Recent developments for the LCLS injector Feng Zhou SLAC Other contributors: Brachmann, Decker, Ding, Emma, Gilevich, Huang, Iverson, Loos, Raubenheimer,

Slides:



Advertisements
Similar presentations
The development of ultra bright electron sources: An overview B.L. Militsyn Accelerator Science and Technology Centre Science & Technology Facility Council,
Advertisements

Henrik Loos LCLS FAC Meeting 27 October RF Gun Status LCLS Facility Advisory Committee Meeting October 26, 2005 Mechanical.
Strecher, compressor and time structure manipulation
Feng Zhou Thank Brachmann, Decker, Ding, Huang, Loos, Raubenheimer, Turner et al for the contributions March 6, 2013 Recent LCLS injector studies & plans.
1 Bates XFEL Linac and Bunch Compressor Dynamics 1. Linac Layout and General Beam Parameter 2. Bunch Compressor –System Details (RF, Magnet Chicane) –Linear.
Approaches for the generation of femtosecond x-ray pulses Zhirong Huang (SLAC)
Hard X-ray FELs (Overview) Zhirong Huang March 6, 2012 FLS2012 Workshop, Jefferson Lab.
Philippe Hering October 30, 2007 Drive Laser Commissioning Results and Plans 1 Drive Laser Commissioning results and plans Philippe.
P. Emma FAC Meeting 7 Apr Low-Charge LCLS Operating Point Including FEL Simulations P. Emma 1, W. Fawley 2, Z. Huang 1, C.
Juhao Wu Feedback & Oct. 12 – 13, 2004 Juhao Wu Stanford Linear Accelerator Center LCLS Longitudinal Feedback with CSR as Diagnostic.
1 Injector Lasers Overview Sasha Gilevich, SLAC April 29, 2004 Drive Laser Specifications Challenges System Description Laser Procurement R&D Effort UV.
Feedback and CSR Miniworkshop on XFEL Short Bunch, SLAC, July 26 – 30, 2004 Juhao Wu, SLAC 1 Juhao Wu Stanford Linear Accelerator.
Paul Emma LCLS Commissioning Status Nov. 11, 2008 SLAC National Accelerator Laboratory 1 LCLS Commissioning Status P. Emma for The.
Sasha GilevichFacilities Advisory Committee October Injector Drive Laser Update 1 Facilities Advisory Committee Meeting.
Feedback and CSR Miniworkshop on XFEL Short Bunch, SLAC, July 26 – 30, 2004 Juhao Wu, SLAC 1 Juhao Wu Stanford Linear Accelerator.
Bill White Drive Laser April 16, Drive Laser Commissioning Experience Reminder of requirements on Drive Laser.
Before aperture After aperture Faraday Cup Trigger Photodiode Laser Energy Meter Phosphor Screen Solenoids Successful Initial X-Band Photoinjector Electron.
Cecile Limborg-Deprey Injector Commissioning September Injector Commissioning Plans C.Limborg-Deprey Gun exit measurements.
SLAC XFEL Short Bunch Measurement and Timing Workshop 1 Current status of the FERMI project (slides provided by Rene Bakker) Photoinjector laser system.
David H. Dowell RF Gun Commissioning LCLS FAC April 16, RF Gun Commissioning Experience David H. Dowell for the LCLS Injector.
Cecile Limborg-Deprey Injector October Injector Physics C.Limborg-Deprey Diagnostics and Commissioning GTL measurements.
Simulation studies of the e-beams for Renkai Li and Juhao Wu 5/20/2014 ALD Review.
LCLS Injector experiments Feng Zhou ARD Thanks Brachmann, Emma, Gilevich, Huang, Ding, and Dowell for great contributions and fruitful discussions.
Siegfried Schreiber, DESY The TTF Laser System Laser Material Properties Conclusion? Issues on Longitudinal Photoinjector.
FEL Beam Dynami cs FEL Beam Dynamics T. Limberg FEL driver linac operation with very short electron bunches.
The UCLA PEGASUS Plane-Wave Transformer Photoinjector G. Travish, G. Andonian, P. Frigola, S. Reiche, J. Rosenzweig, and S. Telfer UCLA Department of Physics.
Summary of issues. RF-Gun cavity – Disk and washer (DAW) : very fast RF ageing, 2 MeV is not enough. – Quasi travelling wave side couple structure : Lower.
