Implantation of a single-piece acrylic intraocular lens using an anterior chamber maintainer Tomoyuki Kunishige, Hisaharu Suzuki, Toshihiko Shiwa, Hiroshi.

Slides:



Advertisements
Similar presentations
INTRA-OPERATIVE MANAGEMENT OF CATARACT SURGERY COMPLICATIONS Dr. H. Razmjoo Isfahan University of Medical Sciences.
Advertisements

Comparison of Visual Outcomes With Toric IOL and With Limbal Relaxing Incisions in Cataract Surgery Eriko Fukuyama, MD Fukuyama Eye Clinic Fukuoka, Japan.
بسم الله الرحمن الرحيم IN THE NAME OF GOD. Implantation of an Artisan phakic intraocular lens for the correction of high myopia, high hyperopia, aphakia.
Action on cataract Whipps Cross Hospital Harold Wood Hospital North East London Eye Partnership.
CATARACT ASSESSMENT Cataract: opacity of the lens Population at risk: greater than 70 years old S&S: blurred vision.
Yüksel Totan, Ramazan Yaĝcı, Zeynel Arslanyılmaz, Uĝurcan Keskin The authors have no financial interest.
The new Akreos MI 60 lens Joel Pynson, MD - Director Design Engineering Bausch & Lomb, Toulouse - France London, September 9th 2006.
PIGGYBACK LENS AFTER MULTIFOCAL IOL IMPLANTATION Eric C. Amesbury MD Kevin M. Miller MD The authors have no financial interest.
Surgical technique Incision opened up to 3.8mm, Using Monarch injector, Acrysof IOL MA 30 in first 11 cases subsequently single piece inserted first. The.
Astigmatism Following 2 IOL Injection Techniques: Wound Assisted Versus Wound Directed Jay J. Meyer, MD Hart B. Moss, MD Kenneth L. Cohen, MD University.
SPINNING THE WHEEL- STABILITY OF COMMONLY USED IOL IN-THE-BAG DR ARUP BHAUMIK DISHA EYE HOSPITALS AND RESEARCH CENTRE BARRACKPORE, WEST BEGAL, INDIA
A Prospective, Randomized, Comparative Evaluation of Patients with Contralateral Implantation of Two Aspheric Acrylic Intraocular Lenses R. Cionni, MD.
Core Anterior Vitrectomy following Posterior Capsular Rupture SURYA.
Clinical evaluation of foldable acrylic phakic IOL (fP) implantation ASCRS, San Diego, 2011 A.John Kanellopoulos, MD Professor NYU Medical School, NY Director,
Phaco-drainage Phacosection Amporn technique
Phacoemulsification with Goniosynechialysis in the Management of Refractory Acute Angle-closure Glaucoma Ghasem Fakhraie*, MD, Mahmoud Jabbarvand, MD,
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
Intraocular lens dislocation secondary to haptic torsion Lawrence E. Lohman, MD FACS Matthew C. Willett, MD.
Removal of Pediatric Cataract with Intraocular Lens Implantation Using 23 gauge Incisions and 25 gauge Instrumentation Irena Tsui, M.D. Steven Kane, M.D.,
So-Hyang Chung, MD, PhD, Choun-Ki Joo, MD, PhD Department of Ophthalmology and Visual Science, College of Medicine, The Catholic University of Korea, Seoul,
Transparency of Transition from 2.75 mm to 1.8 mm Microincision Surgery Jay McDonald II, MD Adjunct Clinical Professor University of Arkansas School of.
Title slide Surgical Peculiarities in Cases of Irido- fundal Coloboma Having Cataract Extraction Prof Sudarshan K. Khokhar, MD Dr Sanjay K. Mishra, MS.
The Second Report of The National cataract Surgery Registry PATIENTS’ CHARACTERISTICS Table 1.1: Age Distributions.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Effects of Intracameral epi-“Shugarcaine” on Heart Rate and Blood Pressure during Cataract Surgery in patients at risk for Intraoperative Floppy Iris Syndrome.
Purpose: Introduction:  At initial evaluation: For post-op day # 0 patients: Pre-op VA was 20/50.6 (0.395 ± 0.198); Post-op VA was 20/102.0 (0.196 ± 0.162);
Spending 40 cc in an entire Cataract Surgery. Comparative study. Arturo Pèrez-Arteaga M.D. Medical Director & Founder Centro Oftalmològico Tlalnepantla,
*Financial Interest: The authors have no financial interest in the subject matter of this poster. *Disclosure of Unapproved/Off-Label Use: The use of cholesterol.
Glaucoma and Penetrating Keratoplasty : Incidence, Risk Factors, and Outcomes Sonika Gupta Consultant Ophthalmology Max Eye Care New Delhi, India Author.
