1 Pool Barriers Presented by: The Office of Building Code Compliance.

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Swish Automation Ltd Pool Access Safety Systems Overcoming common Myth and Legend Facts surrounding residential pool compliance and the Fencing of Swimming.
Step-by-step guide to prevent falls
2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
7 | Means of Egress (Life Safety Code)
Closed Area Construction
Electronic Locking and Exemption Request Form Training
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Step-by-step guide to prevent falls
Railroad Commission of Texas Railroad Commission of Texas Pipeline Safety Division Damage Prevention Program.
Maine Center for Disease Control & Prevention Radiation Control Program, Radon Section Radon Section Leader Maine DHHS, Radiation Control Program
Fall Protection Falls 4,628 fatal work injuries were recorded in the United States in deaths a week or 12 deaths every day 806 construction related.
Florida Product Approval System Validator Training December 11, 2012 Florida Product Approval System Validator Training December 11, 2012 Florida Building.
Proposed Changes to the ADA & ABA Accessibility Guidelines This presentation was prepared by the U.S. Access Board for the ADA Distance Learning 2000 program.
SWIMMING POOL PRESENTATION. GOALS FOR TONIGHT Understand the importance of swimming pool safety Understand recent legislative changes to the Swimming.
Fences, Gates and Latches Presented by Maureen Williams D&D Technologies (800) , ext. 292
GREENBERG TRAURIG, LLP | ATTORNEYS AT LAW | Application for Waiver(s) for The Waves Hotel in the Historic Lord Balfour Hotel Building 350.
Subpart X Ladders and Stairways 29 CFR Presented By: Joshua C. Rohrig
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
ECE II Objective 2.01 Interpret licensing requirements for early childhood programs.
SCREEN ENCLOSURES WORKGROUP Florida Building Commission March 27, 2012.
Visitability Standards Dan McNabb, Deputy Building Official Planning and Development Review Department.
Height Recommendations September 25, 2008 Zoning Commission Case No The District of Columbia Office of Planning’s Comprehensive Review of Zoning.
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010.
Layers of Protection by Troy Whitfield U.S. Consumer Product Safety Commission These comments are those of the CPSC staff, and have not been reviewed or.
Step-by-step guide to prevent falls Module E - Other Specifications Part C-1-Fall Protection Requirements for Construction.
Ontario Building Code Revision effective Jan 1, 2015
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Effective for applications submitted on September 16 th.
Tom Kader Chief Electrical Inspector Spaces About Electrical Equipment Sufficient access and working space shall be provided and maintained about.
Residential Construction Unit 1 Mr. Todzia.  Definition-Legal requirements designed to protect the public by providing guidelines for structural, electrical,
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Fall Hazards.
Water and Wastewater Certification 1 Water & Wastewater Reference Manual.
Building Codes and Interior Design
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
History TCPA 70’s 1981 Monetary incentive About 1 in 18 qualify Two entities involved TCLEOSE TDI.
2010 Florida Building Code: I nterpretation P rocess O verview.
Indiana Fire Code.
© 2015 American Society for Healthcare Engineering, a personal membership group of the American Hospital Association 155 N. Wacker Drive, Suite 400 | Chicago,
Subcommittee on Heights, Massing, and Alternate Standards    Third Report – January 20, 2009 Planning & Zoning Commission.
Difference between 2003 and 2009 ICC/ANSI A117.1 applicable to the Plumbing Subcode Presented by: John N. Terry Tom Pitcherello.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
FALL PROTECTION. Duty To Have Fall Protection Protection at or above 6’ level Walking/working surfaces inspected before work begins Employees can only.
Office of Safety & Health Consultation Office of Safety & Health Consultation presents Stairways & Ladders.
BUILDING CODES AND ADA/TAS. BUILDING CODES - EGRESS.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Patrick Thorpe AstralPool UK Ltd
Services Currently Provided  FHA/ADA Inspections  Bank Draw Requests  Existing Condition Documentation Services.
PLN  Amendments to Chapters 3, 4 and 11 of the Adams County Development Standards and Regulations concerning the regulation of medical and.
“My Room” Project The Massachusetts Code Book and the rules that apply.
Pool Safety Patrol Subcommittee.
Fall Protection for Construction
Department of Permits, Licenses, and Inspections
Prevention of Falls from Windows
House Bill 535 : 2016 Florida Legislature
City of Healdsburg Construction Codes Amendments & Adoption: 2016 Building Standard Codes Title 24 Parts 1 Thru International Property Maintenance.
Senate Bill 442 The Pool Safety Act.
Commission Meeting February 2018 Building Codes and Standards
Commission Meeting February 2018 Building Codes and Standards
Benefits of Adding a Fence to Your Pool
Florida Building Commission Lightning Protection Workgroup
Subpart M Fall Protection.
Commission Meeting February 2018 Building Codes and Standards
Robin Holdsworth - City of Canning
HELP PREVENT DROWNING
General Requirements of NFPA 101
R Single-Family Home Repair Exemption
Subpart X Ladders and Stairways 29 CFR
Building standards Mr. Da Silva.
Presentation transcript:

1 Pool Barriers Presented by: The Office of Building Code Compliance

2 Senate Bill 86 This bill also known as the “Preston de Ibern/McKenzie Merriam Residential Swimming Pool Safety Act” Created Chapter 515 of the Florida Statutes. This is how it all started. It became effective October 1, 2000.

