© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4.

Slides:



Advertisements
Similar presentations
Data Storage Solutions Module 1.2. Data Storage Solutions Upon completion of this module, you will be able to: List the common storage media and solutions.
Advertisements

Copyright © 2009 EMC Corporation. Do not Copy - All Rights Reserved.
Module – 3 Data protection – raid
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
1 © Copyright 2013 EMC Corporation. All rights reserved. with For Continuous Operations, VMware and Oracle RAC.
EMC CLARiiON FC4700 Note to Presenter: This customer presentation introduces the CLARiiON FC4700 and highlights its new hardware and software capabilities.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Chapter 3 Presented by: Anupam Mittal.  Data protection: Concept of RAID and its Components Data Protection: RAID - 2.
Managing storage requirements in VMware Environments October 2009.
© 2006 EMC Corporation. All rights reserved. Network Attached Storage (NAS) Module 3.2.
Highly Available Central Services An Intelligent Router Approach Thomas Finnern Thorsten Witt DESY/IT.
Storage area Network(SANs) Topics of presentation
Introduction to the new mainframe: Large-Scale Commercial Computing © Copyright IBM Corp., All rights reserved. Chapter 1: The new mainframe.
Module – 11 Local Replication
Module – 12 Remote Replication
Intelligent Storage Systems
IBM® Spectrum Storage Virtualize™ V V7000 Unified in a nutshell
Introduction to the new mainframe: Large-Scale Commercial Computing © Copyright IBM Corp., All rights reserved. Chapter 6: Accessing large amount.
STORAGE Virtualization
Storage Networking Technologies and Virtualization Section 2 DAS and Introduction to SCSI1.
© 2006 EMC Corporation. All rights reserved. Managing the Data Center Section 5.2.
Module – 7 network-attached storage (NAS)
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Module 10 PS M4110 Components. Module Objectives: Describe the indicators on the front panel of the PS-4110 array Demonstrate how to replace a Disk Drive,
2730/2730T/5730 Performance Comparison 20 May 2008.
© 2009 EMC Corporation. All rights reserved. EMC Proven Professional The #1 Certification Program in the information storage and management industry Intelligent.
11 Capacity Planning Methodologies / Reporting for Storage Space and SAN Port Usage Bob Davis EMC Technical Consultant.
1 © Copyright 2009 EMC Corporation. All rights reserved. Agenda Storing More Efficiently  Storage Consolidation  Tiered Storage  Storing More Intelligently.
Copyright © 2009 EMC Corporation. Do not Copy - All Rights Reserved.
Copyright © 2014 EMC Corporation. All Rights Reserved. Advanced Storage Concepts Upon completion of this module, you should be able to: Describe LUN Migration.
Enhanced HA and DR with MetroCluster & Vmware
Data Center Infrastructure
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
INSTALLING MICROSOFT EXCHANGE SERVER 2003 CLUSTERS AND FRONT-END AND BACK ‑ END SERVERS Chapter 4.
Copyright © 2014 EMC Corporation. All Rights Reserved. Block Storage Provisioning and Management Upon completion of this module, you should be able to:
Copyright © 2011 EMC Corporation. All Rights Reserved. MODULE – 6 VIRTUALIZED DATA CENTER – DESKTOP AND APPLICATION 1.
IMPROUVEMENT OF COMPUTER NETWORKS SECURITY BY USING FAULT TOLERANT CLUSTERS Prof. S ERB AUREL Ph. D. Prof. PATRICIU VICTOR-VALERIU Ph. D. Military Technical.
Chapter 5 Section 2 : Storage Networking Technologies and Virtualization.
Module – 4 Intelligent storage system
DAC-FF The Ultimate Fibre-to-Fibre Channel External RAID Controller Solution for High Performance Servers, Clusters, and Storage Area Networks (SAN)
Copyright © 2014 EMC Corporation. All Rights Reserved. SnapView Snapshot Upon completion of this module, you should be able to: Describe SnapView Snapshot.
© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4.
Database Systems: Design, Implementation, and Management Tenth Edition Chapter 12 Distributed Database Management Systems.
"1"1 Introduction to Managing Data " Describe problems associated with managing large numbers of disks " List requirements for easily managing large amounts.
Copyright © 2014 EMC Corporation. All Rights Reserved. Managing Host Access to Storage Upon completion of this module, you should be able to: Explain Access.
Clustering In A SAN For High Availability Steve Dalton, President and CEO Gadzoox Networks September 2002.
Information Means The World.. Virtualization Model Server VMware Microsoft EDR(VTL) Diligent Quantum DX NetApp EMC Consolidation HDS USP & NSC 55 NetApp.
The concept of RAID in Databases By Junaid Ali Siddiqui.
D0 Disk Array Replacement on d0ora2 May 20, 2005.
70-293: MCSE Guide to Planning a Microsoft Windows Server 2003 Network, Enhanced Chapter 12: Planning and Implementing Server Availability and Scalability.
VMware vSphere Configuration and Management v6
Introduction: Memory Management 2 Ideally programmers want memory that is large fast non volatile Memory hierarchy small amount of fast, expensive memory.
Click to add text Introduction to the new mainframe: Large-Scale Commercial Computing © Copyright IBM Corp., All rights reserved. Chapter 6: Accessing.
EMC Proven Professional. Copyright © 2012 EMC Corporation. All Rights Reserved. NAS versus SAN NAS – Architecture to provide dedicated file level access.
© 2006 EMC Corporation. All rights reserved. The Host Environment Module 2.1.
© 2006 EMC Corporation. All rights reserved. Section 2 – Storage Systems Architecture Introduction.
Modul ke: Fakultas Program Studi Teknologi Pusat Data 13 FASILKOM Teknik Informatika Infrastruktur Pusat Data.
© 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice DP SAS Drives.
EonStor DS series disk arrays
E2800 Marco Deveronico All Flash or Hybrid system
EonStor DS 1000.
70-293: MCSE Guide to Planning a Microsoft Windows Server 2003 Network, Enhanced Chapter 12: Planning and Implementing Server Availability and Scalability.
Data Center Infrastructure
Direct Attached Storage and Introduction to SCSI
Physical Storage Architecture
Introduction to Networks
Storage Virtualization
Module – 7 network-attached storage (NAS)
Direct Attached Storage and Introduction to SCSI
Presentation transcript:

© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 2 Module Objectives After completing this module, you will be able to:  Describe components of intelligent storage system  List benefits of intelligent storage system  Explain intelligent cache algorithms and protection  Describe intelligent storage array implementation – High-end storage array – Mid-range storage array

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 3 What is an Intelligent Storage System Intelligent Storage Systems are RAID arrays that are:  Highly optimized for I/O processing  Have large amounts of cache for improving I/O performance  Have operating environments that provide: – Intelligence for managing cache – Array resource allocation – Connectivity for heterogeneous hosts – Advanced array based local and remote replication options

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 4 Benefits of an Intelligent Storage System Intelligent storage system provides several benefits over a collection of disks in an array (JBOD) or even a RAID arrays: – Increased capacity – Improved performance – Easier data management – Improved data availability and protection – Enhanced Business Continuity support – Improved security and access control

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 5 Components of an Intelligent Storage System Host Connectivity FC SAN Front EndBack End Cache Physical Disks Intelligent Storage System

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 6 Intelligent Storage System: Front End Host Connectivity Front EndBack End Cache Physical Disks Intelligent Storage System FC SAN Ports Controllers

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 7 Front End Command Queuing DCBA DCBA A B C D I/O RequestsI/O Processing Order Front-End Controller Cylinders Without Optimization (FIFO) DBCADCBA A B C D I/O RequestsI/O Processing Order Front-End Controller Cylinders With command queuing

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 8 Intelligent Storage System: Cache Host Connectivity Front EndBack End Cache Physical Disks Intelligent Storage System FC SAN

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 9 Write Request Write Operation with Cache Write Request Write-through Cache Write-back Acknowledgement Cache Acknowledgement