Low Emittance RF Gun Developments for PAL-XFEL
Compton based Polarized Positrons Source for ILC V. Yakimenko Brookhaven National Laboratory September 12, 2006 RuPAC 2006, Novosibirsk.
Paul Emma, et. al. Sep. 18, 2013 Paul Emma, et. al. Sep. 18, 2013 Design Considerations for the NGLS (Next Generation Light Source) NGLS.
David H. Dowell and Friends SLAC National Accelerator Laboratory David H. Dowell and Friends SLAC National Accelerator Laboratory The LCLS Gun ICFA Beam.
A bunch compressor design and several X-band FELs Yipeng Sun, ARD/SLAC , LCLS-II meeting.
R&D opportunities for photoinjectors Renkai Li 10/12/2015 FACET-II Science Opportunities Workshops October, 2015 SLAC National Accelerator Laboratory.
K. Floettmann WSHQE, OCT. 5, 2006 WSHQE Oct. 5, 2006 Klaus Floettmann Photo cathode requirements for the European XFEL.
International Linear Collider at Stanford Linear Accelerator Center 9/13/2006 Americas Regional Team FY08-09 Planning Meeting 1 1/11 ILC-Americas FY08-09.
Drive Laser Introduction ‘ir’ master oscillator power amplifier chain (MOPA) uses standard chirped pulse amplification scheme (CPA) third harmonic generation.
Velocity bunching from S-band photoinjectors Julian McKenzie 1 st July 2011 Ultra Bright Electron Sources Workshop Cockcroft Institute STFC Daresbury Laboratory,
Injector Options for CLIC Drive Beam Linac Avni Aksoy Ankara University.
Twin bunches at FACET-II Zhen Zhang, Zhirong Huang, Ago Marinelli … FACET-II accelerator physics workshop Oct. 12, 2015.
Part1: what have we learned from LCLS-I injector? Drive laser systems Cathode Gun & its accessories Injector beamline and operational issues Thanks laser.
김 귀년 CHEP, KNU Accelerator Activities in Korea for ILC.
Awake electron beam requirements ParameterBaseline Phase 2Range to check Beam Energy16 MeV MeV Energy spread (  ) 0.5 %< 0.5 % ? Bunch Length (
Sasha Gilevich, Alan Miahnahri Drive Laser 11/4/2004 Agenda General Information Project Status Transport Tubes Design.
LCLS-II Injector layout design and study Feng Zhou 8/19/2015.
Feng Zhou SLAC Presented at HBB, Havana, Cuba, March 29, 2016 LCLS Injector Improvements & Plans.
X-band Based FEL proposal
PAL-XFEL Commissioning Plan ver. 1.1, August 2015 PAL-XFEL Beam Dynamics Group.
A single-shot method for measuring fs bunches in linac-based FELs Z. Huang, K. Bane, Y. Ding, P. Emma.
Applications of transverse deflecting cavities in x-ray free-electron lasers Yuantao Ding SLAC National Accelerator Laboratory7/18/2012.
B. Marchetti R. Assmann, U. Dorda, J. Grebenyuk, Y. Nie, J. Zhu Acknowledgements: C. Behrens, R. Brinkmann, K. Flöttmann, M. Hüning,
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
Operation and Upgrades of the LCLS J. Frisch 1,R. Akre 1, J. Arthur 1, R. Bionta 2, C. Bostedt 1, J. Bozek 1, A. Brachmann 1, P. Bucksbaum 1, R. Coffee.
Drive-Laser Commissioning Status and Plans
Beam dynamics for an X-band LINAC driving a 1 keV FEL
Short pulse, low charge LCLS operation
Tunable Electron Bunch Train Generation at Tsinghua University
XFEL Beam Physics 10/30/2015 Tor Raubenheimer.
The Cornell High Brightness Injector
LCLS Gun Commissioning Status & Plans David H
Advanced Research Electron Accelerator Laboratory
Z. Huang LCLS Lehman Review May 14, 2009
Drive Laser Facility Layout Drive Laser Architecture Technical Issues
Modified Beam Parameter Range
INJECTOR (WBS 1.2.1) Jym Clendenin, SLAC April 23, 2002
Injector Experimental Results John Schmerge, SSRL/SLAC April 24, 2002
Drive Laser Commissioning Status
LCLS Injector Laser System Paul R. Bolton, SLAC April 24, 2002
LCLS Injector Commissioning P
Injector Drive Laser Technical Status
SuperKEKB required (e+ / e-)
Presentation transcript:

Recent developments for the LCLS injector Feng Zhou SLAC Other contributors: Brachmann, Decker, Ding, Emma, Gilevich, Huang, Iverson, Loos, Raubenheimer, Turner et al 5-way meeting at SLAC February 4-6, 2013

Recent major LCLS injector developments Fantastic laser cleaning results on cathode (2011) – Greatly improved QE, and recovered emittance within 2 wks Simplified temporal and spatial laser distributions on cathode (2010 & 2012) – Simplified laser systems, and – Significantly reduced laser power required from amplifier, and – Improved emittance New uses of existing collimators (2012 & 2013) – First measured slice emittances at BC1; and plan to generate short x-ray pulse – R&D on emittance reduction (with LANL)

LCLS laser cleaning in July 2011: QE evolution laser phase) Original QE was only 5e-6 before any cleaning process QE was firstly increased by 8-10 times upon the laser cleaning QE was further increased by 3 times in the first 6 months following laser cleaning, and then stays at 1.1e-4 from 6 th month to now, 18 th months following cleaning. QE Gun vacuum Laser cleaning results see PRST-AB, Oct 2012

LCLS laser cleaning: emittance evolution Immediately laser cleaning A few weeks later RF conditioning may improve the electron emission profile

Simplified LCLS drive laser: temporal distribution LCLS design required a very uniform temporal laser distribution Simulations shows uniform temporal has a slight better emittance than pure Gaussian, but in the measurements we did not see obvious emittance change for 250pC. Mar 2010 No obvious emittance change observed LCLS design (challenging) Current routine operations

Simplified LCLS drive laser: spatial distribution LCLS design required a very uniform spatial laser distribution Recent simulations show spatial Gaussian-cut laser profile has a better emittance than uniform: more linear space charge Spatial Gaussian-cut profile has: – Saved laser power required from laser amplifier 2-3 times – Improved emittance 30% LCLS design (challenging) Feb 2012 Current routine operations Detail results see PRST-AB, September 2012

Improved emittance with spatial Gaussian-cut laser

Can we further simplify LCLS laser? (personal view only) 68MHz oscillator Stretcher 30fs to 150ps Regen Amplifier Pockels cell 4-pass MPA Compressor 150ps to 3ps UV generator UV telescope IR stretcher 3ps to 8 ps Synchronized to Main Drive Linac RF UV transport to cathode IR telescope & transport to laser heater Iris to define laser size on cathode 760nm, 8-10ps, 1mJ 253nm, 3ps, 2mJ 253nm, 3ps, <100uJ 760nm 30fs Develop loadlock for new cathode with only QE>0.5% – Not worry about QE any more Amplifier can be totally removed – System simplifier and more reliable & better stability – Temporal/spatial much cleaner: better for emittance/  BI 4mJ 30mJ

