Self-Contained Breathing Apparatus

Slides:



Advertisements
Similar presentations
Standard 29 CFR Part Respiratory Protection.
Advertisements

Personal Protective Equipment and Self-Contained Breathing Apparatus
MDPI/GOODWILL OIL AND GAS TRAINING
OSHA’s Respiratory Protection Standard 29 CFR
Respirator Training NEPMU-6.
East Carolina University Compressed Gas Safety Training Program
Respiratory Protection Program (RPP) San Joaquin Delta College Revised: 10/05/2011.
PPE (Personal Protective Clothing)
Blackwood Fire Company SCBA Refresher. Regulations NJ PEOSH 12: Respiratory protection devices OSHA 29CFR Operating Guideline 7.2 Firefighter.
2 Fire Fighter Qualifications and Safety Skill Drills.
Blackwood Fire Company IN-HOUSE SCBA REQUALIFICATION.
SFFMA Training Objectives: –
Intermediate SFFMA Objectives: – Hrs received.
RESPIRATORY PROTECTION / E N V I R O N H & S T R A I N I N G P R O G R A M RESPIRATORY PROTECTION The following program presents the respiratory requirements.
OSHA’s Respiratory Protection Standard 29 CFR
OSHA Respiratory Protection Standard – 29 CFR Prepared by Daniel Gearhart, Division Chief, Retired.
Personal Protective Equipment Respirator Usage and Safety.
S.C.B.A. MAINTENANCE By: Lt. Eric Miller Parksville Fire Department.
Self Contained Breathing Apparatus (Positive Pressure) Open Circuit SCBA.
Rules of Air Management Snohomish County Fire Chiefs Air Management (ROAM) Guideline Document (Adopted 12/2009) Purpose: To provide a guideline.
Occupational Safety and Health Course for Healthcare Professionals.
Wellington County Fire Training SCBA Presentation
Self-Contained Breathing Apparatus
Personal Protective Clothing and Equipment 1. Introduction Difference between injury and safety determined by personal protective equipment (PPE) PPE.
Respiratory Protection Program 29 CFR Respiratory Protection Program When respiratory protection is necessary When respiratory protection is.
Safety Training Presentations
Personal Protective Equipment
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
RESPIRATORY PROTECTION STANDARD FEDERAL REGISTER 1/8/98 29 CFR Revised Other OSHA Standards That Incorporated By Reference.
Self-Contained Breathing Apparatus
Safety at the Fire Emergency
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
HDOE Annual Respiratory Protection Training. OSHA’s Respiratory Protection Standard 29 CFR
Seven Mountains EMS Council
Respiratory Protection
Respiratory Safety Public Safety Murray State University.
Hazardous Materials: Personal Protective Equipment
Orientation and Annual Refresher Training
Risk Management Services Confined Space Entry Basics.
10/11/20151 The Recruit will also practice and master certain skills and will be tested on these skills. At the end of each subject there will be a quiz.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
1/05 School Safety Training Respirators A Program Overview WISHA WAC WAC OSHA 29 CFR
NIEHS – HMTRI Katrina Response Initiative 10/17/20052 U45 ES Safety Awareness for responders to Hurricane Katrina Operations: Respiratory Protection.
FFII Module A Hillcrest Fire Department © 2001
RESPIRATOR REFERENCES
Respiratory Protection. Why respiratory protection is necessary v Air contaminants/hazardous atmospheres come from a variety of sources DustsDusts Aerosol.
Respiratory Protection. Why respiratory protection is necessary Air contaminants/hazardous atmospheres come from a variety of sourcesAir contaminants/hazardous.
VRFA ANNUAL RESPIRTORY PROTECTION. THE ADMINISTRATOR.
Emergency Operations with Self Contained Breathing Apparatus (SCBA)
Half-face & Full-face Cartridge Respirators
Fire Fighter Safety. Dangers Associated With Fire Fighting Firefighting by its very nature, is dangerous. Each firefighter must learn safe methods of.
Funding and support for this project has been provided by the State of Washington, Department of Labor & Industries, Safety & Health Investment Projects.
DURAM PERSONAL ESCAPE MASK A simple step for survival Training Manual.
RESPIRATORY TRAINING. Objectives + Why are respirators are necessary + Capabilities & Limitations + Inspecting & Maintaining + Medical Clearance & Fit.
Fire Fighter Safety SCBA CHANGE/REFILL
Essentials of Fire Fighting, 5 th Edition Chapter 5 — Firefighter Personal Protective Equipment Firefighter I.
Respiratory Protection Program
Respiratory Protection Training
What is the hood? Protects portions of the firefighter’s
CTE Respiratory Protection Training
Respiratory Protection Training
Learning Objective 3 Define the ratings in a portable fire extinguisher rating system.
Click anywhere to get started…
East Carolina University Compressed Gas Safety Training Program
Parkwood Volunteer Fire Department John Vargas 1/14/2014
Concorp, Inc. - Respiratory Protection Training. Revision – B
OSHA’s Respiratory Protection Standard 29 CFR
Chapter 10 Personal Protective Equipment
OSHA’s Respiratory Protection Standard 29 CFR
Presentation transcript:

