Feasibility Analysis h T1 T2 T3 T4 T5 One Dimensional Transient Analysis One Dimensional Finite Difference Steady State Analysis T1 and T5 will be known temperatures The length of the rod and properties will be known
One Dimensional Transient Analysis h T1T2 T3 T4 T5
One Dimensional Transient Analysis h T1T2 T3 T4 T5
Simulation Parameters Copper Rod Parameters Density (kg/m3)8940 Thermal Conductivity (W/mK)401 Specific Heat (J/KgK)394 Length (m)0.254 Diameter (m)0.14 Stainless Steel Parameters Density (kg/m3)7820 Thermal Conductivity (W/mK)43 Specific Heat (J/KgK)490 Length (m)0.254 Diameter (m)0.14
Copper Rod Results After 1 minute After 2 minutes
Copper Rod Results After 3 minutes After 4 minutes
Stainless Steel Rod Results After 5 minutes After 10 minutes
Stainless Steel Rod Results After 20 minutes After 40 minutes
Stainless Steel Rod Results After 60 minutes