DSAEK Outcomes in Normal and Abnormal, High-Risk Eyes at an University Practice Hugo Y. Hsu and Sean L. Edelstein The authors have no financial interest.
EVALUATION OF ANTERIOR CHAMBER SULCUS SUPPORTED INTRAOCULAR LENS BY PROF. HAMED NASER EL- DIN TAHA HAED OF OPHTHALMOLOGY DEPT. SAUDI GERMAN HOSPITAL JEDDAH.
Mitsui Memorial Hospital Takayuki Akahoshi, MD The author has no financial interest in the products introduced in this presentation.
Relocating corneal endothelial area by non-contact specular microscopy Tomoyuki Kunishige, M.D., Hisaharu Suzuki, M.D., Hideaki Oharazawa, M.D., Toshihiko.
A case of hypermature cataract formation following implantation of a posterior chamber phakic intraocular lens with a central hole The Catholic University.
Internal Repositioning of Posteriorly Dislocated IOL: User’s Friendly Technique The author have no financial interest in the subject matter of this poster.
Healon5 Visco-sandwich Technique for Phacoemulsification in Morgagnian Cataract Surgery Masaki Sato, MD Tetsuro Oshika, MD Department of Ophthalmology.
The authors have no financial interest in the subject matter of this poster. FINANCIAL DISCLOSURES.
Outcomes of Transscleral Sulcus Fixation of Intraocular Lenses through a 2.4-mm Incision with an Injector System: 1-Year Follow-Up Akiko Masai, MD, Tomoichiro.
Outcomes of Transscleral Sulcus Fixation of Intraocular Lenses through a 2.4-mm Incision with an Injector System: 1-Year Follow-Up Akiko Masai, MD, Tomoichiro.
Quick & Safe Techniques for AcrySof Delivery Dr. Suven Bhattacharjee, MS, DO, DNB, FRF. Complete care Eye Clinic Kolkata, INDIA No Financial Interest
Johns Hopkins Hospital
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
I have no financial interest in any devices or techniques discussed in this presentation.
Advanced Preloaded IOL System A Visco-free Preloaded Injector Kimiya Shimizu MD Professor & Chairman, Department of Ophthalmology Kitasato University,
Hongseok Yang, M.D. Dae Hee Kim, M.D. Department of Ophthalmology, Ajou University School of medicine, Suwon, Korea The authors have no financial interest.
Examination of posterior capsular opacity under intraocular tamponade using silicone oil. Norihito Gotoh, Hiroyuki Matsushima, Koichiro Mukai, Tadashi.
Precision with the VisTor IOL Prof. Med. Manfred Tetz ESCRS 2015 Barcelona.
Liquifaction Method and Extent of Posterior Capsule Opacification: Two-Year Follow-up Marie Kalfertova, Mariya Burova, Pavel Rozsival, Nada Jiraskova Nada.
Comparison of two differents ultrasound mode in BMICS technique : Pulse and Continuous US Danielle DEIDIER M.D. Clinique Saint Vincent Toulon - France.
OUR EXPERIENCE WITH PRELOADED IOL CT LUCIA 601P(Y)
J Cataract Refract Surg 2010; 36: 여의도 성모병원 R3 정연웅/Pf. 정성근
Intraocular lens repositioning in a glaucoma patient with recurrent pupillary capture Kyoung Tak Ma¹, Hyung Won, Bae² , Gong Je Seong², Chan Yun Kim².
Rengaraj Venkatesh, MD, Colin S. H
Authors have no any financial interest in the subject matter
Blood Reflux In Schlemm’s Canal Of Normal Cataract Patients: Simple Way To Identify The Trabecular Meshwork With Healthy Collector Channel Masahiro Maeda1,
Special considerations for DSEK in monocameral eyes
The influence that ophthalmic viscosurgical device gives intra ocular pressure during small incision and ultra small incision cataract surgeries Takuya.
Effects of the “Pop & Prechop” Supracapsular Phacoemulsification Technique on Endothelial Cell Counts and Corneal Clarity Brandon Rodriguez, MD Michael.
New Concept of DSAEK Injecting System
The authors have no financial interest
Özcan R. Kayıkçıoğlu, Sinan Emre
Authors have no financial interests
Z deformity of an acommodative IOL
Long term PCO preventive effect of capsular bending ring
Cataract procedure Date 23/05/2019.
Five-Year Experience With Routine Use of Healon5 in Cataract Surgery
A Simple and Easy Procedure
SUBLUXATION LENS, A NO-RING APPROACH
SPINNING THE WHEEL- STABILITY OF COMMONLY USED IOL IN-THE-BAG
Presentation transcript:

Implantation of a single-piece acrylic intraocular lens using an anterior chamber maintainer Tomoyuki Kunishige, Hisaharu Suzuki, Toshihiko Shiwa, Hiroshi Takahashi Authors have no finacial interest. Nippon Medical School

Backgrounds The ophthalmic viscosurgical devices (OVDs) are now thought to be essential for safe phacoemulsification. However, there are at least 2 concerns regarding OVD use. The first is the intraocular presssure (IOP) elevation after the surgery if the OVD is left in the anterior chamber. The second is the cost of the material because the OVDs are still expensive. If the technique of implanting intraocular lens (IOL) without using OVD is available, it might be helpful to solve these problems.

Purpose To examine a technique for implantation of a single-piece acrylic IOL using an anterior chamber maintainer instead of OVD.

Methods ・ Methods: Male : Female = 3 : 3 (6 eyes) Mean age : 76 years After phacoemulsification was performed through a 2.8-mm superior sclerocorneal incision, an anterior chamber maintainer was inserted into the side port at 3 o'clock. The NY-60 IOL was loaded with balanced salt solution (BSS) in the cartridge. While maintaining the anterior chamber depth and the capsular bag by continuous BSS irrigation, the IOL was inserted. All surgeries were performed by a single surgeon. ・ Subjects :

NY-60 ( iMics 1 ® ) HOYA Injector System NY-60 single-piece acrylic IOL Type-N18 cartridge Setting the IOL in the cartridge with BSS

The detail of the procedure Insert the anterior chamber maintainer Fill the cartridge with BSS Implant the IOL The IOL in the capsular bag

Results In all cases, the IOL was smoothly inserted into the capsular bag without causing the collapse of the anterior chamber or the capsular bag. No serious intraoperative or postoperative complications were observed.

Discussion By using an anterior chamber maintainer, IOL can be inserted safely without using OVD. Also a new IOL cartridge system eliminate the OVD use for IOL setting. Taken together, this method can reduce the risk of the IOP elevation, and lessen the cost of OVD. One important point is that the IOL should be inserted carefully with checking the stability of the anterior chamber depth.

Implantation of a single-piece acrylic intraocular lens using an bimanual Irrigation aspiration. Harshul Tak, J Cataract Refract Surg, 2010 Shimizu, J Cataract Refract Surg, 2008 The technique of IOL implantation into the capsular bag without OVD has been reported. Implantation of a 3-piece silicone intraocular lens using an KS-VF disposable injector. The results of the present study agree with these reports.

Conclusion Using an anterior chamber maintainer, it is possible to implant a single-piece acrylic IOL into the capsular bag safely without using OVD.