Self-Contained Breathing Apparatus Basic SCBA Self-Contained Breathing Apparatus

Introduction Failure to use the SCBA properly can result in injury or death Respiratory system extremely vulnerable Fire departments must have a mask rule Wear and use SCBA in IDLH atmosphere SCBA necessary even during exterior defensive operations

Introduction (cont’d.) Any inhaled toxic gas can directly cause disease of the lung tissue One in 12 firefighters is injured in the line of duty each year Smoke inhalation accounts for 18 percent of fatalities 21 percent of fireground injuries

Conditions Requiring Respiratory Protection Oxygen deficiency High temperatures Smoke or by-products of combustion Toxic environments

Oxygen-Deficient Environments Fire consumes oxygen Produces toxic gases Displace or dilute oxygen Oxygen concentrations below 19.5 percent are oxygen-deficient atmospheres Affects on the human body: Muscular impairment Mental confusion Death

Table 7-1 Effects of Hypoxia (Reduced Oxygen)

Elevated Temperatures Respiratory system sensitive to temperature Air temperatures as low as 165°F can cause death within 1 minute Inhaling gases causes: Pulmonary edema Asphyxiation Long-term damage Temperatures in structure fire reach 1000°F One unprotected breath will cause death or severe damage to respiratory system

Smoke Unburned products of combustion, particles of carbon, tar, associated gases Large amounts of gases due to use of plastics Inhalation of small amounts may be fatal Four causes of damage by smoke: Asphyxiation Chemical irritation Chemical asphyxiation Any combination of these

Effects of Toxic Gases and Toxic Environments Combustion produces toxic gases and irritants Affect short- and long-term health When combustion products combine may form lethal toxins Some common gases affect circulatory system Commercial occupancies may produce additional toxins Requires higher level of protection

Table 7-2 Toxic Gases Formed as Products of Combustion

Legal Requirements for Self-Contained Breathing Apparatus Use Common sense: Use SCBA on every fire scene Start to finish Regulations developed for SCBA use Organizations established regulations and standards

Title 29 Code of Federal Regulations, Section 1910.134 Establishes standards for all entries into IDLH atmospheres April 1998 revision contains requirements related to interior structural firefighting Defines interior structural firefighting as IDLH Requires the use of SCBA Requirements for complete respiratory protection program Regular medical evaluation

NFPA 1500: Standard on Fire Department Occupational Safety and Health Program Authority having jurisdiction (AHJ) must adopt the standard for the fire department Three additional standards: NFPA 1404: minimum requirements for protection programs NFPA 1981: design and performance criteria NFPA 1982: standards on PASS

Limitations of Self-Contained Breathing Apparatus Understand limitations to use unit effectively and safely Limitations of the SCBA unit itself Size, weight, air supply Physiological limitations of the user

Figure 7-7 Continuous training with SCBA is one of the keys to effective firefighting operations.

SCBA Design and Size SCBA units add weight and bulk to PPE SCBA cylinder consumed more quickly than length of time rated for: Limits advance into building More frequent crew rotations Other concerns: Restricted visibility Added weight and bulk Firefighter’s voice muffled Limited air quantity

Limitations of the SCBA User Physical, mental, emotional state cause usage problems Physical limitations: added weight and bulk Physiological limitations Lack of confidence in SCBA unit Physical stress and anxiety Emotional conditions

Air Supply Management Air supply management Must understand air consumption rates Individual point of no return Heads up display Various methods of breathing take experimentation on the part of the firefighter Use normal breaths and exhale slowly Never hold breath Controlled breathing is most efficient use of air

Figure 7-11 An example of an air consumption test.

Types of Self-Contained Breathing Apparatus Two types of SCBA: Open-circuit SCBA Exhaled air is vented to outside atmosphere Most common Closed-circuit SCBA Exhaled air stays in the system for filtering, cleaning, circulation Sometimes used for specialized rescue incidents

Open-Circuit Self-Contained Breathing Apparatus Designed and built in accordance with NIOSH and NFPA standards Four basic assembly components: Backpack and harness Cylinder Regulator Face piece assembly

Figure 7-13 The four components of the open-circuit SCBA are the backpack/harness, cylinder, regulator, and face piece assemblies.

Head Harness Head Straps Nose Cone Voice Emitter Head Straps Regulator Adapter Port

Air Saver Switch or the Don/Doff Switch Heads Up Display (HUD) Purge Valve (Emergency Bypass) Face Piece Lock Tab Mechanism Regulator Quick Disconnect with HUD Connector Air Saver Switch or the Don/Doff Switch

Closed-Circuit Self-Contained Breathing Apparatus Not used for firefighting operations Most common use: hazardous materials incidents Air supplies range from 30 minutes to four hours Contain cylinder, filter system, regulator, and valves Clean and filter exhaled breath and add oxygen Air supply duration based on filtering/cleaning and oxygen capacity of unit

Open-Circuit Supplied Air Respirators Open-circuit supplied air respirators (SARs) Also called airline respirators Remote air supply Commonly used for hazardous materials incidents Confined space rescues Long-duration of air supply, mobility, agility SCBA escape unit with 510 minutes

