Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.

Slides:



Advertisements
Similar presentations
Plunger Pump Basic Theory (1/11)
Advertisements

VSH2 Nitrogen Over Hydraulic Unit
Working principles of pumps
Water Hydraulic Valves
OFFICINE MECCANICHE GALLARATESI
Unit Eight Check Valves, Cylinders, and Motors
Fluid Power Hydraulic Cylinders
For system diagrams and component identification
Drilling Engineering – PE311 Circulating System
4-1 Chapter 4 Overview b The DCM is very complex Mechanical, electrical, hydraulic and safety systems all work together Mechanical, electrical, hydraulic.
Glycol Pumps Operating Pressure: 100 to 1500 psi Circulation Rate: 3 to 450 gph.
COMMERCIAL REFRIGERATION
NITRO SHOCK ABSORBERS.
Hydraulics.
Proper Pump Installation Practices
Exhaust valve Exhaust valves open inwards into the cylinder, so that the gas pressure in the cylinder will ensure positive closure and help in dislodging.
Advanced Pump Fundamentals Agenda
Introduction to Hydraulics ClassAct SRS enabled. In this presentation you will: identify the fundamental parts of a hydraulic system and safety issues.
1 The ProMus Pump A New Direction in ProMinent Metering Pumps.
PUMPS, VALVES, & FANS …Moving fluids Objectives Comprehend the basic construction and application of valves used Comprehend the basic construction and.
ME8843 The George W. Woodruff School of Mechanical Engineering ME 8843 Advanced Mechatronics Instructor: Professor Charles Ume Introduction to Hydraulic.
Actuators.
AIRCRAFTS HYDRAULIC SYSTEM
Hydraulic Drives and Actuators. Description A hydraulic drive consists of three major parts: The generator (such as a hydraulic pump) driven by an electric.
Air Compressors.
Reciprocating pump Pumps are used to increase the energy level of water by virtue of which it can be raised to a higher level. Reciprocating pumps are.
Hydraulics For The Long Term
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Muhajir Ab. Rahim School of Mechatronic Engineering
Glycol Pumps Operating Pressure: 100 to 2000 psi Circulation Rate: 3 to 450 gph.
Chapter 12 Fluid Power. Objectives Upon completing this chapter, you should be able to: –Discuss some fluid power fundamentals –Explain psi, psig, psia,
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Pneumatic and hydraulic actuation systems
PUMPS, VALVES, & FANS …Moving fluids Objectives Comprehend the basic construction and application of valves used Comprehend the basic construction and.
June 1999ProMinent Fluid Controls1 alpha Series Metering Pumps ProMinent noelt: NEW CI noelt: NEW CI.
Pumps Unit 10. Learning Objectives TLW be able to describe the following about pumps used in the process industry: –Types –Uses –Operation –Monitoring.
PRESENTED BY : N.SRIKAUSIGARAMAN
Makro Series Metering Pumps
Experts in Chem-Feed and Water Treatment Specialty Metering Pumps and Feed Equipment ProMinent Orlita.
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
ENTC-370PROF. ALVARADO1 Fluid Mechanics LAB: Actuator Constructions and Component Identification.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
Experts in Chem-Feed and Water Treatment EXtronic Explosion-Proof Pump.
Unit 6 Pneumatics and hydraulics Technology 4.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Fluid Power Control.
Submitted by Pradeep pataskar Roll no.11031M02034.
2016 Launch. What is an AODD ? A diaphragm pump (also known as a membrane pump, air- operated double diaphragm pump [AODD] or pneumatic diaphragm pump)
Positive Displacement Pumps
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
Force Feed Lubricator System
Air Compressors Capacity Horsepower Pressure Duty Cycle.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
Active Learning Assignment, FFO, BE- Sem 3rd – 2nd year
FLUID POWER CONTROL ME604C. FLUID POWER MODULE:02 ~ HYDRAULIC SYSTEM COMPONENTS.
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (Part 3) TRANSPORTATION SYSTEM.
Linear actuator Cylinders Single acting Double acting
Engineering II – August 2016
HYDRAULIC AND PNUEMATIC ACTUATION SYSTEMS
GOVERNMENT ENGINEERING COLLEGE DAHOD
INDUSTRIAL HYDRAULICS
Cylinder Cushioning mechanism
SLIDING VANE PUMPS.
Hydraulic Pressure Control
Positive Displacement Devices
PUMPS AND DRIVERS NCCER
Hydraulic Flow Control • Metering Fluid Flow
Pneumatic System Conditioning
Hydraulic Cylinders • Hydraulic Motors
Presentation transcript:

Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics

Experts in Chem-Feed and Water Treatment Mechanical Diaphragm Packed Plunger Hydraulic Diaphragm Different types of drives

Experts in Chem-Feed and Water Treatment Diaphragm with Steel Core Reciprocating Shaft Advantages: - Lower cost due to simpler construction - Ease of diaphragm replacement - Sealless design - no fugitive emissions - No possibility of cross-contamination of hydraulic fluid and chemical Disadvantages: - Lower pressure ratings (max <200 psig) - Lower repeatability (< +/- 2%) Mechanically-Actuated Diaphragm

Experts in Chem-Feed and Water Treatment Plunger Packing Flush Connector Advantages: - High pressure capabilities (4600 psig) - Greater repeatability (< +/- 0.5%) Disadvantages: - Fugitive emissions may escape through packing Packed Plunger

Experts in Chem-Feed and Water Treatment Diaphragm Air Bleed / Pressure Relief Valve Hydraulic Fluid Reservoir Piston Valve Actuator Make-Up Valve Advantages: - Higher pressure capabilities - Sealless design - no fugitive emissions - Greater repeatability (< +/- 0.5%) Disadvantages: - Possibility of cross-contamination of hydraulic fluid and chemical - Higher cost due to complexity of design - Difficulty of diaphragm replacement and balancing of hydraulic fluid Hydraulically-Driven Diaphragm