3 Florida Statutes Legislative findings and intent.--The Legislature finds that drowning is the leading cause of death of young children in this state and is also a significant cause of death for medically frail elderly persons in this state, that constant adult supervision is the key to accomplishing the objective of reducing the number of submersion incidents, and that when lapses in supervision occur a pool safety feature designed to deny, delay, or detect unsupervised entry to the swimming pool, spa, or hot tub will reduce drowning and near-drowning incidents.

4 Florida Statutes 515 It is also the intent of the Legislature that the Department of Health be responsible for producing its own or adopting a nationally recognized publication that provides the public with information on drowning prevention and the responsibilities of pool ownership and also for developing its own or adopting a nationally recognized drowning prevention education program for the public and for persons violating the pool safety requirements of this chapter.

5 Florida Statutes 515 Therefore, it is the intent of the Legislature that all new residential swimming pools, spas, and hot tubs be equipped with at least one pool safety feature as specified in this chapter.

6 Florida Statutes Residential swimming pool safety feature options; penalties.-- (1) In order to pass final inspection and receive a certificate of completion, a residential swimming pool must meet at least one of the following requirements relating to pool safety features: (a) The pool must be isolated from access to a home by an enclosure that meets the pool barrier requirements of s ;

7 Florida Statutes 515 (b) The pool must be equipped with an approved safety pool cover; (c) All doors and windows providing direct access from the home to the pool must be equipped with an exit alarm that has a minimum sound pressure rating of 85 dB A at 10 feet; or

8 Florida Statutes 515 (d) All doors providing direct access from the home to the pool must be equipped with a self-closing, self-latching device with a release mechanism placed no lower than 54 inches above the floor.

9 Florida Statutes 515 A person who fails to equip a new residential swimming pool with a least one safety feature as required in subsection (1) commits a misdemeanor of the second degree.

10 Florida Statutes 515 In addition to the incalculable human cost of these submersion incidents, the health care costs, loss of lifetime productivity, and legal and administrative expenses associated with drownings of young children and medically frail elderly persons in this state each year and the lifetime costs for the care and treatment of young children who have suffered brain disability due to near-drowning incidents each year are enormous.

11 Senate Bill 52 C Section 13. The Florida Building Commission is authorized to provide for uniform implementation of sections , , and , Florida Statutes, by including standards and criteria in the Florida Building Code for residential swimming pool barriers, pool covers, latching devices, door and window exit alarms, and other equipment required in those sections which are consistent with the with the intent of section , Florida Statutes. Thus, the residential swimming pool safety requirements of the Florida Building Code, section 424.2, relating to private swimming pools, of Rule 9B-3.047, Florida Administrative Code, as adopted November 28, 2000, shall take effect January 1,

12 Senate Bill 52 C Definitions Residential swimming pool safety feature options; penalties Residential swimming pool barrier requirements

13 Senate Bill 52 C Thus, the residential swimming pool safety requirements of the Florida Building Code, section 424.2, relating to private swimming pools, of Rule 9B-3.047, Florida Administrative Code, as adopted November 28, 2000, shall take effect January 1, This is where we were on February 12, 2002 before a DEC statement by the Florida Building Code Commission.

14 Section 424 FBC. Swimming Pools and Bathing Places MEDICALLY FRAIL ELDERLY PERSON. Means any person who is at least 65 years of age and has a medical problem that affects balance, vision, or judgment, including, but not limited to, a heart condition,diabetes, or Alzheimer’s disease or any related disorder. YOUNG CHILD. Means any person under the age of 6 years.

15 Section 424 FBC. Swimming Pools and Bathing Places Outdoor Swimming Pools. Outdoor swimming pools shall be provided with a barrier complying with through

16 Section 424 FBC. Swimming Pools and Bathing Places The top of the barrier shall be at least 48 inches above grade measured on the side of the barrier which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade the barrier may be at ground level or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure an the bottom of the barrier shall be 4 inches.

17 Section 424 FBC. Swimming Pools and Bathing Places The barrier may not have any gaps, openings, indentations, protrusions, or structural components that could allow a young child to crawl under, squeeze through, or climb over the barrier as herein described below. One end of the barrier shall not be removable without the aid of tools. Openings in the barrier shall not allow passage of a 4- inch diameter sphere.