Measured slice emittances at BC1 with collimator In Nov/December 2012 we developed a new technique to measure slice emittances at LCLS BCs using existing collimators in the middle of BCs: – Measure slice emittance both x & y planes, and – check slice emittance preservations through BC1/BC2 Chirped beam Linac off-crest Chirped beam length 11mm 0.7mm

LCLS slice emittance at BC1 (taken on 12/19/2012) Collimator wakefield effects are negligible (confirmed by Bane) Measured slice x-emittance at BC1 (  m) is larger than injector <0.4  m. More MDs are coming in next a few wks

R&D on emittance reduction using collimator (with LANL) Collimator placed in non-dispersion area: to collimate  beam size 40% emittance reduction is expected with the collimator Collimator wakefield is the major concern 40% emittance reduction

BC1 flat collimator: observed wake effect for smaller gaps  x~250um (Aug2)  x~130um (Sep26) Analytical shows circular collimator has much lower wake effect than flat one (K. Bane) Wake simulations for flat and circular are underway (Z. Li & L. Xiao)

Summary Laser cleaning on LCLS cathode was very successful. However, to make it as a robust cleaning method for XFEL, we need more cleaning tests in RF gun test facilities. New uses of the traditional collimators: – Slice beam diagnostics, and short x-ray pulse generation – Emittance reduction (design/construct/test low wakefield collimator) Simplified LCLS drive laser systems to have simple temporal & spatial laser distributions; e-beam performance is improved as well: – May further simplify laser system and significantly improve e-beam performances

backup

LCLS Cu cathode history 1 st cathode ( July 2008): original QE was <1e-5, and increased to 3e-5 after cleaning process. 2 nd cathode (July May 2011): QE was 5e-5 but decayed to a half in 7-10 days at 120 Hz: – Had to frequently move laser to next spots – Took much tuning time and also not every spot on the cathode can deliver desired small emittance beam 3 rd cathode (May present): original QE was <1e-5, which was not sufficient for users’ operations: – Applied laser cleaning – Laser cleaning does work well so far: QE is 2-3 times last cathode and has no decay so far (~18 months).

Laser cleanings on LCLS cathode in July st area at 3.5mm X-offset (trial test on 6/15/2011) 2 nd area (A) at cathode center cleaned on 07/04/2011 has been used for routine operations for 18 months (QE~1.1e-4) 3 rd area (B) at 2.5mm Y-offset cleaned on 07/26/2011: QE ~1.3e-4

7 months later following laser cleaning For the laser-cleaned area B not used for routine operations, QE was also increased from 6e-5 to 1.3e-4 following the laser cleaning. But the QE is not changed at the non-laser-cleaned areas 5 of14 QE imaging for half laser in cleaned and the other half in un-cleaned areas

17 months later following laser cleaning 6 of14

LCLS thermal emittance LCLS QE is changed by a factor of 2.5 after laser cleaning, but: – Thermal emittance is not changed, and – Corresponding projected emittance at 150/250pC is not changed These contaminations changing QE seem not modify the copper work function. LCLS injector emittance is mostly limited by the copper cathode thermal emittance. Laser cleaning results see PRST-AB, Oct 2012

LCLS drive laser 68MHz oscillator Stretcher 30fs to 150ps Regen Amplifier Pockels cell 4-pass MPA Compressor 150ps to 3ps UV generator UV telescope IR stretcher 3ps to 8 ps Synchronized to Main Drive Linac RF UV transport to cathode IR telescope & transport to laser heater Iris to define laser size on cathode 760nm, 8-10ps, 1mJ 253nm, 3ps, 2mJ 253nm, 3ps, <100uJ 760nm ~30fs Need sufficient laser energy on cathode Need proper spatial/temporal distributions on cathode Need reliable/stable laser

LCLS laser pulse length: slice emittance (250pC)

Full open 255pC 0.46um 0.75mm gap 250pC 0.54um 0.3mm gap 155pC 0.49um 0.2mm gap 105pC 0.34um 0.17mm gap 80pC 0.24um Data taken on 09/26/2012