ARRT & Other DIGITAL Terms Defined Supplement to HW assignment

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

Image Reconstruction.
MONITORS Known as a display screens. Monitors present visual images of text and graphics. Monitors vary in size, shape, and cost.
The Field of Digital Radiography
Copyright © 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins CHAPTER 15 Creating the Digital Image.
Primary Exposure Factors IV
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Quality Assurance and Digital Radiography
Digital Radiography.
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
RAD 350 Chapter 17Digital Rad Tech. Spatial Resolution – ability to distinguish small items in close proximity with near the same atomic mass density Spatial.
Motivation Application driven -- VoD, Information on Demand (WWW), education, telemedicine, videoconference, videophone Storage capacity Large capacity.
1 DIGITAL RADIOGRAPHY. 2 Digital Radiography A “filmless” imaging system introduced in 1987 Digital radiography uses an electronic sensor, instead of.
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Optical Density and Brightness
Unsharpness Calculations and Resolution By Professor Stelmark.
Chapter 6 Cassetteless Equipment and Image Acquisition
Viewing the Digital Image
Digital Technology 14.2 Data capture; Digital imaging using charge-coupled devices (CCDs)
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
 A monitor or display is an electronic visual display for computers.  The monitor consists of : o the display device o circuitry o enclosure The display.
Monitor. The Basics Often referred to as a monitor when packaged in a separate case, the display is the most-used output device on a computer. The display.
Digital Image Characteristic
Image Characteristics. What is an image? Dictionary meaning An optical appearance An optical appearance A form of semblance A form of semblance A mental.
Unit III Creating the Image. Unit III Creating the Image.
Chapter 6: Digital Radiographic Imaging
Computers in Imaging Q & A Robert Metzger, Ph.D..
Quality Control.
Elsevier items and derived items © 2008 by Mosby, Inc., an affiliate of Elsevier Inc.1 Digital Radiographic Image Processing and Manipulation.
Image Quality Radiographic Resolution.
Stacy kopso, M.Ed., rt(r)(m) ODIA digital Academy, arrt
Digital Radiology. 2 Aim : To become familiar with the digital imaging techniques in projection radiography and fluoroscopy.Aim : To become familiar with.
ARRT & Other DIGITAL Terms Defined April 2009 Wk 9/10 RT 255.
Seeram Chapter #3: Digital Imaging
RAD 254 Digital Imaging Basic Elements of Digital Imaging CR/DR.
Digital Imaging. acronyms 1.PSP 2.CRT 3.ADC 4.IP 5.CR 6.DR 7.PACS 8.SNR 9.CNR 10. CCD 11. FOV 12. LUT 13. DICOM 14. RIS 15. HIS 16. TFT 17. DQE 18. DAP.
Digital Radiography and PACS By Professor Stelmark.
Things they never tell you when the equipment is installed REV 11/2008
Review CR & DIGITAL IMAGING (1) 2012 – RT 244 wk 15
Sensitometry By Prof. Stelmark. The study of the relationship between the intensity of exposure of the film and the blackness after processing is called.
Radiographic Quality Visibility and Sharpness
More digital reading explaining LUT RT 244 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of.
Image Display. But first a review Remember the 3 main steps 1. Data Acquisition 2. Image Reconstruction 3. Image Display.
Chapter 2 HAEDWAER.
More digital 244 wk 12 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of Medicine Atlanta, GA,
DIGITAL IMAGING.
Digital Radiographic Image Processing and Manipulation Chapter 7.
Digital Radiology Dr M A Oghabian Medical Physics Group Tehran University of Medical Sciences
Image Receptor Unsharpness By Professor Stelmark.
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
DIGITAL RADIOGRAPHY.
Direct Digital Radiography or Direct Capture Radiography
Acronyms. A SEQUENCE OF COMPUTER OPERATIONS FOR ACCOMPLISHING A SPECIFIC TASK Algorithm.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
{ Digital Image Processing By Professor Stelmark.
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Imaging Characteristics
Digital Imaging.
כיצד נרכשת התמונה בסרט הרנטגני?
מה צריך רנטגנאי לדעת על דימות דיגיטלית?
Digital Imaging CHAPTERS 1, 4-7 CARTER.
Fluoroscopic Image Quality Considerations
Digital Fluoroscopy PPT created by: Jed Miles, BSRS, RT(R), CRT-CA
Chapter 6 Cassetteless Equipment and Image Acquisition
Digital Radiographic Image Processing and Manipulation
Digital Imaging.
Digital Imaging.
Presentation transcript:

ARRT & Other DIGITAL Terms Defined Supplement to HW assignment 2014 255 Lect 4

CRT vs LCD CRT Luminance higher in the center LCD Less veiling glare Lower measurable black levels Phosphor granularity adds to spatial noise Viewable area smaller than stated size Better color reproduction More responsive on redraw More rugged Aspect ratio 4:3 LCD Less veiling glare Consumes less energy Increased spatial resolution Larger viewing area by described size Display limited to designed resolution Can position screen Smaller footprint and lighter Widescreen aspect ratio 16:9