Inspection and Maintenance of Self-Contained Breathing Apparatus Inspection on daily or regular basis Always follow manufacturer’s instructions Procedures in this chapter may differ from the recommendation

Daily Maintenance SCBA units should be checked daily If used during emergency scene or training exercise should be serviced in same manner Follow 10-step inspection procedure

Monthly Maintenance Monthly SCBA check contains all elements of the daily check Adds several checks of mechanics of system Irregularities noted and repaired or pull SCBA from service

Annual and Biannual Maintenance NIOSH and SCBA manufacturers require different functional tests of SCBA units Only manufacturer’s authorized or trained service personnel shall conduct these tests Firefighters should refer to the instructions for the SCBA units used

General Considerations Operational safety checks must be performed Conducted on a daily or regular basis Immediately prior to using the SCBA unit If any component does not operate properly or is damaged, unit taken out of service immediately

Figure 7-23 Firefighters must perform regular checks of SCBA to ensure the unit’s ability to operate.

Donning and Doffing Self-Contained Breathing Apparatus Most common donning procedures: Seat-mounted position in the apparatus Side compartment on the apparatus Storage case Refer to manufacturer’s instructions

Storage Case Two methods to don unit: “Over the head” “Coat” Choice is a matter of personal preference and training Refer to donning instructions for the particular SCBA unit

Seat-Mounted Apparatus Allows for quick donning Unit readily available for regular inspection Three important safety requirements: Storing of the face piece Donning the unit while vehicle is moving Checking the cylinder gauge Never don while vehicle is in motion Check gauge before response or use the buddy system

Compartment or Side-Mounted Apparatus Similar to seat-mounted position except firefighter is standing If mount bracket wrong height, use “coat” method Follow donning methods for particular mounting style

Donning the SCBA Face Piece Most SCBA face pieces donned in a similar manner Difference in style of head straps, regulator location Essential to protect firefighter from toxic gases Firefighter must be fitted for the face piece to be used with a particular manufacturer’s SCBA Prohibit anything that may interfere with proper fit and seal of face piece Examples: eye glasses, beards, sideburns

Removing/Doffing the SCBA Unit Generally to remove SCBA donning procedure is reversed If awaiting another assignment, remove face piece Allow normal breathing, conserve air Do not wear the mask without air flowing into it Regulator or face piece must not be contaminated After assignment complete, report to rehabilitation

Self-Contained Breathing Apparatus Operation and Emergency Procedures Fire departments must establish respiratory protection programs Firefighters must be proficient in the safe use of SCBA Donning and doffing procedures Individual limitations Limitations of SCBA unit

Safe Use of SCBA Essential to firefighter survival SCBA unit and protective equipment add weight and bulk Increased exertion and loss of body fluids Firefighters must be aware of symptoms of heat stress Be aware of own limitations and abilities

Operating in a Hostile Environment General rules: Check in with accountability officer when entering or exiting Remain low, check the environment and conditions Never remove the face piece, maintain an awareness of location Ventilate as you advance if it does not spread fire Check for outside openings Maintain direct contact with other team members Never enter a hostile environment alone

Restricted Openings Probe tight spot with a tool Be sure conditions on other side of obstacle are safe Shift pack to left side “Swim” through obstacle backwards “Forward dive” technique Do not remove SCBA unless absolutely necessary

Figure 7-31 Firefighters may have to get beneath an obstacle to facilitate their escape, which may also require them to lower their profile.

Emergency Procedures Emergency procedures exist to assist a firefighter in safe escape from hazard Remain calm, rely on training and knowledge Never remove the face piece of the SCBA Standard emergency check procedure stressed If entangled, do not pull forward Use wire cutters to cut one wire at a time “Swim” method

Figure 7-32 Emergency procedures check.

Changing SCBA Cylinders Cylinders changed after use, following local SOPs Cylinder 90 percent full could mean loss of 25 minutes of air supply Could make the difference in successful exit Follow 12-step replacement procedure Additional steps for two-person SCBA cylinder replacement

Servicing SCBA Cylinders Cylinder serviced when below full Air source must be tested and certified All cylinders must have a current hydrostatic test date All fill stations must have fragmentation containment devices All manufacturer’s recommendations should be followed Fill rate may vary Cascade system Compressor/purifier system

(A) (B) Figure 7-36 (A) A cascade system is one of the systems available to service SCBA cylinders. These may be fixed or mobile units. (B)

Lessons Learned SCBA unit is to a firefighter as a weapon is to a soldier No substitute for proper SCBA training Continued practice and advanced training necessary Prevent failures: thoroughly inspect and test SCBA function as often as possible Firefighters must be prepared to go in harm’s way Be knowledgeable and proficient in use of SCBA

Summary SCBA is one of the most important items of PPE that firefighters have available to them. An increase in safety regulations and improvements in design and construction of SCBA have greatly increased their safety and reliability. An SCBA has limitations and also increases the limitations and demands on the firefighter’s physical conditioning.

Summary The firefighter must be familiar and comfortable with the use, emergency procedures, inspection, and maintenance of an SCBA. The firefighter must be proficient in the proper and rapid procedures for donning and doffing SCBA.