Open loop vs closed loop By Norbert Benei ZI5A58.

Slides:



Advertisements
Similar presentations
CprE 458/558: Real-Time Systems
Advertisements

CONTROL SYSTEMS: WHAT THEY ARE
Ratio Control Chapter 15.
Mechatronics and microprocessor. Outline Introduction System and design of system Control, measurement and feed back system Open and closed loop system.
Lect.7 Steady State Error Basil Hamed
LECTURE#08 PROCESS CONTROL STRATEGIES
THE INTRODUCTION OF AUTOMATIC PROCESS CONTROL
CHE 185 – PROCESS CONTROL AND DYNAMICS
CHE 185 – PROCESS CONTROL AND DYNAMICS PID CONTROL APPLIED TO MIMO PROCESSES.
Control System Design Based on Frequency Response Analysis
Enhanced Single-Loop Control Strategies
Chapter Summer 2. Comparator 3. Block Blocks in Series
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Systems.
Chapter 7 PID Control.
Control Systems.
Lecture 3: Bridge Circuits
Modeling & Simulation of Dynamic Systems Lecture-2 Review of Basic Concepts of Classical control 1 Dr. Imtiaz Hussain Associate Professor Department of.
Unit 3a Industrial Control Systems
Introduction to Industrial Control Systems
Chapter 8 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
INDUSTRIAL ELECTRONICS CONTROL EET425/4 Lecturers Indra Nisja School of Electrical System Engineering Northern Malaysia University College of Engineering.
System & Control Control theory is an interdisciplinary branch of engineering and mathematics, that deals with the behavior of dynamical systems. The desired.
Cascade and Ratio Control
System/Plant/Process (Transfer function) Output Input The relationship between the input and output are mentioned in terms of transfer function, which.
A Typical Feedback System
Brief Review of Control Theory
Control Engineering Application
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Chapter 14 Frequency Response Force dynamic process with A sin  t, Chapter
What is Control System? To answer this question, we first have to understand what a system is Simon Hui Engineer Control and Informatics, Industrial Centre.
Control Systems Engineering
Dr. Tamer Samy Gaafar.   Teaching Assistant:- Eng. Hamdy Soltan.
Control Systems and Adaptive Process. Design, and control methods and strategies 1.
Low Level Control. Control System Components The main components of a control system are The plant, or the process that is being controlled The controller,
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Chapter 7 Adjusting Controller Parameters Professor Shi-Shang Jang Chemical Engineering Department National Tsing-Hua University Hsin Chu, Taiwan.
Industrial Electronic Department Copyright of German Malaysian Institute. All rights reserved.
1 Introduction to Control System CHAPTER 1. 2   Basic terminologies.   Open-loop and closed-loop.   Block diagrams.   Control structure. . 
Module 1: Measurements & Error Analysis Measurement usually takes one of the following forms especially in industries: Physical dimension of an object.
Networks in Engineering A network consists of a set of interconnected components that deliver a predictable output to a given set of inputs. Function InputOutput.
Lecture 3: Bridge Circuits
Systems.
Features of PID Controllers
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
System A collection of parts that perform a function.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Name of Student : PATEL ARPITKUMAR RAJNIKANT Enrollment No
MISS. RAHIMAH BINTI OTHMAN
Feedforward Control ( 前馈控制 ) Dai Lian-Kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Feedforward Control ( 前馈控制 ) Liankui DAI Institute of Industrial Control, Zhejiang University, Hangzhou, P. R. China 2009/04/22.
C HAPTER 1 Introduction to control system. The basic ingredients of control system can be described by: Objectives of control or input. Control-system.
بسم الله الرحمن الرحيم وبه نستعين
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
Author: Nurul Azyyati Sabri
SAL COLLEGE OF ENGINEERING
EE4262 Digital and Non-Linear Control
Open loop vs closed loop
Automatic Control Theory
Introduction to control system
Chapter 12. Controlling the Process
Lesson 2: Performance of Control Systems
Feedforward Control (前馈控制)
Linear Control Systems
Overview of Control System
Chapter 1: Introduction to Control Systems Objectives
How electronic systems work using the Systems approach.
Presentation transcript:

Open loop vs closed loop By Norbert Benei ZI5A58

Open-loop An open-loop controller, also called a non- feedback controller, is a type of controller which computes its input into a system using only the current state and its model of the system. An open-loop controller, also called a non- feedback controller, is a type of controller which computes its input into a system using only the current state and its model of the system.

