing aids Common problems. City Lit Objectives Understand the importance of earmoulds and tubing Be aware of common hearing aid faults.
Hz A A A A A A LDL for speech Aided Speech output Functional Gain: The way.
A COMPARISON OF wRECD AND RECD VALUES AND TEST-RETEST RELIABILITY
Equipment for Measuring Hearing and Calibration
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Copyright © American Speech-Language-Hearing Association
REM AND SREM FITTING COMPARISONS OF VENTED AND UNVENTED HEARING AIDS USING THE AUDIOSCAN VERIFIT AND VERIFIT2 Paula Folkeard, AuD1, John Pumford, AuD2,
Introduction to the 7000 Hearing Aid Test System
Copyright © American Speech-Language-Hearing Association
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Figures for Chapter 11 Trouble-shooting and fine-tuning
Copyright © American Speech-Language-Hearing Association
A near–quantum-limited Josephson traveling-wave parametric amplifier
Ben Scholl, Xiang Gao, Michael Wehr  Neuron 
Therapeutic equipment I
Presentation transcript:

Figures for Chapter 4 Electroacoustic Performance Dillon (2001) Hearing Aids

Ear simulator V1 V2 V4 V3 Dampers Microphone Figure 4.1 Simplified internal structure of a four-branch ear simulator. Source: Dillon (2001): Hearing Aids

Couplers and ear simulators Photo removed to minimize file space Figure 4.2 Several couplers and their adapters, and an ear simulators. Source: Dillon (2001): Hearing Aids

2-cc couplers ITE / ITC / CIC Figure 4.3 The internal dimensions and coupling methods for several 2-cc couplers. Putty HA1 Microphone 2 mm dia Insert earphone 25 Earmold simulator 18 mm 18 3 mm dia HA2 HA2 2 cc cavity Microphone Source: Dillon (2001): Hearing Aids

Real-ear to coupler difference Figure 4.4 RECD: SPL generated in the average adult real ear canal minus SPL generated in an HA1 2-cc coupler. Source: Dillon (2001): Hearing Aids

Photo removed to minimize file space 2-cc coupler and control microphone Photo removed to minimize file space Figure 4.5 A hearing aid connected to a coupler, with a control microphone positioned next to the hearing aid microphone. Source: Dillon (2001): Hearing Aids

Gain-frequency response Figure 4.6 Gain-frequency response (measured with a 60 dB SPL input level) and OSPL90-frequency response of a BTE measured in a 2-cc coupler with a swept pure tone. The 60 dB curve can be read against either axis; the OSPL90 curve must be read against the left hand axis. Source: Dillon (2001): Hearing Aids

Input-output diagram Figure 4.7 Input-output diagram of a compression hearing aid at 2 kHz (bold line) and lines of constant gain (dotted lines). Source: Dillon (2001): Hearing Aids

Equivalent input noise Figure 4.8 Equivalent 1/3-octave input noise of a typical hearing aid as a function of frequency, and maximum acceptable 1/3-octave noise. Source: Dillon (2001): Hearing Aids

REAG = A - C M A F C Figure 4.9 Location of SPLs involved in the measurement of real-ear aided gain. F is located in the undisturbed sound field (e.g. with the head absent), C is at the control microphone location on the surface of the head, M is at the hearing aid microphone port, and A is within the residual ear canal close to the eardrum. Source: Dillon (2001): Hearing Aids

SPL in ear canal Figure 4.10 Calculated pattern of SPL in the ear canal versus distance from the eardrum at a frequency of 6 kHz. The solid curve is for total reflection from the eardrum with no phase shift at the drum, the dashed line is for 50% power reflected from the drum with no phase shift, and the speckled line is for 50% reflected with a 45 degree phases shift at the drum. Source: Dillon (2001): Hearing Aids

Standing-wave minimum Figure 4.11 Distance from the eardrum at which SPL in the ear canal will be a minimum. Source: Dillon (2001): Hearing Aids

Real-ear aided gain Figure 4.12 Typical REAG display for a vented, low to medium gain hearing aid, displaying the expected low frequency plateau. Source: Dillon (2001): Hearing Aids

Insertion gain = A - U U M A F F Aided Unaided C C Figure 4.13 Location of SPLs involved in the measurement of insertion gain. F is located in the undisturbed sound field (with the head absent), C is at the control microphone location on the surface of the head, M is at the hearing aid microphone port, A is at the eardrum when aided, and U is at the eardrum when unaided. Source: Dillon (2001): Hearing Aids

Source: Dillon (2001): Hearing Aids REIG = REAG - REUG Figure 4.14 Real ear unaided and aided gains (top half). The difference between these curves is the insertion gain, shown as the shaded region in the top half and as the curve in the lower half. Source: Dillon (2001): Hearing Aids

Probe position for insertion gain (c) (d) Figure 4.15 Probe positioning for measuring insertion gain: (a) noting a landmark on the ear; (b) marking the probe; (c) measuring the unaided response; (d) measuring the aided response. Source: Dillon (2001): Hearing Aids

Photo removed to minimize file space Calibrating the probe Photo removed to minimize file space Figure 4.16 Positioning of the probe microphone against the control microphone during calibration. Source: Dillon (2001): Hearing Aids

Feedback Forward path (gain) Feedback path (attenuation) Figure 4.17 The feedback mechanism in hearing aids. Source: Dillon (2001): Hearing Aids

Feedback Figure 4.18 Coupler gain of a hearing aid with the volume control adjusted in 2 dB steps. One further increase resulted in oscillation. Source: Dillon (2001): Hearing Aids

Probe-induced feedback path Cross section of earmold Skin around canal Gap created by probe tube Probe tube Figure 4.19 Leakage paths created by the insertion of a probe tube between an earmold or shell and the ear canal. Source: Dillon (2001): Hearing Aids

Photo removed to minimize file space Stethoclip Figure 4.20 A stethoclip attached to a CIC hearing aid. Source: Dillon (2001): Hearing Aids

Feedback - ITE Wax pushes hearing aid away from the canal wall Microphone tube detached at either end Wax directs sound into vent or slit leak Loose fit of shell Receiver tube detached at either end Microphone or receiver touching each other or touching case Vent too large, or vent insert fallen out, or vent too close to microphone port, or vent overhung by pinnae Figure 4.21 Common leakage points, leading to feedback oscillation, in ITE, ITC, and CIC hearing aids. Source: Dillon (2001): Hearing Aids

Feedback - BTE Split in earhook Wax pushes earmold away from the canal wall Tubing too loose a fit on earhook Microphone or receiver touching case Earhook too loose a fit on aid Wax directs sound into vent or slit leak Tubing split Vent too large, or vent insert fallen out Earmold too loose Figure 4.22 Common leakage points, leading to feedback oscillation, in BTE hearing aids. Source: Dillon (2001): Hearing Aids