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 10 Read Request Cache Read Request Cache Data found in cache = ‘Hit’ No data found = ‘Miss’ Read Operation with Cache: ‘Hits’ and ‘Misses’

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 11 Cache Management: Algorithms  Least Recently Used (LRU) – Discards least recently used data  Most Recently Used (MRU) – Discards most recently used data New Data Oldest Data

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 12 Cache Management: Watermarking LWM HWM 100 % Idle flushing High watermark flushingForced flushing  Manage peak I/O requests “bursts” through flushing/de- staging – Idle flushing, High Watermark flushing and Forced flushing  For maximum performance: – Provide headroom in write cache for I/O bursts

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 13 Cache Data Protection  Protecting cache data against failure: – Cache mirroring  Each write to the cache is held in two different memory locations on two independent memory cards – Cache vaulting  Cache is exposed to the risk of uncommitted data loss due to power failure

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 14 Intelligent Storage System: Back End Host Connectivity PortsControllers Front EndBack End Cache Physical Disks Intelligent Storage System FC SAN

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 15 Intelligent Storage System: Physical Disks Host Connectivity Front EndBack End Cache Physical Disks Intelligent Storage System FC SAN

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 16 What the Host Sees – RAID Sets and LUNs Host 1 Host 2 LUN 0 LUN 1 Front EndBack End Cache Physical Disks Intelligent Storage System LUN 0 LUN 1 Connectivity FC SAN

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 17 LUN Masking  LUN masking is access control mechanism  Process of masking LUNs from unauthorized access  Implemented on storage arrays  Storage group logical entity that contains one or more LUNs and one host

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 18 ISS Implementation: High-end Storage Systems  Also referred as Active-active arrays – I/O’s are serviced through all the available path  Following are high-end array capabilities: – Large storage capacity – Huge cache to service host I/Os – Fault tolerance architecture – Multiple front-end ports and support to interface protocols – High scalability – Ability to handle large amounts of concurrent I/Os  Designed for large enterprises Host Storage Array Active-Active Configuration Active LUN Controller A Controller B Port

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 19 Midrange Storage Systems  Also referred as Active-passive arrays – Host can perform I/Os to LUNs only through active paths – Other paths remain passive till active path fails  Midrange array have two controllers, each with cache, RAID controllers and disks drive interfaces  Designed for small and medium enterprises  Less scalable as compared to high-end array Host Storage Array Active-Passive Configuration Active Passive LUN Controller A Controller B Port

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 20 Module Summary Key points covered in this module:  Intelligent Storage Systems features  Components of Intelligent Storage Systems  Cache management algorithms  Intelligent Storage System implementation – High-end storage array – Mid range storage array

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 21 Concept in Practice: EMC CLARiiON  Support for UltraFlex technology  Scalable from up to 960 disks  Supports flash drives  Supports different types and sizes of drives, and RAID types (0, 1, 1+0, 3, 5, 6)  Supports up to 16 GB of available cache memory per controller (Storage Processor)  Enhances availability with non disruptive upgrade and failover  Ensures data protection through mirrored write cache and cache vaulting  Supports storage-based local and remote data replication – Through SnapView and MirrorView software

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 22 CLARiiON CX-4 Architecture

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 23 EMC Symmetrix  Incrementally scalable to 2,400 disks  Supports Flash-based solid-state drives  Dynamic global cache memory (16 GB– 512 GB)  Advanced processing power (up to 130 PowerPC)  Direct matrix Architecture  High data processing bandwidth (up to 128 GB/s)  Data protection with RAID 1, 1+0 (also known as 10 for mainframe), 5, and 6  Storage-based local and remote replication – Through TimeFinder and SRDF software

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 24 Direct Matrix Architecture

© 2009 EMC Corporation. All rights reserved. Intelligent Storage System - 25 Check Your Knowledge  What are the parts of an Intelligent Storage System?  What are the differences between a high-end and midrange storage array?  What is the difference between a read cache hit and a read cache miss?  What is the difference between Least Recently Used and Most Recently Used algorithms?  What is the difference between Write-through and Write- back cache?