Open-loop A characteristic of the open-loop controller is that it does not use feedback to determine if its output has achieved the desired goal of the input. This means that the system does not observe the output of the processes that it is controlling. Consequently, a true open-loop system can not engage in machine learning and also cannot correct any errors that it could make. It also may not compensate for disturbances in the system. A characteristic of the open-loop controller is that it does not use feedback to determine if its output has achieved the desired goal of the input. This means that the system does not observe the output of the processes that it is controlling. Consequently, a true open-loop system can not engage in machine learning and also cannot correct any errors that it could make. It also may not compensate for disturbances in the system.

Closed-loop Close loop control systems use the open loop systems (as forward path) and feedback from the output to decide the input level to the open loop system. And because the input is decided based on how much away the output is from the desired level, the non idealities in forward path do not degrade the system performance. The accuracy of the output thus depends on the feedback path, which in general can be made very accurate. Close loop control systems use the open loop systems (as forward path) and feedback from the output to decide the input level to the open loop system. And because the input is decided based on how much away the output is from the desired level, the non idealities in forward path do not degrade the system performance. The accuracy of the output thus depends on the feedback path, which in general can be made very accurate.

Differences The terms open-loop control and closed-loop control are often not clearly distinguished. Therefore, the difference between open-loop control and closed-loop control is demonstrated in the following example of a room heating system. In the case of open-loop control of the room temperature according to Figure the outdoor temperature will be measured by a temperature sensor and fed into a control device. The terms open-loop control and closed-loop control are often not clearly distinguished. Therefore, the difference between open-loop control and closed-loop control is demonstrated in the following example of a room heating system. In the case of open-loop control of the room temperature according to Figure the outdoor temperature will be measured by a temperature sensor and fed into a control device.

Open-loop

Closed-loop In the case of closed-loop control of the room temperature as shown in Figure the room temperature is measured and compared with the set-point value. If the room temperature deviates from the given set-point value, a controller (C) alters the heat flow. All changes of the room temperature, e.g. caused by opening the window or by solar radiation, are detected by the controller and removed. In the case of closed-loop control of the room temperature as shown in Figure the room temperature is measured and compared with the set-point value. If the room temperature deviates from the given set-point value, a controller (C) alters the heat flow. All changes of the room temperature, e.g. caused by opening the window or by solar radiation, are detected by the controller and removed.

Closed-loop

The order of events to organise a closed-loop control is characterised by the following steps: Measurement of the controlled variable Measurement of the controlled variable Calculation of the control error (comparison of the controlled variable with the set-point value ) Calculation of the control error (comparison of the controlled variable with the set-point value ) Processing of the control error such that by changing the manipulated variable the control error is reduced or removed Processing of the control error such that by changing the manipulated variable the control error is reduced or removed

Comparing open-loop control with closed- loop control the following differences are seen:

Closed-loop control shows a closed-loop action (closed control loop); shows a closed-loop action (closed control loop); can counteract against disturbances (negative feedback); can counteract against disturbances (negative feedback); can become unstable, i.e. the controlled variable does not fade away, but grows (theoretically) to an infinite value. can become unstable, i.e. the controlled variable does not fade away, but grows (theoretically) to an infinite value.

Open-loop control shows an open-loop action (controlled chain); shows an open-loop action (controlled chain); can only counteract against disturbances, for which it has been designed; other disturbances cannot be removed; can only counteract against disturbances, for which it has been designed; other disturbances cannot be removed; cannot become unstable - as long as the controlled object is stable. cannot become unstable - as long as the controlled object is stable.

Summarising these properties we can define: Systems in which the output quantity has no effect upon the process input quantity are called open-loop control systems. Systems in which the output quantity has no effect upon the process input quantity are called open-loop control systems. Systems in which the output has an effect upon the process input quantity in such a manner as to maintain the desired output value are called closed-loop control systems. Systems in which the output has an effect upon the process input quantity in such a manner as to maintain the desired output value are called closed-loop control systems.

Thank you for your attention