Image Display= MONITORS viewing conditions (i.e.,luminance,ambient lighting) spatial resolution contrast resolution/dynamic range DICOM gray scale function window level and width function

MONITORS: Spatial Resolution ARRT DEFINITIONS MONITORS: Spatial Resolution Spatial resolution refers to the amount of detail present in any image. Phosphor layer thickness and pixel size determines resolution in CR. The thinner the phosphor layer is, the higher resolution. Film/screen radiography resolution at its best is limited to 10 line pairs per millimeter (lp/mm). CR resolution is 2.55 lp/mm to 5 lp/mm, resulting in less detail.

MONITOR RESOLUTION

MODULATION TRANSFER FUNCTION - MTF A measure of the ability of the imaging system to preserve signal contrast as a function of the spatial resolution. Every image can be described in terms of the amount of energy for each of its spatial frequency components. MTF often is regarded as the ideal expression of the image quality provided by a detector.

digital image characteristics ARRT definitions digital image characteristics spatial resolution sampling frequency DEL (detector element size) receptor size and matrix size image signal (exposure related) quantum mottle SNR (signal to noise ratio) or CNR (contrast to noise ratio)

Spatial Resolution A radiograph typically does not show soft tissue structures Digital image shows not only the soft tissue but also the edge of the skin. Giving the appearance of more detail.

MONITORS contrast resolution /dynamic range Appearance of more detail is due to the wider dynamic recording range / contrast resolution and does not mean that there is additional detail Because so many more densities are recorded in CR (wide dynamic range), images appear more detailed.

contrast resolution The contrast resolution of a monitor is the difference between the maximum and minimum luminance of the display.

Exposure Latitude or Dynamic Range CR and DR Contain a detector that can respond in a linear manner as compared to S shape of H&D Curve Exposure latitude is wide, allowing the single detector to be sensitive to a wide range of exposures.

Why do digital systems have significantly greater latitude? Linear response give the imaging plates greater latitude Area recieving little radiation can be enhanced by the computer Higher densities can be separated and brought down to the visibile density ranges (Brightness in DR replaces density)

Monitors - RESOLUTION Pixel is a basic picture element on a display. A pixel is “any of the small discrete elements that together constitute an image.” Resolution -# of pixels contained on a display Relationship: More pixels in an image, the higher the resolution & more information that can be displayed. Resolution also is defined as the process or capability of distinguishing between individual parts of an image that are adjacent.

Nyquist frequency ? 10 PIXEL DENSITY WHAT IS THE NYQUIST FREQUENCY= ?

The Nyquist Theorem Theorem states that when sampling a signal, the sampling frequency must be greater than twice the bandwidth of the input signal so that the reconstruction of the original image will be nearly perfect. At least twice the number of pixels needed to form the image must be sampled. If too few pixels are sampled, the result is a lack of resolution.

Nyquist frequency The highest spatial frequency that can be recorded by a digital detector. is determined by the pixel pitch. The Nyquist frequency is half the number of pixels/mm. A digital system with a pixel density of 10 pixels/mm would have a Nyquist frequency of 5 line pair/mm.

Sampling Frequency ? Define ……

ARRT definitions sampling frequency The frequency that a data sample is acquired from the exposed detector. It is expressed in pixel pitch and pixels per mm. Sampling frequency may be determined by receptor size depending on the vendor. KODAK 8x10 better detail than 14x17 Use of the smallest imaging plate possible for each exam results in the highest sampling rate. When the smallest possible imaging plate is selected, a corresponding matrix is used by the computer algorithm to process the image.

Pixel “picture element,” the smallest area represented in a digital image. A digital radiography image consists of a matrix of pixels which is typically several thousand pixels in each direction. Pixel density – A term that describes the number of pixels/mm in an image. Pixel density is determined by the pixel pitch.

DEL (detector element size) receptor size and matrix size a pixel or picture element. The typical number of pixels in a matrix range from about 512 × 512 to 1024 × 1024 and can be as large as 2500 × 2500. The more pixels there are, the greater the image resolution. The image is digitized by position (spatial location) and by intensity (gray level).

DELs – detector elements DELs collect electrons that are extracted from the detector assembly and converted into a digital value by an ADC. That process creates the image that displays on our monitor. DEL size controls the recorded detail, or spatial resolution, for the flat-panel device. The technologist can’t change the size of the DEL, which is fixed for that piece of equipment. .

Detective Quantum Efficiency How efficiently a system converts the x-ray input signal into a useful output image is known as detective quantum efficiency, or DQE. DQE is a measurement of the percentage of x-rays that are absorbed when they hit the detector.