18 Section 424 FBC. Swimming Pools and Bathing Places Solid barriers which do not have openings shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints.

19 Section 424 FBC. Swimming Pools and Bathing Places Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches, the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed 1 ¾ inches in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1 ¾ inches in width.

20

21 Section 424 FBC. Swimming Pools and Bathing Places Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches or more, spacing between vertical members shall not exceed 4 inches. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1 ¾ inches in width.

22

23 Section 424 FBC. Swimming Pools and Bathing Places Maximum mesh size for chain link fences shall be a 2 ¼ inch square unless the fence is provided with slats fastened at the top or bottom which reduce the openings to no more than 1 ¾ inches.

24

25 Section 424 FBC. Swimming Pools and Bathing Places Where the barrier is composed of diagonal members, the maximum opening formed by the diagonal members shall be no more than 1 ¾ inches.

26 Section 424 FBC. Swimming Pools and Bathing Places Access gates, when provided, shall comply with the requirements of through and shall be equipped with a self- latching locking device located no less than 54 inches from the bottom of the gate. The device release mechanism shall be located on the pool side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap. Gates that provide access to the swimming pool must open outward away from the pool. The gates and barrier shall have no opening greater than 1/2 inch within 18 inches of the release mechanism.

27

28

29

30

31 Section 424 FBC. Swimming Pools and Bathing Places Where a wall of a dwelling serves as part of the barrier, one of the following shall apply: 1. All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 dB A at 10 feet. The exit alarm shall produce a continuous audible warning when the door and its screen are opened.

32 Section 424 FBC. Swimming Pools and Bathing Places The alarm shall sound immediately after the door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall be equipped with a manual means to temporarily deactivate the alarm for a single opening. Such deactivation shall last no more than 15 seconds. The deactivation switch shall be located at least 54 inches above the threshold of the door.

33 Senate Bill 442 Section 32 of S.B. 442 States that when Chapter 515 F.S. was created it was the intent of the legislature that any alarm that met UL 2017 be a permissive alternative to comply with the pool safety provisions of 515. Further more section 32 orders the Florida Building Commission to amend the Florida Building Code to reflect this intent.

34 Continuation Senate Bill 442 The commission must complete rulemaking before November 1, Upon publication of the applicable Notice of Rule Development in the Florida Administrative weekly, any alarm that complies with U.L shall be allowed.

35 Section 424 FBC. Swimming Pools and Bathing Places Exceptions: a. Screened or protected windows having a bottom sill height of 48 inches or more measured from the interior finished floor at the pool access level. b. Windows facing the pool on floor above the first story. c. Screened or protected pass-through kitchen windows 42 inches or higher with a counter beneath.

36 Section 424 FBC. Swimming Pools and Bathing Places 2. All doors providing direct access from the home to the pool must be equipped with a self-closing, self-latching devices with positive mechanical latching/locking devices installed a minimum of 54 inches above the threshold, which is approved by the authority having jurisdiction.

37 Note: in all cases the barrier must be placed around the perimeter of the pool as per and as per definition of: “Pool Perimeter” A pool perimeter is defined by the limits of the pool deck and any dwelling or non-dwelling wall or any combination thereof which completely surrounds the pool.

38 Note: in all cases the barrier must be placed around the perimeter of the pool as per and as per definition of: “Pool Perimeter” A pool perimeter is defined by the limits of the pool deck and any dwelling or non-dwelling wall or any combination thereof which completely surrounds the pool.

39

40 Section 424 FBC. Swimming Pools and Bathing Places On February 12, 2002 the Building Code Commission approved a DEC statement DCA02-DEC-023 which is not out yet. In said statement the Commission accepted staff recommendation by saying that the site plan that was submitted met the intentions of In essence it allows for the grass around a swimming pool to be considered as a pool deck as long as it is level and stable.

41 DEC Statement It seems that in a round about way it classifies a fence around the property as a non-dwelling wall. And if it meets the requirements for barriers it can be used as such.

42

43

44 Public Swimming Pool, Spa and Hot Tub Barriers Sec 8C- 4 Code of Miami-Dade County All new construction of public swimming pools, spas and hot tubs shall be provided with a permanent barrier complying with the following: (1) The top of the barrier shall be at least 48” above grade measured on the side of the barrier which faces away from the swimming pool.

45 Continuation The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4”.

46 Continuation And it goes on with the same requirements for non climbable as the Florida Building Code and ANSI/NSPI 5. Except for item number 9 which reads as follows: (9) Where the release mechanism of the self- latching device is located less that 54 inches from the bottom of the gate, the release mechanism shall be located on the pool side of the gate at least 3 inches below the top of the gate and barrier shall have no opening greater than 1/2 inch within 18 inches of the release mechanism.

47