Experts in Chem-Feed and Water Treatment MFMH PSDR

Experts in Chem-Feed and Water Treatment Diaphragm type Mf Hydraulically actuated diaphragm head. A double PTFE diaphragm hermetically separates the liquid end from the hydraulic chamber

Experts in Chem-Feed and Water Treatment Mf Highlights  hermetically sealed  pressure up to 630 bar (9,135 psig)  temperature range – 40 °C  to °C (- 40 °F to 320 °F)  PTFE double diaphragm  suction lift up to 8 m (26 ft)  Due to the mechanical rod attached to the diaphragm  accuracy ± 05 %  diaphragm failure indication

Experts in Chem-Feed and Water Treatment Diaphragm type Mh Hydraulically actuated diaphragm head. A metal diaphragm hermetically separates the liquid end from the hydraulic chamber similar to the ProMus pump

Experts in Chem-Feed and Water Treatment Mh Highlights:  hermetically sealed  pressure up to 4000 bar (58,000 psig)  temperature range – 60 °C to °C (- 76 °F to 320 °F)  accuracy ± 0.5 %  diaphragm failure indication

Experts in Chem-Feed and Water Treatment Plunger type PS Plunger head with stuff box packing. The plunger oscillates in the cylinder to displace the liquid.

Experts in Chem-Feed and Water Treatment PS Highlights:  best hydraulic efficiency  pressure up to 1000 bar (14,500 psig)  temperature range – 40 °C to °C (- 40 °F 752 °F)  accuracy ± 0.5 %  easy to maintain by central packing adjustment

Experts in Chem-Feed and Water Treatment Valveless metering pump DR Valveless operating metering pump with a control piston. It works by the combined oscillating and rotating movement of the piston. Valves are not required. The pump can be operated through a wide range of stroke frequencies.

Experts in Chem-Feed and Water Treatment DR Highlights:  valveless  viscosity up to 1,000,000 mPas (1,000,000 cps)  pressure up to 630 bar (9135 psig)  temperature range – 40 °C to °C (- 40 ° F to 752 °F)  accuracy ± 0.5 %  wide range of stroke frequency

Experts in Chem-Feed and Water Treatment  Hydraulically Actuated Diaphragm  Flows to 101 gph  Pressures to 3500 Psi  Cast Iron Drive Case  Liquid End Materials  Stainless Steel  Hastelloy C  Alloy 20  Easy Field Maintenance ProMus

Experts in Chem-Feed and Water Treatment The internal components of a ProMus pump

Experts in Chem-Feed and Water Treatment

Experts in Chem-Feed and Water Treatment Replenishment Circuit Plunger Replenishment Check Replenishment Valve Relief Poppet

Experts in Chem-Feed and Water Treatment Replenishment Check Prevents hydraulic oil from returning back to the drive case

Experts in Chem-Feed and Water Treatment Replenishment Valve Small amounts of hydraulic oil that is lost due to normal air bleed needs to be replenished. The valve is depressed by the diaphragm and admits hydraulic oil on the suction stroke.

Experts in Chem-Feed and Water Treatment Air Bleed Poppet/Relief Valve Allows air to be purged from the hydraulic oil. It checks in both suction and discharge stroke.

Experts in Chem-Feed and Water Treatment

Experts in Chem-Feed and Water Treatment Oil Lubrication/Hydraulic flow

Experts in Chem-Feed and Water Treatment Size 17

Experts in Chem-Feed and Water Treatment Size 30

Experts in Chem-Feed and Water Treatment Size 40

Experts in Chem-Feed and Water Treatment What Can Go Wrong ??

Experts in Chem-Feed and Water Treatment This is usually caused when manually over priming the hydraulics after a diaphragm replacement. All of the air is displaced with hydraulic fluid “ballooning” the diaphragm towards the liquid end and you re-insert the internal relief poppet without loosening the internal relief adjusting screw. Diaphragm Rupture Manually over priming the hydraulics

Experts in Chem-Feed and Water Treatment If diaphragms keep rupturing towards the liquid end after continuous normal running. Check the replenishment valve for sticking open. Problem Area

Experts in Chem-Feed and Water Treatment Hydraulic Shock When there is a pulsation dampener at the discharge and the pressure is increased above the operating pressure causing the internal relief to lift, All of the hydraulic fluid behind the diaphragm is safely dumped back to the drive case. The stored energy from the pulse dampener causes a hydraulic shock until the valve balls seat firmly. This causes the diaphragm to collapse against the contour plate until the pump is out of relief. With the pump running in relief can cause the diaphragm to dimple and or rupture depending on the amount of time and pressure. it’s recommended to replace the diaphragm if running in relief for 24 Hrs.

Experts in Chem-Feed and Water Treatment Over heating or lack of lubrication This can be caused from A. diaphragm rupture and product leaking into the drive case displacing the oil. B. Improper maintenance and oil level to low C. Chemical attack

Experts in Chem-Feed and Water Treatment

Experts in Chem-Feed and Water Treatment Normal air bleed Like a heart beat

Experts in Chem-Feed and Water Treatment Either the Poppet is bad or the pump is running in relief Loss of flow or pressure check sight tube Problem Area

Experts in Chem-Feed and Water Treatment

Experts in Chem-Feed and Water Treatment No Heart Beat or loss of visible fluid flow

Experts in Chem-Feed and Water Treatment Loss of hydraulic prime or visible flow Check the inlet filter for being clogged Problem Area

Experts in Chem-Feed and Water Treatment