Detective Quantum Efficiency Known as the fill factor, the larger the area of the TFT photodiodes, the more radiation can be detected and the greater amount of signal generated. Consequently, the greater the area of the TFT array, the higher the DQE. Over 1 million pixels are read & converted

FILL FACTOR A field-effect transistor (FET) or silicon TFT Isolates each pixel element Reacts like a switch to send the electrical charges to the image processor

Detective Quantum Efficiency In other words, CR records all of the phosphor output. Systems with higher quantum efficiency can produce higher-quality images at a lower dose. Indirect and direct DR capture technology has increased DQE over CR. However, DR direct capture technology, because it does not have the light conversion step and consequently no light spread, increases DQE the most.

SNR (signal to noise ratio) or CNR (contrast to noise ratio) ARRT definitions SNR (signal to noise ratio) or CNR (contrast to noise ratio) SNR (signal to noise ratio): there is always a very small electric current flowing in any circuit - is called background electronic noise. It is similar to the fog on a radiograph in that it conveys no information and serves only to obscure the electronic signal. CNR (contrast to noise ratio): measure for assessing the ability of imaging an procedure to generate clinically useful image contrast. gives an objective measure of useful contrast.

Image Display spatial resolution contrast resolution/dynamic range

What is a 3-D array of Pixels ? A voxel (a volumetric pixel) is a volume element, representing a 3-D value space. A pixel which represents 2D image data.

Pixel Pitch The space from the center of a pixel to the center of the adjacent pixel. It is measured in microns (μm). Pixel pitch is determined by sampling frequency for cassette-based PSP systems and by DEL spacing for TFT flat panel.

Monitors: Display Workstations Pixels are arranged in a matrix. Common screen resolutions found on today’s monitors are the following: 1280 × 1024 (1K) 1600 × 1200 (2K) 2048 × 1536 (3K) 2048 × 2560 (5K)

Monitors – DOT PITCH Dot pitch is the measurement of how close the dots are located to one another within a pixel. The smaller the dot pitch of a display, the finer the resolution. Dot pitch may be expressed as aperture grille pitch or slot pitch.

Monitors – REFRESH RATE Refresh rate or vertical scanning rate Refresh rate is a measure of how fast the monitor rewrites the screen or the number of times that the image is redrawn on the display each second. Refresh rate helps to control the flicker seen by the user. The higher the refresh rate, the less flicker will be seen. Most refresh rates on today’s computer are set between 60 and 75 Hz; the image is redrawn 60 to 75 timers per second.

Image Display= MONITORS viewing conditions (i.e.,luminance,ambient lighting) spatial resolution contrast resolution/dynamic range DICOM gray scale function window level and width function

MONITOR RESOLUTION DICOM gray scale function – calibration of monitors to the same standard & communication of images Window level affects brightness (density) - B Window width function affects contrast/gray scale - A “windowing and level”

MONITOR Image Manipulation and Enhancement Functions Window/level This is a default function of the left mouse button. By depressing and holding down the mouse button and moving the mouse up and down and left and right, the window and level can be adjusted. Window (width) represents the range of gray values. Level represents the center value of the range. A change in the window and level appears to change the brightness and contrast of the image.

Image Manipulation and Enhancement Functions Other Tools: Annotations Annotations are NOT to be used to label left or right to indicate the patient’s side. Annotations are used to indicate prone or supine, 30 minutes, upright or flat. Any other image information is appropriate. Radiologist will place arrows or circles around pathologic or questionable areas.

MONITOR Image Manipulation and Enhancement Functions Pan, zoom, and magnify Tools are used primarily by the radiologist to increase the size of an area on the image. Magnify usually magnifies a square area of the image Pan and zoom functions are usually used together. Image is first zoomed up to the desired magnification level then Pan icon is activated. Zoomed image can be moved around to view the different areas of the image.

Image Manipulation and Enhancement Functions Measurements Size of a pixel is a known so the software has the ability to measure structures on the image based on this. Angle measurement. Can give an angle measurement between two structures Commonly used when reading spine studies

Image Manipulation and Enhancement Functions Measurements Region of interest Measurement tool determines the pixel intensity of a certain area. Each type of tissue or fluid has a different intensity of reading. Radiologist can make a determination whether something is solid or fluid. Each pixel can have a gray level between 0 (20) and 4096 (212). The gray level will be a factor in determining the quality of the image

DR

Monitor :Navigation Functions Hanging protocols Can be viewed: 1:1 4:1 etc Protocol can also be specified to show the previous exam on one monitor and the current exam on the other Once set, the most efficient study navigation is determined.

Image Management Functions Patient demographics must be correct. If demographics are not correct at the archive level, the images could be lost. Changes should only be made when the information is absolutely known to be wrong. Many hospitals allow only certain persons the access to change demographics just to keep the errors to a minimum.

Image Management Functions Query/retrieve icon Used to retrieve on demand any studies from the archive Allows user to query a study on multiple fields Patient’s name or identification Date of service Modality Diagnosis code or comment field

WINDOW LEVEL / WIDTH Which one controls Denisty (brightness) ? Contrast What else control these in DIGITAL IMAGING?